Xavier Orlik
Research Subjects
Research Interests
Xavier Orlik has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Elise Colin-Koeniguer
ONERA -The French Aerospace Lab Paris-Saclay University Palaiseau France
7 shared publications - Aurélien Plyer
ONERA (French Aerospace Lab), DTIS (Information Processing and Systems Department), University Paris-Saclay, 91123 Palaiseau, France
4 shared publications Eric Lacot
Laboratoire de Spectrométrie Physique (UMR 5588 Université Joseph Fourier CNRS 38402 St Martin d'Hères France
4 shared publicationsAntonello De Martino
3 shared publicationsDebajyoti Upadhyay
Theoretical and Applied Optics Department ONERA 31055 Toulouse France
3 shared publications- Aurélien Plyer
ITAE Medical Research, F-31320 Péchabou, France
2 shared publications
Latest Publications
- Open Access
Laser Speckle Orthogonal Contrast Imaging Calibration by Replicating Red Blood Cell Scattering Statistics with a Moving Reference Diffuser
Recent studies have proposed improving Laser Speckle Contrast Imaging (LSCI) by using polarimetric filtering to isolate multiply scattered photons from moving red blood cells (RBCs), an approach referred to as Laser Speckle Orthogonal Contrast Imaging (LSOCI). This reliance on multiple scattering enables the development of a calibration method based on a moving reference sample, chosen to generate dynamic circular Gaussian speckle fields that replicate the statistical properties of RBC scattering in both intensity and the distribution of polarization states. Assuming that multiply scattered photons from both RBCs and the reference sample exhibit a homogeneous distribution of polarization states over the Poincaré sphere, the proposed calibration links in vivo speckle contrast reduction bijectively to an equivalent speed of the reference sample. We demonstrate that this equivalent-velocity metric yields consistent in vivo measurements across distinct instruments despite the use of different laser spectral widths, thereby providing a standardized and transferable means to quantify microcirculatory activity.
Open AccessLaser Speckle Orthogonal Contrast Imaging Calibration by Replicating Red Blood Cell Scattering Statistics with a Moving Reference Diffuser
Recent studies have proposed improving Laser Speckle Contrast Imaging (LSCI) by using polarimetric filtering to isolate multiply scattered photons from moving red blood cells (RBCs), an approach referred to as Laser Speckle Orthogonal Contrast Imaging (LSOCI). This reliance on multiple scattering enables the development of a calibration method based on a moving reference sample, chosen to generate dynamic circular Gaussian speckle fields that replicate the statistical properties of RBC scattering in both intensity and the distribution of polarization states. Assuming that multiply scattered photons from both RBCs and the reference sample exhibit a homogeneous distribution of polarization states over the Poincaré sphere, the proposed calibration links in vivo speckle contrast reduction bijectively to an equivalent speed of the reference sample. We demonstrate that this equivalent-velocity metric yields consistent in vivo measurements across distinct instruments despite the use of different laser spectral widths, thereby providing a standardized and transferable means to quantify microcirculatory activity.
- Open Access
Laser Speckle Orthogonal Contrast Imaging Calibration by Replicating Red Blood Cells Scattering Statistics with a Moving Reference Diffuser
Recent studies have proposed improving Laser Speckle Contrast Imaging (LSCI) by using polarimetric filtering to isolate multiply scattered photons from moving red blood cells (RBCs), an approach referred to as Laser Speckle Orthogonal Contrast Imaging (LSOCI). This reliance on multiple scattering enables the development of a calibration method based on a moving reference sample, chosen to generate dynamic circular Gaussian speckle fields that replicate the statistical properties of RBC scattering in both intensity and the distribution of polarization states. Assuming that multiply scattered photons from both RBCs and the reference sample exhibit a homogeneous distribution of polarization states over the Poincaré sphere, the proposed calibration links in vivo speckle contrast reduction in a bijective manner to an equivalent speed of the reference sample. We demonstrate that this equivalent-velocity metric yields consistent in vivo measurements across distinct instruments despite the use of different laser spectral widths, thereby providing a standardized and transferable means to quantify microcirculation activity.
