Latest Publications
- 1 July 2011
- Published by Wolters Kluwer Health in Health Physics
- Vol. 101 (1) , 79-83
THE DEVIATION OF LIVER DOSE IN REAL PATIENTS FOR THORACIC COMPUTED TOMOGRAPHY SCANS: A NEW APPROACH TO INDIVIDUAL DOSIMETRY WITH METHODS OF RADIOTHERAPY TREATMENT PLANNING
The increasing use of computed tomography (CT) in diagnostic imaging is associated with a relevant increase in patient dose and requires CT dose optimization. Anthropomorphic phantoms and mathematical patient models have been developed to improve the dosimetry in diagnostic imaging. Nevertheless, the doses calculated in these models and the ones individual patients can receive may differ considerably. In particular, the assessment of organ doses is problematic when organs and tissues receive only a partial exposure. A typical example for this situation is the exposure of the liver within a thoracic CT. To evaluate the impact of the field boundary and the liver volume on the individual organ dose, 50 CT scans from 25 male and 25 female patients between the ages of 27 to 87 were analyzed in this study with the volumetric tools of a treatment planning system for radiotherapy. The relative volume of the liver within a thoracic CT was assessed and compared to results from dosimetry methods using standardized patient models. The differences between an individual dose and the results from standardized patients are considerable. The fraction of the liver volume within a thoracic CT with a standard lower boundary extends from 48-92%, resulting in a possible dose difference of up to a factor of 1.7. Results from mathematical phantoms can underestimate the liver dose by more than a factor of 2.6. From the determined data, correction factors for the dosimetry of the liver using standard programs can be derived.
- 1 July 2011
- Published by Wolters Kluwer Health in Health Physics
- Vol. 101 (1) , 79-83
THE DEVIATION OF LIVER DOSE IN REAL PATIENTS FOR THORACIC COMPUTED TOMOGRAPHY SCANS: A NEW APPROACH TO INDIVIDUAL DOSIMETRY WITH METHODS OF RADIOTHERAPY TREATMENT PLANNING
The increasing use of computed tomography (CT) in diagnostic imaging is associated with a relevant increase in patient dose and requires CT dose optimization. Anthropomorphic phantoms and mathematical patient models have been developed to improve the dosimetry in diagnostic imaging. Nevertheless, the doses calculated in these models and the ones individual patients can receive may differ considerably. In particular, the assessment of organ doses is problematic when organs and tissues receive only a partial exposure. A typical example for this situation is the exposure of the liver within a thoracic CT. To evaluate the impact of the field boundary and the liver volume on the individual organ dose, 50 CT scans from 25 male and 25 female patients between the ages of 27 to 87 were analyzed in this study with the volumetric tools of a treatment planning system for radiotherapy. The relative volume of the liver within a thoracic CT was assessed and compared to results from dosimetry methods using standardized patient models. The differences between an individual dose and the results from standardized patients are considerable. The fraction of the liver volume within a thoracic CT with a standard lower boundary extends from 48-92%, resulting in a possible dose difference of up to a factor of 1.7. Results from mathematical phantoms can underestimate the liver dose by more than a factor of 2.6. From the determined data, correction factors for the dosimetry of the liver using standard programs can be derived.
- 29 April 2011
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 183 (S 01) , MTRA4_2
Strahlenschutz für den Patienten
Möglichkeiten zur Dosisreduktion beim Patienten bestehen zum einen im Rahmen einer dosissparenden Untersuchungstechnik, zum anderen im Nutzen gerätetechnischer Potenziale. Die Effektivität unterschiedlicher Maßnahmen lässt sich durch die Bestimmung der Patientendosis leicht belegen. Deshalb wird in diesem Zusammenhang speziell auf das Dosisflächenprodukt (Direktradiographie) und das Dosislängenprodukt (CT) eingegangen. Zur Umrechnung dieser Größen in die effektive Dosis werden Faustformeln angegeben, um den Nutzen der Maßnahmen unmittelbar abgeschätzen zu können. Auf der anderen Seite kann die Dosis bestimmter Organe (z.B. Gonaden, Augenlinse, Schilddrüse, Mammae) „gezielt“ durch Verwendung von Strahlenschutzmaterial verringert werden, wobei unterschiedliche Maßnahmen Organe innerhalb oder außerhalb des Untersuchungsbereichs betreffen können. Auf rechtliche Voraussetzungen, den konkreten Einsatz der Abschirmungen und die jeweilige Wirksamkeit der Maßnahmen wird im Einzelnen eingegangen. Die Eigenschaften verschiedener Strahlenschutzmaterialien werden erläutert und die Frage diskutiert, inwieweit eine mögliche Rückstreuung aus dem Abschirmmaterial für die Patientendosis relevant ist. Lernziele: Optimierung der Strahlenexposition des Patienten, Anwendung von Patientenschutzmitteln, technische und untersucherabhängige Strahlenschutzmaßnahmen Korrespondierender Autor: von Boetticher H Klinikum Links der Weser, Institut für Radiologie und Seminar für Strahlenschutz, Senator-Weßling-Str. 1, 28277 Bremen E-Mail: heiner.boetticher@klinikum-bremen-ldw.de
- 29 April 2011
