Luc Salvo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Luc Salvo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
P. Lhuissier
Universite de Grenoble CNRS
2 shared publications- Yves Bréchet
SIMAP, Grenoble-INP, Saint Martin d’Hères, France
2 shared publications A. K. Dahle
University of Queensland
1 shared publication- Alexandre Fallet
Grenoble Institute of Technology-CNRS-UJF, SIMaP-GPM2, SAINT-MARTIN D'HERES, France
1 shared publication - Antoine Klos
Univ. Grenoble Alpes CNRS Grenoble INP SIMaP F-38000 Grenoble France
1 shared publication C. Le Bacq
Groupe Physique du métal, LTPCM-UMR CNRS 5614 / INPG / UJF, ENSEEG, Saint Martin d’Hères
1 shared publication
Latest Publications
- Open Access
- 1 February 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (2)
Denoising and deconvolving CT images of unknown origin: comparing linear Wiener-deconvolution with deep convolutional neural network Noise2Inverse
Low-dose CT scans are very fast, but they feature strong pixel noise which, in turn, invites for efficient denoising the same way that strong image blur invites for sharpening the images. Wiener-deconvolution serves as a starting point, combining these two operations in a linear Fourier filter. It may apply in 2D or 3D and requires merely estimates of the Signal-to-Noise Ratio SNR2 as well as the system Modulation Transfer Function (MTF). Meanwhile, any linear filter is unable to adapt to local contrast variations in the images. Therefore, convolutional neural networks (CNN) such as MSDnet or UNet can significantly improve reconstructions from low-dose CT scans thanks to their non-linear nature. The Noise2Inverse framework allows for training these CNN using a split-and-merge of two subsets generated from one raw CT dataset. This study investigates denoising by N2I with respect to the input data quality, the CNN network architecture and the fidelity of the features in the resulting denoised volume images. Unlike Wiener filtering, N2I is far more effective in removing pixel noise. Yet, these models give the vague impression that they might generate ghosts of small features (pores or spots) in the object. Image quality metrics like Fourier Shell Correlation and SNR2 power spectra show clear improvement. In particular, Noise2Inverse preserves the signal power spectrum of all scans reliably. Nevertheless, locally inspecting image features must remain a core technique when the CNN models are applied, i.e. for industrial inspection.
- 1 February 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (2)
Open AccessDenoising and deconvolving CT images of unknown origin: comparing linear Wiener-deconvolution with deep convolutional neural network Noise2Inverse
Low-dose CT scans are very fast, but they feature strong pixel noise which, in turn, invites for efficient denoising the same way that strong image blur invites for sharpening the images. Wiener-deconvolution serves as a starting point, combining these two operations in a linear Fourier filter. It may apply in 2D or 3D and requires merely estimates of the Signal-to-Noise Ratio SNR2 as well as the system Modulation Transfer Function (MTF). Meanwhile, any linear filter is unable to adapt to local contrast variations in the images. Therefore, convolutional neural networks (CNN) such as MSDnet or UNet can significantly improve reconstructions from low-dose CT scans thanks to their non-linear nature. The Noise2Inverse framework allows for training these CNN using a split-and-merge of two subsets generated from one raw CT dataset. This study investigates denoising by N2I with respect to the input data quality, the CNN network architecture and the fidelity of the features in the resulting denoised volume images. Unlike Wiener filtering, N2I is far more effective in removing pixel noise. Yet, these models give the vague impression that they might generate ghosts of small features (pores or spots) in the object. Image quality metrics like Fourier Shell Correlation and SNR2 power spectra show clear improvement. In particular, Noise2Inverse preserves the signal power spectrum of all scans reliably. Nevertheless, locally inspecting image features must remain a core technique when the CNN models are applied, i.e. for industrial inspection.
- 30 April 2013
- Published by Wiley in Advanced Engineering Materials
- Vol. 15 (8) , 767-772
Local Tomography Study of the Fracture of an ERG Metal Foam
As one of the most important analysis techniques for non‐destructive imaging, X‐ray tomography has been widely used in materials science, medical science, and industry to evaluate the behavior of porous materials. By using this method, a three dimensional volume can be inspected in order to visualize in situ the progress of damage in materials and this can be analyzed qualitatively and quantitatively. In the present study, we have used X‐ray tomography to investigate the fracture behavior of an ERG open cell aluminum foam. The process of damage development of a sample undergoing tension and the relation between the inter‐metallics and the cracks can be observed totally by the X‐ray tomography set‐up. Local tomography has in particular been used to image the microstructure at high resolution. A finite element model has also been developed in order to simulate this process of the damage using the 3D data obtained by the tomography.
- 30 April 2013
- Published by Wiley in Advanced Engineering Materials
- Vol. 15 (8) , 767-772
Local Tomography Study of the Fracture of an ERG Metal Foam
As one of the most important analysis techniques for non‐destructive imaging, X‐ray tomography has been widely used in materials science, medical science, and industry to evaluate the behavior of porous materials. By using this method, a three dimensional volume can be inspected in order to visualize in situ the progress of damage in materials and this can be analyzed qualitatively and quantitatively. In the present study, we have used X‐ray tomography to investigate the fracture behavior of an ERG open cell aluminum foam. The process of damage development of a sample undergoing tension and the relation between the inter‐metallics and the cracks can be observed totally by the X‐ray tomography set‐up. Local tomography has in particular been used to image the microstructure at high resolution. A finite element model has also been developed in order to simulate this process of the damage using the 3D data obtained by the tomography.
