Shaum P. Bhagat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shaum P. Bhagat has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Ibrahim Qaddoumi
St. Jude Children’s Research Hospital, Memphis, Tennessee U.S.A. 38105
2 shared publicationsJianrong Wu
St. Jude Children’s Research Hospital, Memphis, Tennessee U.S.A. 38105
2 shared publications- Johnnie K. Bass
Rehabilitation Services, St Jude Children's Research Hospital, Memphis, TN
2 shared publications - Alessia Paglialonga
CNR - IEIIT, Milan, Italy
1 shared publication Anne M. Davis
Hearing Science Laboratory, School of Audiology and Speech-Language Pathology, University of Memphis, Memphis, Tennessee, USA
1 shared publicationCarlos Rodriguez-Galindo
St. Jude Children’s Research Hospital, Memphis, Tennessee
1 shared publication
Latest Publications
- 25 June 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (1) , EL33-EL39
Psychophysical auditory filter estimates reveal sharper cochlear tuning in musicians
Musicianship confers enhancements to hearing at nearly all levels of the auditory system from periphery to percept. Musicians' superior psychophysical abilities are particularly evident in spectral discrimination and noise-degraded listening tasks, achieving higher perceptual sensitivity than their nonmusician peers. Greater spectral acuity implies that musicianship may increase auditory filter selectivity. This hypothesis was directly tested by measuring both forward- and simultaneous-masked psychophysical tuning curves. Sharper filter tuning (i.e., higher Q10) was observed in musicians compared to nonmusicians. Findings suggest musicians' pervasive listening benefits may be facilitated, in part, by superior spectral processing/decomposition as early as the auditory periphery.
- 25 June 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 136 (1) , EL33-EL39
Psychophysical auditory filter estimates reveal sharper cochlear tuning in musicians
Musicianship confers enhancements to hearing at nearly all levels of the auditory system from periphery to percept. Musicians' superior psychophysical abilities are particularly evident in spectral discrimination and noise-degraded listening tasks, achieving higher perceptual sensitivity than their nonmusician peers. Greater spectral acuity implies that musicianship may increase auditory filter selectivity. This hypothesis was directly tested by measuring both forward- and simultaneous-masked psychophysical tuning curves. Sharper filter tuning (i.e., higher Q10) was observed in musicians compared to nonmusicians. Findings suggest musicians' pervasive listening benefits may be facilitated, in part, by superior spectral processing/decomposition as early as the auditory periphery.
- 1 January 2014
- Published by Elsevier in Neuroscience Letters
- Vol. 559, 132-135
Efferent-mediated reduction in cochlear gain does not alter tuning estimates from stimulus-frequency otoacoustic emission group delays
- 1 January 2014
- Published by Elsevier in Neuroscience Letters
- Vol. 559, 132-135
Efferent-mediated reduction in cochlear gain does not alter tuning estimates from stimulus-frequency otoacoustic emission group delays
- 6 November 2012
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 18 (2) , 71-82
Time-Frequency Analysis of Transient-Evoked Otoacoustic Emissions in Children Exposed to Carboplatin Chemotherapy
The aims of this study were to characterize and quantify time-frequency changes in transient-evoked otoacoustic emissions (TEOAEs) recorded in children diagnosed with retinoblastoma who were receiving carboplatin chemotherapy. A signal processing technique, the wavelet transform (WT), was used to analyze TEOAE waveforms in narrow-band frequency components. Ten children (aged 3–72 months) diagnosed with unilateral or bilateral retinoblastoma were enrolled in the study. TEOAEs were acquired from the children with linear sequences of 70 dB peak equivalent SPL clicks. After WT analysis, TEOAE energy, latency and normalized energy in the narrow-band frequency components were compared before and during carboplatin chemotherapy treatment (average dose 1693 mg/m2). On a group basis, no significant differences (p > 0.05) in the TEOAE energy, latency or normalized energy before and after carboplatin treatment were observed. There were decreases in normalized energy on an individual basis in 10 out of 18 ears in the sample. Exposure to carboplatin chemotherapy did not cause significant changes in TEOAE energy, latency and normalized energy during treatment. However, long-term monitoring of hearing with measurements of TEOAEs is warranted, given the risks of delayed hearing loss in some children receiving carboplatin chemotherapy.
