JAJoseph G. Allen

Joseph G. Allen

*This is an algorithmically generated author record based on publicly available information.

Joseph G. Allen has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Predicted indoor radon concentrations from a Monte Carlo simulation of 1 000 000 granite countertop purchases

    by J G Allen, L M Zwack, D L MacIntosh, T Minegishi, J H Stewart, J F McCarthy

    Previous research examining radon exposure from granite countertops relied on using a limited number of exposure scenarios. We expanded upon this analysis and determined the probability that installing a granite countertop in a residential home would lead to a meaningful radon exposure by performing a Monte Carlo simulation to obtain a distribution of potential indoor radon concentrations attributable to granite. The Monte Carlo analysis included estimates of the probability that a particular type of granite would be purchased, the radon flux associated with that type, the size of the countertop purchased, the volume of the home where it would be installed and the air exchange rate of that home. One million countertop purchases were simulated and 99.99% of the resulting radon concentrations were lower than the average outdoor radon concentrations in the US (14.8 Bq m(-3); 0.4 pCi l(-1)). The median predicted indoor concentration from granite countertops was 0.06 Bq m(-3) (1.59 × 10(-3) pCi l(-1)), which is over 2000 times lower than the US Environmental Protection Agency's action level for indoor radon (148 Bq m(-3); 4 pCi l(-1)). The results show that there is a low probability of a granite countertop causing elevated levels of radon in a home.


  • Assessing risk of health care–acquired Legionnaires' disease from environmental sampling: The limits of using a strict percent positivity approach

    by Joseph G. Allen, Theodore A. Myatt, David L. MacIntosh, Jerry F. Ludwig, Taeko Minegishi, James H. Stewart, Bryan F. Connors, Michael P. Grant, John F. McCarthy


  • Open Access

    Mitigation of building-related polychlorinated biphenyls in indoor air of a school

    by David L MacIntosh, Taeko Minegishi, Matthew A Fragala, Joseph G Allen, Kevin M Coghlan, James H Stewart, John F McCarthy

    Sealants and other building materials sold in the U.S. from 1958 - 1971 were commonly manufactured with polychlorinated biphenyls (PCBs) at percent quantities by weight. Volatilization of PCBs from construction materials has been reported to produce PCB levels in indoor air that exceed health protective guideline values. The discovery of PCBs in indoor air of schools can produce numerous complications including disruption of normal operations and potential risks to health. Understanding the dynamics of building-related PCBs in indoor air is needed to identify effective strategies for managing potential exposures and risks. This paper reports on the efficacy of selected engineering controls implemented to mitigate concentrations of PCBs in indoor air.


  • Open Access

    Modeling the airborne survival of influenza virus in a residential setting: the impacts of home humidification

    by Theodore A Myatt, Matthew H Kaufman, Joseph G Allen, David L MacIntosh, M Patricia Fabian, James J McDevitt

    Laboratory research studies indicate that aerosolized influenza viruses survive for longer periods at low relative humidity (RH) conditions. Further analysis has shown that absolute humidity (AH) may be an improved predictor of virus survival in the environment. Maintaining airborne moisture levels that reduce survival of the virus in the air and on surfaces could be another tool for managing public health risks of influenza.


  • Assessing exposure to granite countertops—part 2: Radon

    by Joseph G Allen, Taeko Minegishi, Theodore A Myatt, James H Stewart, John F Mccarthy, David L Macintosh

    Radon gas (222Rn) is a natural constituent of the environment and a risk factor for lung cancer that we are exposed to as a result of radioactive decay of radium (226Ra) in stone and soil. Granite countertops, in particular, have received recent media attention regarding their potential to emit radon. Radon flux was measured on 39 full slabs of granite from 27 different varieties to evaluate the potential for exposure and examine determinants of radon flux. Flux was measured at up to six pre-selected locations on each slab and also at areas identified as potentially enriched after a full-slab scan using a Geiger–Muller detector. Predicted indoor radon concentrations were estimated from the measured radon flux using the CONTAM indoor air quality model. Whole-slab average emissions ranged from less than limit of detection to 79.4 Bq/m2/h (median 3.9 Bq/m2/h), similar to the range reported in the literature for convenience samples of small granite pieces. Modeled indoor radon concentrations were less than the average outdoor radon concentration (14.8 Bq/m3; 0.4 pCi/l) and average indoor radon concentrations (48 Bq/m3; 1.3 pCi/l) found in the United States. Significant within-slab variability was observed for stones on the higher end of whole slab radon emissions, underscoring the limitations of drawing conclusions from discrete samples.


  • Critical factors in assessing exposure to PBDEs via house dust

    by Joseph G. Allen, Michael D. McClean, Heather M. Stapleton, Thomas F. Webster


  • Open Access

    Control of asthma triggers in indoor air with air cleaners: a modeling analysis

    by Theodore A Myatt, Taeko Minegishi, Joseph G Allen, David L MacIntosh

    Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated.


  • Linking PBDEs in House Dust to Consumer Products using X-ray Fluorescence

    by Joseph G. Allen, Michael D. McClean, Heather M. Stapleton, Thomas F. Webster

    The indoor environment is an important source of exposure to polybrominated diphenyl ethers (PBDEs), a class of fire retardants used in many household products. Previous attempts to link PBDE concentrations in house dust to consumer products have been hampered by the inability to determine the presence of PBDEs in otherwise similar products. We used a portable X-ray fluorescence (XRF) analyzer to nondestructively quantify bromine concentrations in consumer goods. In the validation phase, XRF-measured bromine was highly correlated with GC/MS-measured bromine for furniture foam and plastic from electronics (n = 29, r = 0.93, p < 0.0001). In the field study phase, the XRF-measured bromine in room furniture was associated with pentaBDE concentrations in room dust in the bedroom (r = 0.68, p = 0.001) and main living area (r = 0.51, p = 0.02). We also found an association between XRF-measured bromine levels in electronics and decaBDE levels in dust, largely driven by the high levels in televisions (r = 0.64, p = 0.003 for bedrooms). For the main living area, predicting decaBDE in dust improved when we included an interaction effect between the bromine content of televisions and the number of persons in the house (p < 0.005), a potential surrogate for television usage.