İrFan Uckan
Research Subjects
İrFan Uckan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Beyza Cabir
VAN YÜZÜNCÜ YIL ÜNİVERSİTESİ, VAN MESLEK YÜKSEKOKULU
3 shared publications Ahmet Yakın
2 shared publications- Ahmet Yakın
Van Yuzuncu Yil Universitesi
2 shared publications Ali Abdullah Yousif
Department of Mechanical Engineering, Yuzuncu Yil University, Van, Turkey
1 shared publication- Elanur Baki Sezgin1 shared publication
Ertaç Hürdoğan
Department of Energy Systems Engineering, Osmaniye Korkut Ata University, Osmaniye, Turkey
1 shared publication
Latest Publications
- 20 July 2026
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 41 (2) , 1011-1024
İçten yanmalı bir motorda ftalosiyanin -benzin karışımı bir yakıt için ölü hâl sıcaklıklarının motor performansına etkisinin incelenmesi
Bu deneysel çalışmada, Ftalosiyanin katkılı benzin karışımlarının kıvılcım ateşlemeli (SI) bir içten yanmalı motorun termodinamik performansı üzerindeki etkileri, Ekserji analizi metodolojisi kullanılarak incelenmiştir. Çalışma, ekserji hesaplamalarının temel metodolojik hassasiyetini oluşturan Ölü Hâl Sıcaklığındaki (T0) değişimlerin, yeni formüle edilen Ftalosiyanin katkılı yakıt dizisi (B100, PG5, PG15, PG25) altındaki egzoz gazlarındaki ekserji değişim, motordaki ekserji kayıpları gibi motor performansı üzerindeki etkileri incelenmiştir. Deneyler 2200 dev/dak motor hızında gerçekleştirilmiş ve T0 değerlerinin 273 K'den 298 K'ye yükseltilmesinin sonuçları analiz edilmiştir. Elde edilen bulgular, %25 Ftalosiyanin içeren PG25 karışımının, incelenen tüm koşullarda en düşük ekserji kayıplarını ve en yüksek termodinamik optimizasyonu sağladığını ortaya koymuştur. PG25'in ekserji yıkım oranı, saf benzin B100'e göre 273 K'de yaklaşık %42 daha düşüktür (9.55 kW'a karşılık 13,57 kW), bu da katkı maddesinin yanma sürecindeki tersinmezlikleri etkili bir şekilde azalttığını göstermektedir. Metodolojik açıdan, T0'da ki artış, yanma ürünlerinin (N₂, O₂, H₂O) ekserjisini düşürürken CO ve CO2’nin ekserjilerinde artış meydana gelmiştir. Sonuç olarak, Ftalosiyanin katkısının, özellikle PG25 konsantrasyonunda, içten yanmalı motorun ekserjetik performansını saf benzine kıyasla önemli ölçüde iyileştirdiği ve sürdürülebilir motor optimizasyonları için umut verici bir potansiyel taşıdığı tespit edilmiştir.
