Tiqiao Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tiqiao Xiao has a total of 287 co-authors. Here are the top co-authors by number of shared publications:
Guohao Du
Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, No. 239 Zhangheng Road, Shanghai 201204, China
13 shared publicationsBiao Deng
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China
12 shared publicationsKe Li
12 shared publications- Honglan Xie
Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China
9 shared publications - Biao Deng
Shanghai Synchrotron Radiation Facility/Zhangjiang Laboratory, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
8 shared publications Honglan Xie
Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai, China
8 shared publications
Latest Publications
- Open Access
- 1 January 2027
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 76 (4)
X-ray phase contrast dynamic micro-CT
X射线相位衬度动态显微CT技术利用高亮度、高相干性同步辐射X射线源,协同高速转台与高性能探测器,可实现对轻元素材料内部三维微结构演化的微米级空间分辨与毫秒级时间分辨四维观测,在材料科学、生物医学、能源环境等领域展现出广阔的应用前景。本文系统梳理了该技术的成像原理、光源特性、核心硬件、控制及同步系统和数据处理分析方法,分析了各系统的技术现状并给出定性或定量信息,指出其发展趋势与面临的挑战。随着X射线相位衬度动态显微CT各软硬件系统性能的持续提升,尤其是深度学习算法与物理模型的深度融合,该技术有望发展成为一种兼具超高时空分辨与智能数据处理能力的多维、多模态科学实验方法。
- 1 January 2027
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 76 (4)
Open AccessX-ray phase contrast dynamic micro-CT
X射线相位衬度动态显微CT技术利用高亮度、高相干性同步辐射X射线源,协同高速转台与高性能探测器,可实现对轻元素材料内部三维微结构演化的微米级空间分辨与毫秒级时间分辨四维观测,在材料科学、生物医学、能源环境等领域展现出广阔的应用前景。本文系统梳理了该技术的成像原理、光源特性、核心硬件、控制及同步系统和数据处理分析方法,分析了各系统的技术现状并给出定性或定量信息,指出其发展趋势与面临的挑战。随着X射线相位衬度动态显微CT各软硬件系统性能的持续提升,尤其是深度学习算法与物理模型的深度融合,该技术有望发展成为一种兼具超高时空分辨与智能数据处理能力的多维、多模态科学实验方法。
- Open Access
- 4 June 2026
- Published by Elsevier in Electrochimica Acta
- Vol. 573
Operando visualization of ion migration dynamics with micrometer-millisecond resolution
- 4 June 2026
- Published by Elsevier in Electrochimica Acta
- Vol. 573
Open AccessOperando visualization of ion migration dynamics with micrometer-millisecond resolution
- Open Access
Melt-Pool Dynamics Quantification in LPBF via Move Contrast X-Ray Imaging
The dynamic behavior within the melt pool governs the final quality of components fabricated by laser powder bed fusion (LPBF). To address key technical challenges—rapid keyhole evolution, low absorption contrast from metal vapor, and difficulties in quantifying internal flow fields—this study introduces move contrast X-ray imaging (MCXI), a technique leveraging time-series frequency characteristics. Combined with a multi-scale Horn–Schunck global optical flow method, MCXI enables full-field quantitative extraction of the melt-pool velocity field. Experimental validation across feature points shows a relative deviation of less than 2% compared to independent manual feature-point tracking, confirming consistency with the best available experimental ground truth. Analysis reveals the keyhole tail evolution cycle comprises three distinct dynamic stages: expansion, stratification, and contraction, with its area increasing from 1329 μm2 to 6508 μm2 before stabilizing. For the first time, pore pinch-off events were quantitatively measured, revealing front and rear wall collision velocities of 7.98 m/s and 8.04 m/s, respectively, consistent with available high-fidelity simulations. Furthermore, analysis of the overall melt-pool momentum field demonstrates a near-equal distribution of positive and negative momentum, providing an internal self-consistency check confirming the absence of systematic directional bias in the extracted velocity field. This study enables quantitative analysis of LPBF melt-pool dynamics, providing a novel tool for process optimization and defect control.
