OHOlivier Haeberlé

Olivier Haeberlé

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Olivier Haeberlé has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hyperspectral tomographic diffractive microscopy: Development and applications

    by Leonardo Pestana Legori, Carlos Alberto Chacón Ávila, Matthieu Debailleul, Nicolas Verrier, Olivier Haeberlé

    Tomographic Diffractive Microscopy (TDM) provides label‐free three‐dimensional imaging of transparent samples with resolution surpassing confocal limits. At IRIMAS, successive instrumental developments since 2009 have enhanced TDM capabilities through transmission, reflection, isotropic, polarisation‐sensitive, and dual‐view configurations. However, conventional single‐wavelength TDM cannot distinguish chemically distinct structures with similar optical properties at the measurement wavelength. This article presents the development of hyperspectral TDM, which exploits wavelength‐dependent optical properties to provide chemical specificity through 3D spectroscopic characterisation. We describe the physical principles underlying TDM reconstruction, detail our integration of a supercontinuum source for multi‐wavelength capability, and outline applications in biomedical and material imaging. Our structured development roadmap encompasses instrumentation, calibration, hyperspectral synthesis, and AI‐enhanced reconstruction.

  • Open Access

    Dual-view tomographic diffraction microscopy

    by Carlos Alberto Chacón Ávila, Nicolas Verrier, Matthieu Debailleul, Bruno Colicchio, Olivier Haeberlé

    We present a dual-view transmission tomographic diffraction microscopy system for quantitative 3D imaging of complex refractive index in transparent biological samples. By combining acquisitions from two opposite directions, our system captures complementary information. A frequency-content-based fusion strategy is used to merge the two reconstructed volumes, mitigating signal attenuation and reducing artifacts generated by depth image degradation, resulting in improved image quality and volumetric resolution.


  • Self-Written High-Efficiency Single-Mode Optical Link Using a Single Near-Infrared Photopolymerization Step

    by Nessim Jebali, Céline Molinaro, Julien Roul, Julie Jermann, Jean-Baptiste Doucet, Benjamin Reig, Serge Monneret, Olivier Haeberlé, Olivier Soppera, Véronique Bardinal

    We present a method for fabricating a self-written waveguide (SWW) between two optical fibers that are single-mode (SM) at 850 nm (780HP/ core diameter: 4.4 μm). The basic principle consists in exposing an acrylic photopolymer formulation sensitive in the near-infrared range (NIR) to a laser beam transmitted simultaneously from both fibers placed face to face, to build a continuous, flexible and self-aligned optical link. The specificity of the presented process (NIR-SM-SWW) lies in the use of a writing wavelength identical to that intended for single-mode propagation in the fibers. This enables the creation in a single step of a SWW directly adapted to the fundamental mode to be transmitted. A precise pre-positioning stage is used to optimize the process. For best photochemical conditions, a coupling efficiency as high as 82 % (-0.86 dB loss) is demonstrated for a 300 μm-long link. The effect of fiber-to-fiber axial and lateral distances is also investigated to estimate the propagation loss and misalignment tolerance, respectively. In addition, measurements performed by quantitative phase optical microscopy indicate a homogeneous index profile in the guide. Using these data, optical modeling is performed and compared to experiments, confirming that a high efficiency SM link is actually fabricated, without the need for further fabrication of an external cladding. This method could therefore be easily applied to the SM connection of a SM VCSEL (vertical-cavity surface-emitting laser) to a SM fiber, which is of major interest for the development of compact optical communications and instrumentation systems.


  • Open Access

    Recent Advances and Current Trends in Transmission Tomographic Diffraction Microscopy

    by Nicolas Verrier, Matthieu Debailleul, Olivier Haeberlé

    Optical microscopy techniques are among the most used methods in biomedical sample characterization. In their more advanced realization, optical microscopes demonstrate resolution down to the nanometric scale. These methods rely on the use of fluorescent sample labeling in order to break the diffraction limit. However, fluorescent molecules’ phototoxicity or photobleaching is not always compatible with the investigated samples. To overcome this limitation, quantitative phase imaging techniques have been proposed. Among these, holographic imaging has demonstrated its ability to image living microscopic samples without staining. However, for a 3D assessment of samples, tomographic acquisitions are needed. Tomographic Diffraction Microscopy (TDM) combines holographic acquisitions with tomographic reconstructions. Relying on a 3D synthetic aperture process, TDM allows for 3D quantitative measurements of the complex refractive index of the investigated sample. Since its initial proposition by Emil Wolf in 1969, the concept of TDM has found a lot of applications and has become one of the hot topics in biomedical imaging. This review focuses on recent achievements in TDM development. Current trends and perspectives of the technique are also discussed.


  • Jones tomographic diffractive microscopy with a polarized array sensor

    by Asemare Mengistie Taddese, Mohamed Lo, Nicolas Verrier, Matthieu Debailleul, Olivier Haeberlé

    Tomographic diffractive microscopy (TDM) based on scalar light-field approximation is widely implemented. Samples exhibiting anisotropic structures, however, necessitate accounting for the vectorial nature of light, leading to 3-D quantitative polarimetric imaging. In this work, we have developed a high-numerical aperture (at both illumination and detection) Jones TDM system, with detection multiplexing via a polarized array sensor (PAS), for imaging optically birefringent samples at high resolution. The method is first studied through image simulations. To validate our setup, an experiment using a sample containing both birefringent and non-birefringent objects is performed. Araneus diadematus spider silk fiber and Pinna nobilis oyster shell crystals are finally studied, allowing us to assess both birefringence and fast-axis orientation maps.


