Je-Chin Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Je-Chin Han has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hamn-Ching Chen
Ocean Engineering Program, Department of Civil Engineering, Texas A & M University, College Station, TX 77843, USA
1 shared publication - Jae Su Kwak
School of Aerospace and Mechanical Engineering, Korea Aerospace University, Go-yang, Korea
1 shared publication - Jae Su Kwak
Texas A&M University, College Station, TX
1 shared publication James A. Parsons
Turbine Heat Transfer Laboratory, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843-3123, USA
1 shared publicationLuai Al-Hadhrami
Texas A&M University, College Station, TX
1 shared publicationTodd S. Griffith
Texas A&M University, College Station, TX
1 shared publication
Latest Publications
- 17 July 2003
- Published by Wiley in Journal of Heat Transfer
- Vol. 125 (4) , 669-677
Heat Transfer Coefficients on the Squealer Tip and Near Squealer Tip Regions of a Gas Turbine Blade
Detailed heat transfer coefficient distributions on a squealer tip of a gas turbine blade were measured using a hue detection based transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip regions of the pressure and suction sides of a blade were also measured. Tests were performed on a five-bladed linear cascade with a blow-down facility. The blade was a two-dimensional model of a first stage gas turbine rotor blade with a profile of a GE-E3 aircraft gas turbine engine rotor blade. The Reynolds number based on the cascade exit velocity and axial chord length of a blade was 1.1×106 and the total turning angle of the blade was 97.7 deg. The overall pressure ratio was 1.2 and the inlet and exit Mach number were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7 percent. The heat transfer measurements were taken at the three different tip gap clearances of 1.0 percent, 1.5 percent, and 2.5 percent of blade span. Results showed that the overall heat transfer coefficients on the squealer tip were higher than that on the shroud surface and the near tip regions of the pressure and suction sides. Results also showed that the heat transfer coefficients on the squealer tip and its shroud were lower than that on the plane tip and shroud. However, the reductions of heat transfer coefficients near the tip regions of the pressure and suction sides were not remarkable.
- 17 July 2003
- Published by Wiley in Journal of Heat Transfer
- Vol. 125 (4) , 669-677
Heat Transfer Coefficients on the Squealer Tip and Near Squealer Tip Regions of a Gas Turbine Blade
Detailed heat transfer coefficient distributions on a squealer tip of a gas turbine blade were measured using a hue detection based transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip regions of the pressure and suction sides of a blade were also measured. Tests were performed on a five-bladed linear cascade with a blow-down facility. The blade was a two-dimensional model of a first stage gas turbine rotor blade with a profile of a GE-E3 aircraft gas turbine engine rotor blade. The Reynolds number based on the cascade exit velocity and axial chord length of a blade was 1.1×106 and the total turning angle of the blade was 97.7 deg. The overall pressure ratio was 1.2 and the inlet and exit Mach number were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7 percent. The heat transfer measurements were taken at the three different tip gap clearances of 1.0 percent, 1.5 percent, and 2.5 percent of blade span. Results showed that the overall heat transfer coefficients on the squealer tip were higher than that on the shroud surface and the near tip regions of the pressure and suction sides. Results also showed that the heat transfer coefficients on the squealer tip and its shroud were lower than that on the plane tip and shroud. However, the reductions of heat transfer coefficients near the tip regions of the pressure and suction sides were not remarkable.
- 1 January 2002
- Published by ASME International
- p. 551-560
Heat Transfer in Rotating Rectangular Cooling Channels (AR=4) With Dimples
As the world of research seeks ways of improving the efficiency of turbomachinery, attention has recently focused on a relatively new type of internal cooling channel geometry, the dimple. Preliminary investigations have shown that the dimple enhances heat transfer with minimal pressure loss. An investigation into determining the effect of rotation on heat transfer in a rectangular channel (aspect ratio = 4:1) with dimples is detailed in this paper. The range of flow parameters includes Reynolds number (Re = 5000–40000), rotation number (Ro = 0.04–0.3) and inlet coolant-to-wall density ratio (Δρ/ρ = 0.122). Two different surface configurations are explored, including a smooth duct and dimpled duct with dimple depth-to-print diameter (δ/Dp ) ratio of 0.3. A dimple surface density of 10.9 dimples/in2 was used for each of the principal surfaces (leading and trailing) with a total of 131 equally spaced hemispherical dimples per surface; the side surfaces are smooth. Two channel orientations of β = 90° and 135° with respect to the plane of rotation are explored to determine channel orientation effect. Results show a definite channel orientation effect, with the trailing-edge channel enhancing heat transfer more than the orthogonal channel. Also, the dimpled channel behaves somewhat like a 45° angled rib channel, but with less spanwise variations in heat transfer.