Open AccessLaser Speckle Orthogonal Contrast Imaging Calibration by Replicating Red Blood Cells Scattering Statistics with a Moving Reference Diffuser
Recent studies have proposed improving Laser Speckle Contrast Imaging (LSCI) by using polarimetric filtering to isolate multiply scattered photons from moving red blood cells (RBCs), an approach referred to as Laser Speckle Orthogonal Contrast Imaging (LSOCI). This reliance on multiple scattering enables the development of a calibration method based on a moving reference sample, chosen to generate dynamic circular Gaussian speckle fields that replicate the statistical properties of RBC scattering in both intensity and the distribution of polarization states. Assuming that multiply scattered photons from both RBCs and the reference sample exhibit a homogeneous distribution of polarization states over the Poincaré sphere, the proposed calibration links in vivo speckle contrast reduction in a bijective manner to an equivalent speed of the reference sample. We demonstrate that this equivalent-velocity metric yields consistent in vivo measurements across distinct instruments despite the use of different laser spectral widths, thereby providing a standardized and transferable means to quantify microcirculation activity.
- Open Access
Real-Time Observations of Leaf Vitality Extinction by Dynamic Speckle Imaging
Sap flow within a leaf is a critical indicator of plant vitality and health. This paper introduces an easy-to-use, non-invasive and real-time imaging method for sap microcirculation imaging. From the coherent backscattering of light on a leaf, we show that the acquisition frequency of dynamic speckle can be linked to the microcirculation speed inside the leaf. Unlike conventional methods based on speckle contrast, which use integration times long enough to observe temporal decorrelation within a single image, our approach operates in a regime where speckle patterns appear ‘frozen’ in each frame of a given sequence. This ‘frozen’ state implies that any decorrelation of the speckle pattern within a frame is negligible. However, between successive frames, decorrelation becomes substantial, and it is this inter-frame decorrelation that enables the extraction of dynamic information. In this context, the integration time primarily influences the radiometric levels, while the frame acquisition rate emerges as the key parameter for generating activity index maps. Thus, by accessing different ranges of sap flow activity levels by varying the frame acquisition rate, we reveal, in a non-invasive way, the anatomy of the leaf’s circulatory network with unprecedented richness. We experimentally validate the ability of the method to characterize the vitality of a fig leaf in real time by observing the continuous decrease in sap circulation, first in the smaller vessels and then in the larger ones, following the cutting of the leaf over a 48 h period.
Open AccessReal-Time Observations of Leaf Vitality Extinction by Dynamic Speckle Imaging
Sap flow within a leaf is a critical indicator of plant vitality and health. This paper introduces an easy-to-use, non-invasive and real-time imaging method for sap microcirculation imaging. From the coherent backscattering of light on a leaf, we show that the acquisition frequency of dynamic speckle can be linked to the microcirculation speed inside the leaf. Unlike conventional methods based on speckle contrast, which use integration times long enough to observe temporal decorrelation within a single image, our approach operates in a regime where speckle patterns appear ‘frozen’ in each frame of a given sequence. This ‘frozen’ state implies that any decorrelation of the speckle pattern within a frame is negligible. However, between successive frames, decorrelation becomes substantial, and it is this inter-frame decorrelation that enables the extraction of dynamic information. In this context, the integration time primarily influences the radiometric levels, while the frame acquisition rate emerges as the key parameter for generating activity index maps. Thus, by accessing different ranges of sap flow activity levels by varying the frame acquisition rate, we reveal, in a non-invasive way, the anatomy of the leaf’s circulatory network with unprecedented richness. We experimentally validate the ability of the method to characterize the vitality of a fig leaf in real time by observing the continuous decrease in sap circulation, first in the smaller vessels and then in the larger ones, following the cutting of the leaf over a 48 h period.
- Open Access
Standardizing Laser Speckle Orthogonal Contrast Imaging: Achieving Reproducible Measurements across Instruments
Using two independent speckle imaging systems based on the recently published LSOCI method operating in contact mode on the skin, we assess the reproducibility of in vivo measurements and conduct an inter-instrument comparison. To this aim, we propose a calibration method to handle each imaging system as a comprehensive unit, which includes the laser source, optics, and camera. Key to our method is the introduction of a new index that quantifies the departure of the temporal contrast observed in vivo from the spatial contrast scattered from a reference static element generating a circular Gaussian speckle field. Using such near-real-time calibration method, we demonstrate that the microcirculation images produced by 2 different instruments exhibit high accuracy and stability, with microcirculation activity values in excellent agreement, thereby paving the way for clinical applications.