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 183 (S 01) , MTRA4_2
Strahlenschutz für den Patienten
Möglichkeiten zur Dosisreduktion beim Patienten bestehen zum einen im Rahmen einer dosissparenden Untersuchungstechnik, zum anderen im Nutzen gerätetechnischer Potenziale. Die Effektivität unterschiedlicher Maßnahmen lässt sich durch die Bestimmung der Patientendosis leicht belegen. Deshalb wird in diesem Zusammenhang speziell auf das Dosisflächenprodukt (Direktradiographie) und das Dosislängenprodukt (CT) eingegangen. Zur Umrechnung dieser Größen in die effektive Dosis werden Faustformeln angegeben, um den Nutzen der Maßnahmen unmittelbar abgeschätzen zu können. Auf der anderen Seite kann die Dosis bestimmter Organe (z.B. Gonaden, Augenlinse, Schilddrüse, Mammae) „gezielt“ durch Verwendung von Strahlenschutzmaterial verringert werden, wobei unterschiedliche Maßnahmen Organe innerhalb oder außerhalb des Untersuchungsbereichs betreffen können. Auf rechtliche Voraussetzungen, den konkreten Einsatz der Abschirmungen und die jeweilige Wirksamkeit der Maßnahmen wird im Einzelnen eingegangen. Die Eigenschaften verschiedener Strahlenschutzmaterialien werden erläutert und die Frage diskutiert, inwieweit eine mögliche Rückstreuung aus dem Abschirmmaterial für die Patientendosis relevant ist. Lernziele: Optimierung der Strahlenexposition des Patienten, Anwendung von Patientenschutzmitteln, technische und untersucherabhängige Strahlenschutzmaßnahmen Korrespondierender Autor: von Boetticher H Klinikum Links der Weser, Institut für Radiologie und Seminar für Strahlenschutz, Senator-Weßling-Str. 1, 28277 Bremen E-Mail: heiner.boetticher@klinikum-bremen-ldw.de
- 1 December 2009
- Published by Wolters Kluwer Health in Health Physics
- Vol. 97 (6) , 622-627
Cardiac Catheterization: Impact of Face and Neck Shielding on New Estimates of Effective Dose
Optimization of radiation protection devices for the operator is achieved by minimizing the effective dose (E) on the basis of the recommendations of Publications 60 and 103 of the International Commission on Radiological Protection (ICRP). Radiation exposure dosimetry was performed with thermoluminescence dosimeters using one Alderson phantom in the patient position and a second one in the typical position of the operator. Various types of protective clothing as well as fixed leaded shieldings (table mounted shielding and overhead suspended shields) were considered calculating E. Shielding factors for protective equipment can readily be misinterpreted referring to the reduction of the effective dose because fixed protective barriers as well as radiation protection clothing are shielding only parts of the body. With the ICRP 103 approach relative to the exposure without lead protection, a lead apron of 0.35 or 0.5 mm thickness reduces E to 14.4 or 12.3%, respectively; by using an additional thyroid collar, these values are reduced to 9.7 or 7.5%. A thyroid collar reduces the effective dose by more than an increase of the lead equivalency of the existing apron. Wearing an apron of 0.5 mm lead-equivalent with a thyroid collar and using an additional side shield, E decreases to 6.8%. Using both a fixed side and face shield decreases E to 2.0%. For protective garments including thyroid protection, the values of the effective dose in cardiac catheterization are 47-106% higher with ICRP 103 than with ICRP 60 recommendations. This is essentially caused by the introduction of new factors for organs in the head and neck region in ICRP 103.
- 1 December 2009
- Published by Wolters Kluwer Health in Health Physics
- Vol. 97 (6) , 622-627
Cardiac Catheterization: Impact of Face and Neck Shielding on New Estimates of Effective Dose
Optimization of radiation protection devices for the operator is achieved by minimizing the effective dose (E) on the basis of the recommendations of Publications 60 and 103 of the International Commission on Radiological Protection (ICRP). Radiation exposure dosimetry was performed with thermoluminescence dosimeters using one Alderson phantom in the patient position and a second one in the typical position of the operator. Various types of protective clothing as well as fixed leaded shieldings (table mounted shielding and overhead suspended shields) were considered calculating E. Shielding factors for protective equipment can readily be misinterpreted referring to the reduction of the effective dose because fixed protective barriers as well as radiation protection clothing are shielding only parts of the body. With the ICRP 103 approach relative to the exposure without lead protection, a lead apron of 0.35 or 0.5 mm thickness reduces E to 14.4 or 12.3%, respectively; by using an additional thyroid collar, these values are reduced to 9.7 or 7.5%. A thyroid collar reduces the effective dose by more than an increase of the lead equivalency of the existing apron. Wearing an apron of 0.5 mm lead-equivalent with a thyroid collar and using an additional side shield, E decreases to 6.8%. Using both a fixed side and face shield decreases E to 2.0%. For protective garments including thyroid protection, the values of the effective dose in cardiac catheterization are 47-106% higher with ICRP 103 than with ICRP 60 recommendations. This is essentially caused by the introduction of new factors for organs in the head and neck region in ICRP 103.