- 6 November 2012
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 18 (2) , 71-82
Time-Frequency Analysis of Transient-Evoked Otoacoustic Emissions in Children Exposed to Carboplatin Chemotherapy
The aims of this study were to characterize and quantify time-frequency changes in transient-evoked otoacoustic emissions (TEOAEs) recorded in children diagnosed with retinoblastoma who were receiving carboplatin chemotherapy. A signal processing technique, the wavelet transform (WT), was used to analyze TEOAE waveforms in narrow-band frequency components. Ten children (aged 3–72 months) diagnosed with unilateral or bilateral retinoblastoma were enrolled in the study. TEOAEs were acquired from the children with linear sequences of 70 dB peak equivalent SPL clicks. After WT analysis, TEOAE energy, latency and normalized energy in the narrow-band frequency components were compared before and during carboplatin chemotherapy treatment (average dose 1693 mg/m2). On a group basis, no significant differences (p > 0.05) in the TEOAE energy, latency or normalized energy before and after carboplatin treatment were observed. There were decreases in normalized energy on an individual basis in 10 out of 18 ears in the sample. Exposure to carboplatin chemotherapy did not cause significant changes in TEOAE energy, latency and normalized energy during treatment. However, long-term monitoring of hearing with measurements of TEOAEs is warranted, given the risks of delayed hearing loss in some children receiving carboplatin chemotherapy.
- 19 November 2010
- Published by Elsevier in Neuroscience Letters
- Vol. 485 (2) , 94-97
Efferent-induced change in human cochlear compression and its influence on masking of tones
- 19 November 2010
- Published by Elsevier in Neuroscience Letters
- Vol. 485 (2) , 94-97
Efferent-induced change in human cochlear compression and its influence on masking of tones
- 1 October 2010
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 74 (10) , 1156-1163
Monitoring carboplatin ototoxicity with distortion-product otoacoustic emissions in children with retinoblastoma
- 1 October 2010
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 74 (10) , 1156-1163
Monitoring carboplatin ototoxicity with distortion-product otoacoustic emissions in children with retinoblastoma
- 1 June 2009
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 18 (1) , 60-68
Analysis of Distortion Product Otoacoustic Emission Spectra in Normal-Hearing Adults
Purpose: To evaluate the ability of distortion product otoacoustic emission (DPOAE) spectral characteristics to distinguish between ears with variable hearing sensitivity within the normal range. Method: Distortion product grams (DP-grams) were acquired with primary tones decremented in 1/8-octave steps and primary-tone levels presented at 65 dB SPL (L1) and 45 dB SPL (L2) across an f2 frequency range of 842–7996 Hz from 22 normal-hearing adults (44 ears). Hearing thresholds of ears classified in Group A ( n = 22) were better than ears classified in Group B ( n = 22). Examined parameters of the DP-grams included spectral peak occurrence, peak height, peak width, and DPOAE levels. Analyses of variance were conducted to determine whether DP-gram parameters differed between Group A and Group B. Results: For the low-resolution DP-grams examined in this study, no significant between-group differences in peak occurrence, peak height, and peak width were observed. DPOAE levels were significantly higher in ears classified in Group A compared with ears classified in Group B in individuals with symmetrical hearing. Conclusions: Although spectral peaks are evident in DP-grams acquired with low resolution of the primary tones, DPOAE levels are more effective in distinguishing ears with greater hearing sensitivity from less sensitive ears.
