Takashi Yamane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takashi Yamane has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Masahiro Nishida
National Institute of Advanced Industrial Science and Technology
32 shared publications - Osamu Maruyama
National Institute of Advanced Industrial Science and Technology
32 shared publications - Ryo Kosaka
Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
19 shared publications Hiroshi Kawamura
Tokyo University of Science, Noda, Chiba
9 shared publicationsTatsuo Tsutsui
University of Tsukuba
9 shared publicationsToru Masuzawa
Graduate School of Engineering, Ibaraki University, Hitachi, Japan
7 shared publications
Latest Publications
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1H02
Analysis and experimental study for hemocompatibility of Axial-Flow Blood Pumps
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1H02
Analysis and experimental study for hemocompatibility of Axial-Flow Blood Pumps
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1H06
Effect of producing method on pump properties of a monopivot centrifugal blood pump
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1H06
Effect of producing method on pump properties of a monopivot centrifugal blood pump
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Conference on Frontiers in Bioengineering
- Vol. 2017.28, 1B32
A suitable hemolysis index for low flow blood pumps
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Conference on Frontiers in Bioengineering
- Vol. 2017.28, 1B32
A suitable hemolysis index for low flow blood pumps
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2017.29, 1B16
Inhibition and promotion mechanism of blood coagulation reaction under shear flow.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2017.29, 1B16
Inhibition and promotion mechanism of blood coagulation reaction under shear flow.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2016, J0240104
Research for Portable Axial Flow Ventricular Assist Device
Though several kinds of implantable ventricular assist devices (VADs) are available at present, their application is limited to transplantation candidates and other patients, who need partial circulatory assist, cannot use VADs in Japan. We are developing a small portable axial-flow pump whose blood contacting parts are made of polymer. Developed axial flow pump models, KAP5 and KAP6 have different discharge angles as 90 deg and 70 deg respectively. However, both KAP5 and KAP6 found an almost the same hemolysis level at 10000 rpm. Though the low-flow hemolysis level of KAP5 almost proportional to 2.8th power of rotational speed as usual, KAP6 attained lower level of hemolysis for 5000 rpm. We are investigating the suitable ranges of use for partial circulatory assist, while trying to reduce the hemolysis level by changing the fluid dynamic design. Antithrombogenic property of KAP6 was examined through a porcine experiment at a blood flow of 1-2 L/min. The result was that almost no thrombus was observed except for an upstream female pivot.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2016, J0240104
Research for Portable Axial Flow Ventricular Assist Device
Though several kinds of implantable ventricular assist devices (VADs) are available at present, their application is limited to transplantation candidates and other patients, who need partial circulatory assist, cannot use VADs in Japan. We are developing a small portable axial-flow pump whose blood contacting parts are made of polymer. Developed axial flow pump models, KAP5 and KAP6 have different discharge angles as 90 deg and 70 deg respectively. However, both KAP5 and KAP6 found an almost the same hemolysis level at 10000 rpm. Though the low-flow hemolysis level of KAP5 almost proportional to 2.8th power of rotational speed as usual, KAP6 attained lower level of hemolysis for 5000 rpm. We are investigating the suitable ranges of use for partial circulatory assist, while trying to reduce the hemolysis level by changing the fluid dynamic design. Antithrombogenic property of KAP6 was examined through a porcine experiment at a blood flow of 1-2 L/min. The result was that almost no thrombus was observed except for an upstream female pivot.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2016.28, _1A11-1_
1A11 Investigation on the Impeller Geometry of the Monopivot Centrifugal Blood Pump
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2016.28, _1A11-1_
1A11 Investigation on the Impeller Geometry of the Monopivot Centrifugal Blood Pump
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2015.27, 71-72
1B26 Change in relative permittivity by the thrombus volume and thrombus hematocrit
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2015.27, 71-72
1B26 Change in relative permittivity by the thrombus volume and thrombus hematocrit
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _W053006-1
W053006 The Electrical Impedance Measurement of Thrombus
When blood comes in contact with artificial systems it tends to clot more. Hence, blood clotting is the major issue in extracorporeal circulation. Due to this, the patients take regular anticoagulation medicine. The frequent use of such a medicine results to other consequences. Due to this, the optimum use of medicine is desirable. To address this issue, we have made an assessment of instrumentation systems based on electrical impedance measurement with the aim of developing a sensor to monitor the blood and detect the thrombogenic activities at the early stage. The experimental results obtained by monitoring the bovine blood are presented. It was understood that electrical resistivity can be a suitable parameter to detect embolus. And, change in capacitance was more specific to understand the thrombogenic process.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _W053006-1
