Maria Teresa Galceran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Teresa Galceran has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Encarnación Moyano
Department of Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain
5 shared publications- Oscar Núñez
Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
5 shared publications - Hector Gallart-Ayala
Metabolomics Platform, University of Lausanne, Lausanne, Switzerland
4 shared publications E. Moyano
Department of Analytical Chemistry, Faculty of Chemistry, University of Barcelona, Av. Diagonal 647, E-08028 Barcelona, Spain
3 shared publicationsAlina Astefanei
Department of Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
1 shared publication- Alina Astefanei
Analytical Chemistry Department, University of Barcelona, Martí i Franquès 1-11, E-08028 Barcelona, Spain
1 shared publication
Latest Publications
- Open Access
- 12 April 2016
- Published by Springer Nature in BMC Genomics
- Vol. 17 (1) , 1-18
Transcriptomic and metabolomic profiling of ionic liquid stimuli unveils enhanced secondary metabolism in Aspergillus nidulans
The inherent potential of filamentous fungi, especially of Ascomycota, for producing diverse bioactive metabolites remains largely silent under standard laboratory culture conditions. Innumerable strategies have been described to trigger their production, one of the simplest being manipulation of the growth media composition. Supplementing media with ionic liquids surprisingly enhanced the diversity of extracellular metabolites generated by penicillia. This finding led us to evaluate the impact of ionic liquids’ stimuli on the fungal metabolism in Aspergillus nidulans and how it reflects on the biosynthesis of secondary metabolites (SMs). Whole transcriptional profiling showed that exposure to 0.7 M cholinium chloride or 1-ethyl-3-methylimidazolium chloride dramatically affected expression of genes encoding both primary and secondary metabolism. Both ionic liquids apparently induced stress responses and detoxification mechanisms but response profiles to each stimulus were unique. Primary metabolism was up-regulated by choline, but down-regulated by 1-ethyl-3-methylimidazolium chloride; both stimulated production of acetyl-CoA (key precursor to numerous SMs) and non proteinogenic amino acids (building blocks of bioactive classes of SMs). In total, twenty one of the sixty six described backbone genes underwent up-regulation. Accordingly, differential analysis of the fungal metabolome showed that supplementing growth media with ionic liquids resulted in ca. 40 differentially accumulated ion masses compared to control conditions. In particular, it stimulated production of monodictyphenone and orsellinic acid, otherwise cryptic. Expression levels of genes encoding corresponding polyketide biosynthetic enzymes (i.e. backbone genes) increased compared to control conditions. The corresponding metabolite extracts showed increased cell polarity modulation potential in an ex vivo whole tissue assay (The lial Live Targeted Epithelia; theLiTE™). Ionic liquids, a diverse class of chemicals composed solely of ions, can provide an unexpected means to further resolve the diversity of natural compounds, guiding discovery of fungal metabolites with clinical potential.
- 12 April 2016
- Published by Springer Nature in BMC Genomics
- Vol. 17 (1) , 1-18
Open AccessTranscriptomic and metabolomic profiling of ionic liquid stimuli unveils enhanced secondary metabolism in Aspergillus nidulans
The inherent potential of filamentous fungi, especially of Ascomycota, for producing diverse bioactive metabolites remains largely silent under standard laboratory culture conditions. Innumerable strategies have been described to trigger their production, one of the simplest being manipulation of the growth media composition. Supplementing media with ionic liquids surprisingly enhanced the diversity of extracellular metabolites generated by penicillia. This finding led us to evaluate the impact of ionic liquids’ stimuli on the fungal metabolism in Aspergillus nidulans and how it reflects on the biosynthesis of secondary metabolites (SMs). Whole transcriptional profiling showed that exposure to 0.7 M cholinium chloride or 1-ethyl-3-methylimidazolium chloride dramatically affected expression of genes encoding both primary and secondary metabolism. Both ionic liquids apparently induced stress responses and detoxification mechanisms but response profiles to each stimulus were unique. Primary metabolism was up-regulated by choline, but down-regulated by 1-ethyl-3-methylimidazolium chloride; both stimulated production of acetyl-CoA (key precursor to numerous SMs) and non proteinogenic amino acids (building blocks of bioactive classes of SMs). In total, twenty one of the sixty six described backbone genes underwent up-regulation. Accordingly, differential analysis of the fungal metabolome showed that supplementing growth media with ionic liquids resulted in ca. 40 differentially accumulated ion masses compared to control conditions. In particular, it stimulated production of monodictyphenone and orsellinic acid, otherwise cryptic. Expression levels of genes encoding corresponding polyketide biosynthetic enzymes (i.e. backbone genes) increased compared to control conditions. The corresponding metabolite extracts showed increased cell polarity modulation potential in an ex vivo whole tissue assay (The lial Live Targeted Epithelia; theLiTE™). Ionic liquids, a diverse class of chemicals composed solely of ions, can provide an unexpected means to further resolve the diversity of natural compounds, guiding discovery of fungal metabolites with clinical potential.
