Seyit Ahmet Akdağ
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seyit Ahmet Akdağ has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Önder Güler
Istanbul Technical University
11 shared publications - Ali Dinler
Dept. of Mathematics, Istanbul Medeniyet University, Istanbul, Turkey
1 shared publication Ebubekir Fırtın
Istanbul Technical University, Energy Institute, Ayazaga Campus, 34469 Maslak-Istanbul, Turkey
1 shared publicationEmre Yagci
Istanbul Technical University, Energy Institute, Ayazaga Campus, 34469, Maslak, Turkey
1 shared publicationG. Mihalakakou
1 shared publication- Haralambos S. Bagiorgas
Department of Environmental and Natural Resources Management, School of Engineering, University of Patras, 2 G. Seferi St., Agrinio, 30100, Greece
1 shared publication
Latest Publications
- 1 May 2018
- Published by Elsevier in Renewable Energy
- Vol. 120, 69-77
Alternative Moment Method for wind energy potential and turbine energy output estimation
- 1 May 2018
- Published by Elsevier in Renewable Energy
- Vol. 120, 69-77
Alternative Moment Method for wind energy potential and turbine energy output estimation
- 1 December 2015
- Published by Elsevier in Energy Conversion and Management
- Vol. 106, 1124-1133
A novel energy pattern factor method for wind speed distribution parameter estimation
- 1 December 2015
- Published by Elsevier in Energy Conversion and Management
- Vol. 106, 1124-1133
A novel energy pattern factor method for wind speed distribution parameter estimation
- 1 December 2013
- Published by Elsevier in Sustainable Cities and Society
- Vol. 9, 15-22
Feasibility analysis of medium-sized hotel's electrical energy consumption with hybrid systems
- 1 December 2013
- Published by Elsevier in Sustainable Cities and Society
- Vol. 9, 15-22
Feasibility analysis of medium-sized hotel's electrical energy consumption with hybrid systems
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 428-430
Wind speed extrapolation methods and their effect on energy generation estimation
Wind speed profile in the atmospheric layer is critical factor for wind turbine capacity factor estimation. Prior to the installation of wind farm, it is essential to estimate expected energy output in order to assess the economic viability of the project. Wind speeds measurements are generally carried out at 10 or 30 m whereas most turbines in commercial use at present have hub heights between 60 and 100 m. Therefore, wind speed measurements are extrapolated to the wind turbine hub height. In this paper, 16 different extrapolation methods were reviewed and compared to determine wind speed, power density and their energy generation estimation capability. Two different error analyses were used to determine the best method. Utilized wind data was gathered from Turkey for 10, 30 and 50 m.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 428-430
Wind speed extrapolation methods and their effect on energy generation estimation
Wind speed profile in the atmospheric layer is critical factor for wind turbine capacity factor estimation. Prior to the installation of wind farm, it is essential to estimate expected energy output in order to assess the economic viability of the project. Wind speeds measurements are generally carried out at 10 or 30 m whereas most turbines in commercial use at present have hub heights between 60 and 100 m. Therefore, wind speed measurements are extrapolated to the wind turbine hub height. In this paper, 16 different extrapolation methods were reviewed and compared to determine wind speed, power density and their energy generation estimation capability. Two different error analyses were used to determine the best method. Utilized wind data was gathered from Turkey for 10, 30 and 50 m.
- 1 September 2013
- Published by SAGE Publications in Energy & Environment
- Vol. 24 (6) , 999-1012
Impact of Wind Speed Measurement Resolution on Estimated Capacity Factor and Electricity Production Cost
This paper presents the results of the estimated capacity factor differences of 55 wind turbines for nine resolutions of wind speed data. It is found that the utilization of low resolution mean wind speed data for energy output estimation may cause critical errors. Since wind speed is highly variable in time, utilization of low resolution mean wind speed data inevitably leads to a smoothing of the data, thus leading a loss of information and wind characteristics. The estimated capacity factor of wind turbines and the mean power density of a region can therefore change with data resolution. Noticeable capacity factor and wind power density differences were found among different resolution data sets. Therefore, high resolution mean wind speeds should be used when evaluating the economic and technical viability of wind energy project.
