Björn Poppe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Björn Poppe has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Dietrich Harder
Prof. em., Medical Physics and Biophysics, Georg-August University Göttingen, Germany
6 shared publications Armand Djouguela
Clinic of Radiotherapy and Oncology, Pius Hospital Oldenburg, Oldenburg, Germany
4 shared publicationsRalf Kollhoff
Clinic of Radiotherapy and Oncology, Pius Hospital Oldenburg, Oldenburg, Germany
4 shared publicationsAntje Rubach
3 shared publicationsArne Blechschmidt
3 shared publications- Frank-André Siebert
Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany
2 shared publications
Latest Publications
- Open Access
- 20 July 2026
- Published by MDPI AG in Tomography
- Vol. 12 (7) , 107
Ocular Radiation Exposure and Shielding Practices During Complex Fluoroscopic Guided Interventions: An Exploratory Multicenter Observational Study
Background/Objectives: Lead acrylic shields (LASs) enhance radiation protection, with variation of their usage among different specialties. This prospective multicentric observational study aimed to explore patterns of ocular radiation exposure and LAS usage among interventionalists from different disciplines and to assess behavioral dose changes in a longitudinally monitored subgroup. Methods: From July 2019 to July 2020, ocular doses (protected and unprotected) were measured in 15 interventionalists from four specialties (radiology, neuroradiology, cardiology and vascular surgery) across 2286 procedures using thermoluminescent dosimeters. Procedure type, operator position, total body dose, fluoroscopy time, dose area product, LAS usage and dose exceedances were documented. Ocular doses of five interventionalists, who participated in our previous study, allowed a longitudinal comparison of radiation doses and protective behavior. Results: Cumulative annual unprotected ocular doses ranged from 0 to 59 mSv, with five participants exceeding the annual limit of 20 mSv, whereas protected doses (0 to 18 mSv) remained within the limits. Procedural LAS usage was seen in 89% of radiologists and 82% of vascular surgeons. Participants with 100% LAS usage recorded minimal measurable ocular doses, whereas lower LAS compliance resulted in higher ocular doses. Longitudinal subgroup data analyses showed a decrease in ocular dose per procedure in all five participants, suggesting a potential learning effect, without statistical significance. Conclusions: Unprotected ocular doses exceeded the annual occupational eye lens dose limit in several participants, whereas protected doses remained within recommended limits in all participants. No specialty demonstrated universally lower ocular doses, while consistent LAS use proved highly effective in reducing the dose in all groups. Longitudinal findings suggest that structured dose monitoring and repeated training may support behavioral improvements in radiation protection over time.
- 20 July 2026
- Published by MDPI AG in Tomography
- Vol. 12 (7) , 107
Open AccessOcular Radiation Exposure and Shielding Practices During Complex Fluoroscopic Guided Interventions: An Exploratory Multicenter Observational Study
Background/Objectives: Lead acrylic shields (LASs) enhance radiation protection, with variation of their usage among different specialties. This prospective multicentric observational study aimed to explore patterns of ocular radiation exposure and LAS usage among interventionalists from different disciplines and to assess behavioral dose changes in a longitudinally monitored subgroup. Methods: From July 2019 to July 2020, ocular doses (protected and unprotected) were measured in 15 interventionalists from four specialties (radiology, neuroradiology, cardiology and vascular surgery) across 2286 procedures using thermoluminescent dosimeters. Procedure type, operator position, total body dose, fluoroscopy time, dose area product, LAS usage and dose exceedances were documented. Ocular doses of five interventionalists, who participated in our previous study, allowed a longitudinal comparison of radiation doses and protective behavior. Results: Cumulative annual unprotected ocular doses ranged from 0 to 59 mSv, with five participants exceeding the annual limit of 20 mSv, whereas protected doses (0 to 18 mSv) remained within the limits. Procedural LAS usage was seen in 89% of radiologists and 82% of vascular surgeons. Participants with 100% LAS usage recorded minimal measurable ocular doses, whereas lower LAS compliance resulted in higher ocular doses. Longitudinal subgroup data analyses showed a decrease in ocular dose per procedure in all five participants, suggesting a potential learning effect, without statistical significance. Conclusions: Unprotected ocular doses exceeded the annual occupational eye lens dose limit in several participants, whereas protected doses remained within recommended limits in all participants. No specialty demonstrated universally lower ocular doses, while consistent LAS use proved highly effective in reducing the dose in all groups. Longitudinal findings suggest that structured dose monitoring and repeated training may support behavioral improvements in radiation protection over time.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 147-149
A new method for effective dose calculation based on the ambient dose height distribution