Open AccessMelt-Pool Dynamics Quantification in LPBF via Move Contrast X-Ray Imaging
The dynamic behavior within the melt pool governs the final quality of components fabricated by laser powder bed fusion (LPBF). To address key technical challenges—rapid keyhole evolution, low absorption contrast from metal vapor, and difficulties in quantifying internal flow fields—this study introduces move contrast X-ray imaging (MCXI), a technique leveraging time-series frequency characteristics. Combined with a multi-scale Horn–Schunck global optical flow method, MCXI enables full-field quantitative extraction of the melt-pool velocity field. Experimental validation across feature points shows a relative deviation of less than 2% compared to independent manual feature-point tracking, confirming consistency with the best available experimental ground truth. Analysis reveals the keyhole tail evolution cycle comprises three distinct dynamic stages: expansion, stratification, and contraction, with its area increasing from 1329 μm2 to 6508 μm2 before stabilizing. For the first time, pore pinch-off events were quantitatively measured, revealing front and rear wall collision velocities of 7.98 m/s and 8.04 m/s, respectively, consistent with available high-fidelity simulations. Furthermore, analysis of the overall melt-pool momentum field demonstrates a near-equal distribution of positive and negative momentum, providing an internal self-consistency check confirming the absence of systematic directional bias in the extracted velocity field. This study enables quantitative analysis of LPBF melt-pool dynamics, providing a novel tool for process optimization and defect control.
- 26 February 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (9) , 6976-6985
Grayscale-Element Bayesian Method Based on Synchrotron Radiation Nano-CT: Quantitative Characterization of Elemental Content and Heterogeneity
Achieving nondestructive, high-precision quantitative elemental analysis at the nanoscale has long been a challenge in materials characterization. The proposed Grayscale Bayesian Elemental Quantification Analysis (GBEQA) method effectively circumvents issues such as insufficient detection depth, destructiveness, and matrix effects encountered by conventional techniques by integrating grayscale information from synchrotron radiation nano-CT with a Bayesian inversion framework. By constructing a grayscale probability model and generating probability mass functions through convolution with standard materials, GBEQA achieves unsupervised element quantification without requiring prior knowledge for the first time. The validation on FeNi alloys and Ni0.9Co0.05Mn0.05(OH)2 (NCM90 precursor) demonstrates high agreement with inductively coupled plasma atomic emission spectrometry (ICP-AES) while successfully characterizing nanoscale element distribution heterogeneities inaccessible to conventional techniques. This study establishes a novel paradigm for elemental analysis that combines nondestructive, 3D resolution, and universality, holding significant implications for advancing research on complex systems such as alloys and energy materials.
- 26 February 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (9) , 6976-6985
Grayscale-Element Bayesian Method Based on Synchrotron Radiation Nano-CT: Quantitative Characterization of Elemental Content and Heterogeneity
Achieving nondestructive, high-precision quantitative elemental analysis at the nanoscale has long been a challenge in materials characterization. The proposed Grayscale Bayesian Elemental Quantification Analysis (GBEQA) method effectively circumvents issues such as insufficient detection depth, destructiveness, and matrix effects encountered by conventional techniques by integrating grayscale information from synchrotron radiation nano-CT with a Bayesian inversion framework. By constructing a grayscale probability model and generating probability mass functions through convolution with standard materials, GBEQA achieves unsupervised element quantification without requiring prior knowledge for the first time. The validation on FeNi alloys and Ni0.9Co0.05Mn0.05(OH)2 (NCM90 precursor) demonstrates high agreement with inductively coupled plasma atomic emission spectrometry (ICP-AES) while successfully characterizing nanoscale element distribution heterogeneities inaccessible to conventional techniques. This study establishes a novel paradigm for elemental analysis that combines nondestructive, 3D resolution, and universality, holding significant implications for advancing research on complex systems such as alloys and energy materials.
- 9 February 2026
- Published by Springer Nature in Neuroscience Bulletin
- Vol. 42 (4) , 931-936
Comparison of Freeze-drying and Gradient Dehydration Treatment on X-ray Imaging for Three-dimensional Reconstruction of Early Human Embryonic Brain Samples
- 9 February 2026
- Published by Springer Nature in Neuroscience Bulletin
- Vol. 42 (4) , 931-936
Comparison of Freeze-drying and Gradient Dehydration Treatment on X-ray Imaging for Three-dimensional Reconstruction of Early Human Embryonic Brain Samples
- 3 November 2025
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 34 (1) , 92-102
X-ray white beam based 26.7 Hz dynamic tomography
Synchrotron radiation micro-computed tomography (SR-µCT) is a vital technique for the quantitative characterization of three-dimensional internal structures across diverse fields, including energy, integrated circuits, materials science, biomedicine, archaeology etc. While SR-µCT provides high spatial resolution and high image contrast, it typically offers only moderate temporal resolution, with acquisition times ranging from minutes to hours. Recently, dynamic SR-µCT has attracted significant interest for its capacity to capture real-time three-dimensional structural evolution. Here, we demonstrate a dynamic SR-µCT system operating at 26.7 Hz, developed at the BL09B test beamline of the Shanghai Synchrotron Radiation Facility using a filtered white beam. The key components of this system include an air-cooling millisecond fast shutter, an air-bearing rotation stage, a high-efficiency detector integrated with a Photron FASTCAM SA-Z camera and a custom-designed optical system, and a synchronization clock to ensure precise temporal alignment of all devices. Experimental results confirm the feasibility of this approach for in vivo four-dimensional studies, making it particularly promising for applications in biomedical research and related disciplines.
