G. P. Peterson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
G. P. Peterson has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Chen Li
Department of Mechanical Engineering, University of Colorado, Boulder, CO 80309, USA
3 shared publications- Calvin Hong Li
Villanova University
2 shared publications - Chen Li
Student member of ASME
2 shared publications Ji Li
Graduate University of Chinese Academy of Sciences, Beijing, China
2 shared publicationsNikhil Koratkar
Rensselaer Polytechnic Institute, Troy, NY
2 shared publicationsCalvin H. Li
Department of Mechanical, Industrial, and Manufacturing Engineering, University of Toledo, Toledo, OH 12180
1 shared publication
Latest Publications
- 1 March 2013
- Published by American Scientific Publishers in Journal of Nanofluids
- Vol. 2 (1) , 20-24
Dual Role of Nanoparticles in the Thermal Conductivity Enhancement of Nanoparticle Suspensions
- 1 March 2013
- Published by American Scientific Publishers in Journal of Nanofluids
- Vol. 2 (1) , 20-24
Dual Role of Nanoparticles in the Thermal Conductivity Enhancement of Nanoparticle Suspensions
- 1 January 2009
- Published by ASME International
- p. 347-354
Development of a Robust Miniature Loop Heat Pipe for High Power Chip Cooling
In this work, systematic experimental and theoretical investigations were carried out on a copper-water compact loop heat pipe with a flat square evaporator having a bottom area of 30mm×30mm. Wick structure inside the evaporator was made of microscale copper powder with carefully designed vapor removal channels sintered directly on the substrate. In addition, the design and fabrication of a 120mm air-cooled condenser was given adequate consideration. From the experimental tests, it is found that such a small loop heat pipe can manage a heat load of more than 600W, and no dry-out occurs. In the favorable vertical configuration, with an air velocity of 2.8m/s, this compact loop heat pipe has a thermal resistance as low as 0.042 0C/W, with a corresponding evaporator thermal resistance as low as 0.018 0C/W.
- 1 January 2009
- Published by ASME International
- p. 347-354
Development of a Robust Miniature Loop Heat Pipe for High Power Chip Cooling
In this work, systematic experimental and theoretical investigations were carried out on a copper-water compact loop heat pipe with a flat square evaporator having a bottom area of 30mm×30mm. Wick structure inside the evaporator was made of microscale copper powder with carefully designed vapor removal channels sintered directly on the substrate. In addition, the design and fabrication of a 120mm air-cooled condenser was given adequate consideration. From the experimental tests, it is found that such a small loop heat pipe can manage a heat load of more than 600W, and no dry-out occurs. In the favorable vertical configuration, with an air velocity of 2.8m/s, this compact loop heat pipe has a thermal resistance as low as 0.042 0C/W, with a corresponding evaporator thermal resistance as low as 0.018 0C/W.
- 1 January 2009
- Published by ASME International
- p. 561-577
Characteristics of Pool Boiling Bubble Dynamics in Bead Packed Porous Structures
Spherical glass and copper beads have been used to create bead packed porous structures for an investigation of two-phase heat transfer bubble dynamics under geometric constraints. The results demonstrated a variety of bubble dynamics characteristics under a range of heating conditions. At low heat flux of 18.9 kW/m2, a single spherical bubble formed at nucleation sites of a heating surface and departed to the interstitial spaces of porous structure. When heat flux increased to 47 kW/m2, a single bubble grew into a Y shape between beads layers and connected with others to generate a horizontal vapor column. As heat flux reached 76.3 kW/m2, vertical vapor columns obtained strong momentum to form several major vapor escaping arteries, and glass beads were pushed upward by the vapor in the escaping arteries. According to Zuber’s hydrodynamics theory, choking will take place when the size of vapor columns reaches a certain value that is comparable to the critical hydrodynamic wavelength of the vapor column in plain surface pool boiling. The experimental and simulation results of this investigation illustrated that, under the geometric constrains of bead packed porous structures, similar characteristics had been induced to trigger the earlier occurrence of vapor column chocking inside porous structures. The bubble generation, growth, and detachment during the nucleate pool boiling heat transfer have been filmed, the heating surface temperatures and heat flux were recorded, and theoretical models have been employed to study bubble dynamic characteristics. Computer simulation results were combined with experimental observations to clarify the details of the vapor bubble growth process and the liquid water replenishing the inside of the porous structures. This investigation has clearly shown, with both experimental and computer simulation evidence, that the millimeter scale bead packed porous structures could greatly influence pool boiling heat transfer by forcing a single bubble to depart at a smaller size as compared to that in a plain surface situation at low heat flux situations, and could trigger the earlier occurrence of critical heat flux (CHF) by trapping the vapor into interstitial space and forming a vapor column net. The results also proved data for further development of theoretical models of pool boiling heat transfer in bead packed porous structures.