- 20 July 2026
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 41 (2) , 1011-1024
İçten yanmalı bir motorda ftalosiyanin -benzin karışımı bir yakıt için ölü hâl sıcaklıklarının motor performansına etkisinin incelenmesi
Bu deneysel çalışmada, Ftalosiyanin katkılı benzin karışımlarının kıvılcım ateşlemeli (SI) bir içten yanmalı motorun termodinamik performansı üzerindeki etkileri, Ekserji analizi metodolojisi kullanılarak incelenmiştir. Çalışma, ekserji hesaplamalarının temel metodolojik hassasiyetini oluşturan Ölü Hâl Sıcaklığındaki (T0) değişimlerin, yeni formüle edilen Ftalosiyanin katkılı yakıt dizisi (B100, PG5, PG15, PG25) altındaki egzoz gazlarındaki ekserji değişim, motordaki ekserji kayıpları gibi motor performansı üzerindeki etkileri incelenmiştir. Deneyler 2200 dev/dak motor hızında gerçekleştirilmiş ve T0 değerlerinin 273 K'den 298 K'ye yükseltilmesinin sonuçları analiz edilmiştir. Elde edilen bulgular, %25 Ftalosiyanin içeren PG25 karışımının, incelenen tüm koşullarda en düşük ekserji kayıplarını ve en yüksek termodinamik optimizasyonu sağladığını ortaya koymuştur. PG25'in ekserji yıkım oranı, saf benzin B100'e göre 273 K'de yaklaşık %42 daha düşüktür (9.55 kW'a karşılık 13,57 kW), bu da katkı maddesinin yanma sürecindeki tersinmezlikleri etkili bir şekilde azalttığını göstermektedir. Metodolojik açıdan, T0'da ki artış, yanma ürünlerinin (N₂, O₂, H₂O) ekserjisini düşürürken CO ve CO2’nin ekserjilerinde artış meydana gelmiştir. Sonuç olarak, Ftalosiyanin katkısının, özellikle PG25 konsantrasyonunda, içten yanmalı motorun ekserjetik performansını saf benzine kıyasla önemli ölçüde iyileştirdiği ve sürdürülebilir motor optimizasyonları için umut verici bir potansiyel taşıdığı tespit edilmiştir.
- 24 June 2026
- Published by Mus Alparslan Universitesi Fen Bilimleri Dergisi in Muş Alparslan Üniversitesi Fen Bilimleri Dergisi
- No. Advanced O
Derin Öğrenme Tabanlı LSTM Modeli Kullanarak Çok Ufuklu Güneş Radyasyonu Tahmini
Bu çalışmada, günlük küresel güneş radyasyonunu tahmin etmek için çok ufuklu bir zaman serisi tahmin yaklaşımı geliştirilmiştir. Veri seti günlük frekansa göre hizalanmıştır ve eksik gözlemler, zamana dayalı enterpolasyon ve yılın gününe (DOY) dayalı mevsimsellik duyarlı istatistikleri birleştiren iki aşamalı bir atama stratejisi ile ele alınmıştır. Giriş özellikleri, gecikmeli değerler (1, 14, 30 gün) ve kayan pencere istatistikleri (ortalama, standart sapma, minimum ve maksimum) ile zenginleştirilmiştir. Çoklu çıktı başlıklarına sahip yığılmış derin LSTM mimarisi, tahmin modeli olarak kullanılmış ve Log-Cosh kayıp fonksiyonu kullanılarak eğitilmiştir. Model performansı, RMSE, MAE, nRMSE ve R² metrikleri kullanılarak değerlendirilmiştir. Sonuçlar, tahmin ufku arttıkça tahmin doğruluğunun önemli ölçüde iyileştiğini göstermektedir. 1 günlük ufuk için MAE değeri 1,166 iken, 14 günlük ve 30 günlük ufuklar için sırasıyla 0,645 ve 0,474'e düşmektedir. Benzer şekilde, R², 1 günlük tahminler için 0,642'den 30 günlük tahminler için 0,912'ye yükselmektedir.
- 24 June 2026
- Published by Mus Alparslan Universitesi Fen Bilimleri Dergisi in Muş Alparslan Üniversitesi Fen Bilimleri Dergisi
- No. Advanced O
Derin Öğrenme Tabanlı LSTM Modeli Kullanarak Çok Ufuklu Güneş Radyasyonu Tahmini
Bu çalışmada, günlük küresel güneş radyasyonunu tahmin etmek için çok ufuklu bir zaman serisi tahmin yaklaşımı geliştirilmiştir. Veri seti günlük frekansa göre hizalanmıştır ve eksik gözlemler, zamana dayalı enterpolasyon ve yılın gününe (DOY) dayalı mevsimsellik duyarlı istatistikleri birleştiren iki aşamalı bir atama stratejisi ile ele alınmıştır. Giriş özellikleri, gecikmeli değerler (1, 14, 30 gün) ve kayan pencere istatistikleri (ortalama, standart sapma, minimum ve maksimum) ile zenginleştirilmiştir. Çoklu çıktı başlıklarına sahip yığılmış derin LSTM mimarisi, tahmin modeli olarak kullanılmış ve Log-Cosh kayıp fonksiyonu kullanılarak eğitilmiştir. Model performansı, RMSE, MAE, nRMSE ve R² metrikleri kullanılarak değerlendirilmiştir. Sonuçlar, tahmin ufku arttıkça tahmin doğruluğunun önemli ölçüde iyileştiğini göstermektedir. 1 günlük ufuk için MAE değeri 1,166 iken, 14 günlük ve 30 günlük ufuklar için sırasıyla 0,645 ve 0,474'e düşmektedir. Benzer şekilde, R², 1 günlük tahminler için 0,642'den 30 günlük tahminler için 0,912'ye yükselmektedir.
