Weonjae Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weonjae Kim has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Jinhong Jung
8 shared publicationsYeoju Jang
8 shared publicationsHyunman Lim
7 shared publicationsNari Park
7 shared publicationsHyangyoun Chang
6 shared publicationsHyun-Man Lim
5 shared publications
Latest Publications
- Open Access
- 25 March 2026
- Published by Elsevier in Environmental Technology & Innovation
- Vol. 42
Development of high-concentration ammonium removal process via NH4+ ion exchange and Mg–P recycling using struvite
- 25 March 2026
- Published by Elsevier in Environmental Technology & Innovation
- Vol. 42
Open AccessDevelopment of high-concentration ammonium removal process via NH4+ ion exchange and Mg–P recycling using struvite
- Open Access
- 1 December 2025
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 42 (12) , 1011-1020
The Design of an Electrode Performance Evaluation Platform of Low-temperature Solid Oxide Fuel Cells for High-efficiency Biogas Energy Conversion
This study presents a performance evaluation platform for sputtered thin-film electrodes used in biogas-driven, low-temperature solid oxide fuel cells (SOFCs). The design considerations include electrolyte material composition and thickness, anode material composition and thickness, anode fuel composition, and cathode composition and thickness, all derived from a review of existing literature. For the electrolyte, we propose a thickness of 100 μm for the main electrolyte made of gadolinium-doped ceria (GDC) and 0.1 μm for the auxiliary electrolyte made of scandia-stabilized zirconia. In terms of anode fabrication, we suggest a material composition of Ru/Ni-Cu-GDC, with thicknesses of 1 μm for Ni-Cu-GDC and a few nanometers for Ru in the nanoporous anode. For the anode fuel supply, we recommend mole ratios of 45% to 75% CH4 and 25% to 55% CO2 to assess the impact of biogas composition on power performance. Lastly, for the cathode, we propose a material composition of Pt-Ti-samarium-doped ceria with a thickness of 100 nm for the nanoporous structure.
- 1 December 2025
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 42 (12) , 1011-1020
Open AccessThe Design of an Electrode Performance Evaluation Platform of Low-temperature Solid Oxide Fuel Cells for High-efficiency Biogas Energy Conversion
This study presents a performance evaluation platform for sputtered thin-film electrodes used in biogas-driven, low-temperature solid oxide fuel cells (SOFCs). The design considerations include electrolyte material composition and thickness, anode material composition and thickness, anode fuel composition, and cathode composition and thickness, all derived from a review of existing literature. For the electrolyte, we propose a thickness of 100 μm for the main electrolyte made of gadolinium-doped ceria (GDC) and 0.1 μm for the auxiliary electrolyte made of scandia-stabilized zirconia. In terms of anode fabrication, we suggest a material composition of Ru/Ni-Cu-GDC, with thicknesses of 1 μm for Ni-Cu-GDC and a few nanometers for Ru in the nanoporous anode. For the anode fuel supply, we recommend mole ratios of 45% to 75% CH4 and 25% to 55% CO2 to assess the impact of biogas composition on power performance. Lastly, for the cathode, we propose a material composition of Pt-Ti-samarium-doped ceria with a thickness of 100 nm for the nanoporous structure.
