Satoshi Ninomiya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Satoshi Ninomiya has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Kenzo Hiraoka
Clean Energy Research Center University of Yamanashi Kofu Japan
19 shared publications Kenzo Hiraoka
Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi, 400-8511, Japan
9 shared publicationsLee Chuin Chen
University of Yamanashi
9 shared publications- Lee Chuin Chen
Faculty of Engineering, University of Yamanashi
9 shared publications - Takaaki Aoki
SENTAN, Japan Science and Technology Agency (JST)
7 shared publications - Toshio Seki
Quantum Science and Engineering Center, Kyoto University 2 , Gokasho, Uji, Kyoto 611-0011
7 shared publications
Latest Publications
- Open Access
- 15 October 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (39) , 8888-8896
Application of robotic sheath-flow probe electrospray ionization (sfPESI) to wet and dry agricultural products and insecticides
A lock-in amplifier-equipped touch sensor provides rapid and automated analysis of wet and dry agricultural products using sheath-flow probe electrospray ionization mass spectrometry.
- 15 October 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (39) , 8888-8896
Open AccessApplication of robotic sheath-flow probe electrospray ionization (sfPESI) to wet and dry agricultural products and insecticides
A lock-in amplifier-equipped touch sensor provides rapid and automated analysis of wet and dry agricultural products using sheath-flow probe electrospray ionization mass spectrometry.
- Open Access
- 6 December 2025
- Published by The Mass Spectrometry Society of Japan in Mass Spectrometry
- Vol. 14 (1) , A0179
Click-and-Analyze: Automated Pinpoint Ambient Mass Spectrometry with Sheath-Flow Probe Electrospray Ionization
We report a robotic sheath-flow probe electrospray ionization mass spectrometry (PESI-MS) system with a new probe design and automated positioning capabilities for pinpoint ambient mass spectrometry. The system integrates a 3-axis Cartesian robot with two cameras: a fixed global camera for coarse positioning and a movable local camera for fine alignment, enabling users to designate sampling spots by mouse-clicking on live images displayed on the graphical user interface. A microcontroller is used for voltage control, current monitoring, and the detection of probe-sample contact. Sampling, transfer, ionization, and cleaning are fully automated under computer control, and the sheath liquid is supplied by a programmable syringe pump to maintain a stable flow rate. The system successfully analyzed aqueous standards, beverages, and water-rich soft materials such as jelly and fruit slices, yielding stable ion signals with negligible carry-over between measurements.
- 6 December 2025
- Published by The Mass Spectrometry Society of Japan in Mass Spectrometry
- Vol. 14 (1) , A0179
Open AccessClick-and-Analyze: Automated Pinpoint Ambient Mass Spectrometry with Sheath-Flow Probe Electrospray Ionization
We report a robotic sheath-flow probe electrospray ionization mass spectrometry (PESI-MS) system with a new probe design and automated positioning capabilities for pinpoint ambient mass spectrometry. The system integrates a 3-axis Cartesian robot with two cameras: a fixed global camera for coarse positioning and a movable local camera for fine alignment, enabling users to designate sampling spots by mouse-clicking on live images displayed on the graphical user interface. A microcontroller is used for voltage control, current monitoring, and the detection of probe-sample contact. Sampling, transfer, ionization, and cleaning are fully automated under computer control, and the sheath liquid is supplied by a programmable syringe pump to maintain a stable flow rate. The system successfully analyzed aqueous standards, beverages, and water-rich soft materials such as jelly and fruit slices, yielding stable ion signals with negligible carry-over between measurements.