- 1 September 2024
- Published by Igdir University in Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 14 (3) , 1253-1264
Ftalosiyaninin Benzinli Motor Performansı ve Emisyonlar Üzerine Etkilerinin Deneysel Olarak Araştırılması
Fosil yakıtların yanmasından kaynaklanan sera gazı emisyonlarının neden olduğu küresel ısınmanın ve bu yakıtların sınırlı doğasının farkına varılması, otomotiv mühendislerini alternatif enerji kaynaklarını ve araç tasarımlarını keşfetmeye yöneltmiştir. Hibrit ve elektrikli araçların (HEV'ler ve EV'ler) benimsenmesi artarken, içten yanmalı motorlu (İYM) araçlar yaygınlığını korumaktadır. İYM' lerle ilgili çevresel kaygıları gidermek için bilim insanları, fosil yakıtlara bağımlılığı daha da azaltmak için hidrojen yakıt hücreli elektrikli araçlar (FCEV'ler) ve bataryalı elektrikli araçlar (BEV'ler) gibi tamamen yeni araç tasarımlarına yönelik araştırmalara devam etmektedirler. Ayrıca günümüz araçlarında kullanılan motorların, motor verimliliğini artırmak ve emisyonları en aza indirmek için potansiyel çözümler olarak nano yakıtların ve yakıt katkı maddelerinin kullanımını araştırmaktadırlar. Benzin-ftalosiyanin karışımlarının içten yanmalı benzinli bir motordaki performans ve emisyonlarını değerlendirmek için deneysel bir araştırma yapılmıştır. FS7.5 (hacimsel olarak %92.5 benzin %7.5 ftalosiyanin), FS12.5 (hacimsel olarak %87.5 benzin %12.5 ftalosiyanin), FS17.5 (hacimsel olarak %82.5 benzin %17.5 ftalosiyanin) hazırlanmış ve daha sonra motorda değerlendirilmiştir. Deneysel çalışma sonuçlarına göre, benzin yakıtına kıyasla F17.5 karışım yakıtı kullanıldığında motor momenti %1.38 ve motor gücü %1.64 oranında artmıştır. Buna karşın, FS7.5 karışım yakıtı CO emisyonunda %55.89 oranında bir düşüşe yol açmıştır. FS17.5 karışım yakıtı ise egzoz gaz sıcaklığında %2.27 oranında bir azalma yaratırken, tüm karışım yakıtlarının HC, CO2 ve NOx emisyonlarında artış gözlenmiştir. Özgül yakıt tüketimleri ise FS7.5, FS12.5 ve FS17.5 karışım yakıtları için sırasıyla %5.51, %4.23 ve %2.83 oranlarında azalmıştır.