- Open Access
- 6 October 2025
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 157, 236-245
Continuous manufacturing of microsized vaterite using CO2 supersaturated water in a semi-pilot plant
- 6 October 2025
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 157, 236-245
Open AccessContinuous manufacturing of microsized vaterite using CO2 supersaturated water in a semi-pilot plant
- Open Access
New Strategy to Maximize Phosphorus Utilization of Sewage Sludge Incineration Ash for Struvite Crystallization
Struvite crystallization can recover nitrogen and phosphorus simultaneously from various kinds of wastewaters as a slow-release fertilizer. However, the enhancement of the removal efficiency of NH4-N is challenging because the molar concentration of NH4-N is higher than that of PO4-P in many types of sewage including digested sludge filtrate. In this study, phosphorus eluate was recovered from sewage sludge incineration ash (SSA) and applied to the struvite crystallization process to increase the removal efficiency of NH4-N for the digested sludge filtrate. Under acidic conditions, a maximum of 98.4% of phosphorus was eluted from SSA; in alkaline conditions, a maximum of 51.2% was eluted; and in sequential elution conditions with (NaOH+H2SO4), a maximum of 98.0% was eluted. Jar tests were performed by injecting three types of eluates (H2SO4 1 N_elulate, NaOH 1 N_elulate, and (NaOH+H2SO4)_eluate), and PO4-P was stably removed (>86%) under all tested conditions. When the NaOH 1 N_eluate was injected, the NH4-N removal efficiency was highest at 84.4%, followed by 78.4% with the (NaOH+H2SO4)_eluate, and 58.7% with the H2SO4 1 N_eluate at the molar ratio of Mg:P:N of 1.5:1.5:1. In addition, the sequential jar tests were conducted by injecting both the NaOH 1 N_eluate and (NaOH+H2SO4)_eluate. In the pH range of 8.5–9.5, the PO4-P and NH4-N removal efficiencies reached 92.3–94.5% and 97.9–99.1%, respectively. X-ray diffraction analyses confirmed that the majority of the crystal phases were struvite forms. Therefore, the combined application of both the NaOH 1 N_eluate and (NaOH+H2SO4)_eluate was adequate to enhance not only the phosphorus recovery but also the removal efficiencies of PO4-P and NH4-N. SSA recovering PO4-P could be utilized as a new phosphorus source in the struvite crystallization process.
Open AccessNew Strategy to Maximize Phosphorus Utilization of Sewage Sludge Incineration Ash for Struvite Crystallization
Struvite crystallization can recover nitrogen and phosphorus simultaneously from various kinds of wastewaters as a slow-release fertilizer. However, the enhancement of the removal efficiency of NH4-N is challenging because the molar concentration of NH4-N is higher than that of PO4-P in many types of sewage including digested sludge filtrate. In this study, phosphorus eluate was recovered from sewage sludge incineration ash (SSA) and applied to the struvite crystallization process to increase the removal efficiency of NH4-N for the digested sludge filtrate. Under acidic conditions, a maximum of 98.4% of phosphorus was eluted from SSA; in alkaline conditions, a maximum of 51.2% was eluted; and in sequential elution conditions with (NaOH+H2SO4), a maximum of 98.0% was eluted. Jar tests were performed by injecting three types of eluates (H2SO4 1 N_elulate, NaOH 1 N_elulate, and (NaOH+H2SO4)_eluate), and PO4-P was stably removed (>86%) under all tested conditions. When the NaOH 1 N_eluate was injected, the NH4-N removal efficiency was highest at 84.4%, followed by 78.4% with the (NaOH+H2SO4)_eluate, and 58.7% with the H2SO4 1 N_eluate at the molar ratio of Mg:P:N of 1.5:1.5:1. In addition, the sequential jar tests were conducted by injecting both the NaOH 1 N_eluate and (NaOH+H2SO4)_eluate. In the pH range of 8.5–9.5, the PO4-P and NH4-N removal efficiencies reached 92.3–94.5% and 97.9–99.1%, respectively. X-ray diffraction analyses confirmed that the majority of the crystal phases were struvite forms. Therefore, the combined application of both the NaOH 1 N_eluate and (NaOH+H2SO4)_eluate was adequate to enhance not only the phosphorus recovery but also the removal efficiencies of PO4-P and NH4-N. SSA recovering PO4-P could be utilized as a new phosphorus source in the struvite crystallization process.