- 1 January 2009
- Published by ASME International
- p. 561-577
Characteristics of Pool Boiling Bubble Dynamics in Bead Packed Porous Structures
Spherical glass and copper beads have been used to create bead packed porous structures for an investigation of two-phase heat transfer bubble dynamics under geometric constraints. The results demonstrated a variety of bubble dynamics characteristics under a range of heating conditions. At low heat flux of 18.9 kW/m2, a single spherical bubble formed at nucleation sites of a heating surface and departed to the interstitial spaces of porous structure. When heat flux increased to 47 kW/m2, a single bubble grew into a Y shape between beads layers and connected with others to generate a horizontal vapor column. As heat flux reached 76.3 kW/m2, vertical vapor columns obtained strong momentum to form several major vapor escaping arteries, and glass beads were pushed upward by the vapor in the escaping arteries. According to Zuber’s hydrodynamics theory, choking will take place when the size of vapor columns reaches a certain value that is comparable to the critical hydrodynamic wavelength of the vapor column in plain surface pool boiling. The experimental and simulation results of this investigation illustrated that, under the geometric constrains of bead packed porous structures, similar characteristics had been induced to trigger the earlier occurrence of vapor column chocking inside porous structures. The bubble generation, growth, and detachment during the nucleate pool boiling heat transfer have been filmed, the heating surface temperatures and heat flux were recorded, and theoretical models have been employed to study bubble dynamic characteristics. Computer simulation results were combined with experimental observations to clarify the details of the vapor bubble growth process and the liquid water replenishing the inside of the porous structures. This investigation has clearly shown, with both experimental and computer simulation evidence, that the millimeter scale bead packed porous structures could greatly influence pool boiling heat transfer by forcing a single bubble to depart at a smaller size as compared to that in a plain surface situation at low heat flux situations, and could trigger the earlier occurrence of critical heat flux (CHF) by trapping the vapor into interstitial space and forming a vapor column net. The results also proved data for further development of theoretical models of pool boiling heat transfer in bead packed porous structures.
- Top Cited Papers
Nanostructured Copper Interfaces for Enhanced Boiling
- 18 March 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (4) , 042407
Transient and Steady-State Experimental Comparison Study of Effective Thermal Conductivity of Al2O3∕Water Nanofluids
Nanofluids are being studied for their potential to enhance heat transfer, which could have a significant impact on energy generation and storage systems. However, only limited experimental data on metal and metal-oxide based nanofluids, showing enhancement of the thermal conductivity, are currently available. Moreover, the majority of the data currently available have been obtained using transient methods. Some controversy exists as to the validity of the measured enhancement and the possibility that this enhancement may be an artifact of the experimental methodology. In the current investigation, Al2O3∕water nanofluids with normal diameters of 47nm at different volume fractions (0.5%, 2%, 4%, and 6%) have been investigated, using two different methodologies: a transient hot-wire method and a steady-state cut-bar method. The comparison of the measured data obtained using these two different experimental systems at room temperature was conducted and the experimental data at higher temperatures were obtained with steady-state cut-bar method and compared with previously reported data obtained using a transient hot-wire method. The arguments that the methodology is the cause of the observed enhancement of nanofluids effective thermal conductivity are evaluated and resolved. It is clear from the results that at room temperature, both the steady-state cut-bar and transient hot-wire methods result in nearly identical values for the effective thermal conductivity of the nanofluids tested, while at higher temperatures, the onset of natural convection results in larger measured effective thermal conductivities for the hot-wire method than those obtained using the steady-state cut-bar method. The experimental data at room temperature were also compared with previously reported data at room temperature and current available theoretical models, and the deviations of experimental data from the predicted values are presented and discussed.
