HRHenrique Faria Ramos

Henrique Faria Ramos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Henrique Faria Ramos has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Luiz Ubirajara Sennes

    Department of Otolaryngology of the University of São Paulo School of Medicine, São Paulo, Brazil

    3 shared publications
  • Bernardo Faria Ramos

    University of Sao Paulo Medical School

    2 shared publications
  • Carlos Diogenes Pinheiro-Neto

    Department of Otorhinolaryngology, Mayo Clinic, Rochester, MN

    1 shared publication
  • Carlos Diógenes Pinheiro Neto

    University of São Paulo, Brazil; Hospital Brigadeiro, Brazil

    1 shared publication
  • Carlos Diógenes Pinheiro-Neto

    Carlos Diógenes Pinheiro-Neto Universidade de São Paulo, Faculdade de Medicina , São Paulo, BrazilUniversidade de São PauloBrazilSão Paulo, BrazilUniversidade de São Paulo, Faculdade de Medicina , São Paulo, Brazil University of Pittsburgh, Department of Otolaryngology United StatesUniversity of PittsburghUnited States, United StatesUniversity of Pittsburgh, Department of Otolaryngology United States

    1 shared publication
  • Edigar Resende de Almeida

    Department of Otolaryngology, University of São Paulo School of Medicine, São Paulo, Brazil

    1 shared publication

Latest Publications

  • Pneumatization of the Sphenoidal Sinus May Affect Endonasal Cranial Base Reconstruction

    by Henrique Faria Ramos, Carlos Diogenes Pinheiro-Neto, Lucas Loss Possatti

    Objective: The aim of this study is to verify if the length of the nasoseptal flap is sufficient to cover the tuberculum sellae and planum sphenoidale of sphenoidal sinuses with varied degrees of pneumatization Methods: Retrospective study of paranasal sinus computed tomography comparing the potential length of the nasoseptal flap and the length of the nasoseptal flap required for reconstruction of transtuberculum and transplanum approaches in conchal, presellar, sellar, incomplete postsellar, and complete postsellar sphenoidal sinuses Results: The length of the nasoseptal flap required for reconstruction of transtuberculum and transplanum approaches was directly related to the degree of pneumatization of the sphenoidal sinus. The nasoseptal flap length was adequate to cover the cranial base after transtuberculum approaches of all cases from the conchal, presellar, and sellar groups and the majority of cases from postsellar pneumatization. For transplanum approaches, the nasosseptal flap was sufficient to reconstruct defects in most cases from conchal, pre-sellar, and sellar type sinuses and in 54,9% and 19,2% in incomplete and complete postsellar, respectively. Conclusions: In well pneumatized sphenoidal sinus, the nasoseptal flap may not be sufficient to cover the cranial base after transtuberculum and transplanum approaches.


  • Open Access

    Acquired stenosis of external auditory canal secondary to paraneoplastic manifestation of renal cancer

    by Loraine Entringer Falqueto, Marcos Lyra Kaddoum, Marcio Maia Lamy de Miranda, Henrique Faria Ramos


  • Open Access

    Juvenile Nasopharyngeal Angiofibroma with intradural extension

    by Henrique Faria Ramos, Marystella Tomoe Takahashi, Bernardo Faria Ramos, Marcos de Queiroz Teles Gomes, Luiz Ubirajara Sennes


  • Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

    by Henrique Faria Ramos, Signe Schuster Grasel, Roberto Miquelino de Oliveira Beck, Marystella Tomoe Takahashi-Ramos, Bernardo Faria Ramos, Edigar Resende de Almeida, Ricardo Ferreira Bento, Rubens de Brito Neto

    Conclusion: The correlations between behavioral and auditory steady-state response (ASSR) thresholds were significant at 500, 1000, 2000, and 4000 Hz. ASSR presented high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates when compared with warble-tone audiometry. Objectives: To assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in dichotic single-frequency ASSR with behavioral thresholds at 500, 1000, 2000, and 4000 Hz. Methods: This was a comparative study between ASSR and warble-tone audiometry thresholds in 40 cochlear implant candidates (80 ears) before cochlear implantation with bilateral severe-to-profound sensorineural hearing loss. Results: Thresholds were obtained in 62.5% of all frequencies evaluated in warble-tone audiometry and in 63.1% in the ASSR. ASSR sensitivity was 96% and specificity was 91.6%. Mean differences between behavioral and ASSR thresholds did not reach significance at any frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1000, and 2000 Hz and moderate in 4000 Hz, with correlation coefficients varying from 0.65 to 0.81. On 90% of occasions, ASSR thresholds were acquired within 10 dB of behavioral thresholds.


  • Open Access

    Endoscopic anatomy of the approaches to the sellar area and planum sphenoidale.

    by Henrique Faria Ramos, Tatiana Alves Monteiro, Carlos Diógenes Pinheiro Neto, Pedro Paulo Mariani, Felipe Sartor Guimarães Fortes, Luiz Ubirajara Sennes

    The productive work between otolaryngologists and neurosurgeons has resulted in the emergence of endoscopic endonasal skull base surgery. The goal of the present study is to describe the endoscopic anatomy of the endonasal approach to the sellar region and planum sphenoidale, highlighting the key points of the surgical approach and the neurovascular landmarks.


  • Open Access

    Ligadura endoscópica da artéria etmoidal anterior: estudo de dissecção em cadáveres

    by Carlos Diógenes Pinheiro-Neto, Henrique Faria Ramos, Richard Louis Voegels, Luiz Ubirajara Sennes

    Ligadura da artéria etmoidal anterior (AEA) pode ser necessária em casos de epistaxe grave refratária ao tratamento tradicional. O uso da ligadura endoscópica endonasal da AEA ainda é bastante limitado. Existem poucos estudos na literatura sobre a técnica de abordagem endoscópica desta artéria. OBJETIVOS: Demonstrar a aplicabilidade técnica da ligadura periorbitária da AEA por via endoscópica transetmoidal. MATERIAL E MÉTODOS: Estudo prospectivo. 50 fossas nasais de cadáveres foram dissecadas. Após a realização de uma etmoidectomia anterior e remoção parcial da lâmina papirácea, a periórbita foi cuidadosamente dissecada até a identificação da AEA. Após sua identificação, a artéria foi exposta e ligada dentro da órbita. RESULTADOS: Todas as dificuldades inerentes ao procedimento, as complicações associadas, a curva de aprendizado e variações anatômicas foram coletados. CONCLUSÕES: A abordagem endoscópica da AEA na órbita de cadáveres mostrou-se factível. A identificação da artéria é fácil e a técnica evita incisões externas. Este acesso parece ser uma excelente alternativa para a abordagem da AEA. Estudos clínicos futuros são necessários para comprovar os benefícios desta técnica.