The realistic determination of effective dose of the staff in diagnostic radiology has been a challenge both for personal dosimetry and ambient dose measurement. A model for dosimetry of occupational exposure is presented that allows direct determination of effective dose from measured or even manufacturer given ambient dose distribution in front of the personnel. This model considers a wide range of radiation energies, different radiation protection situations, and gender effects.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 147-149
Open AccessA new method for effective dose calculation based on the ambient dose height distribution
The realistic determination of effective dose of the staff in diagnostic radiology has been a challenge both for personal dosimetry and ambient dose measurement. A model for dosimetry of occupational exposure is presented that allows direct determination of effective dose from measured or even manufacturer given ambient dose distribution in front of the personnel. This model considers a wide range of radiation energies, different radiation protection situations, and gender effects.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 277-280
Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 277-280
Open AccessUsability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA.
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s136-s143
Poster session 9: Dosimetry, radiation protection and radiation biology II
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s136-s143
Poster session 9: Dosimetry, radiation protection and radiation biology II
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s517-s520
Session 57. Dosimetry, radiation protection and radiation biology IV
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s517-s520
Session 57. Dosimetry, radiation protection and radiation biology IV
- Open Access
- 1 March 2014
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 24 (1) , 27-37
Supplementary values of the dosimetric parameters kNR and Em for various types of detectors in 6 and 15 MV photon fields
- 1 March 2014
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 24 (1) , 27-37
Open AccessSupplementary values of the dosimetric parameters kNR and Em for various types of detectors in 6 and 15 MV photon fields
- 31 July 2013
- Published by Wiley in Medical Physics
- Vol. 40 (8) , 082106
Performance parameters of a liquid filled ionization chamber array
In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated. Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles. The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72±0.25) mm at 6 MV and (0.74±0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm(-1), respectively. For the inner 5×5 cm2 region and the outer 11×11 cm2 region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm(-1), respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm∕3% criterion with a TPS calculation as reference. This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.
- 31 July 2013
- Published by Wiley in Medical Physics
- Vol. 40 (8) , 082106
Performance parameters of a liquid filled ionization chamber array
In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated. Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles. The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72±0.25) mm at 6 MV and (0.74±0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm(-1), respectively. For the inner 5×5 cm2 region and the outer 11×11 cm2 region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm(-1), respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm∕3% criterion with a TPS calculation as reference. This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.
- Open Access
- 1 September 2012
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 22 (3) , 181-196
Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy
- 1 September 2012
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 22 (3) , 181-196
Open AccessNon-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy
- 1 January 2007
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 183 (1) , 43-48
The Effect of a Carbon-Fiber Couch on the Depth-Dose Curves and Transmission Properties for Megavoltage Photon Beams
Purpose: To investigate the attenuation of a carbon-fiber tabletop and a combiboard, alongside with the depth-dose profile in a solid-water phantom. Material and Methods: Depth-dose measurements were performed with a Roos chamber for 6- and 10-MV beams for a typical field size (15 cm × 15 cm, SSD [source-surface distance] 100 cm). A rigid-stem ionization chamber was used to measure transmission factors. Results: Transmission factors varied between 93.6% and 97.3% for the 6-MV beam, and 95.1% and 97.7% for the 10-MV photon beam. The lowest transmission factors were observed for the oblique gantry angle of 150° with the table-combiboard combination. The surface dose normalized to a depth of 5 cm increased from 59.4% (without table, 0° gantry), to 108.6% (tabletop present, 180° gantry), and further to 120% (table-combiboard combination) for 6-MV photon beam. For 10 MV, the increase was from 39.6% (without table), to 88.9% (with table), and to 105.6% (table-combiboard combination). For the 150° angle (tablecombiboard combination), the dose increased from 59.4% to 120% (6 MV) and from 39% to 108.1% (10 MV). Conclusion: Transmission factors for tabletops and accessories directly interfering with the treatment beam should be measured and implemented into the treatment-planning process. The increased surface dose to the skin should be considered.