- 18 March 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (4) , 042407
Transient and Steady-State Experimental Comparison Study of Effective Thermal Conductivity of Al2O3∕Water Nanofluids
Nanofluids are being studied for their potential to enhance heat transfer, which could have a significant impact on energy generation and storage systems. However, only limited experimental data on metal and metal-oxide based nanofluids, showing enhancement of the thermal conductivity, are currently available. Moreover, the majority of the data currently available have been obtained using transient methods. Some controversy exists as to the validity of the measured enhancement and the possibility that this enhancement may be an artifact of the experimental methodology. In the current investigation, Al2O3∕water nanofluids with normal diameters of 47nm at different volume fractions (0.5%, 2%, 4%, and 6%) have been investigated, using two different methodologies: a transient hot-wire method and a steady-state cut-bar method. The comparison of the measured data obtained using these two different experimental systems at room temperature was conducted and the experimental data at higher temperatures were obtained with steady-state cut-bar method and compared with previously reported data obtained using a transient hot-wire method. The arguments that the methodology is the cause of the observed enhancement of nanofluids effective thermal conductivity are evaluated and resolved. It is clear from the results that at room temperature, both the steady-state cut-bar and transient hot-wire methods result in nearly identical values for the effective thermal conductivity of the nanofluids tested, while at higher temperatures, the onset of natural convection results in larger measured effective thermal conductivities for the hot-wire method than those obtained using the steady-state cut-bar method. The experimental data at room temperature were also compared with previously reported data at room temperature and current available theoretical models, and the deviations of experimental data from the predicted values are presented and discussed.
- 1 January 2008
- Published by ASME International
- p. 645-650
The Visualization of Thin Film Evaporation on Thin Micro Sintered Copper Mesh Screen
The thin film evaporation process through use of thin micro-scale sintered copper mesh screen was proven to be a very effective heat transfer mechanism with high critical heat flux (CHF). This efficient heat transfer mechanism is widely used in designing heat pipe, Capillary Pumped Loops (CPL), and drying process, however, the nucleation process and meniscus dynamics at the liquid-vapor-solid interface are not directly observed and systematically studied. Very few visual investigation in thin film evaporation has been conducted. In the existing two visual studies, the interface thermal resistance between coating and the heated wall was not seriously considered, and the heat flux was limited below 35 W/cm2. In this visualization investigation, the nucleation process and meniscus dynamics from initial condition to drying out were observed and well documented. To minimize the interface thermal resistance, the micro scale wicking was sintered to heated wall directly. High quality images were acquired through a well-designed visualization system. The majority of nucleate bubbles, whose diameters are at a magnitude of 10 μm, were found to form on the top wire surfaces instead of inside the porous media at moderate heat flux. Few large size bubbles were observed to grow inside capillary wicks, however, their presence did not seem to stop the evaporation process as reported before. The menisci receding process was visually captured for the first time. The minimum menisci radius was found to form at the smallest corners and pores. It is also illustrated the thin liquid area increases when the menisci recede and the thin liquid film evaporation is the dominant heat transfer mode at high heat flux. The present work visually confirms the heat transfer regimes of evaporation on micro porous media, which was proposed by Li and Peterson [2], and further improves the understanding to the nucleate boiling and thin liquid film evaporation on the surfaces of micro sintered copper mesh screen.
- 1 January 2008
- Published by ASME International
- p. 645-650
The Visualization of Thin Film Evaporation on Thin Micro Sintered Copper Mesh Screen
The thin film evaporation process through use of thin micro-scale sintered copper mesh screen was proven to be a very effective heat transfer mechanism with high critical heat flux (CHF). This efficient heat transfer mechanism is widely used in designing heat pipe, Capillary Pumped Loops (CPL), and drying process, however, the nucleation process and meniscus dynamics at the liquid-vapor-solid interface are not directly observed and systematically studied. Very few visual investigation in thin film evaporation has been conducted. In the existing two visual studies, the interface thermal resistance between coating and the heated wall was not seriously considered, and the heat flux was limited below 35 W/cm2. In this visualization investigation, the nucleation process and meniscus dynamics from initial condition to drying out were observed and well documented. To minimize the interface thermal resistance, the micro scale wicking was sintered to heated wall directly. High quality images were acquired through a well-designed visualization system. The majority of nucleate bubbles, whose diameters are at a magnitude of 10 μm, were found to form on the top wire surfaces instead of inside the porous media at moderate heat flux. Few large size bubbles were observed to grow inside capillary wicks, however, their presence did not seem to stop the evaporation process as reported before. The menisci receding process was visually captured for the first time. The minimum menisci radius was found to form at the smallest corners and pores. It is also illustrated the thin liquid area increases when the menisci recede and the thin liquid film evaporation is the dominant heat transfer mode at high heat flux. The present work visually confirms the heat transfer regimes of evaporation on micro porous media, which was proposed by Li and Peterson [2], and further improves the understanding to the nucleate boiling and thin liquid film evaporation on the surfaces of micro sintered copper mesh screen.