- 1 September 2024
- Published by Igdir University in Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 14 (3) , 1253-1264
Ftalosiyaninin Benzinli Motor Performansı ve Emisyonlar Üzerine Etkilerinin Deneysel Olarak Araştırılması
Fosil yakıtların yanmasından kaynaklanan sera gazı emisyonlarının neden olduğu küresel ısınmanın ve bu yakıtların sınırlı doğasının farkına varılması, otomotiv mühendislerini alternatif enerji kaynaklarını ve araç tasarımlarını keşfetmeye yöneltmiştir. Hibrit ve elektrikli araçların (HEV'ler ve EV'ler) benimsenmesi artarken, içten yanmalı motorlu (İYM) araçlar yaygınlığını korumaktadır. İYM' lerle ilgili çevresel kaygıları gidermek için bilim insanları, fosil yakıtlara bağımlılığı daha da azaltmak için hidrojen yakıt hücreli elektrikli araçlar (FCEV'ler) ve bataryalı elektrikli araçlar (BEV'ler) gibi tamamen yeni araç tasarımlarına yönelik araştırmalara devam etmektedirler. Ayrıca günümüz araçlarında kullanılan motorların, motor verimliliğini artırmak ve emisyonları en aza indirmek için potansiyel çözümler olarak nano yakıtların ve yakıt katkı maddelerinin kullanımını araştırmaktadırlar. Benzin-ftalosiyanin karışımlarının içten yanmalı benzinli bir motordaki performans ve emisyonlarını değerlendirmek için deneysel bir araştırma yapılmıştır. FS7.5 (hacimsel olarak %92.5 benzin %7.5 ftalosiyanin), FS12.5 (hacimsel olarak %87.5 benzin %12.5 ftalosiyanin), FS17.5 (hacimsel olarak %82.5 benzin %17.5 ftalosiyanin) hazırlanmış ve daha sonra motorda değerlendirilmiştir. Deneysel çalışma sonuçlarına göre, benzin yakıtına kıyasla F17.5 karışım yakıtı kullanıldığında motor momenti %1.38 ve motor gücü %1.64 oranında artmıştır. Buna karşın, FS7.5 karışım yakıtı CO emisyonunda %55.89 oranında bir düşüşe yol açmıştır. FS17.5 karışım yakıtı ise egzoz gaz sıcaklığında %2.27 oranında bir azalma yaratırken, tüm karışım yakıtlarının HC, CO2 ve NOx emisyonlarında artış gözlenmiştir. Özgül yakıt tüketimleri ise FS7.5, FS12.5 ve FS17.5 karışım yakıtları için sırasıyla %5.51, %4.23 ve %2.83 oranlarında azalmıştır.
- 24 May 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 71, 884-893
Investigation the performance of a new fuel produced from the phthalocyanine-gasoline mixture in an internal combustion engine
- 24 May 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 71, 884-893
Investigation the performance of a new fuel produced from the phthalocyanine-gasoline mixture in an internal combustion engine
- 17 November 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 49, 1257-1267
Second law analysis of an internal combustion engine for different fuels consisting of NaBH4, ethanol and methanol mixtures
- 17 November 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 49, 1257-1267
Second law analysis of an internal combustion engine for different fuels consisting of NaBH4, ethanol and methanol mixtures
- 30 September 2023
- Published by Erciyes Energy Association in ENERGY, ENVIRONMENT & STORAGE
- Vol. 3 (3) , 88-95
Numerical Analysis of The Multilayer Structures Melting with Different Hole Network with Phase Change Material
- 30 September 2023
- Published by Erciyes Energy Association in ENERGY, ENVIRONMENT & STORAGE
- Vol. 3 (3) , 88-95
Numerical Analysis of The Multilayer Structures Melting with Different Hole Network with Phase Change Material
- 24 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (25) , 37867-37881
Improving of global solar radiation forecast by comparing other meteorological parameter models with sunshine duration models
The aim of this study is to compare sunshine duration-based models and the other meteorological parameter-based models and to develop new forecasting models. The estimation and comparison of global solar radiation has been made by using twenty-four empirical models including three new models for different location named Arbil, Dohuk, and Sulaimania of Northern Iraq. The reason of using these different locations is to test the accuracy of the other meteorological parameter models by comparing the sunshine duration models for different region. Mostly common statistical error values are used to evaluate the performance of the estimation models and to identify the models that will give the closest results to the actual values. According to the results, it was seen that the models based on other meteorological parameters have better predictions than the models based on the sunshine duration. While the R2 value of the best models depending on the sunshine duration ranged from 0.97 to 0.99, the R2 values of the best models of other meteorological parameters are above 0.99. Furthermore, it is observed that the new proposed models provide better estimates of global solar radiation at different locations than all models used in this study.