Open AccessStandardizing Laser Speckle Orthogonal Contrast Imaging: Achieving Reproducible Measurements across Instruments
Using two independent speckle imaging systems based on the recently published LSOCI method operating in contact mode on the skin, we assess the reproducibility of in vivo measurements and conduct an inter-instrument comparison. To this aim, we propose a calibration method to handle each imaging system as a comprehensive unit, which includes the laser source, optics, and camera. Key to our method is the introduction of a new index that quantifies the departure of the temporal contrast observed in vivo from the spatial contrast scattered from a reference static element generating a circular Gaussian speckle field. Using such near-real-time calibration method, we demonstrate that the microcirculation images produced by 2 different instruments exhibit high accuracy and stability, with microcirculation activity values in excellent agreement, thereby paving the way for clinical applications.
- Open Access
- 30 May 2024
- Published by MDPI AG in Preprints.org
Standardizing Laser Speckle Orthogonal Contrast Imaging: Achieving Reproducible Measurements Across Instruments
Using two independent speckle imaging systems based on the recently published LSOCI method operating in contact mode on the skin, we assess the reproducibility of in vivo measurements and conduct an inter-instrument comparison. To this aim, we propose a calibration method to handle each imaging system as a comprehensive unit, which includes the laser source, optics, and camera. Our experimental results demonstrate that the microcirculation images produced by both instruments exhibit high accuracy and stability, with microcirculation activity values in excellent agreement, thereby paving the way for clinical applications.
- 30 May 2024
- Published by MDPI AG in Preprints.org
Open AccessStandardizing Laser Speckle Orthogonal Contrast Imaging: Achieving Reproducible Measurements Across Instruments
Using two independent speckle imaging systems based on the recently published LSOCI method operating in contact mode on the skin, we assess the reproducibility of in vivo measurements and conduct an inter-instrument comparison. To this aim, we propose a calibration method to handle each imaging system as a comprehensive unit, which includes the laser source, optics, and camera. Our experimental results demonstrate that the microcirculation images produced by both instruments exhibit high accuracy and stability, with microcirculation activity values in excellent agreement, thereby paving the way for clinical applications.
- Open Access
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (04) , 046007-13
Imaging the vasculature of a beating heart by dynamic speckle: the challenge of a quasiperiodic motion
In vivo characterization of heart diseases benefits from various imaging techniques that use the properties of ultrasounds, x-rays, radioactivity, and magnetic resonance. They exhibit complementary advantages and the ability to reconstruct a volumetric image. The noninvasive technique of three-dimensional (3D) echocardiography is particularly suited for real-time imaging of the cardiac volume chambers and valves and is a powerful tool for evaluating congenital abnormalities. X-rays are routinely applied for imaging of coronary artery disease (CAD), either by invasive coronary angiography (ICA) or by coronary computed tomography angiography.1 Radioactivity is also used in the case of cardiac scintigraphy for myocardial perfusion imaging.2 Magnetic resonance imaging provides noninvasive anatomical and functional features, including millimeter-scale analysis of cardiac valves, ventricular volumes, and myocardial perfusion.3 Donors with extended criteria (advanced age, and cardiovascular comorbidities) are routinely allocated for heart transplantation nowadays. Severe CAD is a major determinant of primary graft failure and early death after transplantation. ICA is recommended for diagnosis of CAD in organ donors older than 55 years or in those older than 45 years with cardiovascular risk factors. However, ICA is only performed in one-third of donors at risk for CAD, mainly due to logistic reasons. Ex situ heart perfusion (ESHP) is an innovative approach to improve the preservation of the donor heart before transplantation.4,5 This method allows for continuous organ monitoring including metabolic assessment of myocardial viability. ICA is the gold standard method for CAD diagnosis because of its high contrast and spatially resolved imaging capabilities but has been poorly reported during ESHP because of potential iatrogenic concerns including myocardial edema due to accumulation of contrast agent, coronary dissection, and infection.6,7 Dang Van et al. recently reported their preliminary experience of ex situ perfusion of the donor heart in high risk transplantation.4 In this clinical series, surgeons performed a coronary angiography during ESHP. This procedure resulted in a major myocardial edema and primary graft failure after transplant. The authors stated that contrast agent used for ex situ coronary imaging was deleterious for the heart in this setting. There is, therefore, a need for an alternative safe coronary imaging protocol to discriminate donor hearts with CAD that would not be eligible for transplantation.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (04) , 046007-13
Open AccessImaging the vasculature of a beating heart by dynamic speckle: the challenge of a quasiperiodic motion
