Christopher J. Wahl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christopher J. Wahl has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Andrew L. Merritt
University of Washington Sports Medicine Clinic
1 shared publication Cory J. Lamblin
Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA 98195, USA
1 shared publicationGregg Nicandri
Department of Orthopaedics and Sports Medicine University of Washington Seattle Washington U.S.A.
1 shared publicationJohn D. MacGillivray
1 shared publication- Kyle F. Chun
University of Washington Sports Medicine Clinic
1 shared publication
Latest Publications
- 21 June 2013
- Published by Springer Nature
- p. 371-386
Fracture-dislocations: Evaluation and Treatment
- 1 April 2008
- Published by Wiley in Arthroscopy
- Vol. 24 (4) , 486-489
Single–Achilles Allograft Posterior Cruciate Ligament and Medial Collateral Ligament Reconstruction: A Technique to Avoid Osseous Tunnel Intersection, Improve Construct Stiffness, and Save on Allograft Utilization
We present a method for single–Achilles allograft medial collateral ligament (MCL) and posterior cruciate ligament (PCL) reconstruction that eliminates the risk of tunnel intersection, stiffens the construct, and maximizes utilization of allograft tissue. An Achilles tendon allograft is prepared with an 11‐ to 12‐mm bone plug with a gradual taper to 7 mm over approximately 15 cm. A transtibial PCL tunnel is created under fluoroscopic and arthroscopic guidance. The femoral tunnel is prepared in an “outside‐in” fashion under direct arthroscopic visualization, originating at the anatomic origin of the MCL on the medial epicondyle and entering the joint at the anatomic origin of the anterolateral bundle of the PCL. The Achilles graft is pulled into the joint through the tibial tunnel and routed into the femoral tunnel so that the soft tissue exits at the medial epicondyle. The bone plug is fluoroscopically guided to the posterior aperture of the tibial tunnel and fixed with a bioabsorbable interference screw. The pretensioned graft is fixed in the femoral tunnel via interference screw fixation with the knee in 90° of flexion. The isometric position of the MCL insertion is identified with a K‐wire isometer, and the graft is fixed in place at this point by use of an interference screw or screw and washer.
- 1 April 2008
- Published by Wiley in Arthroscopy
- Vol. 24 (4) , 486-489
Single–Achilles Allograft Posterior Cruciate Ligament and Medial Collateral Ligament Reconstruction: A Technique to Avoid Osseous Tunnel Intersection, Improve Construct Stiffness, and Save on Allograft Utilization
We present a method for single–Achilles allograft medial collateral ligament (MCL) and posterior cruciate ligament (PCL) reconstruction that eliminates the risk of tunnel intersection, stiffens the construct, and maximizes utilization of allograft tissue. An Achilles tendon allograft is prepared with an 11‐ to 12‐mm bone plug with a gradual taper to 7 mm over approximately 15 cm. A transtibial PCL tunnel is created under fluoroscopic and arthroscopic guidance. The femoral tunnel is prepared in an “outside‐in” fashion under direct arthroscopic visualization, originating at the anatomic origin of the MCL on the medial epicondyle and entering the joint at the anatomic origin of the anterolateral bundle of the PCL. The Achilles graft is pulled into the joint through the tibial tunnel and routed into the femoral tunnel so that the soft tissue exits at the medial epicondyle. The bone plug is fluoroscopically guided to the posterior aperture of the tibial tunnel and fixed with a bioabsorbable interference screw. The pretensioned graft is fixed in the femoral tunnel via interference screw fixation with the knee in 90° of flexion. The isometric position of the MCL insertion is identified with a K‐wire isometer, and the graft is fixed in place at this point by use of an interference screw or screw and washer.
- 1 November 2007
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 16 (6) , e25-e30
Three congenital variations in the long head of the biceps tendon: A review of pathoanatomic considerations and case reports
- 1 November 2007
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 16 (6) , e25-e30
Three congenital variations in the long head of the biceps tendon: A review of pathoanatomic considerations and case reports