Jian-Jun Qin
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jian-Jun Qin has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Maung Htun Oo
Technology & Water Quality Office, Public Utilities Board, Singapore;
5 shared publicationsFook-Sin Wong
Environmental Technology Institute, #237, 18 Nanyang Drive, Singapore 637723
2 shared publications- Kiran A. Kekre
Technology & Water Quality Office, Public Utilities Board, Singapore;
2 shared publications Ying Li
Institute of Environmental Science and Engineering, Blk 2, #237, Innovation Centre (NTU), 18 Nanyang Drive, 637723 Singapore
2 shared publicationsYi‐Ming Cao
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, People's Republic of China
2 shared publicationsC.-M Ang
1 shared publication
Latest Publications
- 1 December 2010
- Published by IWA Publishing in Water Supply
- Vol. 10 (5) , 800-805
Optimization of direct-osmosis–high-salinity cleaning for reverse osmosis fouling control in water reuse
This paper focuses on the systematic approach adopted towards optimizing the salt consumption when using direct-osmosis–high-salinity (DO-HS) cleaning method for RO membranes in water reuse application. Trials were carried out on a pilot RO system with a capacity of 50 m3/day. Initially, proof of concept for the DO-HS method in water reuse application was established wherein the profile of osmotic driving force for DO backwash, DO backwash flow during HS injection, removal of foulants with DO-HS treatment and lower RO fouling rate with the DO-HS method were demonstrated. 6 months of trials further demonstrated that RO membrane fouling rate and CIP frequency could be significantly reduced with the DO-HS method and there was no impact on the performance of RO membranes. Further trials were carried out focusing of salt requirements and it was found that salt injection duration could be reduced by 68% while the 48-h interval of salt injection was not recommended. Currently, the salt consumption has been reduced from the initial at 0.5 ton to the current at 0.16 ton as per 10,000 m3/day production. The study is ongoing to achieve the target of 0.05 ton for ease of operation.
- 1 December 2010
- Published by IWA Publishing in Water Supply
- Vol. 10 (5) , 800-805
Optimization of direct-osmosis–high-salinity cleaning for reverse osmosis fouling control in water reuse
This paper focuses on the systematic approach adopted towards optimizing the salt consumption when using direct-osmosis–high-salinity (DO-HS) cleaning method for RO membranes in water reuse application. Trials were carried out on a pilot RO system with a capacity of 50 m3/day. Initially, proof of concept for the DO-HS method in water reuse application was established wherein the profile of osmotic driving force for DO backwash, DO backwash flow during HS injection, removal of foulants with DO-HS treatment and lower RO fouling rate with the DO-HS method were demonstrated. 6 months of trials further demonstrated that RO membrane fouling rate and CIP frequency could be significantly reduced with the DO-HS method and there was no impact on the performance of RO membranes. Further trials were carried out focusing of salt requirements and it was found that salt injection duration could be reduced by 68% while the 48-h interval of salt injection was not recommended. Currently, the salt consumption has been reduced from the initial at 0.5 ton to the current at 0.16 ton as per 10,000 m3/day production. The study is ongoing to achieve the target of 0.05 ton for ease of operation.
- 1 January 2010
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2010 (9) , 7095-7100
Enhanced Removals of Phosphate and DOC in Tertiary Treatment for Water Resue by a New Hybrid Coagulation-Ultrafiltration
- 1 January 2010
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2010 (9) , 7095-7100
Enhanced Removals of Phosphate and DOC in Tertiary Treatment for Water Resue by a New Hybrid Coagulation-Ultrafiltration
- 1 December 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 60 (11) , 2767-2774
Impact of anti-scalant on fouling of reverse osmosis membranes in reclamation of secondary effluent
The objective of the study was to evaluate the impact of anti-scalant on fouling of reverse osmosis (RO) membranes in reclamation of secondary effluent which was produced by a conventional activated sludge process at Kranji Water Reclamation Plant with the capacity of 151,000 m3/d. The study was carried out using a RO pilot plant with the capacity of 2.4 m3/h. The RO plant was in 2:1 configuration and was operated at 75% recovery and at membrane flux of 17 l m−2 h−1. Pilot trials were conducted with and without anti-scalant. Compositions of feed and concentrate streams were analyzed and the pilot data were normalized. The results of the study showed that the plant operation was stable during the first few days after stopping dosage of anti-scalant but after 3–6 days of operation the membranes were fouled. The time lag effect of anti-scalant without dosage was not reported previously and could be potentially beneficial to save chemicals. The membrane fouling was more serious at the second stage due to the formation of calcium phosphate scale when the pilot plant was operated without anti-scalant. The flux of fouled membranes could be completely recovered after clean-in-place (CIP) with citric acid, indicating that scaling dominated the fouling of the RO membranes. These findings in the study could be applied to select an appropriate anti-scalant for prevention from formation of calcium phosphate scale in the RO operation.