- Open Access
- 12 June 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (12) , 5008
A Wet Scrubber and Electrooxidation System for the Efficient Removal of Odor: A Bench-Scale Study
Odor emissions are a crucial component of atmospheric pollution. As odor is a sensory pollutant, its management and treatment are recalcitrant. A wet scrubber (WS) is an efficient technique for odor removal, but disposal of waste liquid discharge leads to secondary pollution and CO2 emissions during transportation. In this study, a system consisting of WS and electrooxidation (EO) was developed and installed in a swine manure fermentation facility. The absorption and EO characteristics were estimated through the practical implementation of a bench-scale WS (BSW). For EO, a dimensionally stable anode and Cl− were applied. When the BSW was operated without EO, an L/G ratio of 8.88 was essential for securing the simultaneous removal rate of the four odorants (hydrogen sulfide, methyl mercaptan, ammonia, and total volatile compound). With the operation of the EO, the period to change the liquid based on equilibrium was postponed due to the continuous oxidation of the odorants absorbed in the liquid. As the applied current increased, the change period was further prolonged. However, the oxidation and absorption rates differed depending on the odor substances, due to differences in their physicochemical characteristics. Hydrogen sulfide and methyl mercaptan exhibited similar absorption and oxidation rates. Ammonia had a high absorption rate and a low oxidation rate. The acetaldehyde oxidation rate was the most sluggish among the substances. These findings demonstrate that simultaneous consideration of Henry’s constant and the reactivity of the target pollutant with HOCl renders the design of BSW appropriate for treating odor gases containing various odorants. This study contributes to efforts to address environmental problems concerning odors and also to global climate threats.
- 12 June 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (12) , 5008
Open AccessA Wet Scrubber and Electrooxidation System for the Efficient Removal of Odor: A Bench-Scale Study
Odor emissions are a crucial component of atmospheric pollution. As odor is a sensory pollutant, its management and treatment are recalcitrant. A wet scrubber (WS) is an efficient technique for odor removal, but disposal of waste liquid discharge leads to secondary pollution and CO2 emissions during transportation. In this study, a system consisting of WS and electrooxidation (EO) was developed and installed in a swine manure fermentation facility. The absorption and EO characteristics were estimated through the practical implementation of a bench-scale WS (BSW). For EO, a dimensionally stable anode and Cl− were applied. When the BSW was operated without EO, an L/G ratio of 8.88 was essential for securing the simultaneous removal rate of the four odorants (hydrogen sulfide, methyl mercaptan, ammonia, and total volatile compound). With the operation of the EO, the period to change the liquid based on equilibrium was postponed due to the continuous oxidation of the odorants absorbed in the liquid. As the applied current increased, the change period was further prolonged. However, the oxidation and absorption rates differed depending on the odor substances, due to differences in their physicochemical characteristics. Hydrogen sulfide and methyl mercaptan exhibited similar absorption and oxidation rates. Ammonia had a high absorption rate and a low oxidation rate. The acetaldehyde oxidation rate was the most sluggish among the substances. These findings demonstrate that simultaneous consideration of Henry’s constant and the reactivity of the target pollutant with HOCl renders the design of BSW appropriate for treating odor gases containing various odorants. This study contributes to efforts to address environmental problems concerning odors and also to global climate threats.
- Open Access
Direct Electrooxidation of Ammonia-Enriched Wastewater Using a Bipolar Membrane-Integrated Electrolytic Cell
The treatment of reject water containing concentrated ammonia and non-biodegradable organics is a challenging task in wastewater treatment plants. To address this problem, we propose a novel process consisting of a selective ammonium-exchange resin and an ammonia electrooxidation reaction (AmER-AOR). Because an alkaline condition is essential for direct ammonia oxidation, the use of a bipolar membrane (BPM) was helpful. Nonetheless, an initial pH of 13 and KOH addition were required to maintain a high alkalinity for the complete elimination of ammonia. The linear sweep voltammogram elucidated the high pH requirement and ammonia oxidation promotion. When the current density varied from 30 to 80 mA cm−2, 60 mA cm−2 showed the highest current efficiency (30.39%) and the lowest specific energy demand (95.3 kWh/kg-N), indicating the most energy-effective condition. Increasing the initial concentration of ammonia from 0.1 M to 0.5 M improved the current efficiency (51.57%), demonstrating an additional energy-effective strategy for the AmER-AOR. The energy efficiency of pure H2 production in the cathodic chamber was 30%. To estimate the viability for practical applications, reject water collected from a local wastewater treatment plant was applied in the AmER-AOR. Notably, no significant difference in the ammonia removal rate was observed with synthetic wastewater. To the best of our knowledge, this is the first study that employs a BPM as a separator and OH− supplier for direct ammonia oxidation. Our findings reveal that the AmER-AOR with a BPM has promising practical applicability in the treatment of reject water and energy production.
