Alberto Ortín
Alberto Ortín has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
B. Monrabal
Polymer Char; Valencia Spain
5 shared publications- José Ramón Torres-Lapasió
Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, Avda. Vicent Andrés Estellés s/n, 46100 Burjassot, Spain
3 shared publications - María Celia García Alvarez-Coque
Departament de Química Analítica, Universitat de València, c/Dr. Moliner 50, Burjassot, Spain
3 shared publications P. del Hierro
Polymer Char; Valencia Spain
3 shared publicationsWallace W. Yau
Polymer Characterization Consultant USA
3 shared publicationsE. López
Polymer Char, Gustave Eiffel 8 Valencia Technology Park 46980 Paterna Valencia Spain
2 shared publications
Latest Publications
- 1 May 2018
- Published by Wiley in Plastics Engineering
- Vol. 74 (5) , 48-51
Newly Developed Resins More Challenging to Control in Production Plants
- 1 May 2018
- Published by Wiley in Plastics Engineering
- Vol. 74 (5) , 48-51
Newly Developed Resins More Challenging to Control in Production Plants
- 15 February 2018
- Published by Wiley in Macromolecular Symposia
- Vol. 377 (1)
Simplified Robust Triple Detection Methods for High Temperature GPC Analysis of Polyolefins
Very powerful triple detector high‐temperature gel permeation chromatography (HT‐GPC) systems equipped with concentration, viscosity, and multiple angle light scattering detectors can be found in many polyolefin characterization laboratories. However, the complexity and sometimes lack of robustness of some detection methods often result in failure to achieve the required precision and long‐term reliability to properly support the industrial needs. Two methods for data processing in triple detector HT‐GPC of polyolefins are here described aiming at overcoming those difficulties, specifically those related to the application of multiple angle light scattering. In the first place, we propose here a data processing method using light scattering data collected at only one angle, with application of a dissymmetry correction based on an estimate of the molecular size from the hydrodynamic volume given by the universal calibration. This method (SALSDC: single‐angle light scattering with dissymmetry correction) is simple and robust for molar mass distribution and averages. Long chain branching detection and quantification is another field plagued with lack of precision and inconsistency problems, due to the difficulty in collecting reliable radius of gyration (Rg) data using MALS, for calculation of the g‐index. A novel approach to estimate the g‐index, based on point‐by‐point calculation of the gpcBR index is here described and evaluated.
- 15 February 2018
- Published by Wiley in Macromolecular Symposia
- Vol. 377 (1)
Simplified Robust Triple Detection Methods for High Temperature GPC Analysis of Polyolefins
Very powerful triple detector high‐temperature gel permeation chromatography (HT‐GPC) systems equipped with concentration, viscosity, and multiple angle light scattering detectors can be found in many polyolefin characterization laboratories. However, the complexity and sometimes lack of robustness of some detection methods often result in failure to achieve the required precision and long‐term reliability to properly support the industrial needs. Two methods for data processing in triple detector HT‐GPC of polyolefins are here described aiming at overcoming those difficulties, specifically those related to the application of multiple angle light scattering. In the first place, we propose here a data processing method using light scattering data collected at only one angle, with application of a dissymmetry correction based on an estimate of the molecular size from the hydrodynamic volume given by the universal calibration. This method (SALSDC: single‐angle light scattering with dissymmetry correction) is simple and robust for molar mass distribution and averages. Long chain branching detection and quantification is another field plagued with lack of precision and inconsistency problems, due to the difficulty in collecting reliable radius of gyration (Rg) data using MALS, for calculation of the g‐index. A novel approach to estimate the g‐index, based on point‐by‐point calculation of the gpcBR index is here described and evaluated.