In vivo characterization of heart diseases benefits from various imaging techniques that use the properties of ultrasounds, x-rays, radioactivity, and magnetic resonance. They exhibit complementary advantages and the ability to reconstruct a volumetric image. The noninvasive technique of three-dimensional (3D) echocardiography is particularly suited for real-time imaging of the cardiac volume chambers and valves and is a powerful tool for evaluating congenital abnormalities. X-rays are routinely applied for imaging of coronary artery disease (CAD), either by invasive coronary angiography (ICA) or by coronary computed tomography angiography.1 Radioactivity is also used in the case of cardiac scintigraphy for myocardial perfusion imaging.2 Magnetic resonance imaging provides noninvasive anatomical and functional features, including millimeter-scale analysis of cardiac valves, ventricular volumes, and myocardial perfusion.3 Donors with extended criteria (advanced age, and cardiovascular comorbidities) are routinely allocated for heart transplantation nowadays. Severe CAD is a major determinant of primary graft failure and early death after transplantation. ICA is recommended for diagnosis of CAD in organ donors older than 55 years or in those older than 45 years with cardiovascular risk factors. However, ICA is only performed in one-third of donors at risk for CAD, mainly due to logistic reasons. Ex situ heart perfusion (ESHP) is an innovative approach to improve the preservation of the donor heart before transplantation.4,5 This method allows for continuous organ monitoring including metabolic assessment of myocardial viability. ICA is the gold standard method for CAD diagnosis because of its high contrast and spatially resolved imaging capabilities but has been poorly reported during ESHP because of potential iatrogenic concerns including myocardial edema due to accumulation of contrast agent, coronary dissection, and infection.6,7 Dang Van et al. recently reported their preliminary experience of ex situ perfusion of the donor heart in high risk transplantation.4 In this clinical series, surgeons performed a coronary angiography during ESHP. This procedure resulted in a major myocardial edema and primary graft failure after transplant. The authors stated that contrast agent used for ex situ coronary imaging was deleterious for the heart in this setting. There is, therefore, a need for an alternative safe coronary imaging protocol to discriminate donor hearts with CAD that would not be eligible for transplantation.
- Open Access
- 27 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (04) , 046003-12
Imaging of the skin microvascularization using spatially depolarized dynamic speckle
Human microvascularization provides nutrient and waste exchange at the cellular level. It exhibits a remarkable potential to modulate blood flow inside microvessels to adapt permanently to metabolic needs. However, we know that this capacity is altered in many diseases, such as skin cancer,1 diabetes,2,3 hypertension,4 Alzheimer’s disease,5 and even very recently SARS-COV-2.6 Thus, we expect in vivo observation of the human skin microvascularization to allow for early and reliable diagnosis. Moreover, a real-time monitoring ability could broaden the application field to flap surgery and early detection of sepsis.7 However, despite the strong therapeutic potential that could result in such observations, a real-time noninvasive, high-resolution imaging technique to visualize the skin microvascularization of the whole body remains unfulfilled. Among the main existing techniques for in vivo imaging of the vasculature, ultra-high resolution computed tomography angiography has recently reached the spatial resolution of 0.2 mm,8 but it requires ionizing radiation and contrast agents. Magnetic resonance angiography (MRA), eventually optimized with contrast agents, is typically limited to a millimeter spatial resolution.9 Photoacoustic imaging uses an optical excitation by light pulses having energy that is converted into an acoustic wave by moving scatterers. The principle relies on acoustic detection and thus limits the spatial resolution to some hundreds of microns.10 Super-resolution ultrasound imaging11 – 14 has allowed for overcoming the acoustic diffraction limit using gas-filled microbubbles providing a high echogenic contrast agent. It exhibits one of the best spatial resolutions, with a value of being recently demonstrated,14 and an achievable penetration depth of 10 mm,12 but the use of a contrast agent is inherent to the technique and is invasive. In general, purely optical imaging techniques benefit from short wavelengths that favor better spatial resolution but at the expense of smaller penetration depths. Among these techniques, optical coherence tomography15 is a depth resolved scanning imaging modality that uses low coherence interferometry. It benefits from a spatial resolution on the order of few microns and is typically limited to submillimeter penetration depth16,17 due to the inherent use of a wide optical spectrum inside which some wavelengths have reduced penetration depths. Recently, using an optical spectrum shifted to the infrared region,18 penetration depth was increased by roughly 1 mm, but spatial resolution appears to decrease rapidly with depths greater than 1 mm. OCT has broadened its application field to the imaging of blood vessels.19 This later technique, called OCTA, uses the temporal variation of the OCT signal caused mainly by moving red blood cells. OCTA is now a well-established technique in the field of ophthalmology20 – 22 and seems promising for skin characterization.23 Among the numerous modalities that emerged from OCTA, Doppler OCT24 can image both blood flow dynamic and tissue structure by combining Doppler velocimetry with OCT. In addition, speckle variance OCT25 is sensitive to flow perpendicular to the scanning beam by measuring the intensity speckle change in the OCT signal. Taking into account the vector nature of the electric field, polarization-sensitive OCT (PS-OCT) can detect the birefringent properties of the sample.26 However, the interferometric signal of the OCT is subjected to polarization-induced artifacts due to polarization mismatch between the sample and reference beams.27 This difficulty has recently been bypassed by a PS-OCT angiography system at the price of a dual-channel OCT setup.28- 27 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (04) , 046003-12
