Marc A. Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marc A. Miller has a total of 191 co-authors. Here are the top co-authors by number of shared publications:
- Vivek Y. Reddy
Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York
10 shared publications - Jacob S. Koruth
Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, New York, NY
7 shared publications Srinivas R. Dukkipati
Helmsley Electrophysiology Center, Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
7 shared publications- William Whang
Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York, USA
7 shared publications - Srinivas R. Dukkipati
Department of Cardiology, Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, NY
6 shared publications - Daniel Musikantow
Helmsley Electrophysiology Center Icahn School of Medicine at Mount Sinai New York New York USA
5 shared publications
Latest Publications
- 30 August 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
Leadless Atrial Pacing at Bachmann's Bundle Guided by Electroanatomic Mapping and Intracardiac Ultrasound
Introduction: Leadless pacemakers (LPs) offer advantages over transvenous systems, but atrial LPs currently target the right atrial appendage (RAA), risking atrial dyssynchrony. Methods and Results: We report five patients in whom electroanatomic mapping and intracardiac ultrasound guided LP implantation into Bachmann's bundle (BB), a site shown to improve interatrial conduction and reduce atrial fibrillation risk. In four of five patients, BB fixation was successful with low pacing thresholds and short P‐wave duration. One patient required conversion to RAA pacing due to high BB pacing thresholds. No intraprocedural complications occurred. Conclusions: This series demonstrates the feasibility of leadless BB pacing, though technical challenges warrant further study.
- 30 August 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
Leadless Atrial Pacing at Bachmann's Bundle Guided by Electroanatomic Mapping and Intracardiac Ultrasound
Introduction: Leadless pacemakers (LPs) offer advantages over transvenous systems, but atrial LPs currently target the right atrial appendage (RAA), risking atrial dyssynchrony. Methods and Results: We report five patients in whom electroanatomic mapping and intracardiac ultrasound guided LP implantation into Bachmann's bundle (BB), a site shown to improve interatrial conduction and reduce atrial fibrillation risk. In four of five patients, BB fixation was successful with low pacing thresholds and short P‐wave duration. One patient required conversion to RAA pacing due to high BB pacing thresholds. No intraprocedural complications occurred. Conclusions: This series demonstrates the feasibility of leadless BB pacing, though technical challenges warrant further study.
- Open Access
- 22 July 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (3) , 172-182
Device-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up. METHODS: The PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54–69) years for the S-ICD and 64 (interquartile range, 56–69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48–1.12]); P =0.15). However, TV-ICD patients more often had a major complication or lead-related complication ( P =0.03 and P P =0.047). CONCLUSIONS: The PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- 22 July 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (3) , 172-182
Open AccessDevice-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up. METHODS: The PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54–69) years for the S-ICD and 64 (interquartile range, 56–69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48–1.12]); P =0.15). However, TV-ICD patients more often had a major complication or lead-related complication ( P =0.03 and P P =0.047). CONCLUSIONS: The PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- Open Access
- 1 November 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 17 (11) , e010822
Quality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- 1 November 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 17 (11) , e010822
Open AccessQuality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- 14 August 2024
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 10 (10) , 2224-2233
Long-Term Safety and Efficacy of Intraoperative Leadless Pacemaker Implantation During Valve Surgery
- 14 August 2024
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 10 (10) , 2224-2233
Long-Term Safety and Efficacy of Intraoperative Leadless Pacemaker Implantation During Valve Surgery
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Management of peri-device leaks after left atrial appendage closure using endovascular coils and/or amplatzer plugs and radiofrequency ablation
Background: Peri-device leaks (PDLs) after left atrial appendage closure (LAAC) portend a higher residual risk of thromboembolism in patients with Atrial Fibrillation (AF). Therefore, closure of PDLs has evolved as a procedural strategy to mitigate this residual thromboembolic risk. Objective: To present our procedural experience and outcome data in patients who underwent PDL-closure after prior LAAC. Methods: We performed a retrospective review of patients with follow-up imaging data (either transesophageal echocardiograms or Cardiac CT scans) performed at ∼1 year after LAAC between the time-period 5/2015 – 10/2022 to assess PDLs. Results: We included a total of 532 patients with follow-up imaging data. At a mean follow up of 696±359 days post-LAAC, 63 of 532 (11.8%) patients underwent PDL closure. These PDL closure cohort was age 73.1±9.5 years, 41 of 62 (65%) had