Holger Eggebrecht
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Holger Eggebrecht has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
Raimund Erbel
Department of Cardiology, West‐German Heart Center Essen, University of Duisburg‐Essen, Germany
22 shared publicationsDietrich Baumgart
Department of Cardiology, West-German Heart Center Essen, Essen, Germany
13 shared publicationsAxel Schmermund
11 shared publicationsUlf Herold
Department of Cardio‐Thoracic Surgery, West‐German Heart Center Essen, University of Duisburg‐Essen, Germany
11 shared publicationsHeinz Jakob
Department of Cardiothoracic Surgery, West-German Heart Center Essen, Essen, Germany
7 shared publicationsClemens von Birgelen
Department of Cardiology, Medisch Spectrum Twente, Enschede, The Netherlands
6 shared publications
Latest Publications
- 31 December 2010
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 19, S120
Adoption of Percutaneous Transfemoral Aortic Valve Implantation and Procedural Developments
- 31 December 2010
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 19, S120
Adoption of Percutaneous Transfemoral Aortic Valve Implantation and Procedural Developments
- 1 January 2009
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 56 (S 01) , V205
Serial CT-volumetry confirms shrinking of the false lumen throughout the descending aorta after antegrade stentgrafting for aortic dissection
Objectives: In aortic dissection (AD) involving the aortic arch, arch replacement and open antegrade stentgrafting of the descending aorta represents a novel hybrid approach for one stage exclusion of the false (FL) lumen throughout the thoracic aorta. The present study demonstrates its midterm results regarding thrombosis of the FL along the entire aorta using a hybrid stentgraft prosthesis. Methods: From 02.2005 to 09.2008 35 patients (22 acute AD, 13 chronic AD) underwent aortic arch replacement and antegrade stentgrafting of the descending aorta. CT-scans were performed postoperatively and during the follow-up. CT-serial volume measurements of the FL and TL were performed at the proximal (A) and distal (B) stentgraft level, at the level between stentgraft-end and proximal abdominal aorta (C) and at the distal abdominal aorta (D). Results: In-hospital mortality was 3% (1/35). One patient underwent conventional reoperation of the descending aorta postoperatively for a nonrecognized third patent FL. The aorta of the remaining 33 patients was evaluated during a period of 17±11 months (mean±SD). Levels A and B demonstrated a significant shrinking of the FL and a growth of the TL (p0.05). After three additional secondary endovascular interventions for distal endoleak, complete thrombosis of the FL in the peristentgraft space achieved in 97% (32/33). Conclusion: Open antegrade stentgrafting of the descending aorta with this hybrid prosthesis promoted significant thrombosis and shrinking of the FL down to the aortic stentgraft end. CT-scans are required for eventually required additional endovascular procedures.
- 1 January 2009
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 56 (S 01) , V205
Serial CT-volumetry confirms shrinking of the false lumen throughout the descending aorta after antegrade stentgrafting for aortic dissection
Objectives: In aortic dissection (AD) involving the aortic arch, arch replacement and open antegrade stentgrafting of the descending aorta represents a novel hybrid approach for one stage exclusion of the false (FL) lumen throughout the thoracic aorta. The present study demonstrates its midterm results regarding thrombosis of the FL along the entire aorta using a hybrid stentgraft prosthesis. Methods: From 02.2005 to 09.2008 35 patients (22 acute AD, 13 chronic AD) underwent aortic arch replacement and antegrade stentgrafting of the descending aorta. CT-scans were performed postoperatively and during the follow-up. CT-serial volume measurements of the FL and TL were performed at the proximal (A) and distal (B) stentgraft level, at the level between stentgraft-end and proximal abdominal aorta (C) and at the distal abdominal aorta (D). Results: In-hospital mortality was 3% (1/35). One patient underwent conventional reoperation of the descending aorta postoperatively for a nonrecognized third patent FL. The aorta of the remaining 33 patients was evaluated during a period of 17±11 months (mean±SD). Levels A and B demonstrated a significant shrinking of the FL and a growth of the TL (p0.05). After three additional secondary endovascular interventions for distal endoleak, complete thrombosis of the FL in the peristentgraft space achieved in 97% (32/33). Conclusion: Open antegrade stentgrafting of the descending aorta with this hybrid prosthesis promoted significant thrombosis and shrinking of the FL down to the aortic stentgraft end. CT-scans are required for eventually required additional endovascular procedures.