- 3 November 2025
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 34 (1) , 92-102
X-ray white beam based 26.7 Hz dynamic tomography
Synchrotron radiation micro-computed tomography (SR-µCT) is a vital technique for the quantitative characterization of three-dimensional internal structures across diverse fields, including energy, integrated circuits, materials science, biomedicine, archaeology etc. While SR-µCT provides high spatial resolution and high image contrast, it typically offers only moderate temporal resolution, with acquisition times ranging from minutes to hours. Recently, dynamic SR-µCT has attracted significant interest for its capacity to capture real-time three-dimensional structural evolution. Here, we demonstrate a dynamic SR-µCT system operating at 26.7 Hz, developed at the BL09B test beamline of the Shanghai Synchrotron Radiation Facility using a filtered white beam. The key components of this system include an air-cooling millisecond fast shutter, an air-bearing rotation stage, a high-efficiency detector integrated with a Photron FASTCAM SA-Z camera and a custom-designed optical system, and a synchronization clock to ensure precise temporal alignment of all devices. Experimental results confirm the feasibility of this approach for in vivo four-dimensional studies, making it particularly promising for applications in biomedical research and related disciplines.
- 25 August 2025
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 33 (6) , 1071-1080
Generalization of parallel ghost imaging based on laboratory X-ray source
Ghost imaging is an imaging technique that achieves image reconstruction by measuring the intensity correlation function between the reference arm and the object arm. In parallel ghost imaging, each pixel of a position-sensitive detector is further regarded as a bucket detector, enabling the parallel acquisition of hundreds or thousands of ghost imaging subsystems in a single measurement, thus realizing high-resolution imaging with extremely low measurement counts. Relying on synchrotron radiation, we have achieved X-ray parallel ghost imaging with high pixel resolution, low dose, and ultra-large field of view. However, the dependence of X-ray parallel ghost imaging on synchrotron radiation has set extremely high thresholds for the dissemination and application of this technology. In this work, we broke away from synchrotron radiation facility and completed the pipeline-style acquisition of parallel ghost imaging using rough and inexpensive equipment in the most reproducible way for others. Eventually, we achieved ghost imaging with an effective pixel size of 8.03 μm, an image size of 2880 × 2280, and a minimum of 10 measurement numbers (a sampling rate of 0.62%) using a laboratory X-ray light source. It can be achieved merely by making minor modifications to any industrial CT device. With a total experimental cost of only $40, this work demonstrates great universality. We have put forward a comprehensive framework for the practical application of parallel ghost imaging, which is an essential prerequisite for the generalization of parallel ghost imaging to enter the commercial and practical arenas.
- 25 August 2025
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 33 (6) , 1071-1080
Generalization of parallel ghost imaging based on laboratory X-ray source
Ghost imaging is an imaging technique that achieves image reconstruction by measuring the intensity correlation function between the reference arm and the object arm. In parallel ghost imaging, each pixel of a position-sensitive detector is further regarded as a bucket detector, enabling the parallel acquisition of hundreds or thousands of ghost imaging subsystems in a single measurement, thus realizing high-resolution imaging with extremely low measurement counts. Relying on synchrotron radiation, we have achieved X-ray parallel ghost imaging with high pixel resolution, low dose, and ultra-large field of view. However, the dependence of X-ray parallel ghost imaging on synchrotron radiation has set extremely high thresholds for the dissemination and application of this technology. In this work, we broke away from synchrotron radiation facility and completed the pipeline-style acquisition of parallel ghost imaging using rough and inexpensive equipment in the most reproducible way for others. Eventually, we achieved ghost imaging with an effective pixel size of 8.03 μm, an image size of 2880 × 2280, and a minimum of 10 measurement numbers (a sampling rate of 0.62%) using a laboratory X-ray light source. It can be achieved merely by making minor modifications to any industrial CT device. With a total experimental cost of only $40, this work demonstrates great universality. We have put forward a comprehensive framework for the practical application of parallel ghost imaging, which is an essential prerequisite for the generalization of parallel ghost imaging to enter the commercial and practical arenas.