- 10 October 2012
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 9 (1) , 217-232
Efficient implementation of data flow graphs on multi-gpu clusters
- 10 October 2012
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 9 (1) , 217-232
Efficient implementation of data flow graphs on multi-gpu clusters
- 10 October 2012
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 65 (6) , 623-626
3D In Situ Imaging of Aluminium Alloys During Solidification
- 10 October 2012
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 65 (6) , 623-626
3D In Situ Imaging of Aluminium Alloys During Solidification
- 13 October 2010
- Published by Wiley in Journal of Applied Mechanics
- Vol. 78 (1) , 014504
Study of Thin Sandwich Beams With Steel Faces and Perforated Polymer Core in Bending Loading: Experiments and Simulations
The mechanical behavior of thin sandwich beams with steel faces and porous polymer core have been investigated using quasistatic four-points bending. Classic sandwich models predicting the behavior and the failure modes are improved to fit the particular configuration of the structure. Numerical simulations were set up in order to investigate damage at large strain. Macroscopic results are compared with analytical models and numerical simulations. Two numerical models of the core allowed confrontation of local behavior with experiments. Criteria for localization and damaging depending on core architecture are proposed.
- 13 October 2010
- Published by Wiley in Journal of Applied Mechanics
- Vol. 78 (1) , 014504
Study of Thin Sandwich Beams With Steel Faces and Perforated Polymer Core in Bending Loading: Experiments and Simulations
The mechanical behavior of thin sandwich beams with steel faces and porous polymer core have been investigated using quasistatic four-points bending. Classic sandwich models predicting the behavior and the failure modes are improved to fit the particular configuration of the structure. Numerical simulations were set up in order to investigate damage at large strain. Macroscopic results are compared with analytical models and numerical simulations. Two numerical models of the core allowed confrontation of local behavior with experiments. Criteria for localization and damaging depending on core architecture are proposed.
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1188
Metallic Sandwich Structures with Hollow Spheres Foam Core
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1188
Metallic Sandwich Structures with Hollow Spheres Foam Core
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1188
Mechanical Properties of Sintered and Non Sintered Stainless Steel Wools: Experimental Investigation and Modelling
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1188
Mechanical Properties of Sintered and Non Sintered Stainless Steel Wools: Experimental Investigation and Modelling
- 1 January 2000
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 88 (9) , 19-24
Contactless viscosity measurement by a gas film levitated droplet technique
A recently demonstrated aerodynamic levitation technique is used to perform contactless viscosity measurements. The dynamic response of a perturbed levitating droplet is presented. Classical model dealing with free oscillations and damping of droplets without gravity cannot correctly describe the correspondence between measured damping coefficient and viscosity. An energetic approach taking into account the flattened shape of the drop, the particular boundary conditions imposed by the set-up, and the velocity field of the liquid inside the drop, is introduced, leading to good agreement between experimental measurements and known viscosities of calibrated liquids. The set-up has been used to perform contactless viscosity measurement on metallic alloys in the semi-solid state (Cu-Ag, 1100 K). Résumé Une technique de lévitation de goutte sur film de gaz a été utilisée pour effectuer des mesures de viscosité sans contact. La réponse dynamique d’une goutte à des perturbations est étudiée. Les modèles classiques traitant des oscillations libres amorties de gouttes visqueuses sans gravité ne peuvent décrire correctement la relation entre le coefficient d’amortissement mesuré avec ce dispositif et la viscosité. Une approche énergétique prenant en compte la forme aplatie de la goutte, les conditions aux limites imposées par le dispositif, et le champ de vitesses à l’intérieur de la goutte permet de retrouver un bon accord entre les mesures et la viscosité de liquides calibrés. Ce dispositif a été utilisé pour faire des mesures de viscosité sans contact sur un alliage métallique à l’état semi-solide (Cu-Ag, 1100 K).
- 1 January 2000
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 88 (9) , 19-24
Contactless viscosity measurement by a gas film levitated droplet technique
A recently demonstrated aerodynamic levitation technique is used to perform contactless viscosity measurements. The dynamic response of a perturbed levitating droplet is presented. Classical model dealing with free oscillations and damping of droplets without gravity cannot correctly describe the correspondence between measured damping coefficient and viscosity. An energetic approach taking into account the flattened shape of the drop, the particular boundary conditions imposed by the set-up, and the velocity field of the liquid inside the drop, is introduced, leading to good agreement between experimental measurements and known viscosities of calibrated liquids. The set-up has been used to perform contactless viscosity measurement on metallic alloys in the semi-solid state (Cu-Ag, 1100 K). Résumé Une technique de lévitation de goutte sur film de gaz a été utilisée pour effectuer des mesures de viscosité sans contact. La réponse dynamique d’une goutte à des perturbations est étudiée. Les modèles classiques traitant des oscillations libres amorties de gouttes visqueuses sans gravité ne peuvent décrire correctement la relation entre le coefficient d’amortissement mesuré avec ce dispositif et la viscosité. Une approche énergétique prenant en compte la forme aplatie de la goutte, les conditions aux limites imposées par le dispositif, et le champ de vitesses à l’intérieur de la goutte permet de retrouver un bon accord entre les mesures et la viscosité de liquides calibrés. Ce dispositif a été utilisé pour faire des mesures de viscosité sans contact sur un alliage métallique à l’état semi-solide (Cu-Ag, 1100 K).
- 1 January 1998
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 86 (5) , 39-45
Méthodologie de présélection des procédés d’assemblage
- 1 January 1998
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 86 (5) , 39-45
Méthodologie de présélection des procédés d’assemblage