paroxysmal AF, and the CHA2DS2-Vasc was 3.7±1.5. In 42 of 62 (67.7%) patients, the initial LAAC device was Watchman, and in 21 (33.8%) patients, it was Watchman-FLX. Of the PDL closure cohort, 8 of 62 (12.9%) had a post-LAAC thromboembolic event (transient ischemic attack [TIA], stroke or systemic embolism). The PDL size was 3.8±2.0 mm. PDL closure was performed using endovascular coils alone in 23 (37.1%), plugs (Amplatzer devices, Abbott) alone in 18 (29%), and combinations of both in 13 (19.4%) patients. In 8 (14.5%) patients, radiofrequency ablation was used in concert with both coils and plugs (Figure). There was only 1 complication (pericardial effusion drained percutaneously) during the PDL closure procedure. During follow-up post-PDL closure, no patient sustained a stroke and only 1 patient had a TIA (Table). Conclusions: Our data indicate that PDL closure after LAAC is feasible and safe, with a low risk of procedural complications. Such a strategy can be used in a subset of high-risk patients with PDL after LAAC who are at an elevated residual risk of thromboembolism.Table summarizing procedural strategies
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessManagement of peri-device leaks after left atrial appendage closure using endovascular coils and/or amplatzer plugs and radiofrequency ablation
Background: Peri-device leaks (PDLs) after left atrial appendage closure (LAAC) portend a higher residual risk of thromboembolism in patients with Atrial Fibrillation (AF). Therefore, closure of PDLs has evolved as a procedural strategy to mitigate this residual thromboembolic risk. Objective: To present our procedural experience and outcome data in patients who underwent PDL-closure after prior LAAC. Methods: We performed a retrospective review of patients with follow-up imaging data (either transesophageal echocardiograms or Cardiac CT scans) performed at ∼1 year after LAAC between the time-period 5/2015 – 10/2022 to assess PDLs. Results: We included a total of 532 patients with follow-up imaging data. At a mean follow up of 696±359 days post-LAAC, 63 of 532 (11.8%) patients underwent PDL closure. These PDL closure cohort was age 73.1±9.5 years, 41 of 62 (65%) had paroxysmal AF, and the CHA2DS2-Vasc was 3.7±1.5. In 42 of 62 (67.7%) patients, the initial LAAC device was Watchman, and in 21 (33.8%) patients, it was Watchman-FLX. Of the PDL closure cohort, 8 of 62 (12.9%) had a post-LAAC thromboembolic event (transient ischemic attack [TIA], stroke or systemic embolism). The PDL size was 3.8±2.0 mm. PDL closure was performed using endovascular coils alone in 23 (37.1%), plugs (Amplatzer devices, Abbott) alone in 18 (29%), and combinations of both in 13 (19.4%) patients. In 8 (14.5%) patients, radiofrequency ablation was used in concert with both coils and plugs (Figure). There was only 1 complication (pericardial effusion drained percutaneously) during the PDL closure procedure. During follow-up post-PDL closure, no patient sustained a stroke and only 1 patient had a TIA (Table). Conclusions: Our data indicate that PDL closure after LAAC is feasible and safe, with a low risk of procedural complications. Such a strategy can be used in a subset of high-risk patients with PDL after LAAC who are at an elevated residual risk of thromboembolism.Table summarizing procedural strategies
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Characteristics and incidence of peri-device leaks after left atrial appendage closure in patients with prior electrical isolation of left atrial appendage during catheter ablation
Background: Patients who undergo electrical isolation of left atrial appendage (eLAAi) during atrial fibrillation (AF) ablation have a higher subsequent risk of thromboembolism. In post-ablation patients with eLAAi who undergo mechanical LAA closure (LAAC), there are limited data on imaging and clinical outcomes during follow-up, particularly peri-device leaks (PDLs). Purpose: We investigated imaging outcomes on ~1 year follow up transesophageal echocardiography (TEE) for PDL and clinical outcomes in patients who had undergone LAAc after sustaining eLAAi from catheter ablation. Methods: We analyzed data from TEEs at ~1 year follow up in patients who had undergone LAAC with either the Watchman or Watchman-FLX device. The images were analyzed for evidence of any discernible PDL which also which also included the absence of thrombosis/obliteration of the distal LAA. "Severe" PDL was categorized as the leak size of >5 mm on follow up TEE imaging. Baseline characteristics, imaging and clinical outcomes were compared with univariate comparison using Fisher’s exact test, between the two subgroups of LAAC patients stratified according to prior h/o eLAAi. Results: A total of 532 patients underwent LAAC at our center between 03/2015 and 10/2022, with data available on ~1 year follow-up TEE imaging. Of these, 21 (3.9%) had undergone eLAAi during AF ablation prior to LAAC. At ~1 year follow up TEE imaging, the patients with prior h/o eLAAi had a numerically higher incidence of any PDL (42.9% vs 26.5%, p = 0.09). The incidence of severe PDL was significantly higher in the subgroup of patients with prior eLAAi as compared to patients without prior eLAAi (14.3% vs 3.3%, p = 0.04; Figure). There was no statistically-significant difference in the subsequent risk of thromboembolism between the eLAAi and control subgroups (4.8% vs 6.1%, p = 1.0) over an average follow-up of 577±331 days post-LAAC. Conclusions: A prior history of eLAAi during AF ablation was associated with a higher risk of severe PDLs (>5mm) on follow up imaging after LAAC. The finding of severe PDL in the eLAAi subgroup might be attributable to ostial fibrosis as a result of ablation which might affect the LAA endocardial surface interaction with the device fabric. The occurrence of a higher risk of severe PDL in patients with prior eLAAi after LAAC might necessitate PDL closure or resumption of anticoagulation in such patients to mitigate the risk of subsequent thromboembolism.igure showing our study schema and compa