- 1 September 2013
- Published by SAGE Publications in Energy & Environment
- Vol. 24 (6) , 999-1012
Impact of Wind Speed Measurement Resolution on Estimated Capacity Factor and Electricity Production Cost
This paper presents the results of the estimated capacity factor differences of 55 wind turbines for nine resolutions of wind speed data. It is found that the utilization of low resolution mean wind speed data for energy output estimation may cause critical errors. Since wind speed is highly variable in time, utilization of low resolution mean wind speed data inevitably leads to a smoothing of the data, thus leading a loss of information and wind characteristics. The estimated capacity factor of wind turbines and the mean power density of a region can therefore change with data resolution. Noticeable capacity factor and wind power density differences were found among different resolution data sets. Therefore, high resolution mean wind speeds should be used when evaluating the economic and technical viability of wind energy project.
- 12 March 2012
- Published by Taylor & Francis in Energy Sources, Part B: Economics, Planning, and Policy
- Vol. 7 (4) , 339-347
The Impact of Wind Speed Variability on Wind Power Potential and Estimated Generation Cost
Wind measurements are generally taken at hourly intervals. Since wind speed fluctuates rapidly over time, some critical errors might occur between the estimated and the actual energy output. In this study, the impact of wind speed variability on wind power potential and estimated generation cost was analyzed by using 22 years of wind data sets for two different models of wind turbines with the capacities of 1,500 kW and 2,500 kW. As a result, the differences observed in annual energy production estimation for a 1,500 kW turbine and a 2,500 kW turbine were up to 50.1% and 48.89%, respectively. Consequently, the same differences occurred between yearly energy production costs.
- 12 March 2012
- Published by Taylor & Francis in Energy Sources, Part B: Economics, Planning, and Policy
- Vol. 7 (4) , 339-347
The Impact of Wind Speed Variability on Wind Power Potential and Estimated Generation Cost
Wind measurements are generally taken at hourly intervals. Since wind speed fluctuates rapidly over time, some critical errors might occur between the estimated and the actual energy output. In this study, the impact of wind speed variability on wind power potential and estimated generation cost was analyzed by using 22 years of wind data sets for two different models of wind turbines with the capacities of 1,500 kW and 2,500 kW. As a result, the differences observed in annual energy production estimation for a 1,500 kW turbine and a 2,500 kW turbine were up to 50.1% and 48.89%, respectively. Consequently, the same differences occurred between yearly energy production costs.
- 1 November 2011
- Published by Elsevier in Applied Energy
- Vol. 88 (11) , 4097-4105
Investigation of wind shear coefficients and their effect on electrical energy generation
- 1 November 2011
- Published by Elsevier in Applied Energy
- Vol. 88 (11) , 4097-4105
Investigation of wind shear coefficients and their effect on electrical energy generation
- 1 August 2010
- Published by Elsevier in Applied Energy
- Vol. 87 (8) , 2566-2573
Use of two-component Weibull mixtures in the analysis of wind speed in the Eastern Mediterranean
- 1 August 2010
- Published by Elsevier in Applied Energy
- Vol. 87 (8) , 2566-2573
Use of two-component Weibull mixtures in the analysis of wind speed in the Eastern Mediterranean
- 1 August 2010
- Published by Elsevier in Applied Energy
- Vol. 87 (8) , 2574-2580
Evaluation of wind energy investment interest and electricity generation cost analysis for Turkey
- 1 August 2010
- Published by Elsevier in Applied Energy
- Vol. 87 (8) , 2574-2580
Evaluation of wind energy investment interest and electricity generation cost analysis for Turkey
- 19 July 2010
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 7 (4) , 422-433
Wind Characteristics Analyses and Determination of Appropriate Wind Turbine for Amasra—Black Sea Region, Turkey
In this study, wind characteristics of Amasra were analyzed with hourly wind data collected between 1997 and 2006. Wind characteristics such as monthly average mean speeds, power densities, turbulence intensities, maximum gust, and prevailing wind directions were identified. Weibull distribution model was used to determine energy output of thirty commercial wind turbines ranging from 335 to 3000 kW. Estimated mean capacity factors were calculated between 26.8% and 43.9%.
- 19 July 2010
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 7 (4) , 422-433
Wind Characteristics Analyses and Determination of Appropriate Wind Turbine for Amasra—Black Sea Region, Turkey
In this study, wind characteristics of Amasra were analyzed with hourly wind data collected between 1997 and 2006. Wind characteristics such as monthly average mean speeds, power densities, turbulence intensities, maximum gust, and prevailing wind directions were identified. Weibull distribution model was used to determine energy output of thirty commercial wind turbines ranging from 335 to 3000 kW. Estimated mean capacity factors were calculated between 26.8% and 43.9%.