Open AccessDirect Electrooxidation of Ammonia-Enriched Wastewater Using a Bipolar Membrane-Integrated Electrolytic Cell
The treatment of reject water containing concentrated ammonia and non-biodegradable organics is a challenging task in wastewater treatment plants. To address this problem, we propose a novel process consisting of a selective ammonium-exchange resin and an ammonia electrooxidation reaction (AmER-AOR). Because an alkaline condition is essential for direct ammonia oxidation, the use of a bipolar membrane (BPM) was helpful. Nonetheless, an initial pH of 13 and KOH addition were required to maintain a high alkalinity for the complete elimination of ammonia. The linear sweep voltammogram elucidated the high pH requirement and ammonia oxidation promotion. When the current density varied from 30 to 80 mA cm−2, 60 mA cm−2 showed the highest current efficiency (30.39%) and the lowest specific energy demand (95.3 kWh/kg-N), indicating the most energy-effective condition. Increasing the initial concentration of ammonia from 0.1 M to 0.5 M improved the current efficiency (51.57%), demonstrating an additional energy-effective strategy for the AmER-AOR. The energy efficiency of pure H2 production in the cathodic chamber was 30%. To estimate the viability for practical applications, reject water collected from a local wastewater treatment plant was applied in the AmER-AOR. Notably, no significant difference in the ammonia removal rate was observed with synthetic wastewater. To the best of our knowledge, this is the first study that employs a BPM as a separator and OH− supplier for direct ammonia oxidation. Our findings reveal that the AmER-AOR with a BPM has promising practical applicability in the treatment of reject water and energy production.
- Open Access
- 14 November 2022
- Published by MDPI AG in Fermentation
- Vol. 8 (11) , 638
Anaerobic Co-Digestion of Bioplastics and Food Waste under Mesophilic and Thermophilic Conditions: Synergistic Effect and Biodegradation
To mitigate the various problems caused by using conventional plastics, bioplastic (BP) has emerged as a substitute for plastics. BP wastes after use are commonly treated using composting, causing many environmental problems. Anaerobic digestion (AD) has become prominent as an alternative method of producing renewable energy. The aim of this study was to estimate the methane production yield (MPY) of BPs (polylactic acid (PLA) and polyhydroxyalkanoate (PHA)) with mechanical pretreatment (particle size < 0.5 cm) and investigate the effect of co-digestion of BPs and food waste (FW). Batch experiments were conducted under mesophilic and thermophilic conditions at various mixing ratios (FW/PLA or PHA = 95:5 and 90:10 on a weight basis). During 20 d of digestion at temperatures of 37 and 55 °C, MPYs of PHA were 153.8–172.0 mL CH4/g chemical oxygen demand (COD), but that of PLA was significantly low (4/g COD). Higher MPYs were attained at 55 °C than at 37 °C. The synergistic effects of FW addition on BP AD were observed at both temperatures, especially at 55 °C. By comparing theoretical (based on mono-digestion results) and actual (based on co-digestion results) MPYs, the synergistic effect of FW addition on MPY of co-digestion reached 8.5–26.6% and 12.7–25.5% for PLA- and PHA-fed tests, respectively. The biodegradation rates (on a volatile solids (VS) basis) of PLA and PHA were 6.0–13.7% and 49.1–52.3% and increased by 1.8–4.3 and 1.2–1.5 times in the PLA- and PHA-fed co-digestion tests, respectively. Co-digestion of FW might be a feasible treatment option for BPs combined with simple mechanical pretreatment.