- 1 June 2009
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 18 (1) , 60-68
Analysis of Distortion Product Otoacoustic Emission Spectra in Normal-Hearing Adults
Purpose: To evaluate the ability of distortion product otoacoustic emission (DPOAE) spectral characteristics to distinguish between ears with variable hearing sensitivity within the normal range. Method: Distortion product grams (DP-grams) were acquired with primary tones decremented in 1/8-octave steps and primary-tone levels presented at 65 dB SPL (L1) and 45 dB SPL (L2) across an f2 frequency range of 842–7996 Hz from 22 normal-hearing adults (44 ears). Hearing thresholds of ears classified in Group A ( n = 22) were better than ears classified in Group B ( n = 22). Examined parameters of the DP-grams included spectral peak occurrence, peak height, peak width, and DPOAE levels. Analyses of variance were conducted to determine whether DP-gram parameters differed between Group A and Group B. Results: For the low-resolution DP-grams examined in this study, no significant between-group differences in peak occurrence, peak height, and peak width were observed. DPOAE levels were significantly higher in ears classified in Group A compared with ears classified in Group B in individuals with symmetrical hearing. Conclusions: Although spectral peaks are evident in DP-grams acquired with low resolution of the primary tones, DPOAE levels are more effective in distinguishing ears with greater hearing sensitivity from less sensitive ears.
- 1 February 2008
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 19 (2) , 101-119
The Effects of Monotic and Dichotic Interference Tones on 40 Hz Auditory Steady-State Responses in Normal-Hearing Adults
Auditory steady-state responses (ASSRs) recorded with simultaneous presentation of multiple tones modulated from 77–105 Hz exhibit frequency specificity and can be acquired with monotic or dichotic stimulation. This study examined the frequency specificity and dichotic characteristics of 40 Hz ASSRs recorded with amplitude-modulated (AM) probe tones and unmodulated (UM) or AM interfering tones in 27 normal-hearing adults. The effects on ASSR amplitudes of monotically or dichotically presented interfering tones of various frequency, modulation depth, and modulation rate were studied. Significant decreases in ASSR amplitudes occurred when the UM interfering tone was monotic, higher in frequency, and approximately within an octave of the probe tone. ASSR amplitudes were also reduced when the AM interfering tone was monotic and modulated at a lower depth and was an octave above the probe tone. Probe and interfering AM tones modulated at different rates produced similar reductions in amplitude for ASSRs acquired with monotic and dichotic stimulation. The findings of this study contribute to clarifying the carrier and temporal envelope interactions between tonal stimuli. Description of the effects of these stimulus parameters on 40 Hz ASSRs can benefit clinical applications of this technique, including evaluating auditory function in adults not capable of participating in behavioral audiometric tests. Las respuestas auditivas de estado estable (ASSR) registradas con una presentación simultánea de múltiples tonos modulados desde 77 a 105 Hz, exhiben especificidad frecuencial y puede ser adquiridas con estimulación monótica o dicótica. Este estudio examinó la especificidad frecuencial y las características dicóticas de las ASSR de 40 Hz registradas con sondas de prueba de amplitud modulada (AM) y con tonos de interferencia no modulados (UM), en 27 sujetos adultos normoyentes. Se estudiaron los efectos sobre las amplitudes de las ASSR producto de tonos de interferencia presentados en forma monótica o dicótica, caracterizados por diferentes frecuencias, profundidades de modulación y tasa de modulación. Ocurrieron reducciones significativas en la amplitud de las ASSR cuando el tono de interferencia UM era monótico, de frecuencia mayor, y aproximadamente dentro de una octava del tono de prueba. Las amplitudes de las ASSR también se redujeron cuando el tono de interferencia de AM era monótico y modulado a una profundidad menor y a una octava por encima del tono de prueba. Los tonos de prueba y de interferencia con AM, modulados a diferentes tasas, produjeron reducciones similares en la amplitud de las ASSR, cuando se lograban con estimulación monótica o dicótica. Los hallazgos de este estudio contribuyen a aclarar las interacciones con la envolvente temporal y la del portador, entre estímulos tonales. La descripción de los efectos de estos parámetros del estímulo sobre las ASSR de 40 Hz pueden beneficiar la aplicación clínica de esta técnica, incluyendo la evaluación de funciones auditivas en adultos no capaces de participar en pruebas audiométricas conductuales.