- 1 January 2008
- Published by ASME International
- p. 431-436
Bubble Dynamics on Nanostructured Cu Surfaces
Nucleate boiling performance was enhanced up to an order of magnitude through direct deposition of Cu nanorods on a planar Cu surface. The methodology that enables order of magnitude improvement in boiling performance without fabricating complicated surface structures or changing the working fluid will have broad impact on metal-liquid type two-phase heat exchangers. In this study, discussion was focused on bubble dynamics on the nanostrucured Cu surfaces. We observed striking differences in bubble dynamics through nucleation boiling process for the nanostructured surface including smaller bubble diameters, higher release frequencies and nucleation site density, and large fluctuations in bubble diameter prior to release. These differences during the boiling process are responsible for the enhanced heat transfer. High quality images were captured through a well-designed visualization system, which comprises of a high-speed charge-coupled device (CCD) camera, microscope and data acquisition system. This visualization study aims to quantitatively study the bubble dynamics on the nanostructured Cu surfaces.
- 1 January 2008
- Published by ASME International
- p. 431-436
Bubble Dynamics on Nanostructured Cu Surfaces
Nucleate boiling performance was enhanced up to an order of magnitude through direct deposition of Cu nanorods on a planar Cu surface. The methodology that enables order of magnitude improvement in boiling performance without fabricating complicated surface structures or changing the working fluid will have broad impact on metal-liquid type two-phase heat exchangers. In this study, discussion was focused on bubble dynamics on the nanostrucured Cu surfaces. We observed striking differences in bubble dynamics through nucleation boiling process for the nanostructured surface including smaller bubble diameters, higher release frequencies and nucleation site density, and large fluctuations in bubble diameter prior to release. These differences during the boiling process are responsible for the enhanced heat transfer. High quality images were captured through a well-designed visualization system, which comprises of a high-speed charge-coupled device (CCD) camera, microscope and data acquisition system. This visualization study aims to quantitatively study the bubble dynamics on the nanostructured Cu surfaces.
- 10 April 2007
- Published by Wiley in Journal of Heat Transfer
- Vol. 129 (11) , 1465-1475
Parametric Study of Pool Boiling on Horizontal Highly Conductive Microporous Coated Surfaces
To better understand the mechanisms that govern the behavior of pool boiling on horizontal highly conductive microporous coated surfaces, a series of experimental investigations were designed to systematically examine the effects of the geometric dimensions (i.e., coating thickness, volumetric porosity, and pore size, as well as the surface conditions of the porous coatings) on the pool-boiling performance and characteristics. The study was conducted using saturated distilled water at atmospheric pressure (101kPa) and porous surfaces fabricated from sintered isotropic copper wire screens. For nucleate boiling on the microporous coated surfaces, two vapor ventilation modes were observed to exist: (i) upward and (ii) mainly from sideways leakage to the unsealed sides and partially from the center of porous surfaces. The ratio of the heater size to the coating thickness, the friction factor of the two-phase flow to single-phase flow inside the porous coatings, as well as the input heat flux all govern the vapor ventilation mode that occurs. In this investigation, the ratio of heater size to coating thickness varies from 3.5 to 38 in order to identify the effect of heater size on the boiling characteristics. The experimental results indicate that the boiling performance and characteristics are also strongly dependent on the volumetric porosity and mesh size, as well as the surface conditions when the heater size is given. Descriptions and discussion of the typical boiling characteristics; the progressive boiling process, from pool nucleate boiling to film boiling; and the boiling performance curves on conductive microporous coated surfaces are all systematically presented.