- 15 October 2015
- Published by Wiley in Macromolecular Symposia
- Vol. 356 (1) , 87-94
Studies on the Application of Filter‐Based IR Detector for Polyolefin Characterization with HT‐SEC
Summary: Even though polyolefins are simple polymers from a chemical structure point of view, their full characterization in practice is still an intriguing task. Basic macromolecular characteristics of polyethylene or polypropylene like molar mass moments and their distributions (MMD) but also chain conformation and thus information on long‐chain branching, can be addressed with high‐temperature size‐exclusion chromatography (HT‐SEC). Hyphenation of infrared detection to size‐exclusion chromatography expands possibilities of SEC even more and allows to reveal comonomer incorporation across molecular weight and thus generate a fingerprint of a given catalytic system used in polyolefin synthesis. Multiband filter‐based infrared detector gives an easy and fast access to so‐called short chain branching distribution (SCB) vs MMD by coupling to HT‐SEC. In this work, we summarize recent findings on application of a filter‐based IR detector (IR5‐MCT) towards characterization of polyolefins synthesized with different catalytic systems and varying comonomer types. It is found that for copolymers of polyethylene with 1‐butene, 1‐hexene or 1‐octene (non‐C3), one linear calibration line can be used in the range up to 70 CH3/1000TC, thus covering the range necessary for common applications like for instance HDPE or LLDPE. For ethylene‐propylene copolymers (C3), over the broad range up to 333 CH3/1000TC, the calibration line is best fitted to a second order polynomial. C3 copolymers show a different behavior compared to non‐C3 copolymers, irrespective the amount of comonomer incorporated in the polymer. We show that mixtures of PP and PE homopolymers result in equivalent response as the copolymers of the same average composition and thus can also be used to set up calibration lines. Based on this evaluation practical aspects of IR5‐MCT calibration are discussed.
- 15 October 2015
- Published by Wiley in Macromolecular Symposia
- Vol. 356 (1) , 87-94
Studies on the Application of Filter‐Based IR Detector for Polyolefin Characterization with HT‐SEC
Summary: Even though polyolefins are simple polymers from a chemical structure point of view, their full characterization in practice is still an intriguing task. Basic macromolecular characteristics of polyethylene or polypropylene like molar mass moments and their distributions (MMD) but also chain conformation and thus information on long‐chain branching, can be addressed with high‐temperature size‐exclusion chromatography (HT‐SEC). Hyphenation of infrared detection to size‐exclusion chromatography expands possibilities of SEC even more and allows to reveal comonomer incorporation across molecular weight and thus generate a fingerprint of a given catalytic system used in polyolefin synthesis. Multiband filter‐based infrared detector gives an easy and fast access to so‐called short chain branching distribution (SCB) vs MMD by coupling to HT‐SEC. In this work, we summarize recent findings on application of a filter‐based IR detector (IR5‐MCT) towards characterization of polyolefins synthesized with different catalytic systems and varying comonomer types. It is found that for copolymers of polyethylene with 1‐butene, 1‐hexene or 1‐octene (non‐C3), one linear calibration line can be used in the range up to 70 CH3/1000TC, thus covering the range necessary for common applications like for instance HDPE or LLDPE. For ethylene‐propylene copolymers (C3), over the broad range up to 333 CH3/1000TC, the calibration line is best fitted to a second order polynomial. C3 copolymers show a different behavior compared to non‐C3 copolymers, irrespective the amount of comonomer incorporated in the polymer. We show that mixtures of PP and PE homopolymers result in equivalent response as the copolymers of the same average composition and thus can also be used to set up calibration lines. Based on this evaluation practical aspects of IR5‐MCT calibration are discussed.
- 15 October 2015
- Published by Wiley in Macromolecular Symposia
- Vol. 356 (1) , 110-121
Analysis of Propylene‐1‐Butene Copolymer Composition by GPC with Online Detectors
Summary: The use of High Temperature Gel Permeation Chromatography (HT‐GPC) with online infrared (IR) detector to analyze copolymer composition of propylene‐1‐butene (P‐B) copolymer is investigated in this study. This technique is based on the measurement of the methyl to methylene ratio by an online infrared detector. This measurement is made possible by the highly discriminating power of a modern multiple band filter‐based IR detector (IR5 MCT) to detect the P–B copolymer chemical structure. Also discussed is an alternative method, based on the application of the triple‐detector GPC (GPC with IR, viscometer and light scattering coupled detectors) approach and Mark–Houwink plot.