- 2 December 2025
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 40 (4) , e70003
Alkali Halides as Matrices for the Detection of Saccharides and PEG600 by Electrospray Droplet Impact/Secondary Ion Mass Spectrometry (EDI/SIMS)
Rationale: Saccharides are often analyzed by matrix‐assisted laser desorption/ionization mass spectrometry and electrospray ionization mass spectrometry. In this study, electrospray droplet impact/secondary ion mass spectrometry (EDI/SIMS) was applied to the analysis of saccharides and PEG600 with and without using matrices of alkali halides AX (A: alkali, X: halide). Methods: 1 μL aqueous solutions of 2 × 10 −3 mol·L −1 analytes M (glucose, sucrose, raffinose or PEG 600) and 2 × 10 −3 mol·L −1 alkali halide mixture of [Li, Na, K, Rb, Cs]X for X = F, Cl, Br, and I were deposited on the substrate. After drying in vacuum, EDI mass spectra of analytes were measured with and without the AX matrices. The charged water droplets were generated by electrospraying 10 −2 mol⋅L −1 aqueous solution of CF 3 COOH. Results: By the addition of four sets of AX matrices, relative intensities of [M + H] + and [M + A] + in the positive mode, and [M − H] − , [M + CF 3 COO] − , and [M + X] − in the negative mode showed characteristic behavior depending on the combination of A and X. The matrices which gave the strongest ion signals were LiI for [M + Li] + , and LiF for [saccharide + CF 3 COO] − and [saccharide − H] − . CsF gave a relatively strong ion signal for [PEG600 + Cs] + . Conclusion: The high detection sensitivities obtained by LiI for [M + Li] + may be due to the largest bond energies of Li + ⋅⋅⋅M and the weak lattice energy of LiI. LiF gave good results for the detection of [saccharide − H] − and [saccharide + CF 3 COO] − due to the segregation of analytes on the LiF matrix.
- 2 December 2025
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 40 (4) , e70003
Alkali Halides as Matrices for the Detection of Saccharides and PEG600 by Electrospray Droplet Impact/Secondary Ion Mass Spectrometry (EDI/SIMS)
Rationale: Saccharides are often analyzed by matrix‐assisted laser desorption/ionization mass spectrometry and electrospray ionization mass spectrometry. In this study, electrospray droplet impact/secondary ion mass spectrometry (EDI/SIMS) was applied to the analysis of saccharides and PEG600 with and without using matrices of alkali halides AX (A: alkali, X: halide). Methods: 1 μL aqueous solutions of 2 × 10 −3 mol·L −1 analytes M (glucose, sucrose, raffinose or PEG 600) and 2 × 10 −3 mol·L −1 alkali halide mixture of [Li, Na, K, Rb, Cs]X for X = F, Cl, Br, and I were deposited on the substrate. After drying in vacuum, EDI mass spectra of analytes were measured with and without the AX matrices. The charged water droplets were generated by electrospraying 10 −2 mol⋅L −1 aqueous solution of CF 3 COOH. Results: By the addition of four sets of AX matrices, relative intensities of [M + H] + and [M + A] + in the positive mode, and [M − H] − , [M + CF 3 COO] − , and [M + X] − in the negative mode showed characteristic behavior depending on the combination of A and X. The matrices which gave the strongest ion signals were LiI for [M + Li] + , and LiF for [saccharide + CF 3 COO] − and [saccharide − H] − . CsF gave a relatively strong ion signal for [PEG600 + Cs] + . Conclusion: The high detection sensitivities obtained by LiI for [M + Li] + may be due to the largest bond energies of Li + ⋅⋅⋅M and the weak lattice energy of LiI. LiF gave good results for the detection of [saccharide − H] − and [saccharide + CF 3 COO] − due to the segregation of analytes on the LiF matrix.
- 9 October 2025
- Published by Wiley in Surface and Interface Analysis
- Vol. 57 (12) , 953-960
Oxidation of Metallic Aluminum Studied by Electrospray Droplet Impact/X‐Ray Photoelectron Spectroscopy (EDI/XPS)
The oxidation processes of metallic aluminum (Al) are complicated due to the formation of intermediate oxide products. In this work, detailed X‐ray photoelectron spectroscopy analysis of the metallic Al and Al 2 O 3 irradiated by water droplet beams produced by electrospray of aqueous solutions was performed. When metallic Al was left in vacuum with a vapor pressure of P (H 2 O) = 7.4 × 10 −6 Pa, Al 2 O 3 was formed as a major product. On the other hand, by the water droplet beam irradiation on metallic Al, the formation of pseudoboehmite AlO(OH) along with the Al 2 O 3 occurred. Although it was confirmed that Al 2 O 3 could be formed on the Al surface irradiated by the water droplet beams, the simultaneous formation of AlO(OH) and Al 2 O 3 makes it difficult to apply water droplet beam etching to the interface analysis of Al 2 O 3 /Al. It is concluded that the oxidation mechanism of metallic Al irradiated by the water droplet beams differs from that formed when left in vacuum.