- 10 April 2007
- Published by Wiley in Journal of Heat Transfer
- Vol. 129 (11) , 1465-1475
Parametric Study of Pool Boiling on Horizontal Highly Conductive Microporous Coated Surfaces
To better understand the mechanisms that govern the behavior of pool boiling on horizontal highly conductive microporous coated surfaces, a series of experimental investigations were designed to systematically examine the effects of the geometric dimensions (i.e., coating thickness, volumetric porosity, and pore size, as well as the surface conditions of the porous coatings) on the pool-boiling performance and characteristics. The study was conducted using saturated distilled water at atmospheric pressure (101kPa) and porous surfaces fabricated from sintered isotropic copper wire screens. For nucleate boiling on the microporous coated surfaces, two vapor ventilation modes were observed to exist: (i) upward and (ii) mainly from sideways leakage to the unsealed sides and partially from the center of porous surfaces. The ratio of the heater size to the coating thickness, the friction factor of the two-phase flow to single-phase flow inside the porous coatings, as well as the input heat flux all govern the vapor ventilation mode that occurs. In this investigation, the ratio of heater size to coating thickness varies from 3.5 to 38 in order to identify the effect of heater size on the boiling characteristics. The experimental results indicate that the boiling performance and characteristics are also strongly dependent on the volumetric porosity and mesh size, as well as the surface conditions when the heater size is given. Descriptions and discussion of the typical boiling characteristics; the progressive boiling process, from pool nucleate boiling to film boiling; and the boiling performance curves on conductive microporous coated surfaces are all systematically presented.
- 11 January 2006
- Published by Wiley in Journal of Heat Transfer
- Vol. 128 (12) , 1320-1328
Evaporation/Boiling in Thin Capillary Wicks (II)—Effects of Volumetric Porosity and Mesh Size
Presented here is the second of a two-part investigation, designed to systematically identify and investigate the parameters affecting the evaporation from and boiling within, thin capillary wicking structures with a range of volumetric porosities and mesh sizes. The experimental studies were investigated under steady-state conditions at atmospheric pressure. Part I of the investigation described the wicking fabrication process and experimental test facility, and focused on the effects of the capillary wick thickness (ASME J. Heat Transfer., 128, pp. 1312–1319). In Part II, we examine the effects of variations in the volumetric porosity and the mesh size. The experimental results presented here indicate that the critical heat flux (CHF) was strongly dependent on both the mesh size and the volumetric porosity; while the evaporation/boiling heat transfer coefficient was significantly affected by mesh size, but not strongly dependent on the volumetric porosity. The experimental results further illustrate that the menisci at the CHF are located in the corners, formed by the wire and the heated wall and between the wires in both the vertical and horizontal directions. The minimum value of these three menisci determined the maximum capillary pressure generated through the capillary wick. The experimental results and observations are systematically presented and analyzed, and the local bubble and liquid vapor interface dynamics are examined theoretically. Based on the relative relationship between the heat flux and superheat, classic nucleate boiling theory, and the visual observations of the phase-change phenomena, as well as by combining the results obtained here with those obtained in Part I of the investigation, the evaporation/boiling heat transfer regimes in these capillary wicking structures are identified and discussed.
- 11 January 2006
- Published by Wiley in Journal of Heat Transfer
- Vol. 128 (12) , 1320-1328
Evaporation/Boiling in Thin Capillary Wicks (II)—Effects of Volumetric Porosity and Mesh Size
Presented here is the second of a two-part investigation, designed to systematically identify and investigate the parameters affecting the evaporation from and boiling within, thin capillary wicking structures with a range of volumetric porosities and mesh sizes. The experimental studies were investigated under steady-state conditions at atmospheric pressure. Part I of the investigation described the wicking fabrication process and experimental test facility, and focused on the effects of the capillary wick thickness (ASME J. Heat Transfer., 128, pp. 1312–1319). In Part II, we examine the effects of variations in the volumetric porosity and the mesh size. The experimental results presented here indicate that the critical heat flux (CHF) was strongly dependent on both the mesh size and the volumetric porosity; while the evaporation/boiling heat transfer coefficient was significantly affected by mesh size, but not strongly dependent on the volumetric porosity. The experimental results further illustrate that the menisci at the CHF are located in the corners, formed by the wire and the heated wall and between the wires in both the vertical and horizontal directions. The minimum value of these three menisci determined the maximum capillary pressure generated through the capillary wick. The experimental results and observations are systematically presented and analyzed, and the local bubble and liquid vapor interface dynamics are examined theoretically. Based on the relative relationship between the heat flux and superheat, classic nucleate boiling theory, and the visual observations of the phase-change phenomena, as well as by combining the results obtained here with those obtained in Part I of the investigation, the evaporation/boiling heat transfer regimes in these capillary wicking structures are identified and discussed.
