Jr. John M. Sharp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jr. John M. Sharp has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Craig T. Simmons
Flinders University
2 shared publications - Jennifer K. Dickinson
Conoco, Inc., Houston, Texas
1 shared publication - Marcy E. Litvak
University of Texas, Dept. of Integrative Biology, 1 University Station A6700, Austin, TX78712-0183. Biological Labs 316
1 shared publication - Nico M. Hauwert
Ph.D. aspirant, City of Austin, Watershed Protection & Development Review Dept., PO Box 1088, Austin, TX 78767, Jackson School of GeoscienCes University of Texas at Austin
1 shared publication - Thomas E. McKenna
University of Delaware
1 shared publication Thomas J. Wiles
Department of Geological Sciences, The Jackson School of Geosciences, 1 University Station, C1100, The University of Texas, Austin, TX 78712-0254
1 shared publication
Latest Publications
- 1 November 2008
- Published by Association of Environmental and Engineering Geologists in Environmental & Engineering Geoscience
- Vol. 14 (4) , 251-265
The Secondary Permeability of Impervious Cover
Impervious cover signifies buildings, roads, sidewalks, and parking lots of low permeability (assumed nearly zero), and it is a consideration in estimating aquifer recharge in urbanized areas. It is commonly assumed that increasing impervious cover decreases direct recharge from precipitation, but observations of most roads, sidewalks, or parking lots reveal abundant fractures that may permit infiltration. We estimate the secondary permeability of pavements using a double-ring infiltrometer. Linear extrapolation determines the infiltration rate as the water depth approaches zero, which is used as a hydraulic conductivity proxy. Data were collected on pavements in Austin, Texas, at fractures or expansion joints intersected along sixteen 30-meter scan lines. By dividing the sum of the discharges for each fracture by the scan-line area, we determined an equivalent-porous-media hydraulic conductivity. For discrete fractures, these ranged over three orders of magnitude from >10−2 to 10−4 to 10−6 cm/s; permeability along the scan lines tended to be dominated by a few highly conductive fractures; and hydraulic conductivity of the entire paved surface was approximately 5.9 × 10−5 cm/s. By multiplying the paved surface hydraulic conductivity by the time the surface was saturated, we estimate that 21 percent of mean annual rainfall (170 mm) is available as potential recharge. Coupled with enhanced subsurface permeability structure from the installation of utilities and reduction of vegetation and, consequently, evapotranspiration, the net effect of impervious cover on recharge is uncertain, but, in many cases, there is likely either little effect or an increase in recharge from precipitation.
- 1 November 2008
- Published by Association of Environmental and Engineering Geologists in Environmental & Engineering Geoscience
- Vol. 14 (4) , 251-265
The Secondary Permeability of Impervious Cover
Impervious cover signifies buildings, roads, sidewalks, and parking lots of low permeability (assumed nearly zero), and it is a consideration in estimating aquifer recharge in urbanized areas. It is commonly assumed that increasing impervious cover decreases direct recharge from precipitation, but observations of most roads, sidewalks, or parking lots reveal abundant fractures that may permit infiltration. We estimate the secondary permeability of pavements using a double-ring infiltrometer. Linear extrapolation determines the infiltration rate as the water depth approaches zero, which is used as a hydraulic conductivity proxy. Data were collected on pavements in Austin, Texas, at fractures or expansion joints intersected along sixteen 30-meter scan lines. By dividing the sum of the discharges for each fracture by the scan-line area, we determined an equivalent-porous-media hydraulic conductivity. For discrete fractures, these ranged over three orders of magnitude from >10−2 to 10−4 to 10−6 cm/s; permeability along the scan lines tended to be dominated by a few highly conductive fractures; and hydraulic conductivity of the entire paved surface was approximately 5.9 × 10−5 cm/s. By multiplying the paved surface hydraulic conductivity by the time the surface was saturated, we estimate that 21 percent of mean annual rainfall (170 mm) is available as potential recharge. Coupled with enhanced subsurface permeability structure from the installation of utilities and reduction of vegetation and, consequently, evapotranspiration, the net effect of impervious cover on recharge is uncertain, but, in many cases, there is likely either little effect or an increase in recharge from precipitation.