- 9 October 2025
- Published by Wiley in Surface and Interface Analysis
- Vol. 57 (12) , 953-960
Oxidation of Metallic Aluminum Studied by Electrospray Droplet Impact/X‐Ray Photoelectron Spectroscopy (EDI/XPS)
The oxidation processes of metallic aluminum (Al) are complicated due to the formation of intermediate oxide products. In this work, detailed X‐ray photoelectron spectroscopy analysis of the metallic Al and Al 2 O 3 irradiated by water droplet beams produced by electrospray of aqueous solutions was performed. When metallic Al was left in vacuum with a vapor pressure of P (H 2 O) = 7.4 × 10 −6 Pa, Al 2 O 3 was formed as a major product. On the other hand, by the water droplet beam irradiation on metallic Al, the formation of pseudoboehmite AlO(OH) along with the Al 2 O 3 occurred. Although it was confirmed that Al 2 O 3 could be formed on the Al surface irradiated by the water droplet beams, the simultaneous formation of AlO(OH) and Al 2 O 3 makes it difficult to apply water droplet beam etching to the interface analysis of Al 2 O 3 /Al. It is concluded that the oxidation mechanism of metallic Al irradiated by the water droplet beams differs from that formed when left in vacuum.
- Open Access
- 21 March 2025
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 39 (12) , e10029
Surface Ionization of Carbaryl, Papaverine, Cocaine, Morphine, and Triethylamine by Heated Surface‐Oxidized Metal Filaments of W, Re, Pd, Mo, Ti, and SUS304 Under Atmospheric Pressure: Ionization Mechanism
Rationale: The objective of the present study is to investigate the ionization mechanisms for atmospheric pressure surface ionization (APSI). Methods: APSI of carbaryl, papaverine, cocaine, morphine, and triethylamine using heated surface‐oxidized metal filaments of W, Re, Pd, Mo, Ti, and SUS304 were measured by mass spectrometry. Low‐volatility analytes dissolved in methanol were desorbed by Leidenfrost phenomenon‐assisted thermal desorption and introduced to the heated metal filament used as an emitter. Alkylamine benzene solutions were simply placed 10 mm below the filament. Results: Carbaryl, papaverine, cocaine, and morphine (M) gave protonated molecules [M+H] + with little fragment ions. Triethylamine (TEA) gave both [TEA+H] + and [TEA−H] + . Conclusion: Because [M+H] + was detected with little [M−H] + , which is usually detected as a major ion by vacuum surface ionization (VSI), it was concluded that [M+H] + is formed by the proton transfer reaction between the protonated filament surface and the gas‐phase analyte molecules approaching the solid surface. Namely, the heated metal filament acts as a Brønsted acid. This idea is supported by the APSI for TEA.