- 1 January 2002
- Published by ASME International
- p. 551-560
Heat Transfer in Rotating Rectangular Cooling Channels (AR=4) With Dimples
As the world of research seeks ways of improving the efficiency of turbomachinery, attention has recently focused on a relatively new type of internal cooling channel geometry, the dimple. Preliminary investigations have shown that the dimple enhances heat transfer with minimal pressure loss. An investigation into determining the effect of rotation on heat transfer in a rectangular channel (aspect ratio = 4:1) with dimples is detailed in this paper. The range of flow parameters includes Reynolds number (Re = 5000–40000), rotation number (Ro = 0.04–0.3) and inlet coolant-to-wall density ratio (Δρ/ρ = 0.122). Two different surface configurations are explored, including a smooth duct and dimpled duct with dimple depth-to-print diameter (δ/Dp ) ratio of 0.3. A dimple surface density of 10.9 dimples/in2 was used for each of the principal surfaces (leading and trailing) with a total of 131 equally spaced hemispherical dimples per surface; the side surfaces are smooth. Two channel orientations of β = 90° and 135° with respect to the plane of rotation are explored to determine channel orientation effect. Results show a definite channel orientation effect, with the trailing-edge channel enhancing heat transfer more than the orthogonal channel. Also, the dimpled channel behaves somewhat like a 45° angled rib channel, but with less spanwise variations in heat transfer.
- 1 January 2002
- Published by ASME International
- Vol. 2002, 245-254
Heat Transfer Coefficient on the Squealer Tip and Near Squealer Tip Regions of a Gas Turbine Blade
Detailed heat transfer coefficient distributions on a squealer tip of a gas turbine blade were measured using a hue detection based transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip region of the pressure and suction sides of a blade were also measured. Tests were performed on a five-bladed linear cascade with blow down facility. The blade was a 2-dimensional model of a first stage gas turbine rotor blade with a profile of a GE-E3 aircraft gas turbine engine rotor blade. The Reynolds number based on the cascade exit velocity and axial chord length of a blade was 1.1×106 and the total turning angle of the blade was 97.7°. The overall pressure ratio was 1.23 and the inlet and exit Mach number were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. The heat transfer measurements were taken at the three different tip gap clearances of 1.0%, 1.5% and 2.5% of blade span. Results showed that the overall heat transfer coefficient on the squealer tip was higher than that on the shroud and the near tip region of the pressure and suction side. Results also showed that the heat transfer coefficients on the squealer tip and its shroud were lower than that on the plane tip and shroud, but the heat transfer coefficients on the near tip region of suction and pressure sides were higher for the squealer tip case.
- 1 January 2002
- Published by ASME International
- Vol. 2002, 245-254
Heat Transfer Coefficient on the Squealer Tip and Near Squealer Tip Regions of a Gas Turbine Blade
Detailed heat transfer coefficient distributions on a squealer tip of a gas turbine blade were measured using a hue detection based transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip region of the pressure and suction sides of a blade were also measured. Tests were performed on a five-bladed linear cascade with blow down facility. The blade was a 2-dimensional model of a first stage gas turbine rotor blade with a profile of a GE-E3 aircraft gas turbine engine rotor blade. The Reynolds number based on the cascade exit velocity and axial chord length of a blade was 1.1×106 and the total turning angle of the blade was 97.7°. The overall pressure ratio was 1.23 and the inlet and exit Mach number were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. The heat transfer measurements were taken at the three different tip gap clearances of 1.0%, 1.5% and 2.5% of blade span. Results showed that the overall heat transfer coefficient on the squealer tip was higher than that on the shroud and the near tip region of the pressure and suction side. Results also showed that the heat transfer coefficients on the squealer tip and its shroud were lower than that on the plane tip and shroud, but the heat transfer coefficients on the near tip region of suction and pressure sides were higher for the squealer tip case.