- 11 January 2006
- Published by Wiley in Journal of Heat Transfer
- Vol. 128 (12) , 1312-1319
Evaporation/Boiling in Thin Capillary Wicks (l)—Wick Thickness Effects
Presented here is the first of a two-part investigation designed to systematically identify and investigate the parameters affecting the evaporation/boiling and critical heat flux (CHF) from thin capillary wicking structures. The evaporation/boiling heat transfer coefficient, characteristics, and CHF were investigated under steady-state conditions for a variety of capillary structures with a range of wick thicknesses, volumetric porosities, and mesh sizes. In Part I of the investigation we describe the wicking fabrication process and experimental test facility and focus on the effects of the capillary wick thickness. In Part II we examine the effects of variations in the volumetric porosity and the mesh size as well as presenting detailed discussions of the evaporation/boiling phenomena from thin capillary wicking structures. An optimal sintering process was developed and employed to fabricate the test articles, which were fabricated using multiple, uniform layers of sintered isotropic copper mesh. This process minimized the interface thermal contact resistance between the heated wall and the capillary wick, as well as enhancing the contact conditions between the layers of copper mesh. Due to the effective reduction in the thermal contact resistance between the wall and capillary wick, both the evaporation/boiling heat transfer coefficient and the critical heat flux (CHF) demonstrated dramatic improvements, with heat transfer coefficients up to 245.5kW∕m2K and CHF values in excess of 367.9W∕cm2, observed. The experimental results indicate that while the evaporation/boiling heat transfer coefficient, which increases with increasing heat flux, is only related to the exposed surface area and is not affected by the capillary wick thickness, the CHF for steady-state operation is strongly dependent on the capillary wick thickness and increases proportionally with increase in the wick thickness. In addition to these observations, the experimental tests and subsequent analysis have resulted in the development of a new evaporation/boiling curve for capillary wicking structures, which provides new physical insights into the unique nature of the evaporation/boiling process in these capillary wicking structures. Sample structures and fabrication processes, as well as the test procedures are described in detail and the experimental results and observations are systematically presented and analyzed.
- 11 January 2006
- Published by Wiley in Journal of Heat Transfer
- Vol. 128 (12) , 1312-1319
Evaporation/Boiling in Thin Capillary Wicks (l)—Wick Thickness Effects
Presented here is the first of a two-part investigation designed to systematically identify and investigate the parameters affecting the evaporation/boiling and critical heat flux (CHF) from thin capillary wicking structures. The evaporation/boiling heat transfer coefficient, characteristics, and CHF were investigated under steady-state conditions for a variety of capillary structures with a range of wick thicknesses, volumetric porosities, and mesh sizes. In Part I of the investigation we describe the wicking fabrication process and experimental test facility and focus on the effects of the capillary wick thickness. In Part II we examine the effects of variations in the volumetric porosity and the mesh size as well as presenting detailed discussions of the evaporation/boiling phenomena from thin capillary wicking structures. An optimal sintering process was developed and employed to fabricate the test articles, which were fabricated using multiple, uniform layers of sintered isotropic copper mesh. This process minimized the interface thermal contact resistance between the heated wall and the capillary wick, as well as enhancing the contact conditions between the layers of copper mesh. Due to the effective reduction in the thermal contact resistance between the wall and capillary wick, both the evaporation/boiling heat transfer coefficient and the critical heat flux (CHF) demonstrated dramatic improvements, with heat transfer coefficients up to 245.5kW∕m2K and CHF values in excess of 367.9W∕cm2, observed. The experimental results indicate that while the evaporation/boiling heat transfer coefficient, which increases with increasing heat flux, is only related to the exposed surface area and is not affected by the capillary wick thickness, the CHF for steady-state operation is strongly dependent on the capillary wick thickness and increases proportionally with increase in the wick thickness. In addition to these observations, the experimental tests and subsequent analysis have resulted in the development of a new evaporation/boiling curve for capillary wicking structures, which provides new physical insights into the unique nature of the evaporation/boiling process in these capillary wicking structures. Sample structures and fabrication processes, as well as the test procedures are described in detail and the experimental results and observations are systematically presented and analyzed.