- 1 February 2008
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 19 (2) , 101-119
The Effects of Monotic and Dichotic Interference Tones on 40 Hz Auditory Steady-State Responses in Normal-Hearing Adults
Auditory steady-state responses (ASSRs) recorded with simultaneous presentation of multiple tones modulated from 77–105 Hz exhibit frequency specificity and can be acquired with monotic or dichotic stimulation. This study examined the frequency specificity and dichotic characteristics of 40 Hz ASSRs recorded with amplitude-modulated (AM) probe tones and unmodulated (UM) or AM interfering tones in 27 normal-hearing adults. The effects on ASSR amplitudes of monotically or dichotically presented interfering tones of various frequency, modulation depth, and modulation rate were studied. Significant decreases in ASSR amplitudes occurred when the UM interfering tone was monotic, higher in frequency, and approximately within an octave of the probe tone. ASSR amplitudes were also reduced when the AM interfering tone was monotic and modulated at a lower depth and was an octave above the probe tone. Probe and interfering AM tones modulated at different rates produced similar reductions in amplitude for ASSRs acquired with monotic and dichotic stimulation. The findings of this study contribute to clarifying the carrier and temporal envelope interactions between tonal stimuli. Description of the effects of these stimulus parameters on 40 Hz ASSRs can benefit clinical applications of this technique, including evaluating auditory function in adults not capable of participating in behavioral audiometric tests. Las respuestas auditivas de estado estable (ASSR) registradas con una presentación simultánea de múltiples tonos modulados desde 77 a 105 Hz, exhiben especificidad frecuencial y puede ser adquiridas con estimulación monótica o dicótica. Este estudio examinó la especificidad frecuencial y las características dicóticas de las ASSR de 40 Hz registradas con sondas de prueba de amplitud modulada (AM) y con tonos de interferencia no modulados (UM), en 27 sujetos adultos normoyentes. Se estudiaron los efectos sobre las amplitudes de las ASSR producto de tonos de interferencia presentados en forma monótica o dicótica, caracterizados por diferentes frecuencias, profundidades de modulación y tasa de modulación. Ocurrieron reducciones significativas en la amplitud de las ASSR cuando el tono de interferencia UM era monótico, de frecuencia mayor, y aproximadamente dentro de una octava del tono de prueba. Las amplitudes de las ASSR también se redujeron cuando el tono de interferencia de AM era monótico y modulado a una profundidad menor y a una octava por encima del tono de prueba. Los tonos de prueba y de interferencia con AM, modulados a diferentes tasas, produjeron reducciones similares en la amplitud de las ASSR, cuando se lograban con estimulación monótica o dicótica. Los hallazgos de este estudio contribuyen a aclarar las interacciones con la envolvente temporal y la del portador, entre estímulos tonales. La descripción de los efectos de estos parámetros del estímulo sobre las ASSR de 40 Hz pueden beneficiar la aplicación clínica de esta técnica, incluyendo la evaluación de funciones auditivas en adultos no capaces de participar en pruebas audiométricas conductuales.
- 1 January 2008
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 47 (12) , 751-760
Modification of otoacoustic emissions following ear-level exposure to MP3 player music
The purpose of this study was to examine if a pre-determined exposure level and duration of MP3 player music would result in significant changes in cochlear function when measured with audiometric and physiological methods. Distortion-product otoacoustic emissions (DPOAEs), synchronized spontaneous otoacoustic emissions (SSOAEs), and hearing thresholds were measured in 20 normal-hearing adults before and after a 30-minute MP3 player music exposure. DPOAEs were acquired with 65/45 dB SPL primary tones (f2=0.842–7.996 kHz) with a frequency resolution of 8 points/octave. A probe microphone system recorded ear-canal music levels and was used to equalize levels at approximately 85 dBC across individuals during the music presentation. Comparison of pre- and post-exposure measurements revealed no significant differences in hearing thresholds, but DPOAE levels in half-octave bands centered from 1.4–6.0 kHz were significantly reduced following the music exposure. Post-exposure shifts in SSOAE frequency and level were highly variable in individuals identified with SSOAEs. The results for the exposure conditions explored in this study indicate that changes in otoacoustic emissions may precede the development of music-induced hearing threshold shifts.
