Alexander Stahn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Stahn has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Elmarie Terblanche
Department of Sport Science, Stellenbosch University, Stellenbosch, South Africa
3 shared publications Günther Strobel
3 shared publicationsSven Grunert
Free University of Berlin
1 shared publication
Latest Publications
- 14 January 2008
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (2) , 193-203
\skew2\pdot{V}{\rm O}_{2 {\rm max}} prediction from multi-frequency bioelectrical impedance analysis
Bioelectrical impedance analysis (BIA) has been shown to be highly related to skeletal muscle mass and blood volume, both of which are important determinants of maximal oxygen uptake (VO(2max)). The aim of the present study was therefore to investigate the ability of whole-body and segmental multi-frequency BIA to improve current nonexercise VO(2max) prediction models. Data for VO(2max) (mL min(-1)), anthropometry, self-reported physical activity (PA-R) and BIA were collected in 115 men and women. Multiple linear regression analysis (MLR) was used to develop the most parsimonious prediction model. Segmental BIA was not superior to whole-body measurements. Correlation coefficients between VO(2max) and resistance indices were significantly higher at 500 kHz compared to 50 kHz (p < 0.05). Intracellular resistance index, however, showed the highest correlation with VO(2max) (r = 0.89). After adjusting for age, gender and PA-R, MLR revealed that the inclusion of intracellular resistance index was slightly, but significantly (p < 0.001), superior to models based on anthropometry. Subgroup analyses indicated that the true benefit of BIA might be most prevalent in subjects with particularly low VO(2max) (<2500 mL min(-1)). In short, whole-body BIA marginally improves the accuracy of nonexercise VO(2max) prediction models and its advantage is most pronounced in individuals with particularly low VO(2max).
- 14 January 2008
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (2) , 193-203
\skew2\pdot{V}{\rm O}_{2 {\rm max}} prediction from multi-frequency bioelectrical impedance analysis
Bioelectrical impedance analysis (BIA) has been shown to be highly related to skeletal muscle mass and blood volume, both of which are important determinants of maximal oxygen uptake (VO(2max)). The aim of the present study was therefore to investigate the ability of whole-body and segmental multi-frequency BIA to improve current nonexercise VO(2max) prediction models. Data for VO(2max) (mL min(-1)), anthropometry, self-reported physical activity (PA-R) and BIA were collected in 115 men and women. Multiple linear regression analysis (MLR) was used to develop the most parsimonious prediction model. Segmental BIA was not superior to whole-body measurements. Correlation coefficients between VO(2max) and resistance indices were significantly higher at 500 kHz compared to 50 kHz (p < 0.05). Intracellular resistance index, however, showed the highest correlation with VO(2max) (r = 0.89). After adjusting for age, gender and PA-R, MLR revealed that the inclusion of intracellular resistance index was slightly, but significantly (p < 0.001), superior to models based on anthropometry. Subgroup analyses indicated that the true benefit of BIA might be most prevalent in subjects with particularly low VO(2max) (<2500 mL min(-1)). In short, whole-body BIA marginally improves the accuracy of nonexercise VO(2max) prediction models and its advantage is most pronounced in individuals with particularly low VO(2max).
- 1 October 2007
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 103 (4) , 1428-1435
Modeling upper and lower limb muscle volume by bioelectrical impedance analysis
Most studies employing bioelectrical impedance analysis (BIA) for estimating appendicular skeletal muscle mass using descriptive BIA models rely on statistical rather than biophysical principles. The aim of the present study was to evaluate the feasibility of estimating arm and leg muscle volume (MV) based on multiple bioimpedance measurements and using a recently proposed mathematical model and to compare this technique to conventional segmental BIA at high and low frequencies. MV of the arm and leg, respectively, was determined in 15 young, healthy, active men [age 22 +/- 2 (SD) yr, total body fat 15.6 +/- 5.1%] by magnetic resonance imaging (MRI) and BIA using a conventional and new bioimpedance model. MRI-determined MV for leg and arm was 6,268 +/- 1,099 and 1,173 +/- 172 cm(3), respectively. Estimated MV by the new BIA model [leg: 6,294 +/- 1,155 cm(3) (50 kHz), 6,278 +/- 1,103 cm(3) (500 kHz); arm: 1,216 +/- 172 cm(3) (50 kHz), 1,155 +/- 157 cm(3) (500 kHz)] was not statistically different from MRI-determined MV (leg: P= 0.958; arm: P= 0.188). The new BIA model was superior to conventional BIA and performed best at 500 kHz for estimating leg MV as indicated by the lower relative total error [new: 3.6% (500 kHz), 5.2% (50 kHz); conventional: 7.6% (500 kHz) and 8.3% (50 kHz)]. In contrast, the new BIA model, both at 50 and 500 kHz, did not improve the accuracy for estimating arm MV [new: 10.8% (500 kHz), 10.6% (50 kHz); conventional: 11.8% (500 kHz), 11.4% (50 kHz)]. It was concluded that modeling of multiple BIA measurements has advantages for the determination of lower limb muscle volume in healthy, active adult men.
