Michael Sullivan-Mee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Sullivan-Mee has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Clifford Qualls
Department of Mathematics and Statistics, University of New Mexico, Albuquerque, NM
7 shared publicationsKathy D. Halverson
4 shared publicationsGlenn B. Saxon
3 shared publicationsMollie C. Saxon
3 shared publicationsDenise Od Pensyl
Eye Clinic Raymond G. Murphy VA Medical Center
2 shared publicationsSuchitra Mph Katiyar
Eye Clinic Raymond G. Murphy VA Medical Center
2 shared publications
Latest Publications
- Open Access
- 24 February 2026
- Published by Elsevier in AJO International
- Vol. 3 (1)
Identifying rapid glaucoma progressors at baseline using 10–2 visual field testing
- 24 February 2026
- Published by Elsevier in AJO International
- Vol. 3 (1)
Open AccessIdentifying rapid glaucoma progressors at baseline using 10–2 visual field testing
- 12 October 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 32 (1) , 1-8
Baseline 10-2 Visual Field Loss as a Predictor for Future Glaucoma Progression
Précis: Presence of baseline 10-2 visual field (VF) loss was the strongest predictor of future rate of 24-2 VF loss and development of new 24-2 progression events, suggesting a role for 10-2 VF testing in baseline glaucoma risk analysis. Purpose: The purpose of this study is to examine the relationship between baseline 10-2 VF loss and future 24-2 VF loss. Materials and Methods: Subjects were participating in a prospective longitudinal study within a VA Medical Center outpatient eye clinic. Eligibility required 2 good quality baseline 10-2 VF tests followed by a minimum of 5 good quality 24-2 VF tests over at least 3 years. Longitudinal 24-2 VF testing was completed every 4–6 months after baseline 10-2 testing. Mixed model regression analyses and Cox Proportional Hazard regression analyses were completed to identify predictors of 24-2 mean deviation change rate and new VF loss events. Results: We studied 394 eyes of 202 subjects (119 primary open angle glaucoma and 83 glaucoma suspect). Over 6.7 (±1.5) years, 9.9 (±2.3) good quality 24-2 VF tests were completed. In mixed model regression analyses, baseline variables that predicted faster rate of 24-2 VF loss in order of strength of association were presence of baseline 10-2 VF defect, lower 24-2 mean deviation, and higher age. When analyses were completed without 10-2 variables, predictive capability of the model was reduced compared with when 10-2 variables were included. In Cox Proportional Regression analyses evaluating progression events, baseline 10-2 VF defect demonstrated the largest hazard ratio (22 times greater risk for developing future VF loss event in eyes with vs. without baseline 10-2 VF loss). Conclusions: Baseline 10-2 VF defect was the most effective predictor of subsequent 24-2 VF progression in this study. These findings imply that presence of baseline 10-2 VF loss may provide unique value for predicting future glaucoma progression.
- 12 October 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 32 (1) , 1-8
Baseline 10-2 Visual Field Loss as a Predictor for Future Glaucoma Progression
Précis: Presence of baseline 10-2 visual field (VF) loss was the strongest predictor of future rate of 24-2 VF loss and development of new 24-2 progression events, suggesting a role for 10-2 VF testing in baseline glaucoma risk analysis. Purpose: The purpose of this study is to examine the relationship between baseline 10-2 VF loss and future 24-2 VF loss. Materials and Methods: Subjects were participating in a prospective longitudinal study within a VA Medical Center outpatient eye clinic. Eligibility required 2 good quality baseline 10-2 VF tests followed by a minimum of 5 good quality 24-2 VF tests over at least 3 years. Longitudinal 24-2 VF testing was completed every 4–6 months after baseline 10-2 testing. Mixed model regression analyses and Cox Proportional Hazard regression analyses were completed to identify predictors of 24-2 mean deviation change rate and new VF loss events. Results: We studied 394 eyes of 202 subjects (119 primary open angle glaucoma and 83 glaucoma suspect). Over 6.7 (±1.5) years, 9.9 (±2.3) good quality 24-2 VF tests were completed. In mixed model regression analyses, baseline variables that predicted faster rate of 24-2 VF loss in order of strength of association were presence of baseline 10-2 VF defect, lower 24-2 mean deviation, and higher age. When analyses were completed without 10-2 variables, predictive capability of the model was reduced compared with when 10-2 variables were included. In Cox Proportional Regression analyses evaluating progression events, baseline 10-2 VF defect demonstrated the largest hazard ratio (22 times greater risk for developing future VF loss event in eyes with vs. without baseline 10-2 VF loss). Conclusions: Baseline 10-2 VF defect was the most effective predictor of subsequent 24-2 VF progression in this study. These findings imply that presence of baseline 10-2 VF loss may provide unique value for predicting future glaucoma progression.
