Davide Iannuzzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Davide Iannuzzi has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
S. de Man
Department of Physics and Astronomy and LaserLaB VU University Amsterdam Amsterdam The Netherlands
9 shared publicationsK. Heeck
Department of Physics and Astronomy and LaserLaB VU University Amsterdam Amsterdam The Netherlands
8 shared publications- Anne-Christine Davis
Cambridge University
2 shared publications - Carsten van de Bruck
Department of Applied Mathematics School of Mathematics and Statistics University of Sheffield Houndsfield Road S3 7RH Sheffield UK
2 shared publications D. Chavan
Department of Physics and Astronomy and LaserLaB Amsterdam, VU University, Amsterdam, The Netherlands
2 shared publications- Douglas J. Shaw
Astronomy Unit Queen Mary University of London Mile End Road E1 4NS London United Kingdom
2 shared publications
Latest Publications
- Open Access
Viscoelastic mapping of mouse brain tissue: relation to structure and age
There is growing evidence that mechanical factors affect brain functioning. However, brain components responsible for regulating the physiological mechanical environment and causing mechanical alterations during maturation are not completely understood. To determine the relationship between structure and stiffness of the brain tissue, we performed high resolution viscoelastic mapping by dynamic indentation of hippocampus and cerebellum of juvenile brain, and quantified relative area covered by immunohistochemical staining of NeuN (neurons), GFAP (astrocytes), Hoechst (nuclei), MBP (myelin), NN18 (axons) of juvenile and adult mouse brain slices. When compared the mechanical properties of juvenile mouse brain slices with previously obtained data on adult slices, the latter was ~ 20-150% stiffer, which correlates with an increase in the relative area covered by astrocytes. Heterogeneity within the slice, in terms of storage modulus, correlates negatively with the relative area of nuclei and neurons, as well as myelin and axons, while the relative area of astrocytes correlates positively. Several linear regression models are suggested to predict the mechanical properties of the brain tissue based on immunohistochemical stainings.
Open AccessViscoelastic mapping of mouse brain tissue: relation to structure and age
There is growing evidence that mechanical factors affect brain functioning. However, brain components responsible for regulating the physiological mechanical environment and causing mechanical alterations during maturation are not completely understood. To determine the relationship between structure and stiffness of the brain tissue, we performed high resolution viscoelastic mapping by dynamic indentation of hippocampus and cerebellum of juvenile brain, and quantified relative area covered by immunohistochemical staining of NeuN (neurons), GFAP (astrocytes), Hoechst (nuclei), MBP (myelin), NN18 (axons) of juvenile and adult mouse brain slices. When compared the mechanical properties of juvenile mouse brain slices with previously obtained data on adult slices, the latter was ~ 20-150% stiffer, which correlates with an increase in the relative area covered by astrocytes. Heterogeneity within the slice, in terms of storage modulus, correlates negatively with the relative area of nuclei and neurons, as well as myelin and axons, while the relative area of astrocytes correlates positively. Several linear regression models are suggested to predict the mechanical properties of the brain tissue based on immunohistochemical stainings.
- Open Access
Measurement of the Casimir force with a ferrule-top sensor
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold coated sphere and a gold coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require any optical triangulation readout) and to the absence of electronics on the sensing head, the instrument represents a significant step ahead for future studies of the Casimir effect under engineered conditions, where the intervening medium or the environmental conditions might be unsuitable for the use of more standard setups.
Open AccessMeasurement of the Casimir force with a ferrule-top sensor
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold coated sphere and a gold coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require any optical triangulation readout) and to the absence of electronics on the sensing head, the instrument represents a significant step ahead for future studies of the Casimir effect under engineered conditions, where the intervening medium or the environmental conditions might be unsuitable for the use of more standard setups.
- 1 February 2011
- Published by IOP Publishing in New Journal of Physics
- Vol. 13 (2) , 023027
Measurement of the Casimir force with a ferrule-top sensor
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold-coated sphere and a gold-coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require any optical triangulation readout) and to the absence of electronics on the sensing head, the instrument represents a significant step forward for future studies of the Casimir effect under engineered conditions, where the intervening medium or the environmental conditions might be unsuitable for the use of more standard setups.