- 1 October 2007
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 103 (4) , 1428-1435
Modeling upper and lower limb muscle volume by bioelectrical impedance analysis
Most studies employing bioelectrical impedance analysis (BIA) for estimating appendicular skeletal muscle mass using descriptive BIA models rely on statistical rather than biophysical principles. The aim of the present study was to evaluate the feasibility of estimating arm and leg muscle volume (MV) based on multiple bioimpedance measurements and using a recently proposed mathematical model and to compare this technique to conventional segmental BIA at high and low frequencies. MV of the arm and leg, respectively, was determined in 15 young, healthy, active men [age 22 +/- 2 (SD) yr, total body fat 15.6 +/- 5.1%] by magnetic resonance imaging (MRI) and BIA using a conventional and new bioimpedance model. MRI-determined MV for leg and arm was 6,268 +/- 1,099 and 1,173 +/- 172 cm(3), respectively. Estimated MV by the new BIA model [leg: 6,294 +/- 1,155 cm(3) (50 kHz), 6,278 +/- 1,103 cm(3) (500 kHz); arm: 1,216 +/- 172 cm(3) (50 kHz), 1,155 +/- 157 cm(3) (500 kHz)] was not statistically different from MRI-determined MV (leg: P= 0.958; arm: P= 0.188). The new BIA model was superior to conventional BIA and performed best at 500 kHz for estimating leg MV as indicated by the lower relative total error [new: 3.6% (500 kHz), 5.2% (50 kHz); conventional: 7.6% (500 kHz) and 8.3% (50 kHz)]. In contrast, the new BIA model, both at 50 and 500 kHz, did not improve the accuracy for estimating arm MV [new: 10.8% (500 kHz), 10.6% (50 kHz); conventional: 11.8% (500 kHz), 11.4% (50 kHz)]. It was concluded that modeling of multiple BIA measurements has advantages for the determination of lower limb muscle volume in healthy, active adult men.
- 1 November 2005
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 96 (3) , 265-273
Estimation of maximal oxygen uptake by bioelectrical impedance analysis
Previous non-exercise models for the prediction of maximal oxygen uptake (\( \dot V{\text{O}}_{{\text{2max}}} \)) have failed to accurately discriminate cardiorespiratory fitness within large cohorts. The aim of the present study was to evaluate the feasibility of a completely indirect method for predicting \( \dot V{\text{O}}_{{\text{2max}}} \) that was based on bioelectrical impedance analysis (BIA) in 66 young, healthy fit men and women. Multiple, stepwise regression analysis was used to determine the usefulness of BIA and additional covariates to estimate \( \dot V{\text{O}}_{{\text{2max}}} \) (ml min−1). BIA was highly correlated to \( \dot V{\text{O}}_{{\text{2max}}} \) (r = 0.914; P < 0.001) and entered the regression equation first. The inclusion of gender and a physical activity rating further improved the model which accounted for 88% of the variance in \( \dot V{\text{O}}_{{\text{2max}}} \) and resulted in a relative standard error of the estimate (SEE) of 7.2%. Substantial agreement between the methods was confirmed by the fact that nearly all the differences were within ±2 SD. Furthermore, in contrast to previously published non-exercise models, no trend of a reduction in prediction accuracy with increasing \( \dot V{\text{O}}_{{\text{2max}}} \) values was apparent. It was concluded that a non-exercise model based on BIA might be a rapid and useful technique to estimate \( \dot V{\text{O}}_{{\text{2max}}} \), when a direct test does not seem feasible. However, though the present results are useful to determine the viability of the method, further refinement of the BIA approach and its validation in a large, diverse population is needed before it can be applied to the clinical and epidemiological settings.- 1 November 2005
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 96 (3) , 265-273
Estimation of maximal oxygen uptake by bioelectrical impedance analysis
Previous non-exercise models for the prediction of maximal oxygen uptake (\( \dot V{\text{O}}_{{\text{2max}}} \)) have failed to accurately discriminate cardiorespiratory fitness within large cohorts. The aim of the present study was to evaluate the feasibility of a completely indirect method for predicting \( \dot V{\text{O}}_{{\text{2max}}} \) that was based on bioelectrical impedance analysis (BIA) in 66 young, healthy fit men and women. Multiple, stepwise regression analysis was used to determine the usefulness of BIA and additional covariates to estimate \( \dot V{\text{O}}_{{\text{2max}}} \) (ml min−1). BIA was highly correlated to \( \dot V{\text{O}}_{{\text{2max}}} \) (r = 0.914; P < 0.001) and entered the regression equation first. The inclusion of gender and a physical activity rating further improved the model which accounted for 88% of the variance in \( \dot V{\text{O}}_{{\text{2max}}} \) and resulted in a relative standard error of the estimate (SEE) of 7.2%. Substantial agreement between the methods was confirmed by the fact that nearly all the differences were within ±2 SD. Furthermore, in contrast to previously published non-exercise models, no trend of a reduction in prediction accuracy with increasing \( \dot V{\text{O}}_{{\text{2max}}} \) values was apparent. It was concluded that a non-exercise model based on BIA might be a rapid and useful technique to estimate \( \dot V{\text{O}}_{{\text{2max}}} \), when a direct test does not seem feasible. However, though the present results are useful to determine the viability of the method, further refinement of the BIA approach and its validation in a large, diverse population is needed before it can be applied to the clinical and epidemiological settings.