- 1 February 2018
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (2) , 106-112
Differentiating Occult Branch Retinal Artery Occlusion from Primary Open‐angle Glaucoma
SIGNIFICANCE: Clinical findings in occult branch retinal artery occlusion (BRAO) can mimic those of primary open‐angle glaucoma (POAG). Because management of these conditions substantially differs, accurate diagnosis is crucial. Our comparative analysis indicates that specific macular thickness variables reliably differentiate these conditions and that macular scanning may enhance routine glaucoma evaluation. PURPOSE: The aim of this study was to identify clinical factors that reliably and efficiently identify occult BRAO masquerading as POAG. METHODS: All subjects had comprehensive eye examinations including measurements of retinal nerve fiber layer and macular thickness (MT) using spectral‐domain optical coherence tomography (SD‐OCT). All subjects were asymptomatic for previous acute vision loss episodes, had optic nerve appearances suggestive of glaucoma, and exhibited SD‐OCT retinal nerve fiber layer thinning with corresponding visual field loss. Macular thickness scans were divided into 64 individual thickness blocks with thin MT blocks defined by the lower 99% confidence interval from a group of normal eyes. We defined BRAO by the presence of regional inner retinal thinning with lack of inner‐layer stratification on macular SD‐OCT b‐scan images that spatially corresponded with arteriolar distribution and visual field loss location. Primary open‐angle glaucoma eyes were selected to match the BRAO eyes by age and disease severity. Pairwise and receiver operating characteristic curve analyses were used to compare occult BRAO and POAG eyes. RESULTS: Compared with POAG (n = 52), occult BRAO eyes (n = 11) demonstrated lower cup‐disc ratio, greater intereye and intraeye (superior vs. inferior) MT asymmetry, and higher frequency of thin MT blocks (<200 μm). Area under the receiver operating characteristic curve (AUC) for differentiating these conditions was highest for intraeye MT asymmetry (AUC = 0.990 [95% confidence interval, 0.925 to 1.000]) and number of thin MT blocks (AUC = 0.993 [95% confidence interval, 0.929 to 1.000]). CONCLUSIONS: Macular thickness parameters provided accurate and efficient diagnostic capability in this study. Considering the clinical implications of inaccurate diagnosis, macular scanning may be important in baseline glaucoma evaluation.
- 1 February 2018
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (2) , 106-112
Differentiating Occult Branch Retinal Artery Occlusion from Primary Open‐angle Glaucoma
SIGNIFICANCE: Clinical findings in occult branch retinal artery occlusion (BRAO) can mimic those of primary open‐angle glaucoma (POAG). Because management of these conditions substantially differs, accurate diagnosis is crucial. Our comparative analysis indicates that specific macular thickness variables reliably differentiate these conditions and that macular scanning may enhance routine glaucoma evaluation. PURPOSE: The aim of this study was to identify clinical factors that reliably and efficiently identify occult BRAO masquerading as POAG. METHODS: All subjects had comprehensive eye examinations including measurements of retinal nerve fiber layer and macular thickness (MT) using spectral‐domain optical coherence tomography (SD‐OCT). All subjects were asymptomatic for previous acute vision loss episodes, had optic nerve appearances suggestive of glaucoma, and exhibited SD‐OCT retinal nerve fiber layer thinning with corresponding visual field loss. Macular thickness scans were divided into 64 individual thickness blocks with thin MT blocks defined by the lower 99% confidence interval from a group of normal eyes. We defined BRAO by the presence of regional inner retinal thinning with lack of inner‐layer stratification on macular SD‐OCT b‐scan images that spatially corresponded with arteriolar distribution and visual field loss location. Primary open‐angle glaucoma eyes were selected to match the BRAO eyes by age and disease severity. Pairwise and receiver operating characteristic curve analyses were used to compare occult BRAO and POAG eyes. RESULTS: Compared with POAG (n = 52), occult BRAO eyes (n = 11) demonstrated lower cup‐disc ratio, greater intereye and intraeye (superior vs. inferior) MT asymmetry, and higher frequency of thin MT blocks (<200 μm). Area under the receiver operating characteristic curve (AUC) for differentiating these conditions was highest for intraeye MT asymmetry (AUC = 0.990 [95% confidence interval, 0.925 to 1.000]) and number of thin MT blocks (AUC = 0.993 [95% confidence interval, 0.929 to 1.000]). CONCLUSIONS: Macular thickness parameters provided accurate and efficient diagnostic capability in this study. Considering the clinical implications of inaccurate diagnosis, macular scanning may be important in baseline glaucoma evaluation.