- 1 February 2011
- Published by IOP Publishing in New Journal of Physics
- Vol. 13 (2) , 023027
Measurement of the Casimir force with a ferrule-top sensor
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold-coated sphere and a gold-coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require any optical triangulation readout) and to the absence of electronics on the sensing head, the instrument represents a significant step forward for future studies of the Casimir effect under engineered conditions, where the intervening medium or the environmental conditions might be unsuitable for the use of more standard setups.
- Open Access
Halving the Casimir force with conductive oxides: experimental details
This work is an extended version of a paper published last year in Physical Review Letters [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold coated sphere and a plate coated with either gold or an indium-tin-oxide (ITO) layer. The experiment, which was performed in air, showed that ITO is sufficiently conducting to prevent charge accumulation, but still transparent enough to halve the Casimir attraction when compared to gold. Here, we report all the experimental details that, due to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a new technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.
Open AccessHalving the Casimir force with conductive oxides: experimental details
This work is an extended version of a paper published last year in Physical Review Letters [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold coated sphere and a plate coated with either gold or an indium-tin-oxide (ITO) layer. The experiment, which was performed in air, showed that ITO is sufficiently conducting to prevent charge accumulation, but still transparent enough to halve the Casimir attraction when compared to gold. Here, we report all the experimental details that, due to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a new technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.
- 16 December 2010
- Published by American Physical Society (APS) in Physical Review A
- Vol. 82 (6)
Halving the Casimir force with conductive oxides: Experimental details
This work is an extended version of a paper published previously [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold-coated sphere and a plate coated with either gold or an indium tin oxide (I\phantom,TO) layer. The experiment, which was performed in air, showed that I\phantom,TO conducts sufficiently to prevent charge accumulation but is still transparent enough to halve the Casimir attraction when compared to gold. Here we report all the experimental details that, owing to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.
- 16 December 2010
- Published by American Physical Society (APS) in Physical Review A
- Vol. 82 (6)
Halving the Casimir force with conductive oxides: Experimental details
This work is an extended version of a paper published previously [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold-coated sphere and a plate coated with either gold or an indium tin oxide (I\phantom,TO) layer. The experiment, which was performed in air, showed that I\phantom,TO conducts sufficiently to prevent charge accumulation but is still transparent enough to halve the Casimir attraction when compared to gold. Here we report all the experimental details that, owing to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.
- 13 December 2010
- Published by Wiley in Journal of Microscopy
- Vol. 242 (1) , 10-14
Fibre-top atomic force microscope probe with optical near-field detection capabilities
We present a fibre-top probe fabricated by carving a tipped cantilever on an optical fibre, with the tip machined in correspondence of the fibre core. When approached to an optical prism illuminated under total internal reflection conditions, the tip of the cantilever detects the optical tunnelling signal, while the light coupled from the opposite end of the fibre measures the deflection of the cantilever. Our results suggest that fibre-top technology can be used for the development of a new generation of hybrid probes that can combine atomic force microscopy with scanning near field optical microscopy. © 2010 The Authors Journal of Microscopy © 2010 Royal Microscopical Society
- 13 December 2010
- Published by Wiley in Journal of Microscopy
- Vol. 242 (1) , 10-14
Fibre-top atomic force microscope probe with optical near-field detection capabilities
We present a fibre-top probe fabricated by carving a tipped cantilever on an optical fibre, with the tip machined in correspondence of the fibre core. When approached to an optical prism illuminated under total internal reflection conditions, the tip of the cantilever detects the optical tunnelling signal, while the light coupled from the opposite end of the fibre measures the deflection of the cantilever. Our results suggest that fibre-top technology can be used for the development of a new generation of hybrid probes that can combine atomic force microscopy with scanning near field optical microscopy. © 2010 The Authors Journal of Microscopy © 2010 Royal Microscopical Society
- 1 December 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (12) , 123702
Ferrule-top atomic force microscope
Ferrule-top cantilevers are a new generation of all-optical miniaturized devices for utilization in liquids, harsh environments, and small volumes [G. Gruca et al., Meas. Sci. Technol. 21, 094033 (2010)]. They are obtained by carving the end of a ferruled fiber in the form of a mechanical beam. Light coupled from the opposite side of the fiber allows detection of cantilever deflections. In this paper, we demonstrate that ferrule-top cantilevers can be used to develop ultra compact AFMs for contact mode imaging in air and in liquids with sensitivity comparable to that of commercial AFMs. The probes do not require any alignment procedure and are easy to handle, favoring applications also outside research laboratories.