- 15 October 2015
- Published by Wiley in Macromolecular Symposia
- Vol. 356 (1) , 110-121
Analysis of Propylene‐1‐Butene Copolymer Composition by GPC with Online Detectors
Summary: The use of High Temperature Gel Permeation Chromatography (HT‐GPC) with online infrared (IR) detector to analyze copolymer composition of propylene‐1‐butene (P‐B) copolymer is investigated in this study. This technique is based on the measurement of the methyl to methylene ratio by an online infrared detector. This measurement is made possible by the highly discriminating power of a modern multiple band filter‐based IR detector (IR5 MCT) to detect the P–B copolymer chemical structure. Also discussed is an alternative method, based on the application of the triple‐detector GPC (GPC with IR, viscometer and light scattering coupled detectors) approach and Mark–Houwink plot.
- 15 October 2015
- Published by Wiley in Macromolecular Symposia
- Vol. 356 (1) , 95-109
Direct Comparison of IR and DRI Detector for HT‐GPC of Polyolefins
Summary: Molar mass distribution (MMD) of polyolefins is routinely analyzed by gel permeation chromatography (GPC), also known as size exclusion chromatography (SEC), practiced in different methods and detector systems. The filter‐based infrared detector (IR) has become a preferred alternative to the traditional use of differential refractive index detector (DRI) for high temperature GPC (HT‐GPC) when applied to polyolefins. The main reason is that a modern multiple band filter‐based IR detector can be used to determine the distribution of co‐monomer along the molar mass distribution in a copolymer, in a single HT‐GPC analysis directly without the need of additional analytical procedures. In addition to that, the performance of the modern IR detector when used as primary concentration detector in the HT‐GPC instrument, in either the single or the multiple detection schemes, proves to be superior to that of DRI detector. This is due to the high signal‐to‐noise ratio achievable by the modern IR detector and its excellent baseline stability. Such high detection quality can be attributed to the inherent robustness of IR spectroscopy against external factors such as GPC temperature and flow rate variations. The impact of that higher detection performance on the final processed analytical results of polymer MMD and molar mass averages among others, is the focus of this current investigation. Different application scenarios of industrial interest have been selected to show a direct comparison of both the IR and DRI detectors installed on a same GPC instrument.
- 15 October 2015
- Published by Wiley in Macromolecular Symposia
- Vol. 356 (1) , 95-109
Direct Comparison of IR and DRI Detector for HT‐GPC of Polyolefins
Summary: Molar mass distribution (MMD) of polyolefins is routinely analyzed by gel permeation chromatography (GPC), also known as size exclusion chromatography (SEC), practiced in different methods and detector systems. The filter‐based infrared detector (IR) has become a preferred alternative to the traditional use of differential refractive index detector (DRI) for high temperature GPC (HT‐GPC) when applied to polyolefins. The main reason is that a modern multiple band filter‐based IR detector can be used to determine the distribution of co‐monomer along the molar mass distribution in a copolymer, in a single HT‐GPC analysis directly without the need of additional analytical procedures. In addition to that, the performance of the modern IR detector when used as primary concentration detector in the HT‐GPC instrument, in either the single or the multiple detection schemes, proves to be superior to that of DRI detector. This is due to the high signal‐to‐noise ratio achievable by the modern IR detector and its excellent baseline stability. Such high detection quality can be attributed to the inherent robustness of IR spectroscopy against external factors such as GPC temperature and flow rate variations. The impact of that higher detection performance on the final processed analytical results of polymer MMD and molar mass averages among others, is the focus of this current investigation. Different application scenarios of industrial interest have been selected to show a direct comparison of both the IR and DRI detectors installed on a same GPC instrument.
- 23 August 2013
- Published by Wiley in Macromolecular Symposia
- Vol. 330 (1) , 63-80
Characterization of Chemical Composition along the Molar Mass Distribution in Polyolefin Copolymers by GPC Using a Modern Filter‐Based IR Detector
Summary: Gel permeation chromatography (GPC), also known as size exclusion chromatography (SEC), is the technique routinely used at high temperature to analyze the molar mass distribution in polyolefins. The distribution of comonomer along the molar mass distribution in a copolymer is a key microstructural feature that determines the macroscopic properties of the material, and thus, its range of possible applications and performance. The direct coupling of a modern filter‐based infrared (IR) detector to a high temperature GPC instrument, by means of a heated flow‐through cell, is here described. The analyses are carried out by recording the continuous IR absorbance chromatograms at selected bands, which show different sensitivities to the different monomer units. A slice‐by‐slice ratio of the IR bands is further calculated to determine the average chemical composition of each molar mass fraction, after GPC separation. The high sensitivity of this IR detection method allows the injection of low concentrations of sample and the use of standard GPC analysis conditions, so that chromatographic quality is not compromised even in cases where very high molar mass fractions are present. The analysis of comonomer variations along the molar mass distribution in polyolefin copolymers is discussed. Selected applications of the method to polyethylene and poly(propylene) copolymers are presented.