- Open Access
- 1 August 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1408, 197-206
Characterization of aggregates of surface modified fullerenes by asymmetrical flow field-flow fractionation with multi-angle light scattering detection
- 1 August 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1408, 197-206
Open AccessCharacterization of aggregates of surface modified fullerenes by asymmetrical flow field-flow fractionation with multi-angle light scattering detection
- Open Access
- 1 July 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 882, 1-21
Characterisation and determination of fullerenes: A critical review
- 1 July 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 882, 1-21
Open AccessCharacterisation and determination of fullerenes: A critical review
- Open Access
- 31 May 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (12) , 5316-5326
Atmospheric Pressure Photoionization Mass Spectrometry of Fullerenes
Atmospheric pressure photoionization (APPI) was evaluated for the analysis of fullerenes. An important response improvement was found when using toluene mediated APPI in negative mode if compared with other atmospheric pressure ionization (API) sources (electrospray and atmospheric pressure chemical ionization). Fullerene APPI negative mass spectra were dominated by the isotopic cluster of the molecular ion, although isotopic patterns for M+1, M+2, and M+3 ions showed higher than expected relative abundances. These discrepancies are explained by the presence of two isobaric ions, one due to 13C and the other due to the addition of hydrogen to a double bond of the fullerene structure. Triple quadrupole tandem mass spectrometry, ultrahigh resolution mass spectrometry, and accurate mass measurements were used to confirm these assignments. Additionally, cluster ions M+16 and M+32 were characterized following the same strategy. Ions due to the addition of oxygen and alkyl additions were attributed to the presence of methanol in the mobile phase. For the fast chromatographic separation of fullerenes (less than 3.5 min), a sub-2 μm C18 column and isocratic elution (toluene/methanol, 45:55 v/v) was used. Highly selective-selected ion monitoring (H-SIM) mode (mass resolving power, >12 500 fwhm) was proposed monitoring the two most intense isotope ions in the [M]−• cluster. Method limits of quantitation down to 10 pg L–1 for C60 and C70 fullerenes and between 0.75 and 5.0 ng L–1 for larger fullerenes were obtained. Finally, the ultrahigh performance liquid chromatography (UHPLC)-APPI-MS method was used to analyze fullerenes in river and pond water samples.
- 31 May 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (12) , 5316-5326
Open AccessAtmospheric Pressure Photoionization Mass Spectrometry of Fullerenes
Atmospheric pressure photoionization (APPI) was evaluated for the analysis of fullerenes. An important response improvement was found when using toluene mediated APPI in negative mode if compared with other atmospheric pressure ionization (API) sources (electrospray and atmospheric pressure chemical ionization). Fullerene APPI negative mass spectra were dominated by the isotopic cluster of the molecular ion, although isotopic patterns for M+1, M+2, and M+3 ions showed higher than expected relative abundances. These discrepancies are explained by the presence of two isobaric ions, one due to 13C and the other due to the addition of hydrogen to a double bond of the fullerene structure. Triple quadrupole tandem mass spectrometry, ultrahigh resolution mass spectrometry, and accurate mass measurements were used to confirm these assignments. Additionally, cluster ions M+16 and M+32 were characterized following the same strategy. Ions due to the addition of oxygen and alkyl additions were attributed to the presence of methanol in the mobile phase. For the fast chromatographic separation of fullerenes (less than 3.5 min), a sub-2 μm C18 column and isocratic elution (toluene/methanol, 45:55 v/v) was used. Highly selective-selected ion monitoring (H-SIM) mode (mass resolving power, >12 500 fwhm) was proposed monitoring the two most intense isotope ions in the [M]−• cluster. Method limits of quantitation down to 10 pg L–1 for C60 and C70 fullerenes and between 0.75 and 5.0 ng L–1 for larger fullerenes were obtained. Finally, the ultrahigh performance liquid chromatography (UHPLC)-APPI-MS method was used to analyze fullerenes in river and pond water samples.