- 22 September 2005
- Published by American Society of Civil Engineers (ASCE)
Characterization and Water Balance of Internal Drainage Sinkholes
Internal drainage microbasins were found constitute 10% of the 98 square km (38 square mile) portion of the Barton Springs segment of the Balcones Fault Zone Edwards Aquifer contributing to Barton Springs. Internal drainage basins have subtle geomorphological expressions that have historically been overlooked as a major recharge source within the Barton Springs segment. Internal drainage basins can be recognized and mapped based on large solution sinkhole bowls, internal contours on surface topographic maps, aerial photos, inspection of sinkholes during and after rain events, field delineation of catchment areas with GPS, and accounts from individuals such as property owners and cave explorers. We measured water balance components within a large internal drainage basin, the 19-hectare (46-acre) Headquarter Flat Sink to more directly quantify the amount of recharge contributed from internal drainage microbasins to the Edwards Aquifer. The monitored water balance components of HQ Flat that were measured for a year period (348 days), included the discrete recharge to the cave drain, evapotranspiration flux using an eddy covariance system mounted on a 15-meter tower, and soil moisture using insitu sensors and gravimetric analysis. Over the year test period, where rainfall totaled 106 cm, 58% left as evapotranspiration, 8% recharged directly through the cave drain, and 34% recharged diffusely across the internal microbasin of the cave site. The total recharge was measured to be 42% of the rainfall within the test basin. Only the discrete recharge portion was directly measured in a second internal drainage microbasin, the 22-hectare (54-acre) Hint Ridge Cave, since June 2003. The discrete recharge from Flint Ridge Cave was measured to be 9% over the same test year. During the 348-day test period, it can be estimated that known internal drainage basins contribution comprises about 5% of the Barton Springs flow reported by the USGS of 62,297,153 m3 (2,200,003,200 ft3). The water balance data from this study shows that internal drainage basins appear to be relatively efficient in recharging runoff for a given amount of source area because: 1) they do not lose runoff to areas downstream of the Recharge Zone; 2) naturally developed channels and bowls divert runoff rapidly into the subsurface; and 3) the recharge is typically limited to intervals during and shortly after rainfall events when the humidity is near saturation and net losses to evaporation are reduced. Recharge quantity can be significantly enhanced through preservation and restoration of flow to internal drainage basin sinkholes.
- 22 September 2005
- Published by American Society of Civil Engineers (ASCE)
Characterization and Water Balance of Internal Drainage Sinkholes
Internal drainage microbasins were found constitute 10% of the 98 square km (38 square mile) portion of the Barton Springs segment of the Balcones Fault Zone Edwards Aquifer contributing to Barton Springs. Internal drainage basins have subtle geomorphological expressions that have historically been overlooked as a major recharge source within the Barton Springs segment. Internal drainage basins can be recognized and mapped based on large solution sinkhole bowls, internal contours on surface topographic maps, aerial photos, inspection of sinkholes during and after rain events, field delineation of catchment areas with GPS, and accounts from individuals such as property owners and cave explorers. We measured water balance components within a large internal drainage basin, the 19-hectare (46-acre) Headquarter Flat Sink to more directly quantify the amount of recharge contributed from internal drainage microbasins to the Edwards Aquifer. The monitored water balance components of HQ Flat that were measured for a year period (348 days), included the discrete recharge to the cave drain, evapotranspiration flux using an eddy covariance system mounted on a 15-meter tower, and soil moisture using insitu sensors and gravimetric analysis. Over the year test period, where rainfall totaled 106 cm, 58% left as evapotranspiration, 8% recharged directly through the cave drain, and 34% recharged diffusely across the internal microbasin of the cave site. The total recharge was measured to be 42% of the rainfall within the test basin. Only the discrete recharge portion was directly measured in a second internal drainage microbasin, the 22-hectare (54-acre) Hint Ridge Cave, since June 2003. The discrete recharge from Flint Ridge Cave was measured to be 9% over the same test year. During the 348-day test period, it can be estimated that known internal drainage basins contribution comprises about 5% of the Barton Springs flow reported by the USGS of 62,297,153 m3 (2,200,003,200 ft3). The water balance data from this study shows that internal drainage basins appear to be relatively efficient in recharging runoff for a given amount of source area because: 1) they do not lose runoff to areas downstream of the Recharge Zone; 2) naturally developed channels and bowls divert runoff rapidly into the subsurface; and 3) the recharge is typically limited to intervals during and shortly after rainfall events when the humidity is near saturation and net losses to evaporation are reduced. Recharge quantity can be significantly enhanced through preservation and restoration of flow to internal drainage basin sinkholes.
