Yannick Nochez
Research Subjects
Yannick Nochez has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Pierre-Jean Pisella
7 shared publicationsPj Pisella
Tours
7 shared publicationsSamuel Majzoub
4 shared publicationsP.-J. Pisella
3 shared publicationsA Cardon
Université François Rabelais, Tours
2 shared publicationsA Favard
CHU Bretonneau, Tours
2 shared publications
Latest Publications
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90
Customized intraocular lenses enhance binocular depth-of-focus and optimize stereoscopic vision
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90
Customized intraocular lenses enhance binocular depth-of-focus and optimize stereoscopic vision
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (s249)
Axonal loss in multiple sclerosis: a morphological and functional analysis of retinal nerve fibbers
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (s249)
Axonal loss in multiple sclerosis: a morphological and functional analysis of retinal nerve fibbers
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (s249)
Spherical aberration and binocularity
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (s249)
Spherical aberration and binocularity
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (s249)
Tear film break‐up time evaluation by real‐time wavefront aberrometry in normal subjects
- 6 August 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (s249)
Tear film break‐up time evaluation by real‐time wavefront aberrometry in normal subjects
- 20 April 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (8) , e663-e665
Predictive factors for visual outcome after resection of spheno‐orbital meningiomas: a long‐term review
- 20 April 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (8) , e663-e665
Predictive factors for visual outcome after resection of spheno‐orbital meningiomas: a long‐term review
- 1 April 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (4) , 633-640
Effect of interaction of macroaberrations and scattered light on objective quality of vision in pseudophakic eyes with aspheric monofocal intraocular lenses
PURPOSE: To assess the impact of wavefront ocular aberrations on objective vision quality and depth of focus in pseudophakic patients. SETTING: University Hospital Bretonneau of Tours, Francois Rabelais Medicine Faculty of Tours, France. DESIGN: Cohort study. METHODS: Consecutive eyes having implantation of an aspheric monofocal intraocular lens (IOL) (Acri.Smart) were studied. Aberrometry measurements were performed under mesopic conditions with a 6.0 mm pupil using a Wavescan aberrometer. Objective evaluation of optical vision quality was performed using the Optical Quality Analysis System II. The 3 measurements were the modulation transfer function values (MTF cutoff); objective depth of focus, which was computed as the focus range at which Strehl ratio did not fall below 50% of the maximum; and the objective scatter index. RESULTS: Fifty-four eyes (30 patients) were enrolled. Six months postoperatively, MTF cutoff values were increased with decreasing total ocular spherical aberration, ocular trefoil, and 2nd-order astigmatism (P<.05). Objective depth of focus was positively correlated with 2nd-order astigmatism (r2 = 0.171, P<.001) and total spherical aberration (r2 = 0.091, P=.028). Objective scatter was more beneficial for depth of focus, with a significantly positive correlation with this parameter (r2 = 0.28, P=.002), than compromising of optical quality (no significant correlation with MTF measurements in same multiple regression analysis). CONCLUSION: Three ocular aberrations (2nd-order astigmatism, trefoil, spherical aberration) seemed to interact with objective contrast sensitivity and depth of focus, whereas residual spherical aberration exerted opposite effects on image quality in individual patients. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
- 1 April 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (4) , 633-640
Effect of interaction of macroaberrations and scattered light on objective quality of vision in pseudophakic eyes with aspheric monofocal intraocular lenses
PURPOSE: To assess the impact of wavefront ocular aberrations on objective vision quality and depth of focus in pseudophakic patients. SETTING: University Hospital Bretonneau of Tours, Francois Rabelais Medicine Faculty of Tours, France. DESIGN: Cohort study. METHODS: Consecutive eyes having implantation of an aspheric monofocal intraocular lens (IOL) (Acri.Smart) were studied. Aberrometry measurements were performed under mesopic conditions with a 6.0 mm pupil using a Wavescan aberrometer. Objective evaluation of optical vision quality was performed using the Optical Quality Analysis System II. The 3 measurements were the modulation transfer function values (MTF cutoff); objective depth of focus, which was computed as the focus range at which Strehl ratio did not fall below 50% of the maximum; and the objective scatter index. RESULTS: Fifty-four eyes (30 patients) were enrolled. Six months postoperatively, MTF cutoff values were increased with decreasing total ocular spherical aberration, ocular trefoil, and 2nd-order astigmatism (P<.05). Objective depth of focus was positively correlated with 2nd-order astigmatism (r2 = 0.171, P<.001) and total spherical aberration (r2 = 0.091, P=.028). Objective scatter was more beneficial for depth of focus, with a significantly positive correlation with this parameter (r2 = 0.28, P=.002), than compromising of optical quality (no significant correlation with MTF measurements in same multiple regression analysis). CONCLUSION: Three ocular aberrations (2nd-order astigmatism, trefoil, spherical aberration) seemed to interact with objective contrast sensitivity and depth of focus, whereas residual spherical aberration exerted opposite effects on image quality in individual patients. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