- 21 March 2025
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 39 (12) , e10029
Open AccessSurface Ionization of Carbaryl, Papaverine, Cocaine, Morphine, and Triethylamine by Heated Surface‐Oxidized Metal Filaments of W, Re, Pd, Mo, Ti, and SUS304 Under Atmospheric Pressure: Ionization Mechanism
Rationale: The objective of the present study is to investigate the ionization mechanisms for atmospheric pressure surface ionization (APSI). Methods: APSI of carbaryl, papaverine, cocaine, morphine, and triethylamine using heated surface‐oxidized metal filaments of W, Re, Pd, Mo, Ti, and SUS304 were measured by mass spectrometry. Low‐volatility analytes dissolved in methanol were desorbed by Leidenfrost phenomenon‐assisted thermal desorption and introduced to the heated metal filament used as an emitter. Alkylamine benzene solutions were simply placed 10 mm below the filament. Results: Carbaryl, papaverine, cocaine, and morphine (M) gave protonated molecules [M+H] + with little fragment ions. Triethylamine (TEA) gave both [TEA+H] + and [TEA−H] + . Conclusion: Because [M+H] + was detected with little [M−H] + , which is usually detected as a major ion by vacuum surface ionization (VSI), it was concluded that [M+H] + is formed by the proton transfer reaction between the protonated filament surface and the gas‐phase analyte molecules approaching the solid surface. Namely, the heated metal filament acts as a Brønsted acid. This idea is supported by the APSI for TEA.
- 30 October 2024
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 39 (1) , e9933
How do cocaine and morphine in methanol solution desorb at the last moment of Leidenfrost phenomenon‐assisted thermal desorption?
Rationale: The objective of the present study is to investigate desorption of low‐volatility analytes in Leidenfrost phenomenon‐assisted thermal desorption (LPTD). Methods: LPTD was investigated for 5 μL solutions of 0.03 ppm cocaine or morphine in methanol (sample weight: 0.12 ng) by using heated metal surfaces (240°C) polished by abrasives with grit numbers from #5000 (~3 μm) to #100 (~200 μm). Results: The analyte signals were detected only after the complete evaporation of methanol solvent and the formed analyte residues levitated on the heater surface. The strongest ion signals were obtained with grit number #100. Conclusions: Because the analyte residue does not come into contact with the heated surface but levitates on the hot substrate after the evaporation of the solvent, thermal decomposition of the analyte is largely suppressed. This is a great merit of LPTD for trace analysis of low‐volatility and thermally labile compounds.
- 30 October 2024
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 39 (1) , e9933
How do cocaine and morphine in methanol solution desorb at the last moment of Leidenfrost phenomenon‐assisted thermal desorption?
Rationale: The objective of the present study is to investigate desorption of low‐volatility analytes in Leidenfrost phenomenon‐assisted thermal desorption (LPTD). Methods: LPTD was investigated for 5 μL solutions of 0.03 ppm cocaine or morphine in methanol (sample weight: 0.12 ng) by using heated metal surfaces (240°C) polished by abrasives with grit numbers from #5000 (~3 μm) to #100 (~200 μm). Results: The analyte signals were detected only after the complete evaporation of methanol solvent and the formed analyte residues levitated on the heater surface. The strongest ion signals were obtained with grit number #100. Conclusions: Because the analyte residue does not come into contact with the heated surface but levitates on the hot substrate after the evaporation of the solvent, thermal decomposition of the analyte is largely suppressed. This is a great merit of LPTD for trace analysis of low‐volatility and thermally labile compounds.
- Open Access
- 10 September 2024
- Published by Surface Science Society Japan in Vacuum and Surface Science
- Vol. 67 (9) , 456
Report on the 17th Seminar of the Division of Microbeam Analysis
- 10 September 2024
- Published by Surface Science Society Japan in Vacuum and Surface Science
- Vol. 67 (9) , 456
Open AccessReport on the 17th Seminar of the Division of Microbeam Analysis
- 21 January 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 688, 115461
Solvent effect on the detection of peptides and proteins by nanoelectrospray ionization mass spectrometry: Anomalous behavior of aqueous 2-propanol
- 21 January 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 688, 115461
Solvent effect on the detection of peptides and proteins by nanoelectrospray ionization mass spectrometry: Anomalous behavior of aqueous 2-propanol
- 15 July 2023
- Published by Elsevier in Analytical Biochemistry
- Vol. 676, 115249
Analysis of human skin sebum and animal meats by heat pulse desorption/mass spectrometry using proximity corona discharge ionization
- 15 July 2023
- Published by Elsevier in Analytical Biochemistry
- Vol. 676, 115249
Analysis of human skin sebum and animal meats by heat pulse desorption/mass spectrometry using proximity corona discharge ionization