W053006 The Electrical Impedance Measurement of Thrombus
When blood comes in contact with artificial systems it tends to clot more. Hence, blood clotting is the major issue in extracorporeal circulation. Due to this, the patients take regular anticoagulation medicine. The frequent use of such a medicine results to other consequences. Due to this, the optimum use of medicine is desirable. To address this issue, we have made an assessment of instrumentation systems based on electrical impedance measurement with the aim of developing a sensor to monitor the blood and detect the thrombogenic activities at the early stage. The experimental results obtained by monitoring the bovine blood are presented. It was understood that electrical resistivity can be a suitable parameter to detect embolus. And, change in capacitance was more specific to understand the thrombogenic process.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2013.25, 327-328
2C08 Visualization of erythrocyte sedimentation using process tomography
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2013.25, 327-328
2C08 Visualization of erythrocyte sedimentation using process tomography
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- Open Access
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2012, _S021011-1
S021011 Durability Test of Continuous-flow Ventricular Assist Devices under Pulsatile Flow
The durability test for a newly developing axial-flow ventricular assist device (VAD) with hydrodynamic bearings was conducted under pulsatile flow condition for six months to obtain a long-term reliability. A mock circulation was consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance and simple-layout flow paths that were made of polymer or titanium. The VAD was installed behind the diaphragm pump submerged in saline solution. A blood analog fluid was saline added with glycerin whose viscosity coincided with that of blood at the temperature of 37 ℃. The pulsatile flow condition was set within the flow rate range to realize positive flow rate and positive head at the impeller rotational speed obtaining the flow rate of 5 L/min and the pressure of 100 mmHg. The pump characteristics were monitored for flow rate, pressure head, impeller rotational speed, and so on. The mock circulation characteristics were maintained for fluid temperature, fluid density and pulse rate of the diaphragm pump, and so on. The mock circulation realized the pulsatile flow rate to achieve 0±1 L/min at the systolic phase, 9.5±1 L/min at the diastolic phase and 5±1 L/min in average at the pulse rate of 72 bpm. The durability tests were conducted for eight axial-flow VADs. For six months, the experimental conditions have been maintained that were the average flow rate of 4.4 (± 0.2) ± 0.05 (± 0.04) L/min, the diastic flow rate of 0.1 (± 0.1) ± 0.1 (± 0.1) L/min, the systolic flow rate of 10.9 (± 0.2) ± 0.1 (± 0.03) L/min, the average head of 80 (± 3) ± 2 (± 2) mmHg, the pulse rate of 72.1 (± 0.3) ± 0.2 (± 0.1) bpm, the fluid temparature of 37.2 (± 0.2) ± 0.2(± 0.1)℃, the fluid viscosity of 3.2(±0.1)±0.3(±0.1) cP, in which the value in the bracket means individual device differences. The metal components were hardly detected in the working fluids. The long-term durability of the developing axial-flow VAD for six months was confirmed.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2012, _S021011-1
Open AccessS021011 Durability Test of Continuous-flow Ventricular Assist Devices under Pulsatile Flow
The durability test for a newly developing axial-flow ventricular assist device (VAD) with hydrodynamic bearings was conducted under pulsatile flow condition for six months to obtain a long-term reliability. A mock circulation was consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance and simple-layout flow paths that were made of polymer or titanium. The VAD was installed behind the diaphragm pump submerged in saline solution. A blood analog fluid was saline added with glycerin whose viscosity coincided with that of blood at the temperature of 37 ℃. The pulsatile flow condition was set within the flow rate range to realize positive flow rate and positive head at the impeller rotational speed obtaining the flow rate of 5 L/min and the pressure of 100 mmHg. The pump characteristics were monitored for flow rate, pressure head, impeller rotational speed, and so on. The mock circulation characteristics were maintained for fluid temperature, fluid density and pulse rate of the diaphragm pump, and so on. The mock circulation realized the pulsatile flow rate to achieve 0±1 L/min at the systolic phase, 9.5±1 L/min at the diastolic phase and 5±1 L/min in average at the pulse rate of 72 bpm. The durability tests were conducted for eight axial-flow VADs. For six months, the experimental conditions have been maintained that were the average flow rate of 4.4 (± 0.2) ± 0.05 (± 0.04) L/min, the diastic flow rate of 0.1 (± 0.1) ± 0.1 (± 0.1) L/min, the systolic flow rate of 10.9 (± 0.2) ± 0.1 (± 0.03) L/min, the average head of 80 (± 3) ± 2 (± 2) mmHg, the pulse rate of 72.1 (± 0.3) ± 0.2 (± 0.1) bpm, the fluid temparature of 37.2 (± 0.2) ± 0.2(± 0.1)℃, the fluid viscosity of 3.2(±0.1)±0.3(±0.1) cP, in which the value in the bracket means individual device differences. The metal components were hardly detected in the working fluids. The long-term durability of the developing axial-flow VAD for six months was confirmed.