- 1 September 2008
- Published by Wolters Kluwer Health in Health Physics
- Vol. 95 (3) , 337-340
EFFECTIVE DOSE ESTIMATION IN DIAGNOSTIC RADIOLOGY WITH TWO DOSIMETERS: IMPACT OF THE 2007 RECOMMENDATIONS OF THE ICRP
In many standard situations in radiation protection the effective dose is underestimated if it is based on the depth personal dose equivalent Hp(10) measured with a single dosimeter in the anterior thoracic region (chest) underneath the protective apron (Hp,c,u). The estimate can be significantly improved by inclusion of a second dosimeter worn on the front area of the neck over of the protective garment (Hp,n,o) representing organs and areas that are usually not completely covered by the protective garment. The recent recommendations of the International Commission on Radiological Protection (ICRP) emphasize the contribution of the head and neck region to the effective dose. This accentuates the need for a valid representation of this body region in the effective dose algorithm. In this paper we derived coefficients for the two-dosimeter situation using phantom measurements for selected radiological procedures with different geometries between patient and investigator. According to ICRP 60, the algorithm with {without} thyroid protection is E = 0.64{0.64}Hp,c,u + 0.016{0.073}Hp,n,o. According to ICRP 103, the algorithm becomes E = 0.60{0.60}Hp,c,u + 0.047{0.094}Hp,n,o. The ICRP 103 model reveals that the underestimation of the effective dose based on Hp(10) using a single dosimeter worn under the protective garment is even higher than previously assumed based on ICRP 60. Future personal dosimetry should be qualified by a two-dosimeter concept. The head and neck region which is not covered by a conventional protective garment needs to be protected by mounted shielding or other constructive measures.
- 1 September 2008
- Published by Wolters Kluwer Health in Health Physics
- Vol. 95 (3) , 337-340
EFFECTIVE DOSE ESTIMATION IN DIAGNOSTIC RADIOLOGY WITH TWO DOSIMETERS: IMPACT OF THE 2007 RECOMMENDATIONS OF THE ICRP
In many standard situations in radiation protection the effective dose is underestimated if it is based on the depth personal dose equivalent Hp(10) measured with a single dosimeter in the anterior thoracic region (chest) underneath the protective apron (Hp,c,u). The estimate can be significantly improved by inclusion of a second dosimeter worn on the front area of the neck over of the protective garment (Hp,n,o) representing organs and areas that are usually not completely covered by the protective garment. The recent recommendations of the International Commission on Radiological Protection (ICRP) emphasize the contribution of the head and neck region to the effective dose. This accentuates the need for a valid representation of this body region in the effective dose algorithm. In this paper we derived coefficients for the two-dosimeter situation using phantom measurements for selected radiological procedures with different geometries between patient and investigator. According to ICRP 60, the algorithm with {without} thyroid protection is E = 0.64{0.64}Hp,c,u + 0.016{0.073}Hp,n,o. According to ICRP 103, the algorithm becomes E = 0.60{0.60}Hp,c,u + 0.047{0.094}Hp,n,o. The ICRP 103 model reveals that the underestimation of the effective dose based on Hp(10) using a single dosimeter worn under the protective garment is even higher than previously assumed based on ICRP 60. Future personal dosimetry should be qualified by a two-dosimeter concept. The head and neck region which is not covered by a conventional protective garment needs to be protected by mounted shielding or other constructive measures.
- 25 April 2008
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 180 (5) , 391-395
2007 Recommendations of the ICRP Change Basis for Estimation of the Effective Dose: What is the Impact on Radiation Dose Assessment of Patient and Personnel?
Ziel: Das in den Strahlenschutzbestimmungen festgelegte Berechnungsverfahren für die effektive Dosis beruht international auf den Angaben der Publikation 60 (1990) der Internationalen Strahlenschutzkommission ICRP. Durch die Neufestsetzung der Organ-Wichtungsfaktoren in der Publikation 103 (2007) der ICRP wird dieses Verfahren modifiziert. Die vorliegende Übersicht gibt an, unter welchen Expositionsbedingungen relevante Dosisdifferenzen gegenüber dem bisherigen Modell auftreten können und mit welcher Größenordnung von Differenzen gerechnet werden muss. Material und Methoden: Es wird auf Grundlage von gemessenen Organdosen die effektive Dosis gemäß den Publikationen 60 und 103 der ICRP ermittelt und die Ergebnisse miteinander verglichen. Für die Patientendosimetrie werden Dosisbestimmungen mit einem anthropomorphen Phantom bei Thorax- und Kardio-CT-Untersuchungen durchgeführt, für die Dosimetrie des Personals werden Messungen aus der Angiografie mit zwei anthropomorphen Phantomen zugrunde gelegt. Ergebnisse: Der im Modell der ICRP 103 von 0,05 auf 0,12 angehobene Wichtungsfaktor für die Brust führt zu einer deutlichen Erhöhung der effektiven Dosis beim Thorax-CT (21 %) und Kardio-CT (31 %). Bei Bestimmung einer geschlechtsspezifischen effektiven Dosis auf Grundlage der ICRP 60 erhält die Frau beim Kardio-CT eine um den Faktor 1,7 höhere Dosis als der Mann, auf Grundlage der ICRP 103 beträgt die Erhöhung das 3,3-fache. Beim Personal führt bei der Angiografie die Neuberücksichtigung weiterer Organe im Kopf-Hals-Bereich gemäß der ICRP 103 zu einer deutlich erhöhten relativen effektiven Dosis um 24 - 50 % (ohne Schilddrüsenschutz) bzw. 38 - 142 % (mit Schilddrüsenschutz). Dabei unterschätzt die amtliche Personendosimetrie nach dem Modell der ICRP 103 die effektive Dosis um einen Faktor 1,6 - 2,4 (ohne Schilddrüsenschutz) bzw. 