- 28 December 2010
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (2) , 379-386
Hydrophilic interaction liquid chromatography/tandem mass spectrometry for the analysis of diallyldimethylammonium chloride in water
We report a selective, sensitive and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of diallyldimethylammonium chloride (DADMAC) in water. Hydrophilic interaction liquid chromatography (HILIC) was used to avoid ion‐pairing reagents, which are generally employed to retain cationic compounds. The complementary information obtained in a triple quadrupole mass spectrometer and in an ion trap Orbitrap has been used to study the fragmentation of the DADMAC cation [M] + and for the correct assignment of the products ions. The HILIC/MS/MS method developed, using electrospray ionization in positive ion mode and selected reaction monitoring (SRM) acquisition mode, led to a reliable determination and confirmation of the DADMAC cation in water samples down to 50 ng L −1 . The low detection limit achieved, in combination with the absence of matrix effects, allowed the direct analysis of samples without any pretreatment, preconcentration or clean‐up step. DADMAC was determined in samples collected in a drinking water treatment plant (DWTP) in Barcelona (Spain) and it was found in the influent at the µg L −1 level. Copyright © 2010 John Wiley & Sons, Ltd.
- 28 December 2010
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (2) , 379-386
Hydrophilic interaction liquid chromatography/tandem mass spectrometry for the analysis of diallyldimethylammonium chloride in water
We report a selective, sensitive and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of diallyldimethylammonium chloride (DADMAC) in water. Hydrophilic interaction liquid chromatography (HILIC) was used to avoid ion‐pairing reagents, which are generally employed to retain cationic compounds. The complementary information obtained in a triple quadrupole mass spectrometer and in an ion trap Orbitrap has been used to study the fragmentation of the DADMAC cation [M] + and for the correct assignment of the products ions. The HILIC/MS/MS method developed, using electrospray ionization in positive ion mode and selected reaction monitoring (SRM) acquisition mode, led to a reliable determination and confirmation of the DADMAC cation in water samples down to 50 ng L −1 . The low detection limit achieved, in combination with the absence of matrix effects, allowed the direct analysis of samples without any pretreatment, preconcentration or clean‐up step. DADMAC was determined in samples collected in a drinking water treatment plant (DWTP) in Barcelona (Spain) and it was found in the influent at the µg L −1 level. Copyright © 2010 John Wiley & Sons, Ltd.
- 23 April 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (7) , 2893-2901
Fast liquid chromatography/tandem mass spectrometry (highly selective selected reaction monitoring) for the determination of toltrazuril and its metabolites in food
In this work a fast liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method was developed for the analysis of toltrazuril, a coccidiostatic drug, and its metabolites in meat food products. The applicability of atmospheric pressure chemical ionization (APCI) and heated electrospray ionization in both positive and negative modes was studied. APCI in negative mode provided the best results and the base peak originated from the loss of CF3 (toltrazuril and toltrazuril sulfone) and CHF3• (toltrazuril sulfoxide) was used as the precursor ion in MS/MS. A fast LC separation on a C18 Fused-Core™ column was used together with the APCI-MS/MS method developed using enhanced mass resolution mode (highly selective selected reaction monitoring, H-SRM) to improve the sensitivity and selectivity for the analysis of these compounds in food samples. A simple sample treatment based on an extraction with acetonitrile and a cleanup with a C18 cartridge was used. The LC-MS/MS (H-SRM) method showed good precision (relative standard deviation lower than 10%), accuracy, and linearity and allowed the determination of these compounds in food samples down to the parts per billion level (limits of detection between 0.5 and 5 µg kg-1).