- 26 May 2007
- Published by Springer Nature
- p. 79-91
Echokardiographische Abklärung des Patienten mit akutem Thoraxschmerz auf der Notfallstation
- 26 May 2007
- Published by Springer Nature
- p. 79-91
Echokardiographische Abklärung des Patienten mit akutem Thoraxschmerz auf der Notfallstation
- 1 December 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (6) , 843-852
Thoracic aorta endografts: Variations in practice among medical specialists
Endovascular stent-graft placement is emerging as a novel treatment option for patients with diseases of the descending thoracic aorta. However, currently no consensus guidelines exist to direct uniformity in stent-graft procedures as well as for pre- and postprocedural patient management, unlike that for the management of other cardiovascular disorder. Accordingly, the aim of the present survey was to assess variations in thoracic aortic stent-graft practice among different subspecialties in Germany. An interdisciplinary questionnaire survey was conducted among 206 departments of vascular surgery, radiology, cardiology, and cardiothoracic surgery in Germany that actively performed aortic stent-graft placement. Data on preoperative procedure planning, logistics, practical/technical issues of stent-graft placement, and postoperative patient management were evaluated using a standardized, self-administered questionnaire comprising 29 items. Responses were tabulated for analysis. Of a total of 206 questionnaires, 184 (89.3%) were returned with 71 (38.5%) centers reporting to have performed thoracic aortic stent-graft placement (total number of procedures 2,267) through 1997 and 2003. The average number of stent-graft procedures per year was 7.4 (25-75% percentile, 2.05-10.75) at participating sites, with 49% of the respondents reporting <5 procedures per year. Treatment of thoracic aortic aneurysms was the predominant indication for stent-graft placement, followed by type B-dissection. As anticipated, marked variability existed among the different medical specialties performing stent-graft procedures with respect to all aspects of the procedures including indication for treatment, choice of preoperative and intraoperative imaging modalities, technical equipment and perioperative management. The only consistent agreement was on the need for lifelong follow-up after stent-graft placement, with CT being the preferred imaging technique (90% of centers). The present survey documents an increasing adoption of endovascular stent-graft placement for patients with diseases of the descending thoracic aorta in Germany. Despite this, there is a lack of consensus among the different medical specialties performing stent-graft placement with respect to indications and technical execution of stent-grafting. Our data supports the need for consensus practice guidelines endorsed by medical professional societies for stent-graft procedure to standardize the growing number of thoracic stent graft procedures.
- 1 December 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (6) , 843-852
Thoracic aorta endografts: Variations in practice among medical specialists
Endovascular stent-graft placement is emerging as a novel treatment option for patients with diseases of the descending thoracic aorta. However, currently no consensus guidelines exist to direct uniformity in stent-graft procedures as well as for pre- and postprocedural patient management, unlike that for the management of other cardiovascular disorder. Accordingly, the aim of the present survey was to assess variations in thoracic aortic stent-graft practice among different subspecialties in Germany. An interdisciplinary questionnaire survey was conducted among 206 departments of vascular surgery, radiology, cardiology, and cardiothoracic surgery in Germany that actively performed aortic stent-graft placement. Data on preoperative procedure planning, logistics, practical/technical issues of stent-graft placement, and postoperative patient management were evaluated using a standardized, self-administered questionnaire comprising 29 items. Responses were tabulated for analysis. Of a total of 206 questionnaires, 184 (89.3%) were returned with 71 (38.5%) centers reporting to have performed thoracic aortic stent-graft placement (total number of procedures 2,267) through 1997 and 2003. The average number of stent-graft procedures per year was 7.4 (25-75% percentile, 2.05-10.75) at participating sites, with 49% of the respondents reporting <5 procedures per year. Treatment of thoracic aortic aneurysms was the predominant indication for stent-graft placement, followed by type B-dissection. As anticipated, marked variability existed among the different medical specialties performing stent-graft procedures with respect to all aspects of the procedures including indication for treatment, choice of preoperative and intraoperative imaging modalities, technical equipment and perioperative management. The only consistent agreement was on the need for lifelong follow-up after stent-graft placement, with CT being the preferred imaging technique (90% of centers). The present survey documents an increasing adoption of endovascular stent-graft placement for patients with diseases of the descending thoracic aorta in Germany. Despite this, there is a lack of consensus among the different medical specialties performing stent-graft placement with respect to indications and technical execution of stent-grafting. Our data supports the need for consensus practice guidelines endorsed by medical professional societies for stent-graft procedure to standardize the growing number of thoracic stent graft procedures.