- 1 December 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (9) , 666-673
Repeatability and Reproducibility for Intraocular Pressure Measurement by Dynamic Contour, Ocular Response Analyzer, and Goldmann Applanation Tonometry
To evaluate and compare the intraocular pressure measurement variability between Goldmann applanation tonometry (GAT), Pascal dynamic contour tonometry (DCT), and ocular response analyzer (ORA) tonometry. Subjects were prospectively recruited from consecutive Albuquerque VA Medical Center eye clinic patients that were previously diagnosed with ocular hypertension, glaucoma suspect, primary open-angle, or normal pressure glaucoma. Two sets of intraocular pressure measurements (3-4 ORA, 2 DCT, and 2 GAT) were obtained approximately 15 minutes apart. Each set was obtained by 1 of 2 examiners using random examiner sequences. ORA was measured first in both eyes, followed by either DCT or GAT, which were obtained in random order. Repeatability was assessed by examining variability of consecutive measurements by the same examiner, and reproducibility was examined by assessing variability between the first and second measurement sets. One hundred and twenty eyes of 60 subjects were included. Mean age was 64.1+/-9.6 years and 58/60 (97%) were male. Intraobserver repeatability was highest for GAT, followed closely by DCT, and then ORA. Intersession reproducibility was similar for all methods, although a tonographic effect may have corrupted GAT and DCT reproducibility results. We found no repeatability or reproducibility differences between eyes, between examiners, or between measurement sets. Although some intermethod variability differences were identified, all 3 methods in this study demonstrated clinically acceptable measurement repeatability and reproducibility. This result, in conjunction with the finding that variability was not different between eyes, examiners, or measurement sets, suggests that DCT and ORA are reliable enough to be clinically useful.
- 1 December 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (9) , 666-673
Repeatability and Reproducibility for Intraocular Pressure Measurement by Dynamic Contour, Ocular Response Analyzer, and Goldmann Applanation Tonometry
To evaluate and compare the intraocular pressure measurement variability between Goldmann applanation tonometry (GAT), Pascal dynamic contour tonometry (DCT), and ocular response analyzer (ORA) tonometry. Subjects were prospectively recruited from consecutive Albuquerque VA Medical Center eye clinic patients that were previously diagnosed with ocular hypertension, glaucoma suspect, primary open-angle, or normal pressure glaucoma. Two sets of intraocular pressure measurements (3-4 ORA, 2 DCT, and 2 GAT) were obtained approximately 15 minutes apart. Each set was obtained by 1 of 2 examiners using random examiner sequences. ORA was measured first in both eyes, followed by either DCT or GAT, which were obtained in random order. Repeatability was assessed by examining variability of consecutive measurements by the same examiner, and reproducibility was examined by assessing variability between the first and second measurement sets. One hundred and twenty eyes of 60 subjects were included. Mean age was 64.1+/-9.6 years and 58/60 (97%) were male. Intraobserver repeatability was highest for GAT, followed closely by DCT, and then ORA. Intersession reproducibility was similar for all methods, although a tonographic effect may have corrupted GAT and DCT reproducibility results. We found no repeatability or reproducibility differences between eyes, between examiners, or between measurement sets. Although some intermethod variability differences were identified, all 3 methods in this study demonstrated clinically acceptable measurement repeatability and reproducibility. This result, in conjunction with the finding that variability was not different between eyes, examiners, or measurement sets, suggests that DCT and ORA are reliable enough to be clinically useful.
