Suchi Yadav
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Suchi Yadav has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Aishik Acharya
Centre for Quantum Engineering, Research and Education (CQuERE), TCG CREST
2 shared publications Amitava Sen Gupta
Time and Frequency Section, Council of Scientific and Industrial Research-National Physical Laboratory, New Delhi, India
1 shared publication- AmitavaSen Gupta
National Physical Laboratory, New Delhi, India
1 shared publication - Ashish Agarwal
Time and Frequency Section, CSIR-National Physical Laboratory, New Delhi, India
1 shared publication Gupta As
1 shared publicationKavindra Pant
Time and Frequency Section, Council of Scientific and Industrial Research-National Physical Laboratory, New Delhi, India
1 shared publication
Latest Publications
- 29 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (7) , 2037-2042
NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results
National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.
- 29 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (7) , 2037-2042
NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results
National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.
- 1 January 2012
- Published by Medknow in IETE Journal of Research
- Vol. 58 (5) , 382
Versatile Linear and Digital Optocouplers to Reduce Noise and Ground Loop Errors in Measurements
The paper describes design details of low-cost, versatile, linear as well as digital optocoupler circuits used to reduce noise and ground loop errors in measurements. A detailed description of a linear optocoupler circuit for providing galvanic isolation between photodiode signal conditioner ground and the data logger ground is given. We also report use of two single-channel high-speed digital optocouplers to communicate through RS232 protocol isolating the ground of the devices in the detection region of the Cs fountain frequency standard being developed at NPL India. These isolators are versatile, affordable, and give very good results.
- 1 January 2012
- Published by Medknow in IETE Journal of Research
- Vol. 58 (5) , 382
Versatile Linear and Digital Optocouplers to Reduce Noise and Ground Loop Errors in Measurements
The paper describes design details of low-cost, versatile, linear as well as digital optocoupler circuits used to reduce noise and ground loop errors in measurements. A detailed description of a linear optocoupler circuit for providing galvanic isolation between photodiode signal conditioner ground and the data logger ground is given. We also report use of two single-channel high-speed digital optocouplers to communicate through RS232 protocol isolating the ground of the devices in the detection region of the Cs fountain frequency standard being developed at NPL India. These isolators are versatile, affordable, and give very good results.