RMRavi J. Menezes

Ravi J. Menezes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ravi J. Menezes has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Diagnostic Accuracy of an iPhone DICOM Viewer for the Interpretation of Magnetic Resonance Imaging of the Knee

    by Peter De Maio, Lawrence M. White, Robert Bleakney, Ravi J. Menezes, John Theodoropoulos

    To evaluate the diagnostic performance of viewing magnetic resonance (MR) images on a handheld mobile device compared with a conventional radiology workstation for the diagnosis of intra-articular knee pathology. Prospective comparison study. Tertiary care center. Fifty consecutive subjects who had MR imaging of the knee followed by knee arthroscopy were prospectively evaluated. Two musculoskeletal radiologists independently reviewed each MR study using 2 different viewers: the OsiriX DICOM viewer software on an Apple iPhone 3GS device and eFilm Workstation software on a conventional picture archiving and communications system workstation. Sensitivity and specificity of the iPhone and workstation interpretations was performed using knee arthroscopy as the reference standard. Intraobserver concordance and agreement between the iPhone and workstation interpretations were determined. There was no statistically significant difference between the 2 devices for each paired comparison of diagnostic performance. For the iPhone interpretations, sensitivity ranged from 77% (13 of 17) for the lateral meniscus to 100% (17 of 17) for the anterior cruciate ligament. Specificity ranged from 74% (14 of 19) for cartilage to 100% (50 of 50) for the posterior cruciate ligament. There was a very high level of interobserver and intraobserver agreement between devices and readers. The iPhone reads took longer than the corresponding workstation reads, with a significant mean difference between the iPhone and workstation reads of 3.98 minutes (P < 0.001). The diagnostic performance of interpreting MR images on a handheld mobile device for the assessment of intra-articular knee pathology is similar to that of a conventional radiology workstation, however, requires a longer viewing time. Timely and accurate interpretation of complex medical images using mobile device solutions could result in new workflow efficiencies and ultimately improve patient care.


  • Diffusion tensor imaging of the median nerve before and after carpal tunnel release in patients with carpal tunnel syndrome: feasibility study

    by Ali Naraghi, Lucas da Gama Lobo, Ravi Menezes, Monica Khanna, Marshall Sussman, Dimitri Anastakis, Lawrence M. White

    To evaluate diffusion tensor imaging (DTI) indices of the median nerve pre and postoperatively in patients with carpal tunnel syndrome (CTS) to determine whether indices acquired prior to surgery differ from those acquired postoperatively. Following IRB approval, ten patients with a diagnosis of CTS were prospectively recruited. Eight patients completed the study (seven women, one man). All had bilateral asymmetric symptoms, with subsequent carpal tunnel release on the more symptomatic side. DTI of both wrists were performed using single-shot spin-echo echo-planar imaging (TR/TE, 7,000/103 ms; b value 1,025 s/mm2) preoperatively, 6 weeks and 6 months after carpal tunnel release. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) of the median nerve at the level of the distal radioulnar joint and pisiform were determined by one investigator blinded to clinical data, side, and time relative to surgery. All patients had resolution of symptoms on the surgical side at 6 months. A significant increase in FA (p = 0.018) and decrease in ADC (p = 0.017) were found proximally at 6 months compared to baseline on the operative side. A significant increase in FA was observed on the operative side distally at 6 weeks (p = 0.012) and 6 months (p = 0.017). There was a significant difference in the percentage change in FA values from baseline to 6 months on the operative side in comparison with the non-operative side (p = 0.017). A significant increase in FA and decrease in ADC of the median nerve are seen following decompression surgery in patients with CTS.