- 1 December 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (12) , 123702
Ferrule-top atomic force microscope
Ferrule-top cantilevers are a new generation of all-optical miniaturized devices for utilization in liquids, harsh environments, and small volumes [G. Gruca et al., Meas. Sci. Technol. 21, 094033 (2010)]. They are obtained by carving the end of a ferruled fiber in the form of a mechanical beam. Light coupled from the opposite side of the fiber allows detection of cantilever deflections. In this paper, we demonstrate that ferrule-top cantilevers can be used to develop ultra compact AFMs for contact mode imaging in air and in liquids with sensitivity comparable to that of commercial AFMs. The probes do not require any alignment procedure and are easy to handle, favoring applications also outside research laboratories.
- 14 June 2010
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 104 (24) , 241101
Tuning the Mass of Chameleon Fields in Casimir Force Experiments
We have calculated the chameleon pressure between two parallel plates in the presence of an intervening medium that affects the mass of the chameleon field. As intuitively expected, the gas in the gap weakens the chameleon interaction mechanism with a screening effect that increases with the plate separation and with the density of the intervening medium. This phenomenon might open up new directions in the search of chameleon particles with future long-range Casimir force experiments.
- 14 June 2010
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 104 (24) , 241101
Tuning the Mass of Chameleon Fields in Casimir Force Experiments
We have calculated the chameleon pressure between two parallel plates in the presence of an intervening medium that affects the mass of the chameleon field. As intuitively expected, the gas in the gap weakens the chameleon interaction mechanism with a screening effect that increases with the plate separation and with the density of the intervening medium. This phenomenon might open up new directions in the search of chameleon particles with future long-range Casimir force experiments.
- 27 April 2010
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 28 (3) , C4A25-C4A29
Contact potentials in Casimir force setups: An experimental analysis
The authors present an extensive study of the contact potential difference, V-0, between a gold coated sphere and a gold coated plate kept in air at submicron separation. The data confirm that in ambient conditions, V-0 depends on both time and separation. They discuss the origin of the time dependence of V-0 and elaborate on its functional dependence on separation, d. The data strongly support a log(d) hypothesis but also show that in air this description is not quite complete. These effects might have important implications in the realm of Casimir force experiments. (C) 2010 American Vacuum Society. [DOI: 10.1116/1.3316583
- 27 April 2010
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 28 (3) , C4A25-C4A29
Contact potentials in Casimir force setups: An experimental analysis
The authors present an extensive study of the contact potential difference, V-0, between a gold coated sphere and a gold coated plate kept in air at submicron separation. The data confirm that in ambient conditions, V-0 depends on both time and separation. They discuss the origin of the time dependence of V-0 and elaborate on its functional dependence on separation, d. The data strongly support a log(d) hypothesis but also show that in air this description is not quite complete. These effects might have important implications in the realm of Casimir force experiments. (C) 2010 American Vacuum Society. [DOI: 10.1116/1.3316583
- Open Access
Tuning the Mass of Chameleon Fields in Casimir Force Experiments
We have calculated the chameleon pressure between two parallel plates in the presence of an intervening medium that affects the mass of the chameleon field. As intuitively expected, the gas in the gap weakens the chameleon interaction mechanism with a screening effect that increases with the plate separation and with the density of the intervening medium. This phenomenon might open up new directions in the search of chameleon particles with future long range Casimir force experiments.
Open AccessTuning the Mass of Chameleon Fields in Casimir Force Experiments
We have calculated the chameleon pressure between two parallel plates in the presence of an intervening medium that affects the mass of the chameleon field. As intuitively expected, the gas in the gap weakens the chameleon interaction mechanism with a screening effect that increases with the plate separation and with the density of the intervening medium. This phenomenon might open up new directions in the search of chameleon particles with future long range Casimir force experiments.