- 1 August 2006
- Published by Elsevier in The American Journal of Cardiology
- Vol. 98 (4) , 458-463
Frequency and Outcomes of Acute Renal Failure Following Thoracic Aortic Stent-Graft Placement
- 1 August 2006
- Published by Elsevier in The American Journal of Cardiology
- Vol. 98 (4) , 458-463
Frequency and Outcomes of Acute Renal Failure Following Thoracic Aortic Stent-Graft Placement
- 1 March 2006
- Vol. 7 (3) , 264-71
Regadenoson (CV Therapeutics/Astellas).
CV Therapeutics and Astellas (formerly Fujisawa) are codeveloping the adenosine A2A receptor agonist regadenoson as a potential adjunctive intravenous pharmacological imaging agent in cardiac perfusion studies for the potential detection of coronary artery disease. Positive results from the first of two phase III clinical studies were reported in August 2005.
- 1 March 2006
- Vol. 7 (3) , 264-71
Regadenoson (CV Therapeutics/Astellas).
CV Therapeutics and Astellas (formerly Fujisawa) are codeveloping the adenosine A2A receptor agonist regadenoson as a potential adjunctive intravenous pharmacological imaging agent in cardiac perfusion studies for the potential detection of coronary artery disease. Positive results from the first of two phase III clinical studies were reported in August 2005.
- 1 February 2006
- Published by Elsevier in American Heart Journal
- Vol. 151 (2) , 530-536
Endovascular stent-graft treatment of penetrating aortic ulcer
- 1 February 2006
- Published by Elsevier in American Heart Journal
- Vol. 151 (2) , 530-536
Endovascular stent-graft treatment of penetrating aortic ulcer
- 1 February 2006
- Published by Springer Nature in Intensivmedizin und Notfallmedizin
- Vol. 43 (1) , 64-77
Echokardiographische Abklärung des Patienten mit akutem Thoraxschmerz auf der Notfallstation
- 1 February 2006
- Published by Springer Nature in Intensivmedizin und Notfallmedizin
- Vol. 43 (1) , 64-77
Echokardiographische Abklärung des Patienten mit akutem Thoraxschmerz auf der Notfallstation
- 1 February 2006
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (1) , 62-71
In Vitro Evaluation of Current Thoracic Aortic Stent-Grafts for Real-time MR-Guided Placement
Purpose: To systematically evaluate the magnetic resonance imaging (MRI) characteristics of current thoracic aortic stent-graft devices before, during, and after in vitro deployment as a step toward real-time MRI-guided stent placement. Methods: Six stent-graft devices used for thoracic aortic repair were examined in a dedicated phantom model using a 1.5-T MRI scanner. First, the delivery systems with the mounted stent-graft were examined using real-time fast imaging with steady-state precession (TrueFISP) with Cartesian and radial k-space filling. TrueFISP imaging was subsequently used for real-time monitoring of stent-graft expansion. The deployed stent-grafts were then examined in a water bath containing gadolinium (1:40) with high-resolution T1-weighted 3D fast low-angle shot (FLASH) sequences. The images were analyzed for artifacts, radiofrequency caging effects, and device visualization quality. Results: Three delivery systems with mounted stent-grafts did not contain ferromagnetic elements and were well visualized. Imaging with radial k-space filling showed fewer artifacts than Cartesian imaging. Movement of the delivery system and stent-graft expansion of these devices were successfully demonstrated at a rate of up to 6 frames per second. Evaluation of the expanded stent-grafts revealed only minor susceptibility artifacts without relevant signal attenuation in the stent-graft lumen for 5 nitinol-based stent-grafts. Only a stainless steel—based stent-graft was associated with severe artifacts, thwarting visualization of its lumen or surroundings. Conclusion: The present study shows that 3 nitinol-based thoracic stent-graft devices are potentially suited for real-time MRI-guided placement with respect to both the delivery system and the stent-graft itself. These observations provide the basis for the evaluation of MRI-guided stent-graft placement in vivo.