- 1 December 2011
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 34 (10) , 715-722
Influence des aberrations optiques d’ordre élevé sur la capacité accommodative des patients présentant une presbytie débutante
- 1 December 2011
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 34 (10) , 715-722
Influence des aberrations optiques d’ordre élevé sur la capacité accommodative des patients présentant une presbytie débutante
- 1 October 2011
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 34 (8) , 592-593
Cataracte capsulaire antérieure de Thomson
- 1 October 2011
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 34 (8) , 592-593
Cataracte capsulaire antérieure de Thomson
- 1 June 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (6) , 1076-1081
Effect of residual ocular spherical aberration on objective and subjective quality of vision in pseudophakic eyes
To determine the level of residual spherical aberration that gives the best objective and subjective quality of image after cataract surgery with intraocular lens (IOL) implantation. Department of Ophthalmology, CHU Bretonneau, Tours, France. Cohort study. Six months after microincision (1.8 mm) cataract surgery with aspheric IOL implantation, total aberrations were computed using a Wavescan aberrometer. The modulation transfer function (MTF), Strehl ratio, and objective index of scattering were measured using the Objective Quality Analysis System. Objective depth of focus was computed as the focus range at which the Strehl ratio did not fall below 50% of maximum. Subjective depth of focus was calculated as the difference between the vergence of the punctum remotum and that of the punctum proximum. Thirty patients (54 eyes) were evaluated. The MTF cutoff values were higher with decreasing total ocular spherical aberration (r = 0.56; P < .05). Objective and subjective depth of focus were positively correlated with total spherical aberration (r = 0.26 and r = 0.46, respectively; P < .05). A final spherical aberration of zero obtained by compensation of IOL asphericity gave the greatest improvement in objective quality of vision and better MTF contrast. However, a final target ocular spherical aberration between 0.07 μm and 0.10 μm should be considered to be the best compromise between subjective depth of focus and objective contrast sensitivity. No author has a financial or proprietary interest in any material or method mentioned.
- 1 June 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (6) , 1076-1081
Effect of residual ocular spherical aberration on objective and subjective quality of vision in pseudophakic eyes
To determine the level of residual spherical aberration that gives the best objective and subjective quality of image after cataract surgery with intraocular lens (IOL) implantation. Department of Ophthalmology, CHU Bretonneau, Tours, France. Cohort study. Six months after microincision (1.8 mm) cataract surgery with aspheric IOL implantation, total aberrations were computed using a Wavescan aberrometer. The modulation transfer function (MTF), Strehl ratio, and objective index of scattering were measured using the Objective Quality Analysis System. Objective depth of focus was computed as the focus range at which the Strehl ratio did not fall below 50% of maximum. Subjective depth of focus was calculated as the difference between the vergence of the punctum remotum and that of the punctum proximum. Thirty patients (54 eyes) were evaluated. The MTF cutoff values were higher with decreasing total ocular spherical aberration (r = 0.56; P < .05). Objective and subjective depth of focus were positively correlated with total spherical aberration (r = 0.26 and r = 0.46, respectively; P < .05). A final spherical aberration of zero obtained by compensation of IOL asphericity gave the greatest improvement in objective quality of vision and better MTF contrast. However, a final target ocular spherical aberration between 0.07 μm and 0.10 μm should be considered to be the best compromise between subjective depth of focus and objective contrast sensitivity. No author has a financial or proprietary interest in any material or method mentioned.
- 1 May 2010
- Published by BMJ in British Journal of Ophthalmology
- Vol. 94 (5) , 661-663
Corneal aberration integrity after microincision cataract surgery: prerequisite condition for prediction of total ocular aberrations
- 1 May 2010
- Published by BMJ in British Journal of Ophthalmology
- Vol. 94 (5) , 661-663
Corneal aberration integrity after microincision cataract surgery: prerequisite condition for prediction of total ocular aberrations