1,1 - 1,4 (mit Schilddrüsenschutz). Schlussfolgerung: Die Neufestlegung der Berechnungsgrundlagen führt zu einer höheren Dosis und einem deutlich erhöhten Einfluss des Geschlechtes bei Röntgenuntersuchungen, bei denen die Brust betroffen ist. Dies sollte bei der Indikationsstellung berücksichtigt werden. Für das Personal ergeben sich höhere effektive Dosen durch die Neubewertung der Relevanz von Organdosen im Kopf-Hals-Bereich. Dem Strahlenschutz dieser Körperregion kommt damit eine erhöhte Bedeutung zu. Purpose: In radiation protection regulations the algorithm for effective dose calculation is based on Publication 60 (1990) of the International Commission on Radiological Protection (ICRP). The modifications to the tissue weighting factors in Publication 103 (2007) of the ICRP will affect the present methodology of calculating the effective dose and will also have an impact on its assessment. This paper evaluates circumstances under which the application of the new model yields relevant dose differences compared to the prevailing model. Materials and Methods: Effective doses were calculated and compared from the measured organ doses according to ICRP 60 and ICRP 103, respectively. The measurements of patient doses were carried out with an anthropomorphic phantom for thoracic and coronary CT examinations. Exposure of radiological personnel was measured based on the geometry of angiographic examinations using two anthropomorphic phantoms. Results: The change of the weighting factor for the breast from 0.05 to 0.12 leads to a noticeable increase in the effective dose for thoracic (21 %) and coronary (31 %) CT examinations. Calculating sex-specific effective doses based on ICRP 60, the dose for coronary CT examination for women is 1.7 times higher than for men. Based on ICRP 103, the difference between female and male doses increases to a factor of 3.3. Due to the consideration of organs in the head and neck region as introduced in ICRP 103, for angiography the personnel is exposed to 24 - 50 % and 38 - 142 % higher doses with and without thyroid protection, respectively. Thereby, the official personal dosimetry will underestimate the effective dose according to ICRP 103 by a factor of 1.6 - 2.4 with thyroid protection and 1.1 - 1.4 without thyroid protection. Conclusion: The revision of the parameters for effective dose calculation leads to higher doses and greater sex-specific differences for radiological examinations involving exposure of the breast. This effect should be considered when justifying any radiological examination. For the personnel, the new model results in higher effective doses due to increased emphasis on the organs in the head and neck region. Hence to optimize radiation protection of personnel, the use of radiation-protective shielding for this region becomes more important.
- 25 April 2008
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 180 (5) , 391-395
2007 Recommendations of the ICRP Change Basis for Estimation of the Effective Dose: What is the Impact on Radiation Dose Assessment of Patient and Personnel?
Ziel: Das in den Strahlenschutzbestimmungen festgelegte Berechnungsverfahren für die effektive Dosis beruht international auf den Angaben der Publikation 60 (1990) der Internationalen Strahlenschutzkommission ICRP. Durch die Neufestsetzung der Organ-Wichtungsfaktoren in der Publikation 103 (2007) der ICRP wird dieses Verfahren modifiziert. Die vorliegende Übersicht gibt an, unter welchen Expositionsbedingungen relevante Dosisdifferenzen gegenüber dem bisherigen Modell auftreten können und mit welcher Größenordnung von Differenzen gerechnet werden muss. Material und Methoden: Es wird auf Grundlage von gemessenen Organdosen die effektive Dosis gemäß den Publikationen 60 und 103 der ICRP ermittelt und die Ergebnisse miteinander verglichen. Für die Patientendosimetrie werden Dosisbestimmungen mit einem anthropomorphen Phantom bei Thorax- und Kardio-CT-Untersuchungen durchgeführt, für die Dosimetrie des Personals werden Messungen aus der Angiografie mit zwei anthropomorphen Phantomen zugrunde gelegt. Ergebnisse: Der im Modell der ICRP 103 von 0,05 auf 0,12 angehobene Wichtungsfaktor für die Brust führt zu einer deutlichen Erhöhung der effektiven Dosis beim Thorax-CT (21 %) und Kardio-CT (31 %). Bei Bestimmung einer geschlechtsspezifischen effektiven Dosis auf Grundlage der ICRP 60 erhält die Frau beim Kardio-CT eine um den Faktor 1,7 höhere Dosis als der Mann, auf Grundlage der ICRP 103 beträgt die Erhöhung das 3,3-fache. Beim Personal führt bei der Angiografie die Neuberücksichtigung weiterer Organe im Kopf-Hals-Bereich gemäß der ICRP 103 zu einer deutlich erhöhten relativen effektiven Dosis um 24 - 50 % (ohne Schilddrüsenschutz) bzw. 38 - 142 % (mit Schilddrüsenschutz). Dabei unterschätzt die amtliche Personendosimetrie nach dem Modell der ICRP 103 die effektive Dosis um einen Faktor 1,6 - 2,4 (ohne Schilddrüsenschutz) bzw. 1,1 - 1,4 (mit Schilddrüsenschutz). Schlussfolgerung: Die Neufestlegung der Berechnungsgrundlagen führt zu einer höheren Dosis und einem deutlich erhöhten Einfluss des Geschlechtes bei Röntgenuntersuchungen, bei denen die Brust betroffen ist. Dies sollte bei der Indikationsstellung berücksichtigt werden. Für das Personal ergeben sich höhere effektive Dosen durch die Neubewertung der Relevanz von Organdosen im Kopf-Hals-Bereich. Dem Strahlenschutz dieser Körperregion kommt damit eine erhöhte Bedeutung zu. Purpose: In radiation protection regulations the algorithm for effective dose calculation is based on Publication 60 (1990) of the International Commission on Radiological Protection (ICRP). The modifications to the tissue weighting factors in Publication 103 (2007) of the ICRP will affect the present methodology of