- 1 February 2006
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (1) , 62-71
In Vitro Evaluation of Current Thoracic Aortic Stent-Grafts for Real-time MR-Guided Placement
Purpose: To systematically evaluate the magnetic resonance imaging (MRI) characteristics of current thoracic aortic stent-graft devices before, during, and after in vitro deployment as a step toward real-time MRI-guided stent placement. Methods: Six stent-graft devices used for thoracic aortic repair were examined in a dedicated phantom model using a 1.5-T MRI scanner. First, the delivery systems with the mounted stent-graft were examined using real-time fast imaging with steady-state precession (TrueFISP) with Cartesian and radial k-space filling. TrueFISP imaging was subsequently used for real-time monitoring of stent-graft expansion. The deployed stent-grafts were then examined in a water bath containing gadolinium (1:40) with high-resolution T1-weighted 3D fast low-angle shot (FLASH) sequences. The images were analyzed for artifacts, radiofrequency caging effects, and device visualization quality. Results: Three delivery systems with mounted stent-grafts did not contain ferromagnetic elements and were well visualized. Imaging with radial k-space filling showed fewer artifacts than Cartesian imaging. Movement of the delivery system and stent-graft expansion of these devices were successfully demonstrated at a rate of up to 6 frames per second. Evaluation of the expanded stent-grafts revealed only minor susceptibility artifacts without relevant signal attenuation in the stent-graft lumen for 5 nitinol-based stent-grafts. Only a stainless steel—based stent-graft was associated with severe artifacts, thwarting visualization of its lumen or surroundings. Conclusion: The present study shows that 3 nitinol-based thoracic stent-graft devices are potentially suited for real-time MRI-guided placement with respect to both the delivery system and the stent-graft itself. These observations provide the basis for the evaluation of MRI-guided stent-graft placement in vivo.
- Open Access
- 23 January 2006
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 27 (5) , 613-620
Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection
Aims To evaluate the pre-clinical feasibility of real-time magnetic resonance imaging (rtMRI) to guide stent-graft placement for experimental aortic dissection (AD) and to alleviate disadvantages of ionising radiation and nephrotoxic contrast media. Endovascular stent-graft placement for thoracic aortic disease is usually performed under X-ray guidance. The feasibility of rtMRI-guided stent-graft placement is currently not known. Methods and results By using a catheter-based technique, dissections of the descending thoracic aorta were successfully created in eight domestic pigs. Subsequent implantation of commercially available, nitinol-based stent-grafts was performed entirely under rtMRI guidance. By pre-interventional MRI, the mean minimal true-lumen diameter was 0.9 (0.825–0.975) cm. rtMRI permitted not only the successful and safe device navigation within the true lumen from the iliac arteries to the thoracic aorta, but also the precise positioning and deployment of the stent-graft and safe withdrawal of the delivery catheter in seven of eight pigs. This was achieved without any other complications. After the stent-graft placement, MRI demonstrated complete obliteration of the false lumen, which was confirmed at autopsy. All stent-grafts were well expanded resulting in an increase in the size of the true-lumen diameter to 2.05 (1.925–2.1) cm (P=0.066 vs. baseline). Conclusion In experimental AD, rtMRI-guided endovascular stent-graft placement is feasible and safe and has the potential for mitigating radiation and contrast-related side effects. Additionally, it allows not only pre-interventional diagnosis and detailed anatomic diagnosis, but also permits immediate post-interventional, anatomical, and functional delineation of procedure success that may serve as a baseline for future comparison during follow-up.
- 23 January 2006
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 27 (5) , 613-620
Open AccessFeasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection
Aims To evaluate the pre-clinical feasibility of real-time magnetic resonance imaging (rtMRI) to guide stent-graft placement for experimental aortic dissection (AD) and to alleviate disadvantages of ionising radiation and nephrotoxic contrast media. Endovascular stent-graft placement for thoracic aortic disease is usually performed under X-ray guidance. The feasibility of rtMRI-guided stent-graft placement is currently not known. Methods and results By using a catheter-based technique, dissections of the descending thoracic aorta were successfully created in eight domestic pigs. Subsequent implantation of commercially available, nitinol-based stent-grafts was performed entirely under rtMRI guidance. By pre-interventional MRI, the mean minimal true-lumen diameter was 0.9 (0.825–0.975) cm. rtMRI permitted not only the successful and safe device navigation within the true lumen from the iliac arteries to the thoracic aorta, but also the precise positioning and deployment of the stent-graft and safe withdrawal of the delivery catheter in seven of eight pigs. This was achieved without any other complications. After the stent-graft placement, MRI demonstrated complete obliteration of the false lumen, which was confirmed at autopsy. All stent-grafts were well expanded resulting in an increase in the size of the true-lumen diameter to 2.05 (1.925–2.1) cm (P=0.066 vs. baseline). Conclusion In experimental AD, rtMRI-guided endovascular stent-graft placement is feasible and safe and has the potential for mitigating radiation and contrast-related side effects. Additionally, it allows not only pre-interventional diagnosis and detailed anatomic diagnosis, but also permits immediate post-interventional, anatomical, and functional delineation of procedure success that may serve as a baseline for future comparison during follow-up.