- Open Access
- 31 July 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (5) , 1310-1318
Arbitrary thickness profile metrology of low- Z and monolithic material components with a single X-ray projection
Low- Z and monolithic material components with arbitrary thickness profiles are extensively utilized in heat conduction, biocompatible implants, microfluidics and integrated optics, where precise thickness measurement is crucial for quality control and performance analysis. X-ray micro-computed tomography (micro-CT) is widely employed for thickness metrology of such samples due to its nondestructive nature, high resolution and 3D imaging capabilities. However, the time-consuming projection acquisition and image reconstruction processes hinder it from efficient or dynamic thickness measurements. Additionally, micro-CT struggles with laminar samples. To overcome these limitations, we introduce X-ray phase contrast imaging for the thickness metrology of low- Z materials with arbitrary profiles by accurately retrieving the phase shift of X-rays passing through the sample from a single projection. Calibration using a standard nylon fiber demonstrates that within a 1.33 mm field of view (FOV) the method achieves a mean absolute error of 0.68 µm for cylindrical fibers with diameters of 407.14 µm. We further demonstrate the method's capability for efficient measurement and damage assessment using a worn fiber with complex geometry. Additionally, we applied this method to the thickness measurement and error analysis of a microlens array with varying sub-lens parameters. The 3D profiles of all sub-lenses were obtained from a single projection, facilitating error analysis of height, symmetry and eccentricity. The results highlight the method's advantages, including being in situ , non-contact and high precision, and having a large FOV, flexible adjustability and penetrative measurement capabilities. Our open device design suggests potential applications for dynamic thickness measurements and real-time monitoring of samples within in situ loading devices.
- 31 July 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (5) , 1310-1318
Open AccessArbitrary thickness profile metrology of low- Z and monolithic material components with a single X-ray projection
Low- Z and monolithic material components with arbitrary thickness profiles are extensively utilized in heat conduction, biocompatible implants, microfluidics and integrated optics, where precise thickness measurement is crucial for quality control and performance analysis. X-ray micro-computed tomography (micro-CT) is widely employed for thickness metrology of such samples due to its nondestructive nature, high resolution and 3D imaging capabilities. However, the time-consuming projection acquisition and image reconstruction processes hinder it from efficient or dynamic thickness measurements. Additionally, micro-CT struggles with laminar samples. To overcome these limitations, we introduce X-ray phase contrast imaging for the thickness metrology of low- Z materials with arbitrary profiles by accurately retrieving the phase shift of X-rays passing through the sample from a single projection. Calibration using a standard nylon fiber demonstrates that within a 1.33 mm field of view (FOV) the method achieves a mean absolute error of 0.68 µm for cylindrical fibers with diameters of 407.14 µm. We further demonstrate the method's capability for efficient measurement and damage assessment using a worn fiber with complex geometry. Additionally, we applied this method to the thickness measurement and error analysis of a microlens array with varying sub-lens parameters. The 3D profiles of all sub-lenses were obtained from a single projection, facilitating error analysis of height, symmetry and eccentricity. The results highlight the method's advantages, including being in situ , non-contact and high precision, and having a large FOV, flexible adjustability and penetrative measurement capabilities. Our open device design suggests potential applications for dynamic thickness measurements and real-time monitoring of samples within in situ loading devices.
- Open Access
- 22 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8137
Parallel Ghost Imaging with Extra Large Field of View and High Pixel Resolution
Ghost imaging (GI) facilitates image acquisition under low-light conditions through single pixel measurements, thus holding tremendous potential across various fields such as biomedical imaging, remote sensing, defense and military applications, and 3D imaging. However, in order to reconstruct high-resolution images, GI typically requires a large number of single-pixel measurements, which imposes practical limitations on its application. Parallel ghost imaging addresses this issue by utilizing each pixel of a position-sensitive detector as a bucket detector to simultaneously perform tens of thousands of ghost imaging measurements in parallel. In this work, we explore the non-local characteristics of ghost imaging in depth, and by constructing a large speckle space, we achieve a reconstruction result in parallel ghost imaging where the field of view surpasses the limitations of the reference arm detector. Using a computational ghost imaging framework, after pre-recording the speckle patterns, we are able to complete X-ray ghost imaging at a speed of 6 min per sample, with image dimensions of 14,000 × 10,000 pixels (4.55 mm × 3.25 mm, millimeter-scale field of view) and a pixel resolution of 0.325 µm (sub-micron pixel resolution). We present this framework to enhance efficiency, extend resolution, and dramatically expand the field of view, with the aim of providing a solution for the practical implementation of ghost imaging.