calculating the effective dose and will also have an impact on its assessment. This paper evaluates circumstances under which the application of the new model yields relevant dose differences compared to the prevailing model. Materials and Methods: Effective doses were calculated and compared from the measured organ doses according to ICRP 60 and ICRP 103, respectively. The measurements of patient doses were carried out with an anthropomorphic phantom for thoracic and coronary CT examinations. Exposure of radiological personnel was measured based on the geometry of angiographic examinations using two anthropomorphic phantoms. Results: The change of the weighting factor for the breast from 0.05 to 0.12 leads to a noticeable increase in the effective dose for thoracic (21 %) and coronary (31 %) CT examinations. Calculating sex-specific effective doses based on ICRP 60, the dose for coronary CT examination for women is 1.7 times higher than for men. Based on ICRP 103, the difference between female and male doses increases to a factor of 3.3. Due to the consideration of organs in the head and neck region as introduced in ICRP 103, for angiography the personnel is exposed to 24 - 50 % and 38 - 142 % higher doses with and without thyroid protection, respectively. Thereby, the official personal dosimetry will underestimate the effective dose according to ICRP 103 by a factor of 1.6 - 2.4 with thyroid protection and 1.1 - 1.4 without thyroid protection. Conclusion: The revision of the parameters for effective dose calculation leads to higher doses and greater sex-specific differences for radiological examinations involving exposure of the breast. This effect should be considered when justifying any radiological examination. For the personnel, the new model results in higher effective doses due to increased emphasis on the organs in the head and neck region. Hence to optimize radiation protection of personnel, the use of radiation-protective shielding for this region becomes more important.
- 19 June 2007
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 179 (7) , 728-732
Wie konservativ ist die Abschätzung der effektiven Dosis durch die amtliche Personendosimetrie für das Personal in der Radiologie?
Ziel: Die Werte der effektiven Dosis des Personals werden üblicherweise mit den Ergebnissen der amtlichen Personendosimetrie gleichgesetzt. In der vorliegenden Studie wird die Variationsbreite ermittelt, mit der die beiden Größen unter Berücksichtigung verschiedener Einflussfaktoren voneinander abweichen. Material und Methoden: Die Dosisbestimmung erfolgt mithilfe von Thermolumineszenzdosimetern für fünf unterschiedliche Geometrien von Patient und Personal an drei radiologischen Arbeitsplätzen. Patient und Personal werden dabei jeweils von einem antropomorphen Phantom simuliert. Unterschiedliche Ausführungen von persönlichen Schutzausrüstungen und der Einfluss der Dauerschutzeinrichtungen werden rechnerisch einbezogen. Ergebnisse: Die Personendosimetrie stellt nur für bestimmte Strahlenschutzsituationen eine konservative Abschätzung dar. Bei einem maximalen persönlichen Strahlenschutz (Rundum-Schürze mit Schilddrüsenschutz) erhält man Werte für das Verhältnis der effektiven Dosis zur Personendosis von 0,6 bis 1,25. Bei fehlendem Schilddrüsenschutz unterschätzt die amtliche Personendosis die effektive Dosis systematisch: Für Schutzkleidung mit 0,5 mm Pb ohne Schilddrüsenschutz ist die effektive Dosis um einen Faktor 1,70 bis 3,10 größer als die Personendosis, für Schutzkleidung mit 0,35 mm Pb entsprechend um einen Faktor 1,10 bis 1,82. Schlussfolgerung: Die amtlichen Messvorschriften zur Abschätzung der effektiven Dosis des strahlenexponierten Personals sind nur ungenügend an die Bedürfnisse in der Radiologie angepasst. Es wären Messverfahren wünschenswert, die ein mögliches Unterschätzen der effektiven Dosis vermeiden ließen. Die dargestellten Ergebnisse bieten die Möglichkeit, realitätsnähere Werte für die effektive Dosis aus den Dosiswerten der Personendosimetrie abzuleiten. Purpose: Dose values obtained by official personal radiation exposure monitoring are often considered equivalent to the effective dose of a person. This paper provides estimates of the extent of deviation between the two dose concepts under various conditions. Materials and Methods: Doses for patients and personnel were measured using thermoluminescence dosimeters for five different geometries at three work settings in a radiology department. Patients and personnel were simulated with anthropomorphic phantoms. Different types of protective clothing as well as permanent protection shields were considered in the calculations. Results: Dose values obtained by official personal dose monitoring are conservative only for specific radiation protection situations. With state-of-the-art personal protective equipment (wrap-around style lead apron with thyroid shield), the ratio between effective dose and personal dose varies between 0.6 and 1.25. Without thyroid protection the official personal dose systematically underestimates the effective dose: for protective clothing with 0.5 mm lead equivalent without thyroid shielding, the effective dose exceeds the personal dose by factors between 1.7 and 3.1. If protective clothing with lead equivalent 0.35 mm is used, this factor varies between 1.1 and 1.82. Conclusion: The official exposure monitoring algorithms for estimating the effective dose for occupationally exposed personnel are not always appropriate for typical situations in diagnostic radiology. Improved dose measurement protocols should avoid underestimation of the effective dose. The results presented herein provide an opportunity to derive more realistic effective dose values from personal dosimetry measurements.