- 23 April 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (7) , 2893-2901
Fast liquid chromatography/tandem mass spectrometry (highly selective selected reaction monitoring) for the determination of toltrazuril and its metabolites in food
In this work a fast liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method was developed for the analysis of toltrazuril, a coccidiostatic drug, and its metabolites in meat food products. The applicability of atmospheric pressure chemical ionization (APCI) and heated electrospray ionization in both positive and negative modes was studied. APCI in negative mode provided the best results and the base peak originated from the loss of CF3 (toltrazuril and toltrazuril sulfone) and CHF3• (toltrazuril sulfoxide) was used as the precursor ion in MS/MS. A fast LC separation on a C18 Fused-Core™ column was used together with the APCI-MS/MS method developed using enhanced mass resolution mode (highly selective selected reaction monitoring, H-SRM) to improve the sensitivity and selectivity for the analysis of these compounds in food samples. A simple sample treatment based on an extraction with acetonitrile and a cleanup with a C18 cartridge was used. The LC-MS/MS (H-SRM) method showed good precision (relative standard deviation lower than 10%), accuracy, and linearity and allowed the determination of these compounds in food samples down to the parts per billion level (limits of detection between 0.5 and 5 µg kg-1).
- 23 March 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (21) , 3511-3518
On-line solid phase extraction fast liquid chromatography–tandem mass spectrometry for the analysis of bisphenol A and its chlorinated derivatives in water samples
- 23 March 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (21) , 3511-3518
On-line solid phase extraction fast liquid chromatography–tandem mass spectrometry for the analysis of bisphenol A and its chlorinated derivatives in water samples
- 14 April 2009
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 29 (5) , 776-805
Recent advances in mass spectrometry analysis of phenolic endocrine disruptors and related compounds
This article reviews recent literature on current methodologies based on chromatography coupled to mass spectrometry to analyze phenolic compounds with endocrine‐disrupting capabilities. For this review we chose alkylphenol ethoxylates, bisphenol A, bisphenol F, and their degradation products and halogenated derivatives, which are considered important environmental contaminants. Additionally, some related compounds such as bisphenol diglycidylethers were included. Growing attention has been paid to the mass spectrometric characterization of these compounds and the instrumentation and strategies used for their quantification and confirmation. The current use of gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS) methodologies with different mass spectrometers and ionization and monitoring modes is discussed. Practical aspects with regards to the use of these analytical techniques, such as derivatizing reagents in GC–MS, ion suppression in LC–MS, and the most problematic aspects of quantification, are included in the discussion. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:776–805, 2010
- 14 April 2009
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 29 (5) , 776-805
Recent advances in mass spectrometry analysis of phenolic endocrine disruptors and related compounds
This article reviews recent literature on current methodologies based on chromatography coupled to mass spectrometry to analyze phenolic compounds with endocrine‐disrupting capabilities. For this review we chose alkylphenol ethoxylates, bisphenol A, bisphenol F, and their degradation products and halogenated derivatives, which are considered important environmental contaminants. Additionally, some related compounds such as bisphenol diglycidylethers were included. Growing attention has been paid to the mass spectrometric characterization of these compounds and the instrumentation and strategies used for their quantification and confirmation. The current use of gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS) methodologies with different mass spectrometers and ionization and monitoring modes is discussed. Practical aspects with regards to the use of these analytical techniques, such as derivatizing reagents in GC–MS, ion suppression in LC–MS, and the most problematic aspects of quantification, are included in the discussion. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:776–805, 2010
- 27 November 2007
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (24) , 4039-4048
Liquid chromatography/multi‐stage mass spectrometry of bisphenol A and its halogenated derivatives
We report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for analyzing bisphenol A (BPA) and its halogenated derivatives. Since only tetrachlorobisphenol A and tetrabromobisphenol A (TBBPA) are commercially available, mono‐, di‐ and trichlorobisphenol A were synthesized and purified in order to be used as analytical standards. This family of compounds was studied using electrospray ionization and an ion trap mass analyzer in order to characterize the new compounds and to propose fragmentation pathways. Multi‐stage mass spectrometry was used to confirm the genealogical relationship between the ions. Some product ions were traced from MS/MS to MS 4 and the labelled compounds BPA‐ d 16 and TBBPA‐ 13 C 12 were used to assign some product ion structures. In general, the deprotonated molecule [MH] − loses a methyl and/or a halogen group during both MS/MS and MS 3 , while the neutral loss of CO was also observed in MS 3 spectra. We selected the most intense and characteristic MS/MS transitions for LC/MS/MS analysis. LC separation was performed in a reversed‐phase column; methanol/water (no additives) was used as the mobile phase in gradient elution mode; and BPA‐ d 16 was chosen as the internal standard. Solid‐phase extraction (SPE) was used to pre‐concentrate and to clean up water samples. The SPE LC/MS/MS method allows BPA and its halogenated derivatives to be detected at a few parts‐per‐billion (ppb) in surface water. Copyright © 2007 John Wiley & Sons, Ltd.
