DKDetlev G. Kröger

Detlev G. Kröger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Detlev G. Kröger has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Thermoeconomic Optimization of a Solar Chimney Power Plant

    by Johannes P. Pretorius, Detlev G. Kröger

    No physical optimum solar chimney power plant exists when only regarding the dimensions of such a plant. However, if construction costs are introduced, thermoeconomically optimal plant configurations may be established. This paper investigates the thermoeconomic optimization of a large-scale solar chimney power plant. Initially, relevant dimensions are selected, which are to be optimized. An approximated cost model is then developed, giving the capacity for finding optimum plant dimensions for different cost structures. Multiple computer simulations are performed and results are compared to the approximated cost of each specific plant. Thermoeconomically optimal plant configurations are obtained.


  • Performance Trends of an Air-Cooled Steam Condenser Under Windy Conditions

    by J. A. van Rooyen, D. G. Kröger

    Air-cooled steam condensers (ACSCs) are increasingly employed to reject heat in modern power plants. Unfortunately, these cooling systems become less effective under windy conditions and when ambient temperatures are high. A better understanding of the fundamental air flow patterns about and through such ACSCs is essential if their performance is to be improved under these conditions. The present numerical study models the air flow field about and through a particular ACSC. The performance of the fans is modeled with the aid of a novel numerical approach known as the “actuator disc model.” Distorted air flow patterns that significantly reduce fan performance in certain areas and recirculatory flows that entrain hot plume air are found to be the reasons for poor ACSC performance. It is found that the reduction in fan performance is the main reason for the poor ACSC performance while recirculation of hot plume air only reduces performance by a small amount.


  • Sensitivity Analysis of the Operating and Technical Specifications of a Solar Chimney Power Plant

    by Johannes P. Pretorius, Detlev G. Kröger

    This paper conducts a sensitivity analysis on the influence of the quality, thickness, reflectance, emissivity, shape, and insulation of the collector roof glass, the cross section of the collector roof supports, various ground types, ground surface roughness, absorptivity and emissivity, turbine inlet and bracing wheel loss coefficients, and the ambient pressure and lapse rate on the performance of a large-scale (reference) solar chimney power plant. Computer simulation results indicate that collector roof insulation, emissivity and reflectance, the ambient lapse rate, and ground absorptivity and emissivity all have a major effect on the power production of such a plant.


  • Solar Chimney Power Plant Performance

    by Johannes P. Pretorius, Detlev G. Kröger

    This paper evaluates the performance of a large-scale solar chimney power plant. The study considers the performance of a particular reference plant under specified meteorological conditions at a reference location in South Africa. A computer simulation program is employed to solve the governing conservation and draught equations simultaneously. Newly developed convective heat transfer and momentum equations are included in the numerical model and multiple simulations are performed. Results indicate 24hr plant power production, while illustrating considerable daily and seasonal power output variations. It is shown that plant power production is a function of the collector roof shape and inlet height.


  • Cost optimization of cooling tower geometry

    by Johannes C. Kloppers, Detlev G. Kröger

    The geometrical dimensions of a counterflow natural draft wet-cooling tower are optimized to obtain the minimum combined operational and capital cost compounded over the economic life of the cooling tower. Wet-cooling tower performance evaluation software is employed in conjunction with an optimization algorithm to obtain the optimum cooling tower geometry. It is shown that the inlet height of the cooling tower, which primarily determines the operational cost, is the most critical parameter influencing the total operational and capital cost of a cooling tower. The effects of the diameter of the cooling tower and the volume of the concrete have a less pronounced effect on the total operational and capital cost of a cooling tower. The results of the mathematical optimization algorithm are verified by a manual investigation of the solution domain.