- 19 June 2007
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 179 (7) , 728-732
Wie konservativ ist die Abschätzung der effektiven Dosis durch die amtliche Personendosimetrie für das Personal in der Radiologie?
Ziel: Die Werte der effektiven Dosis des Personals werden üblicherweise mit den Ergebnissen der amtlichen Personendosimetrie gleichgesetzt. In der vorliegenden Studie wird die Variationsbreite ermittelt, mit der die beiden Größen unter Berücksichtigung verschiedener Einflussfaktoren voneinander abweichen. Material und Methoden: Die Dosisbestimmung erfolgt mithilfe von Thermolumineszenzdosimetern für fünf unterschiedliche Geometrien von Patient und Personal an drei radiologischen Arbeitsplätzen. Patient und Personal werden dabei jeweils von einem antropomorphen Phantom simuliert. Unterschiedliche Ausführungen von persönlichen Schutzausrüstungen und der Einfluss der Dauerschutzeinrichtungen werden rechnerisch einbezogen. Ergebnisse: Die Personendosimetrie stellt nur für bestimmte Strahlenschutzsituationen eine konservative Abschätzung dar. Bei einem maximalen persönlichen Strahlenschutz (Rundum-Schürze mit Schilddrüsenschutz) erhält man Werte für das Verhältnis der effektiven Dosis zur Personendosis von 0,6 bis 1,25. Bei fehlendem Schilddrüsenschutz unterschätzt die amtliche Personendosis die effektive Dosis systematisch: Für Schutzkleidung mit 0,5 mm Pb ohne Schilddrüsenschutz ist die effektive Dosis um einen Faktor 1,70 bis 3,10 größer als die Personendosis, für Schutzkleidung mit 0,35 mm Pb entsprechend um einen Faktor 1,10 bis 1,82. Schlussfolgerung: Die amtlichen Messvorschriften zur Abschätzung der effektiven Dosis des strahlenexponierten Personals sind nur ungenügend an die Bedürfnisse in der Radiologie angepasst. Es wären Messverfahren wünschenswert, die ein mögliches Unterschätzen der effektiven Dosis vermeiden ließen. Die dargestellten Ergebnisse bieten die Möglichkeit, realitätsnähere Werte für die effektive Dosis aus den Dosiswerten der Personendosimetrie abzuleiten. Purpose: Dose values obtained by official personal radiation exposure monitoring are often considered equivalent to the effective dose of a person. This paper provides estimates of the extent of deviation between the two dose concepts under various conditions. Materials and Methods: Doses for patients and personnel were measured using thermoluminescence dosimeters for five different geometries at three work settings in a radiology department. Patients and personnel were simulated with anthropomorphic phantoms. Different types of protective clothing as well as permanent protection shields were considered in the calculations. Results: Dose values obtained by official personal dose monitoring are conservative only for specific radiation protection situations. With state-of-the-art personal protective equipment (wrap-around style lead apron with thyroid shield), the ratio between effective dose and personal dose varies between 0.6 and 1.25. Without thyroid protection the official personal dose systematically underestimates the effective dose: for protective clothing with 0.5 mm lead equivalent without thyroid shielding, the effective dose exceeds the personal dose by factors between 1.7 and 3.1. If protective clothing with lead equivalent 0.35 mm is used, this factor varies between 1.1 and 1.82. Conclusion: The official exposure monitoring algorithms for estimating the effective dose for occupationally exposed personnel are not always appropriate for typical situations in diagnostic radiology. Improved dose measurement protocols should avoid underestimation of the effective dose. The results presented herein provide an opportunity to derive more realistic effective dose values from personal dosimetry measurements.
- 1 April 2007
- Published by Wolters Kluwer Health in Health Physics
- Vol. 92 (4) , 315-331
A MODEL AND REFERENCE DATA FOR RETROSPECTIVE DOSE ASSESSMENT OF ORGAN DOSES (RED BONE MARROW, LYMPHATIC SYSTEM) IN DIAGNOSTIC RADIOGRAPHY AND NUCLEAR MEDICINE, 1946–1995
Retrospective dosimetry for radiologic and nuclear medicine examinations has been a challenge both for individual patients and in epidemiologic studies. Methodological problems include the large range of patient exposures from radiologic examinations, which spans over three orders of magnitude, the considerable dose reduction over time for most types of examinations due to technical advancements, and the increasing concern for radiation protection and quality issues in radiologic practice. A three-step model for retrospective dosimetry for patient exposure is presented that allows determination of organ doses to the red bone marrow and the lymphatic tissue, respectively, for typical examinations over the time period 1946-1995. The model starts from a set of doses assuming ideal technical equipment and radiologic practice. Step II considers the advancement of technical equipment over the different decades since the introduction of medical radiology in the early 1940's. Step III refers to quality in radiologic routine and allows for adjustment for less-than-ideal standards of radiologic practice. Model parameters are derived from contemporary literature and a multitude of historical sources. Tables with reference data are provided that allow a straightforward application of the model in the context of analytic epidemiologic studies. Wherever possible, reference doses are based on dose area product to allow for easy adjustment to different settings and inclusion of prospective data. The model and the results can be readily extended to different countries with different technical advancement and standard of radiologic practice.