- 23 August 2013
- Published by Wiley in Macromolecular Symposia
- Vol. 330 (1) , 63-80
Characterization of Chemical Composition along the Molar Mass Distribution in Polyolefin Copolymers by GPC Using a Modern Filter‐Based IR Detector
Summary: Gel permeation chromatography (GPC), also known as size exclusion chromatography (SEC), is the technique routinely used at high temperature to analyze the molar mass distribution in polyolefins. The distribution of comonomer along the molar mass distribution in a copolymer is a key microstructural feature that determines the macroscopic properties of the material, and thus, its range of possible applications and performance. The direct coupling of a modern filter‐based infrared (IR) detector to a high temperature GPC instrument, by means of a heated flow‐through cell, is here described. The analyses are carried out by recording the continuous IR absorbance chromatograms at selected bands, which show different sensitivities to the different monomer units. A slice‐by‐slice ratio of the IR bands is further calculated to determine the average chemical composition of each molar mass fraction, after GPC separation. The high sensitivity of this IR detection method allows the injection of low concentrations of sample and the use of standard GPC analysis conditions, so that chromatographic quality is not compromised even in cases where very high molar mass fractions are present. The analysis of comonomer variations along the molar mass distribution in polyolefin copolymers is discussed. Selected applications of the method to polyethylene and poly(propylene) copolymers are presented.
- 27 February 2012
- Published by Wiley in Macromolecular Symposia
- Vol. 312 (1) , 157-166
A New Calibration Method for the Accurate Determination of Ethylene Content in Ethylene‐Propylene Copolymers by CRYSTEX‐IR
Summary: CRYSTEX is a fully automated instrument for the determination of Xylene Solubles in polypropylene and ethylene‐propylene copolymers, providing an excellent correlation with gravimetric methods. The instrument can be equipped with a dual band infrared (IR) detector to quantify the ethylene weight percentage (C2%) in the amorphous fraction, and in the whole polymer sample. In this work, a new approach based on multiple linear regression (MLR) models is presented, which makes use of two independent IR absorbance signals acquired simultaneously by the detector. A compromise model to predict directly C2% is proposed, which balances good accuracy and reduced experimental effort. MLR models able to predict the total sample concentration were also developed. The results were successfully validated using copolymer standards in a wide chemical composition range.
- 27 February 2012
- Published by Wiley in Macromolecular Symposia
- Vol. 312 (1) , 157-166
A New Calibration Method for the Accurate Determination of Ethylene Content in Ethylene‐Propylene Copolymers by CRYSTEX‐IR
Summary: CRYSTEX is a fully automated instrument for the determination of Xylene Solubles in polypropylene and ethylene‐propylene copolymers, providing an excellent correlation with gravimetric methods. The instrument can be equipped with a dual band infrared (IR) detector to quantify the ethylene weight percentage (C2%) in the amorphous fraction, and in the whole polymer sample. In this work, a new approach based on multiple linear regression (MLR) models is presented, which makes use of two independent IR absorbance signals acquired simultaneously by the detector. A compromise model to predict directly C2% is proposed, which balances good accuracy and reduced experimental effort. MLR models able to predict the total sample concentration were also developed. The results were successfully validated using copolymer standards in a wide chemical composition range.
- 1 August 2009
- Published by Wiley in Macromolecular Symposia
- Vol. 282 (1) , 65-70
Application of a Multiple Linear Regression Model to Fixed Bands IR Detector Data in GPC-IR Analysis of Polyolefins
- 1 August 2009
- Published by Wiley in Macromolecular Symposia
- Vol. 282 (1) , 65-70
Application of a Multiple Linear Regression Model to Fixed Bands IR Detector Data in GPC-IR Analysis of Polyolefins