Open AccessImaging of the skin microvascularization using spatially depolarized dynamic speckle
Human microvascularization provides nutrient and waste exchange at the cellular level. It exhibits a remarkable potential to modulate blood flow inside microvessels to adapt permanently to metabolic needs. However, we know that this capacity is altered in many diseases, such as skin cancer,1 diabetes,2,3 hypertension,4 Alzheimer’s disease,5 and even very recently SARS-COV-2.6 Thus, we expect in vivo observation of the human skin microvascularization to allow for early and reliable diagnosis. Moreover, a real-time monitoring ability could broaden the application field to flap surgery and early detection of sepsis.7 However, despite the strong therapeutic potential that could result in such observations, a real-time noninvasive, high-resolution imaging technique to visualize the skin microvascularization of the whole body remains unfulfilled. Among the main existing techniques for in vivo imaging of the vasculature, ultra-high resolution computed tomography angiography has recently reached the spatial resolution of 0.2 mm,8 but it requires ionizing radiation and contrast agents. Magnetic resonance angiography (MRA), eventually optimized with contrast agents, is typically limited to a millimeter spatial resolution.9 Photoacoustic imaging uses an optical excitation by light pulses having energy that is converted into an acoustic wave by moving scatterers. The principle relies on acoustic detection and thus limits the spatial resolution to some hundreds of microns.10 Super-resolution ultrasound imaging11 – 14 has allowed for overcoming the acoustic diffraction limit using gas-filled microbubbles providing a high echogenic contrast agent. It exhibits one of the best spatial resolutions, with a value of being recently demonstrated,14 and an achievable penetration depth of 10 mm,12 but the use of a contrast agent is inherent to the technique and is invasive. In general, purely optical imaging techniques benefit from short wavelengths that favor better spatial resolution but at the expense of smaller penetration depths. Among these techniques, optical coherence tomography15 is a depth resolved scanning imaging modality that uses low coherence interferometry. It benefits from a spatial resolution on the order of few microns and is typically limited to submillimeter penetration depth16,17 due to the inherent use of a wide optical spectrum inside which some wavelengths have reduced penetration depths. Recently, using an optical spectrum shifted to the infrared region,18 penetration depth was increased by roughly 1 mm, but spatial resolution appears to decrease rapidly with depths greater than 1 mm. OCT has broadened its application field to the imaging of blood vessels.19 This later technique, called OCTA, uses the temporal variation of the OCT signal caused mainly by moving red blood cells. OCTA is now a well-established technique in the field of ophthalmology20 – 22 and seems promising for skin characterization.23 Among the numerous modalities that emerged from OCTA, Doppler OCT24 can image both blood flow dynamic and tissue structure by combining Doppler velocimetry with OCT. In addition, speckle variance OCT25 is sensitive to flow perpendicular to the scanning beam by measuring the intensity speckle change in the OCT signal. Taking into account the vector nature of the electric field, polarization-sensitive OCT (PS-OCT) can detect the birefringent properties of the sample.26 However, the interferometric signal of the OCT is subjected to polarization-induced artifacts due to polarization mismatch between the sample and reference beams.27 This difficulty has recently been bypassed by a PS-OCT angiography system at the price of a dual-channel OCT setup.28 - Open Access
- 18 April 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (9) , 9544-9555
Spectralon spatial depolarization: towards an intrinsic characterization using a novel phase shift distribution analysis
Spectralons are reference radiometric samples which exhibit a calibrated reflectance. However, in case of low reflectance samples, the degree of polarization (DOP) of scattered light is hard to characterize. Here, an accurate determination of spectralon spatial depolarization is proposed. Based on a spatially resolved polarimetric imaging system, the polarization state of the scattered light is characterized for every pixel. A statistic distribution analysis is carried out over the entire image. The relative phase shift distribution between two orthogonal components of the scattered electric field clearly exhibits a high sensitivity to the reflectance, the phase statistics following a circular Voigt profile. The intrinsic part of the spatial depolarization is demonstrated to be linked to the circular Cauchy contribution of that phase dispersion. An analytic equation is proposed to estimate the monochromatic spatially integrated DOP, as a function of the reflectance.