- 1 June 2008
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (6) , 463-470
Ocular Response Analyzer in Subjects with and without Glaucoma
Purpose.: The Ocular Response Analyzer (ORA) is a newly introduced tonometer that uniquely measures and then integrates corneal biomechanical data into its intraocular pressure (IOP) estimates in an effort to improve accuracy of IOP assessment. This study was devised to investigate whether ORA‐derived IOP and corneal biomechanical variables might be useful in discriminating between subjects with and without primary open‐angle glaucoma (GLC). Methods.: All patients seen in the Albuquerque VAMC eye clinic over a 10‐week period who demonstrated acceptable ORA signal profiles were retrospectively identified. In subjects classified as normal (NML), ocular hypertension (OH), glaucoma suspect (GS), and GLC, the following variables were compared: age, ethnicity, Goldmann IOP, central corneal thickness (CCT), and ORA‐derived data: Goldmann‐correlated IOP (IOPg), corneal‐compensated IOP (IOPcc), corneal resistance factor (CRF), corneal hysteresis (CH), and difference between IOPcc and IOPg (DIOP; IOPcc − IOPg). Results.: Right eyes in 71 NML, 58 OH, 70 GS, and 99 GLC subjects were studied. Using analysis of variance, higher mean age, higher mean DIOP, and lower mean CH were found in the GLC group compared with OH, GS, and NML groups. In multivariate regression analyses, factors that independently discriminated between groups were: age, IOPcc, and DIOP (GLC vs. NML); age and IOPcc (GLC vs. GS); age and CRF (GLC vs. OH). When DIOP was left out of the models, CH replaced DIOP in the GLC vs. NML analysis with nearly equal statistical power. Conclusions.: Our results suggest that ORA‐generated parameters may be useful for differentiating subjects with and without GLC. Furthermore, the discriminatory power of each ORA variable seems to depend on the diagnostic groups that are being compared. Finally, our findings also suggest that measured IOP may be significantly underestimated in glaucoma patients compared with non‐glaucoma patients.
- 1 June 2008
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (6) , 463-470
Ocular Response Analyzer in Subjects with and without Glaucoma
Purpose.: The Ocular Response Analyzer (ORA) is a newly introduced tonometer that uniquely measures and then integrates corneal biomechanical data into its intraocular pressure (IOP) estimates in an effort to improve accuracy of IOP assessment. This study was devised to investigate whether ORA‐derived IOP and corneal biomechanical variables might be useful in discriminating between subjects with and without primary open‐angle glaucoma (GLC). Methods.: All patients seen in the Albuquerque VAMC eye clinic over a 10‐week period who demonstrated acceptable ORA signal profiles were retrospectively identified. In subjects classified as normal (NML), ocular hypertension (OH), glaucoma suspect (GS), and GLC, the following variables were compared: age, ethnicity, Goldmann IOP, central corneal thickness (CCT), and ORA‐derived data: Goldmann‐correlated IOP (IOPg), corneal‐compensated IOP (IOPcc), corneal resistance factor (CRF), corneal hysteresis (CH), and difference between IOPcc and IOPg (DIOP; IOPcc − IOPg). Results.: Right eyes in 71 NML, 58 OH, 70 GS, and 99 GLC subjects were studied. Using analysis of variance, higher mean age, higher mean DIOP, and lower mean CH were found in the GLC group compared with OH, GS, and NML groups. In multivariate regression analyses, factors that independently discriminated between groups were: age, IOPcc, and DIOP (GLC vs. NML); age and IOPcc (GLC vs. GS); age and CRF (GLC vs. OH). When DIOP was left out of the models, CH replaced DIOP in the GLC vs. NML analysis with nearly equal statistical power. Conclusions.: Our results suggest that ORA‐generated parameters may be useful for differentiating subjects with and without GLC. Furthermore, the discriminatory power of each ORA variable seems to depend on the diagnostic groups that are being compared. Finally, our findings also suggest that measured IOP may be significantly underestimated in glaucoma patients compared with non‐glaucoma patients.