- 1 April 2007
- Published by Wolters Kluwer Health in Health Physics
- Vol. 92 (4) , 315-331
A MODEL AND REFERENCE DATA FOR RETROSPECTIVE DOSE ASSESSMENT OF ORGAN DOSES (RED BONE MARROW, LYMPHATIC SYSTEM) IN DIAGNOSTIC RADIOGRAPHY AND NUCLEAR MEDICINE, 1946–1995
Retrospective dosimetry for radiologic and nuclear medicine examinations has been a challenge both for individual patients and in epidemiologic studies. Methodological problems include the large range of patient exposures from radiologic examinations, which spans over three orders of magnitude, the considerable dose reduction over time for most types of examinations due to technical advancements, and the increasing concern for radiation protection and quality issues in radiologic practice. A three-step model for retrospective dosimetry for patient exposure is presented that allows determination of organ doses to the red bone marrow and the lymphatic tissue, respectively, for typical examinations over the time period 1946-1995. The model starts from a set of doses assuming ideal technical equipment and radiologic practice. Step II considers the advancement of technical equipment over the different decades since the introduction of medical radiology in the early 1940's. Step III refers to quality in radiologic routine and allows for adjustment for less-than-ideal standards of radiologic practice. Model parameters are derived from contemporary literature and a multitude of historical sources. Tables with reference data are provided that allow a straightforward application of the model in the context of analytic epidemiologic studies. Wherever possible, reference doses are based on dose area product to allow for easy adjustment to different settings and inclusion of prospective data. The model and the results can be readily extended to different countries with different technical advancement and standard of radiologic practice.
- 10 February 2006
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 178 (03) , 287-291
Optimierung des Strahlenschutzes für das Personal in der Radiologie auf Grundlage der effektiven Dosis
Ziel: Die vorliegende Studie empfiehlt eine Optimierung der Strahlenschutzausrüstung des Personals zur Reduzierung der effektiven Dosis, da die stochastischen Strahlenwirkungen mit der effektiven Dosis korreliert sind. Material und Methode: Die Dosisbestimmung erfolgt mithilfe von Thermolumineszensdosimetern und zwei Alderson-Phantomen, von denen das eine den Patienten, das andere das Personal simuliert. Unterschiedliche Ausführungen von persönlichen Schutzausrüstungen und der Einfluss von Dauerschutzeinrichtungen werden rechnerisch einbezogen. Ergebnisse: Es wird gezeigt, dass die Dosen der nichtabgeschirmten Organe (Schilddrüse, Teile des roten Knochenmarks) erheblich zur effektiven Dosis des Personals beitragen und dass daher keine lineare Beziehung zwischen dem Abschwächungsfaktor des Strahlenschutzzubehörs und der effektiven Dosis besteht. Ein zusätzlicher Schilddrüsenschutz reduziert die effektive Dosis um einen Faktor 1,7 - 3,0. Röntgenschutzkleidung mit 0,35 mm Bleiäquivalent und einem zusätzlichen Schilddrüsenschutz bietet einen besseren Strahlenschutz als eine Schutzkleidung mit 0,5 mm Bleigleichwert ohne Schilddrüsenschutz. Schlussfolgerung: Ein Schilddrüsenschutz dient nicht nur dazu, Organdosis-Grenzwerte einzuhalten. Er reduziert auch die effektive Dosis deutlich. Der Schilddrüsenschutz sollte daher grundsätzlich Bestandteil der Strahlenschutzkleidung im Röntgenbereich sein. Purpose: In the present study the optimization of radiation protection devices is achieved by minimizing the effective dose of the staff members since the stochastic radiation effects correlate to the effective dose. Materials and Methods: Radiation exposure dosimetry was performed with TLD measurements using one Alderson Phantom in the patient position and a second phantom in the typical position of the personnel. Various types of protective clothing as well as fixed shields were considered in the calculations. Results: It was shown that the doses of the unshielded organs (thyroid, parts of the active bone marrow) contribute significantly to the effective dose of the staff. Therefore, there is no linear relationship between the shielding factors for protective garments and the effective dose. An additional thyroid protection collar reduces the effective dose by a factor of 1.7 - 3.0. X-ray protective clothing with a 0.35 mm lead equivalent and an additional thyroid protection collar provides better protection against radiation than an apron with a 0.5 mm lead equivalent but no collar. Conclusion: The use of thyroid protection collars is an effective preventive measure against exceeding occupational organ dose limits, and a thyroid shield also considerably reduces the effective dose. Therefore, thyroid protection collars should be a required component of anti-X protection.