- 24 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (25) , 37867-37881
Improving of global solar radiation forecast by comparing other meteorological parameter models with sunshine duration models
The aim of this study is to compare sunshine duration-based models and the other meteorological parameter-based models and to develop new forecasting models. The estimation and comparison of global solar radiation has been made by using twenty-four empirical models including three new models for different location named Arbil, Dohuk, and Sulaimania of Northern Iraq. The reason of using these different locations is to test the accuracy of the other meteorological parameter models by comparing the sunshine duration models for different region. Mostly common statistical error values are used to evaluate the performance of the estimation models and to identify the models that will give the closest results to the actual values. According to the results, it was seen that the models based on other meteorological parameters have better predictions than the models based on the sunshine duration. While the R2 value of the best models depending on the sunshine duration ranged from 0.97 to 0.99, the R2 values of the best models of other meteorological parameters are above 0.99. Furthermore, it is observed that the new proposed models provide better estimates of global solar radiation at different locations than all models used in this study.
- 29 May 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 43 (7) , 875-892
Investigation of the effect of various solar collector types on a solar absorption cooling system
A single-effect absorption cooling system was planned and simulated appropriate to a hot and dry climate, and optimization was made accordingly in the present study. TRNSYS software is a very comprehensive program that includes much equipment in its subprograms. For this reason, solar collectors, cooling tower, auxiliary heater, and storage tank used in this study are modeled in this software. The designed cooling system is considered as a market that has a cooling need of 35 kW and has a space of 275 m2. It was examined in this study that how the performance of a single-effect LiBr-H2O absorption cooling system was affected by three different kinds of solar collectors such as flat plate collector (FPC), Non-tracking concentrating parabolic solar collector (XCPC), and evacuated tube collector (ETC). It was also evaluated that how different criteria such as solar fraction, hot water tank temperature and tank volume, collector area, and collector type affected system performance. In the study, it was noticed that collector area had an important effect on the collector efficiency, heater power and hot water tank temperature. It was found that minimum collector area for XCPC, ETC and FPC collectors were approximately 100 m2, 125 m2 and 150 m2, respectively. Also, depending on the change in the tank volume, significant changes occurred in the tank temperature. The hot water tank volume was raised from 0.5 m3 to 6 m3 for XCPC, ETC and FPC collectors, the upper hot water tank temperature decreased about 15°C, 11°C and 8°C, respectively. In conclusion, it has been observed that XCPC collectors perform better to improve system performance compared to other collectors used.
- 29 May 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 43 (7) , 875-892
Investigation of the effect of various solar collector types on a solar absorption cooling system
A single-effect absorption cooling system was planned and simulated appropriate to a hot and dry climate, and optimization was made accordingly in the present study. TRNSYS software is a very comprehensive program that includes much equipment in its subprograms. For this reason, solar collectors, cooling tower, auxiliary heater, and storage tank used in this study are modeled in this software. The designed cooling system is considered as a market that has a cooling need of 35 kW and has a space of 275 m2. It was examined in this study that how the performance of a single-effect LiBr-H2O absorption cooling system was affected by three different kinds of solar collectors such as flat plate collector (FPC), Non-tracking concentrating parabolic solar collector (XCPC), and evacuated tube collector (ETC). It was also evaluated that how different criteria such as solar fraction, hot water tank temperature and tank volume, collector area, and collector type affected system performance. In the study, it was noticed that collector area had an important effect on the collector efficiency, heater power and hot water tank temperature. It was found that minimum collector area for XCPC, ETC and FPC collectors were approximately 100 m2, 125 m2 and 150 m2, respectively. Also, depending on the change in the tank volume, significant changes occurred in the tank temperature. The hot water tank volume was raised from 0.5 m3 to 6 m3 for XCPC, ETC and FPC collectors, the upper hot water tank temperature decreased about 15°C, 11°C and 8°C, respectively. In conclusion, it has been observed that XCPC collectors perform better to improve system performance compared to other collectors used.