- 1 January 2007
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 183 (1) , 43-48
The Effect of a Carbon-Fiber Couch on the Depth-Dose Curves and Transmission Properties for Megavoltage Photon Beams
Purpose: To investigate the attenuation of a carbon-fiber tabletop and a combiboard, alongside with the depth-dose profile in a solid-water phantom. Material and Methods: Depth-dose measurements were performed with a Roos chamber for 6- and 10-MV beams for a typical field size (15 cm × 15 cm, SSD [source-surface distance] 100 cm). A rigid-stem ionization chamber was used to measure transmission factors. Results: Transmission factors varied between 93.6% and 97.3% for the 6-MV beam, and 95.1% and 97.7% for the 10-MV photon beam. The lowest transmission factors were observed for the oblique gantry angle of 150° with the table-combiboard combination. The surface dose normalized to a depth of 5 cm increased from 59.4% (without table, 0° gantry), to 108.6% (tabletop present, 180° gantry), and further to 120% (table-combiboard combination) for 6-MV photon beam. For 10 MV, the increase was from 39.6% (without table), to 88.9% (with table), and to 105.6% (table-combiboard combination). For the 150° angle (tablecombiboard combination), the dose increased from 59.4% to 120% (6 MV) and from 39% to 108.1% (10 MV). Conclusion: Transmission factors for tabletops and accessories directly interfering with the treatment beam should be measured and implemented into the treatment-planning process. The increased surface dose to the skin should be considered.
- 12 August 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 123 (1) , 131-134
Dose-area product measurements in panoramic dental radiology
In this study, dose-area product (DAP) measurements in panoramic dental radiology have been performed in Germany. The results obtained in this study were proposed as diagnostic reference levels (DRLs). A representative number of dental panoramic units, both with digital and conventional image receptors, have been chosen. Common statistical parameters such as mean, standard deviation and 3rd quartile have been calculated. For four different standard programmes, ‘large adult’, ‘adult male’, ‘adult female’ and ‘child’, the proposed DRLs are 101, 87, 84 and 75 mGy cm2, respectively. No clear tendency to a generalised dose reduction from the transition to digital techniques has been observed. Effective doses have been calculated from E/DAP conversion factors published in literature. Even though these values differ by a factor of ∼3, upper limits of 15.8–21.2 μSv for the four different exposure settings were derived from the data.
- 12 August 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 123 (1) , 131-134
Dose-area product measurements in panoramic dental radiology
In this study, dose-area product (DAP) measurements in panoramic dental radiology have been performed in Germany. The results obtained in this study were proposed as diagnostic reference levels (DRLs). A representative number of dental panoramic units, both with digital and conventional image receptors, have been chosen. Common statistical parameters such as mean, standard deviation and 3rd quartile have been calculated. For four different standard programmes, ‘large adult’, ‘adult male’, ‘adult female’ and ‘child’, the proposed DRLs are 101, 87, 84 and 75 mGy cm2, respectively. No clear tendency to a generalised dose reduction from the transition to digital techniques has been observed. Effective doses have been calculated from E/DAP conversion factors published in literature. Even though these values differ by a factor of ∼3, upper limits of 15.8–21.2 μSv for the four different exposure settings were derived from the data.