- 18 April 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (9) , 9544-9555
Open AccessSpectralon spatial depolarization: towards an intrinsic characterization using a novel phase shift distribution analysis
Spectralons are reference radiometric samples which exhibit a calibrated reflectance. However, in case of low reflectance samples, the degree of polarization (DOP) of scattered light is hard to characterize. Here, an accurate determination of spectralon spatial depolarization is proposed. Based on a spatially resolved polarimetric imaging system, the polarization state of the scattered light is characterized for every pixel. A statistic distribution analysis is carried out over the entire image. The relative phase shift distribution between two orthogonal components of the scattered electric field clearly exhibits a high sensitivity to the reflectance, the phase statistics following a circular Voigt profile. The intrinsic part of the spatial depolarization is demonstrated to be linked to the circular Cauchy contribution of that phase dispersion. An analytic equation is proposed to estimate the monochromatic spatially integrated DOP, as a function of the reflectance.
- Open Access
- 25 September 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (20) , 24133-24141
Polarization analysis of speckle field below its transverse correlation width : application to surface and bulk scattering
An experimental method for accurate polarimetric characterization of speckle field below its transverse correlation width is proposed. Using a polarimetric analyzer, the speckle field under investigation is probed by a set of polarimetric projections describing the full Poincaré sphere surface. Spatial polarimetric variations of the speckle field are thus observed with an accuracy of 1% for each Stokes parameter. Moreover, all the experimental data can be guaranteed by a validity criterion. Using white paper sheet and rough metal samples, the method exhibits strong potential to analyze and differentiate speckle fields generated by bulk and surface scattering.
- 25 September 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (20) , 24133-24141
Open AccessPolarization analysis of speckle field below its transverse correlation width : application to surface and bulk scattering
An experimental method for accurate polarimetric characterization of speckle field below its transverse correlation width is proposed. Using a polarimetric analyzer, the speckle field under investigation is probed by a set of polarimetric projections describing the full Poincaré sphere surface. Spatial polarimetric variations of the speckle field are thus observed with an accuracy of 1% for each Stokes parameter. Moreover, all the experimental data can be guaranteed by a validity criterion. Using white paper sheet and rough metal samples, the method exhibits strong potential to analyze and differentiate speckle fields generated by bulk and surface scattering.
- Open Access
Effect of speckle on APSCI method and Mueller Imaging
The principle of the polarimetric imaging method called APSCI (Adapted Polarization State Contrast Imaging) is to maximize the polarimetric contrast between an object and its background using specific polarization states of illumination and detection. We perform here a comparative study of the APSCI method with existing Classical Mueller Imaging(CMI) associated with polar decomposition in the presence of fully and partially polarized circular Gaussian speckle. The results show a noticeable increase of the Bhattacharyya distance used as our contrast parameter for the APSCI method, especially when the object and background exhibit several polarimetric properties simultaneously.
Open AccessEffect of speckle on APSCI method and Mueller Imaging
The principle of the polarimetric imaging method called APSCI (Adapted Polarization State Contrast Imaging) is to maximize the polarimetric contrast between an object and its background using specific polarization states of illumination and detection. We perform here a comparative study of the APSCI method with existing Classical Mueller Imaging(CMI) associated with polar decomposition in the presence of fully and partially polarized circular Gaussian speckle. The results show a noticeable increase of the Bhattacharyya distance used as our contrast parameter for the APSCI method, especially when the object and background exhibit several polarimetric properties simultaneously.