  • Toward Multimodal Functionalized Markerless Imaging: Extensions of Tomographic Diffraction Microscopy

    by Nicolas Verrier, Matthieu Debailleul, Olivier Haeberlé

    Tomographic Diffraction Microscopy (TDM) is an invaluable tool in markerless 3D imaging of biosamples. However, TDM lacks from information selectivity compared to other techniques. This presentation will discuss extensions of TDM to other imaging contrasts, which, combined with the refractive index information, allows bringing back selectivity.

  • Open Access

    Behaviour and onset of low-dimensional chaos with a periodically varying loss in single-mode homogeneously broadened laser

    by Samia Ayadi, Matthieu Debailleul, Olivier Haeberlé

    In this work, we numerically study the behaviour of the single-mode homogeneously broadened laser versus a large perturbation of the steady state. Periodic behaviour develops for suitable values of the ratio of the population decay rates ℘ \wp , which has been analytically predicted by the analytical approach developed in the previous works, and for a pumping parameter 2 C 2C situated below and above the instability threshold 2 C 2 th 2{C}_{2{\rm{th}}} . We here show that the adiabatic elimination of the polarisation with sinusoidal time-dependent perturbation of the cavity rate leads the single-mode homogenously broadened laser to exhibit chaotic emission, if the frequency ω \omega is equal to the natural frequency Δ P {\Delta }_{P} . Increasing the pumping parameter 2 C 2C , the laser undergoes a period-doubling sequence. This cascade of period doubling drives the laser towards chaos. We also propose a reformulation of our analytical procedure, which describes the self-pulsing regime of the single-mode homogeneously broadened laser. We here report that asymmetric aspect that appears in the time evolution of the electric field is due to phase effects between the electric field components.

  • Optimal dense and random addressing design of emissive points in a retinal projection device

    by Fabian Rainouard, Matthias Colard, Olivier Haeberlé, Edouard Oudet, Christophe Martinez

    One of the big challenges of Augmented Reality (AR) is to create ergonomic smart glasses. Our laboratory proposes an unconventional concept of AR glasses based on self-focusing of multiple beams into the eye. The device comprises a dense electrode network that allows extracting light from a dense waveguide network at the intersections points. Each beam emitted at these points is reflected by a holographic element that directs light towards the eye with a proper angular direction. The image pixels are created on the retina by the interferences of various beam distributions. This paper presents a method to optimize the design of waveguides and electrodes to increase the number of pixels on the final image. Our method considers a first waveguide (resp. electrode) as a curve described by a succession of segments with a unique absolute angle crossing a horizontal (resp. vertical) axe. The other waveguides (resp. electrodes) are created by the translation of the curves so that the minimal distance between two curves is equal to a fixed value. We use the B-Splines mathematical model to approximate the succession of segments. An iterative method adapted to B-Splines allows calculating the intersections between waveguides and electrodes. An Emissive Point Distribution (EPD) is obtained by selecting random groups of waveguides and electrodes. Each EPD forms one pixel onto the retina. The Point Spread Function (PSF) of this EPD characterizes the self-focusing efficiency. We calculate the Signal-to-Noise-Ratio of each EPD to evaluate the quality of the whole self-focusing process and we compare it to the Airy function. Our new mathematical model improves by a factor 3.5 the number of pixels for an equivalent SNR in comparison to the model we previously used.


  • GSURE criterion for unsupervised regularized reconstruction in tomographic diffractive microscopy

    by Laurence Denneulin, Fabien Momey, Dylan Brault, Matthieu Debailleul, Asemare Taddese, Nicolas Verrier, Olivier Haeberle

    We propose an unsupervised regularized inversion method for reconstruction of the 3D refractive index map of a sample in tomographic diffractive microscopy. It is based on the minimization of the generalized Stein’s unbiased risk estimator (GSURE) to automatically estimate optimal values for the hyperparameters of one or several regularization terms (sparsity, edge-preserving smoothness, total variation). We evaluate the performance of our approach on simulated and experimental limited-view data. Our results show that GSURE is an efficient criterion to find suitable regularization weights, which is a critical task, particularly in the context of reducing the amount of required data to allow faster yet efficient acquisitions and reconstructions.


  • Optimizing sample illumination scanning for reflection and 4Pi tomographic diffractive microscopy

    by Asemare Mengistie Taddese, Nicolas Verrier, Matthieu Debailleul, Jean-Baptiste Courbot, Olivier Haeberlé

    Tomographic diffractive microscopy (TDM) is increasingly gaining attention, owing to its high-resolution, label-free imaging capability. Fast acquisitions necessitate limiting the number of holograms to be recorded. Reconstructions then rely on optimal Fourier space filling to retain image quality and resolution, that is, they rely on optimal scanning of the tomographic illuminations. In this work, we theoretically study reflection TDM, and then the 4Pi TDM, a combination of transmission and reflection systems. Image simulations are conducted to determine optimal angular sweeping. We found that three-dimensional uniform scanning fills Fourier space the best for both reflection and 4Pi configurations, providing a better refractive index estimation for the observed sample.