- 1 July 2006
- Published by Wiley in Optometry and Vision Science
- Vol. 83 (7) , 516-519
Relationship Between Asymmetric Central Corneal Thickness and Glaucomatous Visual Field Loss Within the Same Patient
Purpose.: Considering that thinner central corneal thickness (CCT) has been identified as a significant glaucoma risk factor, this study was designed to determine whether patients with glaucoma with asymmetric CCT demonstrate greater visual field loss in their thinner CCT eye compared with their thicker CCT eye. Methods.: Patient logs were used to retrospectively identify patients with primary open‐angle glaucoma (POAG) and patients with normal‐tension glaucoma (NTG) with CCT asymmetry of 10 μm or greater. Severity of glaucoma was determined using Advanced Glaucoma Intervention Study (AGIS) visual field scoring criteria. After statistical analysis was used to compare all thinner CCT eyes vs. corresponding thicker CCT eyes, subjects with worse visual field loss in the thinner CCT eye were compared with subjects with worse visual field loss in the thicker CCT eye. Subanalysis was then completed using only subjects with CCT asymmetry of 15 μm or greater. Results.: In the 52 subjects who met all criteria for study inclusion, mean AGIS score was significantly higher in the thinner CCT eyes compared with the thicker CCT eyes. Subjects with higher AGIS score in their thinner CCT eye outnumbered subjects with higher AGIS score in their thicker CCT eye, with the differences approaching statistical significance in the full sample (p = 0.06) and achieving significance when analysis was limited to subjects with CCT asymmetry of 15 μm or greater (p = 0.001). Multivariate logistic regression analysis identified thinner CCT as the primary risk factor associated with higher AGIS score in subjects with CCT asymmetry of 15 μm or greater. Conclusion.: These results correspond to prior reports implicating CCT as an independent risk factor for glaucomatous visual field loss. When significant CCT asymmetry is present in patients with glaucoma, the thinner CCT eye is at greater risk for more advanced visual field loss. The underlying nature of this increased risk is unknown, but further study into structural vulnerabilities associated with thinner CCT seems justified.
- 1 July 2006
- Published by Wiley in Optometry and Vision Science
- Vol. 83 (7) , 516-519
Relationship Between Asymmetric Central Corneal Thickness and Glaucomatous Visual Field Loss Within the Same Patient
Purpose.: Considering that thinner central corneal thickness (CCT) has been identified as a significant glaucoma risk factor, this study was designed to determine whether patients with glaucoma with asymmetric CCT demonstrate greater visual field loss in their thinner CCT eye compared with their thicker CCT eye. Methods.: Patient logs were used to retrospectively identify patients with primary open‐angle glaucoma (POAG) and patients with normal‐tension glaucoma (NTG) with CCT asymmetry of 10 μm or greater. Severity of glaucoma was determined using Advanced Glaucoma Intervention Study (AGIS) visual field scoring criteria. After statistical analysis was used to compare all thinner CCT eyes vs. corresponding thicker CCT eyes, subjects with worse visual field loss in the thinner CCT eye were compared with subjects with worse visual field loss in the thicker CCT eye. Subanalysis was then completed using only subjects with CCT asymmetry of 15 μm or greater. Results.: In the 52 subjects who met all criteria for study inclusion, mean AGIS score was significantly higher in the thinner CCT eyes compared with the thicker CCT eyes. Subjects with higher AGIS score in their thinner CCT eye outnumbered subjects with higher AGIS score in their thicker CCT eye, with the differences approaching statistical significance in the full sample (p = 0.06) and achieving significance when analysis was limited to subjects with CCT asymmetry of 15 μm or greater (p = 0.001). Multivariate logistic regression analysis identified thinner CCT as the primary risk factor associated with higher AGIS score in subjects with CCT asymmetry of 15 μm or greater. Conclusion.: These results correspond to prior reports implicating CCT as an independent risk factor for glaucomatous visual field loss. When significant CCT asymmetry is present in patients with glaucoma, the thinner CCT eye is at greater risk for more advanced visual field loss. The underlying nature of this increased risk is unknown, but further study into structural vulnerabilities associated with thinner CCT seems justified.
- 31 March 2006
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 77 (3) , 134-140
Central corneal thickness and normal tension glaucoma: A cross-sectional study
- 31 March 2006
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 77 (3) , 134-140
Central corneal thickness and normal tension glaucoma: A cross-sectional study
- 31 January 2006
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 77 (1) , 40-46
Relationship between central corneal thickness and severity of glaucomatous visual field loss in a primary care population
- 31 January 2006
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 77 (1) , 40-46
Relationship between central corneal thickness and severity of glaucomatous visual field loss in a primary care population
- 1 April 2005
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 76 (4) , 228-238
The relationship between central corneal thickness-adjusted intraocular pressure and glaucomatous visual-field loss
- 1 April 2005
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 76 (4) , 228-238
The relationship between central corneal thickness-adjusted intraocular pressure and glaucomatous visual-field loss
- 1 January 2004
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 75 (1) , 26-32
Correspondence of Tono–Pen® intraocular pressure measurements performed at the central cornea and mid-peripheral cornea
- 1 January 2004
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 75 (1) , 26-32
Correspondence of Tono–Pen® intraocular pressure measurements performed at the central cornea and mid-peripheral cornea