- 9 May 2005
- Published by Wiley in Groundwater
- Vol. 43 (3) , 457-460
The compleat Darcy: New lessons learned from the first English translation of les fontaines publiques de la Ville de Dijon
- 9 May 2005
- Published by Wiley in Groundwater
- Vol. 43 (3) , 457-460
The compleat Darcy: New lessons learned from the first English translation of les fontaines publiques de la Ville de Dijon
- 1 December 2001
- Published by American Association of Petroleum Geologists AAPG/Datapages in AAPG Bulletin
- Vol. 85 (12) , 2089-2110
Potential Salinity-Driven Free Convection in a Shale-Rich Sedimentary Basin: Example from the Gulf of Mexico Basin in South Texas
We investigate the plausibility of salinity-driven free (thermohaline) convection in sedimentary rocks of the south Texas part of the Gulf of Mexico basin using salinity data, Rayleigh number calculations, and numerical models. Previous studies speculated that free convection could account for high fluxes evidently required for diagenesis in the basin, but low-permeability shales are calculated to be a barrier to free convection. In the study area, salinity inversions occur either above or within the transition zone from hydropressures to overpressures. The positioning of brines over less saline fluids provides a significant buoyancy force. Rayleigh number calculations and numerical simulations suggest that homogeneous shaly systems are unstable near the high end of the expected ranges of shale permeability (10-15-10-16 m2). Numerical simulations show that the influx of brine into the permeable layers and permeability heterogeneity in the shales are both conducive to free convection. Simulations indicate that salinity-driven free convection can occur at lower permeabilities (10-16-10-18 m2) that may approximate the permeabilities of shales in the zone of extreme overpressures over geologic time. Simple Rayleigh numbers are inadequate to predict the occurrence of free convection in heterogeneous systems. Salinity-driven free convection at depths in some large sedimentary basins, such as the Gulf of Mexico, may be more common than expected.
- 1 December 2001
- Published by American Association of Petroleum Geologists AAPG/Datapages in AAPG Bulletin
- Vol. 85 (12) , 2089-2110
Potential Salinity-Driven Free Convection in a Shale-Rich Sedimentary Basin: Example from the Gulf of Mexico Basin in South Texas
We investigate the plausibility of salinity-driven free (thermohaline) convection in sedimentary rocks of the south Texas part of the Gulf of Mexico basin using salinity data, Rayleigh number calculations, and numerical models. Previous studies speculated that free convection could account for high fluxes evidently required for diagenesis in the basin, but low-permeability shales are calculated to be a barrier to free convection. In the study area, salinity inversions occur either above or within the transition zone from hydropressures to overpressures. The positioning of brines over less saline fluids provides a significant buoyancy force. Rayleigh number calculations and numerical simulations suggest that homogeneous shaly systems are unstable near the high end of the expected ranges of shale permeability (10-15-10-16 m2). Numerical simulations show that the influx of brine into the permeable layers and permeability heterogeneity in the shales are both conducive to free convection. Simulations indicate that salinity-driven free convection can occur at lower permeabilities (10-16-10-18 m2) that may approximate the permeabilities of shales in the zone of extreme overpressures over geologic time. Simple Rayleigh numbers are inadequate to predict the occurrence of free convection in heterogeneous systems. Salinity-driven free convection at depths in some large sedimentary basins, such as the Gulf of Mexico, may be more common than expected.