- 14 November 2022
- Published by MDPI AG in Fermentation
- Vol. 8 (11) , 638
Open AccessAnaerobic Co-Digestion of Bioplastics and Food Waste under Mesophilic and Thermophilic Conditions: Synergistic Effect and Biodegradation
To mitigate the various problems caused by using conventional plastics, bioplastic (BP) has emerged as a substitute for plastics. BP wastes after use are commonly treated using composting, causing many environmental problems. Anaerobic digestion (AD) has become prominent as an alternative method of producing renewable energy. The aim of this study was to estimate the methane production yield (MPY) of BPs (polylactic acid (PLA) and polyhydroxyalkanoate (PHA)) with mechanical pretreatment (particle size < 0.5 cm) and investigate the effect of co-digestion of BPs and food waste (FW). Batch experiments were conducted under mesophilic and thermophilic conditions at various mixing ratios (FW/PLA or PHA = 95:5 and 90:10 on a weight basis). During 20 d of digestion at temperatures of 37 and 55 °C, MPYs of PHA were 153.8–172.0 mL CH4/g chemical oxygen demand (COD), but that of PLA was significantly low (4/g COD). Higher MPYs were attained at 55 °C than at 37 °C. The synergistic effects of FW addition on BP AD were observed at both temperatures, especially at 55 °C. By comparing theoretical (based on mono-digestion results) and actual (based on co-digestion results) MPYs, the synergistic effect of FW addition on MPY of co-digestion reached 8.5–26.6% and 12.7–25.5% for PLA- and PHA-fed tests, respectively. The biodegradation rates (on a volatile solids (VS) basis) of PLA and PHA were 6.0–13.7% and 49.1–52.3% and increased by 1.8–4.3 and 1.2–1.5 times in the PLA- and PHA-fed co-digestion tests, respectively. Co-digestion of FW might be a feasible treatment option for BPs combined with simple mechanical pretreatment.
- 15 June 2022
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 20 (5) , 4931-4942
Ammonium removal and recovery using natural zeolites and air stripping technique for greywater treatment
- 15 June 2022
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 20 (5) , 4931-4942
Ammonium removal and recovery using natural zeolites and air stripping technique for greywater treatment
- Open Access
Changes in Organics and Nitrogen during Ozonation of Anaerobic Digester Effluent
The objective of this study is to investigate the consequence of ozone dosage rate on the qualitative change in organic compounds and nitrogen in anaerobic digester effluent during the ozone process. Therefore, ozonation improves the biodegradability of recalcitrant organic compounds, quickly oxidizes the unsaturated bond, and forms radicals that continue to deteriorate other organic matter. In this study, ozonation was performed in a microbubble column reactor; the use of microbubble ozone improves the status of chemical oxygen demand (COD) and changes of organic nitrogen to inorganic compounds. The ozone injection rates were 1.0, 3.2, and 6.2 mg/L/min. The samples obtained during the ozone treatments were monitored for CODMn, CODCr, TOC, NO2−-N, NO3−-N, NH4+-N, T-N, and Org-N. The ozone dose increased 1.0 to 6.2 mg/L and it increased the degradation ratio 40% and the total organic carbon 20% during 20 min of reaction time. During the ozonation, the CODCr and CODMn values were increased per unit of ozone consumption. The ozone treatment showed organic nitrogen mineralization and degradation of organic compounds with the contribution of the microbubble ozone oxidation process and is a good option for removing non-biodegradable organic compounds. The original application of the microbubble ozone process, with the degradation of organic compounds from a domestic wastewater treatment plant, was investigated.
Open AccessChanges in Organics and Nitrogen during Ozonation of Anaerobic Digester Effluent
The objective of this study is to investigate the consequence of ozone dosage rate on the qualitative change in organic compounds and nitrogen in anaerobic digester effluent during the ozone process. Therefore, ozonation improves the biodegradability of recalcitrant organic compounds, quickly oxidizes the unsaturated bond, and forms radicals that continue to deteriorate other organic matter. In this study, ozonation was performed in a microbubble column reactor; the use of microbubble ozone improves the status of chemical oxygen demand (COD) and changes of organic nitrogen to inorganic compounds. The ozone injection rates were 1.0, 3.2, and 6.2 mg/L/min. The samples obtained during the ozone treatments were monitored for CODMn, CODCr, TOC, NO2−-N, NO3−-N, NH4+-N, T-N, and Org-N. The ozone dose increased 1.0 to 6.2 mg/L and it increased the degradation ratio 40% and the total organic carbon 20% during 20 min of reaction time. During the ozonation, the CODCr and CODMn values were increased per unit of ozone consumption. The ozone treatment showed organic nitrogen mineralization and degradation of organic compounds with the contribution of the microbubble ozone oxidation process and is a good option for removing non-biodegradable organic compounds. The original application of the microbubble ozone process, with the degradation of organic compounds from a domestic wastewater treatment plant, was investigated.