- 22 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8137
Open AccessParallel Ghost Imaging with Extra Large Field of View and High Pixel Resolution
Ghost imaging (GI) facilitates image acquisition under low-light conditions through single pixel measurements, thus holding tremendous potential across various fields such as biomedical imaging, remote sensing, defense and military applications, and 3D imaging. However, in order to reconstruct high-resolution images, GI typically requires a large number of single-pixel measurements, which imposes practical limitations on its application. Parallel ghost imaging addresses this issue by utilizing each pixel of a position-sensitive detector as a bucket detector to simultaneously perform tens of thousands of ghost imaging measurements in parallel. In this work, we explore the non-local characteristics of ghost imaging in depth, and by constructing a large speckle space, we achieve a reconstruction result in parallel ghost imaging where the field of view surpasses the limitations of the reference arm detector. Using a computational ghost imaging framework, after pre-recording the speckle patterns, we are able to complete X-ray ghost imaging at a speed of 6 min per sample, with image dimensions of 14,000 × 10,000 pixels (4.55 mm × 3.25 mm, millimeter-scale field of view) and a pixel resolution of 0.325 µm (sub-micron pixel resolution). We present this framework to enhance efficiency, extend resolution, and dramatically expand the field of view, with the aim of providing a solution for the practical implementation of ghost imaging.
- Open Access
- 19 June 2025
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 13, 1615591
Megapixel X-ray ghost imaging with a prior-recorded reference
Introduction: Efficient implementation of X-ray ghost imaging (XGI) with megapixel-level field-of-view and spatial resolution of few microns is key towards practical applications of XGI, but such implementation remains constrained by the time-consuming data acquisition and low-quality reconstruction for megapixel images under insufficient overall sampling rates.Methods: We propose an efficient implementation scheme based on synthetic aperture X-ray ghost imaging (SAXGI), in which only one set of prior-recorded reference images is needed for ghost imaging of multiple objects.Results: Experimental results demonstrated that images of three different objects, including tungsten fiber, resolution chart and small fish, can be successfully reconstructed with the same set of prior-recorded references, which implicates that the efficiency of data acquisition can be improved significantly. Taking advantage of SAXGI, image size of 2040 × 1440 pixels and system resolution of 10 μm was achieved. Results of a small fish show that comparable image quality is achieved with a sampling rate of 27.6%, which means that the radiation dose is reduced to about 1/4 of a conventional radiography. Furthermore, an extreme sampling rate down to 0.5% is enough to make out the skeleton of the fish, which further demonstrates high robustness and the low-dose potential of the proposed method for X-ray imaging.Conclusions: In conclusion, the proposed method with a prior-recorded reference is applicable for XGI of multiple samples and the data acquisition efficiency is greatly improved. Through further hardware improvement of the imaging system, SAXGI with a prior-recorded reference is anticipated to provide an efficient solution for megapixel X-ray ghost imaging.
- 19 June 2025
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 13, 1615591
Open AccessMegapixel X-ray ghost imaging with a prior-recorded reference
Introduction: Efficient implementation of X-ray ghost imaging (XGI) with megapixel-level field-of-view and spatial resolution of few microns is key towards practical applications of XGI, but such implementation remains constrained by the time-consuming data acquisition and low-quality reconstruction for megapixel images under insufficient overall sampling rates.Methods: We propose an efficient implementation scheme based on synthetic aperture X-ray ghost imaging (SAXGI), in which only one set of prior-recorded reference images is needed for ghost imaging of multiple objects.Results: Experimental results demonstrated that images of three different objects, including tungsten fiber, resolution chart and small fish, can be successfully reconstructed with the same set of prior-recorded references, which implicates that the efficiency of data acquisition can be improved significantly. Taking advantage of SAXGI, image size of 2040 × 1440 pixels and system resolution of 10 μm was achieved. Results of a small fish show that comparable image quality is achieved with a sampling rate of 27.6%, which means that the radiation dose is reduced to about 1/4 of a conventional radiography. Furthermore, an extreme sampling rate down to 0.5% is enough to make out the skeleton of the fish, which further demonstrates high robustness and the low-dose potential of the proposed method for X-ray imaging.Conclusions: In conclusion, the proposed method with a prior-recorded reference is applicable for XGI of multiple samples and the data acquisition efficiency is greatly improved. Through further hardware improvement of the imaging system, SAXGI with a prior-recorded reference is anticipated to provide an efficient solution for megapixel X-ray ghost imaging.