TSTobias Schripp

Tobias Schripp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tobias Schripp has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Erik Uhde

    Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, 38108 Braunschweig, Germany

    4 shared publications
  • Doreen Markewitz

    Fraunhofer Wilhelm-Klauditz-Institut, Material Analysis and Indoor Chemistry, Braunschweig, Germany

    2 shared publications
  • T. Salthammer

    Department Material Analysis and Indoor Chemistry; Fraunhofer WKI; Braunschweig Germany

    2 shared publications
  • Tunga Salthammer

    Fraunhofer Wilhelm-Klauditz-Institut, Material Analysis and Indoor Chemistry, Braunschweig, Germany

    2 shared publications
  • Tunga Salthammer

    Department of Material Analysis and Indoor Chemistry Fraunhofer WKI 38108 Braunschweig Germany

    2 shared publications
  • Bettina Meyer

    Fraunhofer Wilhelm-Klauditz-Institut, Quality Assessment, Braunschweig, Germany

    1 shared publication

Latest Publications

  • Comparison of Methods for the Determination of Formaldehyde in Air

    by Ruth Giesen, Tobias Schripp, Doreen Markewitz, Bettina Meyer, Harald Schwab, Erik Uhde, Tunga Salthammer

    Different methods have been used for the determination of the amount of formaldehyde present in the air. The Hantzsch method uses derivatization with acetyl acetone, and the fluorescence signal of the resulting chromophore is highly selective for formaldehyde. The 2,4-dinitrophenylhydrazine procedure allows measuring of carbonyl compounds in combination with high-performance liquid chromatography. In contrast, the 3-methyl-2-benzothiazolonehydrazone method delivers the sum of aliphatic aldehydes, although it is reported to be selective for formaldehyde. To compare the performance of these methods, 13 samples of wooden furniture were measured. Further characterization was performed with a formaldehyde source and one oriented-strand board. As expected, the results of the 2,4-dinitrophenylhydrazine and Hantzsch methods provided excellent correlation. However, the formaldehyde concentrations obtained from the 3-methyl-2-benzothiazolonehydrazone method showed almost no correlation with the 2,4-dinitrophenylhydrazine and Hantzsch values. The results demonstrated that there was significant error in calculation with the use of the 3-methyl-2-benzothiazolonehydrazone method for determining the presence of a specific aliphatic aldehyde in a mixture of volatile organic compounds in the air. In addition, emission tests of an artificial formaldehyde source revealed excessively high concentrations of formaldehyde with the 3-methyl-2-benzothiazolonehydrazone method. Therefore, it was found that the 3-methyl-2-benzothiazolonehydrazone method was not suitable for the determination of the presence of formaldehyde in the air due to interferences of other organic compounds and systematic analytical artifacts.


  • Application of proton-transfer-reaction-mass-spectrometry for Indoor Air Quality research

    by T. Schripp, S. Etienne, C. Fauck, F. Fuhrmann, L. Märk, T. Salthammer

    In the field of Indoor Air Quality research, the measurement of volatile organic compounds (VOCs) demands instruments that are rapid, mobile, robust, highly sensitive and allow for simultaneous monitoring of multiple compounds. These instruments should also compensate for possible interferences from permanent gases and air humidity. Proton-transfer-reaction-mass-spectrometry (PTR-MS) has proved to be a valuable and promising technique that fits the mentioned requirements for a suitable online measuring device. In this study, five exemplary applications of PTR-MS are described: (i) release of paint additives during drying process, (ii) emission of VOCs from active hardcopy devices, (iii) reference material evaluation, (iv) diffusion studies, and (v) emission testing of building products. The examples are selected to illustrate possibilities and limitations of the PTR technique in this field of research. The quadruple-based PTR-QMS was able to determine the emission characteristics during the experiments, especially in case of depleting emission sources (e.g., reference material). This allows for chemometrical analysis of the measured release patterns and detection of underlying processes. However, PTR-QMS reaches a functional limit in case of compound identification. If identification of VOCs is necessary, the measurements need to be accompanied by GC/MS analytics or a PTR instrument with higher mass-resolution (e.g., PTR-TOF-MS).


  • P-231

    by Tobias Schripp, Doreen Markewitz, Erik Uhde, Tunga Salthammer

  • Top Cited Papers

    Does e-cigarette consumption cause passive vaping?

    by T. Schripp, D. Markewitz, E. Uhde, T. Salthammer

    Electronic cigarette consumption (‘vaping’) is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic compounds (VOC) and (ultra)fine particles (FP/UFP) from an e-cigarette under near-to-real-use conditions in an 8-m3 emission test chamber. Furthermore, the inhaled mixture is analyzed in small chambers. An increase in FP/UFP and VOC could be determined after the use of the e-cigarette. Prominent components in the gas-phase are 1,2-propanediol, 1,2,3-propanetriol, diacetin, flavorings, and traces of nicotine. As a consequence, ‘passive vaping’ must be expected from the consumption of e-cigarettes. Furthermore, the inhaled aerosol undergoes changes in the human lung that is assumed to be attributed to deposition and evaporation. Practical Implications The consumption of e-cigarettes marks a new source for chemical and aerosol exposure in the indoor environment. To evaluate the impact of e-cigarettes on indoor air quality and to estimate the possible effect of passive vaping, information about the chemical characteristics of the released vapor is needed.