- 1 December 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 60 (11) , 2767-2774
Impact of anti-scalant on fouling of reverse osmosis membranes in reclamation of secondary effluent
The objective of the study was to evaluate the impact of anti-scalant on fouling of reverse osmosis (RO) membranes in reclamation of secondary effluent which was produced by a conventional activated sludge process at Kranji Water Reclamation Plant with the capacity of 151,000 m3/d. The study was carried out using a RO pilot plant with the capacity of 2.4 m3/h. The RO plant was in 2:1 configuration and was operated at 75% recovery and at membrane flux of 17 l m−2 h−1. Pilot trials were conducted with and without anti-scalant. Compositions of feed and concentrate streams were analyzed and the pilot data were normalized. The results of the study showed that the plant operation was stable during the first few days after stopping dosage of anti-scalant but after 3–6 days of operation the membranes were fouled. The time lag effect of anti-scalant without dosage was not reported previously and could be potentially beneficial to save chemicals. The membrane fouling was more serious at the second stage due to the formation of calcium phosphate scale when the pilot plant was operated without anti-scalant. The flux of fouled membranes could be completely recovered after clean-in-place (CIP) with citric acid, indicating that scaling dominated the fouling of the RO membranes. These findings in the study could be applied to select an appropriate anti-scalant for prevention from formation of calcium phosphate scale in the RO operation.
- 10 May 2006
- Published by Elsevier in Desalination
- Vol. 191 (1-3) , 359-364
Pilot study on the treatment of spent solvent cleaning rinse in metal plating
- 10 May 2006
- Published by Elsevier in Desalination
- Vol. 191 (1-3) , 359-364
Pilot study on the treatment of spent solvent cleaning rinse in metal plating
- 18 October 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 99 (1) , 430-435
Preparation of poly(ether sulfone) hollow fiber UF membrane for removal of NOM
- 18 October 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 99 (1) , 430-435
Preparation of poly(ether sulfone) hollow fiber UF membrane for removal of NOM
- 6 June 2005
- Published by Elsevier in Separation and Purification Technology
- Vol. 46 (1-2) , 125-128
TOC removal in reclamation of municipal wastewater by RO
- 6 June 2005
- Published by Elsevier in Separation and Purification Technology
- Vol. 46 (1-2) , 125-128
TOC removal in reclamation of municipal wastewater by RO
- 22 April 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 97 (1) , 227-231
Effect of hypochlorite concentration on properties of posttreated outer‐skin ultrafiltration membranes spun from cellulose acetate/poly(vinyl pyrrolidone) blends
An outer‐skin hollow‐fiber ultrafiltration (UF) membrane was spun from a new dope solution containing cellulose acetate (CA)/poly(vinyl pyrrolidone) (PVP 360K)/N‐methyl‐2‐pyrrolidone (NMP)/water using a wet‐spinning technique. The as‐spun fibers were posttreated with a hypochlorite solution over a range of concentrations for a fixed period of 24 h. The experimental results showed that the pure water flux of the treated membrane increased with increasing hypochlorite concentration. The treated membrane experienced an increased fouling tendency with increasing hypochlorite concentration because the hydrophilicity of the treated membrane decreased as a result of the removal of PVP contents in the membrane matrix after hypochlorite treatment. SEM images revealed that the membrane had an outer dense skin, a porous inner surface, and a spongelike structure, which confirmed that addition of PVP favored the suppression of macrovoids in the membrane. The membrane pore size could be significantly increased when the hypochlorite concentration reached 200 mg/L. It was concluded that hypochlorite treatment provided an additional option to easily alter the pore size of UF membranes. © 2005 Wiley Periodicals, Inc. J Appl Polym Sci 97: 227–231, 2005
- 22 April 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 97 (1) , 227-231
Effect of hypochlorite concentration on properties of posttreated outer‐skin ultrafiltration membranes spun from cellulose acetate/poly(vinyl pyrrolidone) blends
An outer‐skin hollow‐fiber ultrafiltration (UF) membrane was spun from a new dope solution containing cellulose acetate (CA)/poly(vinyl pyrrolidone) (PVP 360K)/N‐methyl‐2‐pyrrolidone (NMP)/water using a wet‐spinning technique. The as‐spun fibers were posttreated with a hypochlorite solution over a range of concentrations for a fixed period of 24 h. The experimental results showed that the pure water flux of the treated membrane increased with increasing hypochlorite concentration. The treated membrane experienced an increased fouling tendency with increasing hypochlorite concentration because the hydrophilicity of the treated membrane decreased as a result of the removal of PVP contents in the membrane matrix after hypochlorite treatment. SEM images revealed that the membrane had an outer dense skin, a porous inner surface, and a spongelike structure, which confirmed that addition of PVP favored the suppression of macrovoids in the membrane. The membrane pore size could be significantly increased when the hypochlorite concentration reached 200 mg/L. It was concluded that hypochlorite treatment provided an additional option to easily alter the pore size of UF membranes. © 2005 Wiley Periodicals, Inc. J Appl Polym Sci 97: 227–231, 2005
- 17 November 2004
- Published by Elsevier in Journal of Membrane Science
- Vol. 247 (1-2) , 119-125
Hollow fiber ultrafiltration membranes with enhanced flux for humic acid removal
- 17 November 2004
- Published by Elsevier in Journal of Membrane Science
- Vol. 247 (1-2) , 119-125
Hollow fiber ultrafiltration membranes with enhanced flux for humic acid removal
- 1 July 2003
- Published by Elsevier in Water Research
- Vol. 37 (13) , 3269-3278
A dual membrane UF/RO process for reclamation of spent rinses from a nickel-plating operation—a case study
- 1 July 2003
- Published by Elsevier in Water Research
- Vol. 37 (13) , 3269-3278
A dual membrane UF/RO process for reclamation of spent rinses from a nickel-plating operation—a case study