- 27 November 2007
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (24) , 4039-4048
Liquid chromatography/multi‐stage mass spectrometry of bisphenol A and its halogenated derivatives
We report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for analyzing bisphenol A (BPA) and its halogenated derivatives. Since only tetrachlorobisphenol A and tetrabromobisphenol A (TBBPA) are commercially available, mono‐, di‐ and trichlorobisphenol A were synthesized and purified in order to be used as analytical standards. This family of compounds was studied using electrospray ionization and an ion trap mass analyzer in order to characterize the new compounds and to propose fragmentation pathways. Multi‐stage mass spectrometry was used to confirm the genealogical relationship between the ions. Some product ions were traced from MS/MS to MS 4 and the labelled compounds BPA‐ d 16 and TBBPA‐ 13 C 12 were used to assign some product ion structures. In general, the deprotonated molecule [MH] − loses a methyl and/or a halogen group during both MS/MS and MS 3 , while the neutral loss of CO was also observed in MS 3 spectra. We selected the most intense and characteristic MS/MS transitions for LC/MS/MS analysis. LC separation was performed in a reversed‐phase column; methanol/water (no additives) was used as the mobile phase in gradient elution mode; and BPA‐ d 16 was chosen as the internal standard. Solid‐phase extraction (SPE) was used to pre‐concentrate and to clean up water samples. The SPE LC/MS/MS method allows BPA and its halogenated derivatives to be detected at a few parts‐per‐billion (ppb) in surface water. Copyright © 2007 John Wiley & Sons, Ltd.
- 22 May 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (11) , 1704-1713
CEC separation of heterocyclic amines using methacrylate monolithic columns
Two methacrylate‐based monolithic columns, one with a negatively charged group (sulfonic group) and another with a new monomer N,N‐dimethylamino ethyl acrylate (DMAEA), were prepared and tested for the separation of basic compounds by CEC. This new monolithic stationary phase was prepared by the in situ polymerization of DMAEA with butyl methacrylate and ethylene dimethacrylate, using a ternary porogenic solvent consisting of water, 1‐propanol and 1,4‐butanediol. The performance of this column was evaluated by means of the analysis of a family of heterocyclic amines. Separation conditions such as pH, amount of organic modifier, ionic strength and elution mode (normal or counterdirectional flow) were studied. At the optimal running electrolyte composition, and using the counterdirectional mode, symmetrical electrochromatographic peaks were obtained, with the number of theoretical plates up to 30 000 and a good resolution between closely related peaks. The 2‐acrylamido‐2‐methyl‐1‐propane‐sulfonic acid column was used for CEC‐MS, taking advantage of the compatibility of its elution mode (normal flow) with the MS coupling.
- 22 May 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (11) , 1704-1713
CEC separation of heterocyclic amines using methacrylate monolithic columns
Two methacrylate‐based monolithic columns, one with a negatively charged group (sulfonic group) and another with a new monomer N,N‐dimethylamino ethyl acrylate (DMAEA), were prepared and tested for the separation of basic compounds by CEC. This new monolithic stationary phase was prepared by the in situ polymerization of DMAEA with butyl methacrylate and ethylene dimethacrylate, using a ternary porogenic solvent consisting of water, 1‐propanol and 1,4‐butanediol. The performance of this column was evaluated by means of the analysis of a family of heterocyclic amines. Separation conditions such as pH, amount of organic modifier, ionic strength and elution mode (normal or counterdirectional flow) were studied. At the optimal running electrolyte composition, and using the counterdirectional mode, symmetrical electrochromatographic peaks were obtained, with the number of theoretical plates up to 30 000 and a good resolution between closely related peaks. The 2‐acrylamido‐2‐methyl‐1‐propane‐sulfonic acid column was used for CEC‐MS, taking advantage of the compatibility of its elution mode (normal flow) with the MS coupling.