- 26 March 2018
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 15 (5) , 358-370
Estimation and comparison of various global solar radiation models on horizontal surface in a hot and dry region
In this study, 54 empirical models including 22 new models were used to estimate the global solar radiation on horizontal surface. The data were collected in Dohuk cities in the northern Iraq. The evaluated models are based on sunshine duration, air temperature, cloud cover, and other meteorological parameters. In the investigated region, the statistical error indicators value for all empirical models of R, R2, mean absolute bias error, root mean square error, mean absolute percentage error, Nash–Sutcliffe equation, and t-test value were low and within an acceptable range. The results of Model 49 based on the other meteorological parameters which is newly developed model with equation of had the most appropriate result with a value of R2 (0.9942) in the 54 empirical models. Besides, 22 new equation models are produced based on sunshine hours, air temperature, and other meteorological parameters. The best accuracy among the new equation was observed in Model 49. Furthermore, the Models 34, 12, and 25 based on cloud cover, sunshine hour, and air temperature in terms of data accuracy were ranked, respectively.
- 26 March 2018
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 15 (5) , 358-370
Estimation and comparison of various global solar radiation models on horizontal surface in a hot and dry region
In this study, 54 empirical models including 22 new models were used to estimate the global solar radiation on horizontal surface. The data were collected in Dohuk cities in the northern Iraq. The evaluated models are based on sunshine duration, air temperature, cloud cover, and other meteorological parameters. In the investigated region, the statistical error indicators value for all empirical models of R, R2, mean absolute bias error, root mean square error, mean absolute percentage error, Nash–Sutcliffe equation, and t-test value were low and within an acceptable range. The results of Model 49 based on the other meteorological parameters which is newly developed model with equation of had the most appropriate result with a value of R2 (0.9942) in the 54 empirical models. Besides, 22 new equation models are produced based on sunshine hours, air temperature, and other meteorological parameters. The best accuracy among the new equation was observed in Model 49. Furthermore, the Models 34, 12, and 25 based on cloud cover, sunshine hour, and air temperature in terms of data accuracy were ranked, respectively.
- 16 April 2014
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 12 (11) , 1159-1168
Development of an Artificial Neural Network Model for the Prediction of the Performance of a Silica-gel Desiccant Wheel
This work presents mathematical equations derived from Artificial Neural Networks (ANNs) for the estimation of dry bulb temperature and specific humidity at the outlet of a desiccant wheel to predict useful data for designers and engineers. The neural network model comprises five inputs and two output neurons that define the outlet conditions (dry bulb temperature and specific humidity) of a desiccant wheel. The results obtained by the ANN model are compared with the actual data by using input variables. The results show that the mean absolute percentage errors for dry bulb temperature and specific humidity are found to be 0.80% and 1.56% respectively; and the correlation coefficient (R) values obtained are approximately 0.986 for both output variables. The root mean square errors, which is another significant point in this study, are found to be 0.54% and 0.18% for dry bulb temperature and specific humidity respectively.
- 16 April 2014
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 12 (11) , 1159-1168
Development of an Artificial Neural Network Model for the Prediction of the Performance of a Silica-gel Desiccant Wheel
This work presents mathematical equations derived from Artificial Neural Networks (ANNs) for the estimation of dry bulb temperature and specific humidity at the outlet of a desiccant wheel to predict useful data for designers and engineers. The neural network model comprises five inputs and two output neurons that define the outlet conditions (dry bulb temperature and specific humidity) of a desiccant wheel. The results obtained by the ANN model are compared with the actual data by using input variables. The results show that the mean absolute percentage errors for dry bulb temperature and specific humidity are found to be 0.80% and 1.56% respectively; and the correlation coefficient (R) values obtained are approximately 0.986 for both output variables. The root mean square errors, which is another significant point in this study, are found to be 0.54% and 0.18% for dry bulb temperature and specific humidity respectively.