- 1 January 2008
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 47 (12) , 751-760
Modification of otoacoustic emissions following ear-level exposure to MP3 player music
The purpose of this study was to examine if a pre-determined exposure level and duration of MP3 player music would result in significant changes in cochlear function when measured with audiometric and physiological methods. Distortion-product otoacoustic emissions (DPOAEs), synchronized spontaneous otoacoustic emissions (SSOAEs), and hearing thresholds were measured in 20 normal-hearing adults before and after a 30-minute MP3 player music exposure. DPOAEs were acquired with 65/45 dB SPL primary tones (f2=0.842–7.996 kHz) with a frequency resolution of 8 points/octave. A probe microphone system recorded ear-canal music levels and was used to equalize levels at approximately 85 dBC across individuals during the music presentation. Comparison of pre- and post-exposure measurements revealed no significant differences in hearing thresholds, but DPOAE levels in half-octave bands centered from 1.4–6.0 kHz were significantly reduced following the music exposure. Post-exposure shifts in SSOAE frequency and level were highly variable in individuals identified with SSOAEs. The results for the exposure conditions explored in this study indicate that changes in otoacoustic emissions may precede the development of music-induced hearing threshold shifts.
- 1 January 2006
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 45 (10) , 609-616
Properties of binaural vestibular evoked myogenic potentials elicited with air-conducted and bone-conducted tone bursts
The purpose of this investigation was to compare the effects of monaural and binaural stimulation on unilaterally-measured vestibular evoked myogenic potential (VEMP) magnitude and latency. The subjects were eighteen normal-hearing adults with no history of vestibular disease. Monaural VEMPs were acquired with air-conducted (AC) and bone-conducted (BC) 500 Hz tone bursts presented at 95 dB nHL and 70 dB nHL, respectively. These stimuli were simultaneously paired with 95 dB nHL contralateral tone bursts at 250, 500, 750, or 1000 Hz during acquisition of binaural VEMPs. Results indicated that AC-VEMP relative magnitudes decreased in each of the binaural conditions compared to the monaural condition. However, no changes in relative magnitude between conditions occurred for BC-VEMPs. Similar latencies were observed for monaural and binaural VEMPs. Differences in bilateral interaction seen between the AC-VEMP and BC-VEMP conditions are consistent with modification of sound transmission through the ear during presentations of binaural sound.
- 1 January 2006
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 45 (10) , 609-616
Properties of binaural vestibular evoked myogenic potentials elicited with air-conducted and bone-conducted tone bursts
The purpose of this investigation was to compare the effects of monaural and binaural stimulation on unilaterally-measured vestibular evoked myogenic potential (VEMP) magnitude and latency. The subjects were eighteen normal-hearing adults with no history of vestibular disease. Monaural VEMPs were acquired with air-conducted (AC) and bone-conducted (BC) 500 Hz tone bursts presented at 95 dB nHL and 70 dB nHL, respectively. These stimuli were simultaneously paired with 95 dB nHL contralateral tone bursts at 250, 500, 750, or 1000 Hz during acquisition of binaural VEMPs. Results indicated that AC-VEMP relative magnitudes decreased in each of the binaural conditions compared to the monaural condition. However, no changes in relative magnitude between conditions occurred for BC-VEMPs. Similar latencies were observed for monaural and binaural VEMPs. Differences in bilateral interaction seen between the AC-VEMP and BC-VEMP conditions are consistent with modification of sound transmission through the ear during presentations of binaural sound.