- Open Access
- 27 May 2000
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 7 (3) , 195-208
Numerical Prediction of Flow and Heat Transferin a Two‐pass Square Channel with 90° Ribs
Numerical predictions of three‐dimensional flow and heat transfer are presented for a two‐pass square channel with ° parallel ribs. Square sectioned ribs were employed along the one side surface. The rib height‐to‐hydraulic diameter ratio (e/Dh) is 0.125 and the rib pitch‐to‐height ratio (P/e) is 10. The computation results were compared with the experimental data of Ekkad and Han (1997) at a Reynolds number (Re) of 30,000.A multi‐block numerical method was used with a chimera domain decomposition technique. The finite analytic method solved the Reynolds‐Averaged Navier‐Stokes equation in conjunction with a near‐wall second‐order Reynolds stress (secondmoment) closure model, and a two‐layer k − ε isotropic eddy viscosity model. Comparing the second‐moment and two‐layer calculations with the experimental data clearly demonstrated that the rib turbulators and the 180° sharp turn of the channel produced strong non‐isotropic turbulence and heat fluxes, which significantly affected the flow fields and heat transfer coefficients. The near‐wall second‐moment closure model provides an improved heat transfer prediction in comparison with the k − ε model.
- 27 May 2000
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 7 (3) , 195-208
Open AccessNumerical Prediction of Flow and Heat Transferin a Two‐pass Square Channel with 90° Ribs
Numerical predictions of three‐dimensional flow and heat transfer are presented for a two‐pass square channel with ° parallel ribs. Square sectioned ribs were employed along the one side surface. The rib height‐to‐hydraulic diameter ratio (e/Dh) is 0.125 and the rib pitch‐to‐height ratio (P/e) is 10. The computation results were compared with the experimental data of Ekkad and Han (1997) at a Reynolds number (Re) of 30,000.A multi‐block numerical method was used with a chimera domain decomposition technique. The finite analytic method solved the Reynolds‐Averaged Navier‐Stokes equation in conjunction with a near‐wall second‐order Reynolds stress (secondmoment) closure model, and a two‐layer k − ε isotropic eddy viscosity model. Comparing the second‐moment and two‐layer calculations with the experimental data clearly demonstrated that the rib turbulators and the 180° sharp turn of the channel produced strong non‐isotropic turbulence and heat fluxes, which significantly affected the flow fields and heat transfer coefficients. The near‐wall second‐moment closure model provides an improved heat transfer prediction in comparison with the k − ε model.
- Open Access
- 17 August 1999
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 7 (2) , 87-103
Rotation Effect on Jet Impingement Heat Transfer in Smooth Rectangular Channels with Film Coolant Extraction
The effect of channel rotation on jet impingement cooling by arrays of circular jets in twin channels was studied. Impinging jet flows were in the direction of rotation in one channel and opposite to the direction of rotation in the other channel. The jets impinged normally on the smooth, heated target wall in each channel. The spent air exited the channels through extraction holes in each target wall, which eliminates cross flow on other jets. Jet rotation numbers and jet Reynolds numbers varied from 0.0 to 0.0028 and 5000 to 10,000, respectively. For the target walls with jet flow in the direction of rotation (or opposite to the direction of rotation), as rotation number increases heat transfer decreases up to 25% (or 15%) as compared to corresponding results for non‐rotating conditions. This is due to the changes in flow distribution and rotation induced Coriolis and centrifugal forces.
- 17 August 1999
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 7 (2) , 87-103
Open AccessRotation Effect on Jet Impingement Heat Transfer in Smooth Rectangular Channels with Film Coolant Extraction
The effect of channel rotation on jet impingement cooling by arrays of circular jets in twin channels was studied. Impinging jet flows were in the direction of rotation in one channel and opposite to the direction of rotation in the other channel. The jets impinged normally on the smooth, heated target wall in each channel. The spent air exited the channels through extraction holes in each target wall, which eliminates cross flow on other jets. Jet rotation numbers and jet Reynolds numbers varied from 0.0 to 0.0028 and 5000 to 10,000, respectively. For the target walls with jet flow in the direction of rotation (or opposite to the direction of rotation), as rotation number increases heat transfer decreases up to 25% (or 15%) as compared to corresponding results for non‐rotating conditions. This is due to the changes in flow distribution and rotation induced Coriolis and centrifugal forces.