- 10 February 2006
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 178 (03) , 287-291
Optimierung des Strahlenschutzes für das Personal in der Radiologie auf Grundlage der effektiven Dosis
Ziel: Die vorliegende Studie empfiehlt eine Optimierung der Strahlenschutzausrüstung des Personals zur Reduzierung der effektiven Dosis, da die stochastischen Strahlenwirkungen mit der effektiven Dosis korreliert sind. Material und Methode: Die Dosisbestimmung erfolgt mithilfe von Thermolumineszensdosimetern und zwei Alderson-Phantomen, von denen das eine den Patienten, das andere das Personal simuliert. Unterschiedliche Ausführungen von persönlichen Schutzausrüstungen und der Einfluss von Dauerschutzeinrichtungen werden rechnerisch einbezogen. Ergebnisse: Es wird gezeigt, dass die Dosen der nichtabgeschirmten Organe (Schilddrüse, Teile des roten Knochenmarks) erheblich zur effektiven Dosis des Personals beitragen und dass daher keine lineare Beziehung zwischen dem Abschwächungsfaktor des Strahlenschutzzubehörs und der effektiven Dosis besteht. Ein zusätzlicher Schilddrüsenschutz reduziert die effektive Dosis um einen Faktor 1,7 - 3,0. Röntgenschutzkleidung mit 0,35 mm Bleiäquivalent und einem zusätzlichen Schilddrüsenschutz bietet einen besseren Strahlenschutz als eine Schutzkleidung mit 0,5 mm Bleigleichwert ohne Schilddrüsenschutz. Schlussfolgerung: Ein Schilddrüsenschutz dient nicht nur dazu, Organdosis-Grenzwerte einzuhalten. Er reduziert auch die effektive Dosis deutlich. Der Schilddrüsenschutz sollte daher grundsätzlich Bestandteil der Strahlenschutzkleidung im Röntgenbereich sein. Purpose: In the present study the optimization of radiation protection devices is achieved by minimizing the effective dose of the staff members since the stochastic radiation effects correlate to the effective dose. Materials and Methods: Radiation exposure dosimetry was performed with TLD measurements using one Alderson Phantom in the patient position and a second phantom in the typical position of the personnel. Various types of protective clothing as well as fixed shields were considered in the calculations. Results: It was shown that the doses of the unshielded organs (thyroid, parts of the active bone marrow) contribute significantly to the effective dose of the staff. Therefore, there is no linear relationship between the shielding factors for protective garments and the effective dose. An additional thyroid protection collar reduces the effective dose by a factor of 1.7 - 3.0. X-ray protective clothing with a 0.35 mm lead equivalent and an additional thyroid protection collar provides better protection against radiation than an apron with a 0.5 mm lead equivalent but no collar. Conclusion: The use of thyroid protection collars is an effective preventive measure against exceeding occupational organ dose limits, and a thyroid shield also considerably reduces the effective dose. Therefore, thyroid protection collars should be a required component of anti-X protection.
- 1 January 2003
- Vol. 13 (2) , 123-6
[Gender-specific calculation of the effective dose with an example of thoracic CT tomography].
Systematic gender-specific differences in anatomy and physiology are mostly neglected in standard methodologies for the determination of effective doses. This paper presents and discusses three different concepts for the derivation of gender-specific effective doses. Based on the most convincing approach--especially through the influence of tissue weighting factors for the breast--the effective dose for a serial CT scan of the chest is higher for women (+11%) and lower (-11%) for men in comparison to the "gender-neutral" average value. These differences amount to +/- 30% for coronary serial CT applications.
- 1 January 2003
- Vol. 13 (2) , 123-6
[Gender-specific calculation of the effective dose with an example of thoracic CT tomography].
Systematic gender-specific differences in anatomy and physiology are mostly neglected in standard methodologies for the determination of effective doses. This paper presents and discusses three different concepts for the derivation of gender-specific effective doses. Based on the most convincing approach--especially through the influence of tissue weighting factors for the breast--the effective dose for a serial CT scan of the chest is higher for women (+11%) and lower (-11%) for men in comparison to the "gender-neutral" average value. These differences amount to +/- 30% for coronary serial CT applications.
- 1 January 2003
- Vol. 13 (4) , 251-6
[Radiation exposure to personnel in cardiac catheterization laboratories].
Radiation exposure in personnel of cardiac catheterization units is based on local dosimetry during patient investigations. In the present study, dose rates were measured at various heights in representative locations, with and without fixed radiation protection shields in place. To determine the effective dose values, TLD measurements were performed using on Alderson phantom to generate radiation scatter and a second phantom in the position of the cardiologist performing the catheterization. Various types of personal radiation protection garment and fixed shields were considered in the calculations. Our results indicate on one hand that good protective standards can be achieved with effective doses below 1 mSv/year under optimized conditions. On the other hand, inappropriate radiation protection equipment can cause substantial increase of radiation doses. Alone the lack of a thyroid shield increases the effective dose of the cardiologist by a factor of 3. For the personnel, effective doses were generally higher than personal doses by a factor between 1.5 and 4.8 depending on the radiation protection situation.
- 1 January 2003
- Vol. 13 (4) , 251-6
[Radiation exposure to personnel in cardiac catheterization laboratories].
Radiation exposure in personnel of cardiac catheterization units is based on local dosimetry during patient investigations. In the present study, dose rates were measured at various heights in representative locations, with and without fixed radiation protection shields in place. To determine the effective dose values, TLD measurements were performed using on Alderson phantom to generate radiation scatter and a second phantom in the position of the cardiologist performing the catheterization. Various types of personal radiation protection garment and fixed shields were considered in the calculations. Our results indicate on one hand that good protective standards can be achieved with effective doses below 1 mSv/year under optimized conditions. On the other hand, inappropriate radiation protection equipment can cause substantial increase of radiation doses. Alone the lack of a thyroid shield increases the effective dose of the cardiologist by a factor of 3. For the personnel, effective doses were generally higher than personal doses by a factor between 1.5 and 4.8 depending on the radiation protection situation.