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessCharacteristics and incidence of peri-device leaks after left atrial appendage closure in patients with prior electrical isolation of left atrial appendage during catheter ablation
Background: Patients who undergo electrical isolation of left atrial appendage (eLAAi) during atrial fibrillation (AF) ablation have a higher subsequent risk of thromboembolism. In post-ablation patients with eLAAi who undergo mechanical LAA closure (LAAC), there are limited data on imaging and clinical outcomes during follow-up, particularly peri-device leaks (PDLs). Purpose: We investigated imaging outcomes on ~1 year follow up transesophageal echocardiography (TEE) for PDL and clinical outcomes in patients who had undergone LAAc after sustaining eLAAi from catheter ablation. Methods: We analyzed data from TEEs at ~1 year follow up in patients who had undergone LAAC with either the Watchman or Watchman-FLX device. The images were analyzed for evidence of any discernible PDL which also which also included the absence of thrombosis/obliteration of the distal LAA. "Severe" PDL was categorized as the leak size of >5 mm on follow up TEE imaging. Baseline characteristics, imaging and clinical outcomes were compared with univariate comparison using Fisher’s exact test, between the two subgroups of LAAC patients stratified according to prior h/o eLAAi. Results: A total of 532 patients underwent LAAC at our center between 03/2015 and 10/2022, with data available on ~1 year follow-up TEE imaging. Of these, 21 (3.9%) had undergone eLAAi during AF ablation prior to LAAC. At ~1 year follow up TEE imaging, the patients with prior h/o eLAAi had a numerically higher incidence of any PDL (42.9% vs 26.5%, p = 0.09). The incidence of severe PDL was significantly higher in the subgroup of patients with prior eLAAi as compared to patients without prior eLAAi (14.3% vs 3.3%, p = 0.04; Figure). There was no statistically-significant difference in the subsequent risk of thromboembolism between the eLAAi and control subgroups (4.8% vs 6.1%, p = 1.0) over an average follow-up of 577±331 days post-LAAC. Conclusions: A prior history of eLAAi during AF ablation was associated with a higher risk of severe PDLs (>5mm) on follow up imaging after LAAC. The finding of severe PDL in the eLAAi subgroup might be attributable to ostial fibrosis as a result of ablation which might affect the LAA endocardial surface interaction with the device fabric. The occurrence of a higher risk of severe PDL in patients with prior eLAAi after LAAC might necessitate PDL closure or resumption of anticoagulation in such patients to mitigate the risk of subsequent thromboembolism.igure showing our study schema and compa
- 22 April 2024
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 10 (4) , 682-684
Ventricular Arrhythmias in Mitral Valve Prolapse
- 22 April 2024
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 10 (4) , 682-684
Ventricular Arrhythmias in Mitral Valve Prolapse
- 21 June 2023
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 9 (8) , 1276-1278
Catheter Ablation of Arrhythmic Mitral Valve Prolapse
- 21 June 2023
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 9 (8) , 1276-1278
Catheter Ablation of Arrhythmic Mitral Valve Prolapse
- 24 May 2023
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 9 (8) , 1709-1716
Arrhythmic Mitral Valve Prolapse With Only Mild or Moderate Mitral Regurgitation
- 24 May 2023
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 9 (8) , 1709-1716
Arrhythmic Mitral Valve Prolapse With Only Mild or Moderate Mitral Regurgitation
- 31 March 2023
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (5) , 1277-1285
SGLT2 inhibitors reduce sudden cardiac death risk in heart failure: Meta‐analysis of randomized clinical trials
Introduction: Multiple randomized controlled trials have demonstrated sodium‐glucose cotransporter‐2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure.Methods: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias).Results: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48−0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83−1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77–1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo.Conclusion: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long‐term impact of SGLT2i therapy on atrial and ventricular arrhythmias.
- 31 March 2023
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (5) , 1277-1285
SGLT2 inhibitors reduce sudden cardiac death risk in heart failure: Meta‐analysis of randomized clinical trials
Introduction: Multiple randomized controlled trials have demonstrated sodium‐glucose cotransporter‐2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure.Methods: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias).Results: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48−0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83−1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77–1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo.Conclusion: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long‐term impact of SGLT2i therapy on atrial and ventricular arrhythmias.