Kanthan Theivendran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kanthan Theivendran has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Vaikunthan Rajaratnam
Hand and Reconstructive Microsurgery Service, Orthopaedic Surgery Department, Khoo Teck Puat Hospital, 768828, Singapore
3 shared publications A. Abudu
The Royal Orthopaedic Hospital
1 shared publicationAndrew Mahon
1 shared publicationCallum W McBryde
Trauma and Orthopaedics, University Hospital Birmingham NHS Foundation Trust, Birmingham, UK
1 shared publicationCaroline J. Lever
New Cross Hospital Wolverhampton UK
1 shared publicationJ. C. Luscombe
The Royal Orthopaedic Hospital, Birmingham, UK
1 shared publication
Latest Publications
- 1 August 2010
- Vol. 76 (4) , 425-31
Operative management of intra-articular distal interphalangeal joint fractures of the hand.
The management of intra-articular fractures of the hand represents a challenge. Large articular fragments require reduction and operative fixation. A number of surgical techniques have been described in literature, with variable results. Distal interphalangeal joint fractures have been fixed by various methods including screw, plate and suture techniques. Generally operative fixation is indicated when more than 30% of the articular surface is involved with or without subluxation of the joint. The aim of surgery is to reduce the fracture fragments anatomically whilst providing osseous stability, and to commence early active movement of the joint to prevent stiffness. In this review we aim to summarise the main management options for intra-articular distal interphalangeal fractures, placing particular emphasis on surgical treatment.
- 1 August 2010
- Vol. 76 (4) , 425-31
Operative management of intra-articular distal interphalangeal joint fractures of the hand.
The management of intra-articular fractures of the hand represents a challenge. Large articular fragments require reduction and operative fixation. A number of surgical techniques have been described in literature, with variable results. Distal interphalangeal joint fractures have been fixed by various methods including screw, plate and suture techniques. Generally operative fixation is indicated when more than 30% of the articular surface is involved with or without subluxation of the joint. The aim of surgery is to reduce the fracture fragments anatomically whilst providing osseous stability, and to commence early active movement of the joint to prevent stiffness. In this review we aim to summarise the main management options for intra-articular distal interphalangeal fractures, placing particular emphasis on surgical treatment.
- 1 June 2010
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 19 (4) , 524-532
Surgical treatment of complex distal humeral fractures: Functional outcome after internal fixation using precontoured anatomic plates
- 1 June 2010
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 19 (4) , 524-532
Surgical treatment of complex distal humeral fractures: Functional outcome after internal fixation using precontoured anatomic plates
- 1 October 2009
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 91 (7) , 617-618
A Technique to Stabilise the Herbert–Huene Jig During Scaphoid Fracture Fixation
- 1 October 2009
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 91 (7) , 617-618
A Technique to Stabilise the Herbert–Huene Jig During Scaphoid Fracture Fixation
- 1 August 2009
- Vol. 75 (4) , 472-6
Is the tip of the greater trochanter a reliable reference for the rotation centre of the femoral head in total hip arthroplasty?
A variety of techniques have been used to determine intra-operative leg length during total hip arthroplasty. One method often described is using the tip of greater trochanter as the reference for the rotation centre of the femoral head to align the femoral component. There is little in the literature to support this method of leg length restoration. We analysed standard anterior-posterior pelvic radiographs of 225 patients with osteoarthritis of the hip who were about to undergo total hip arthroplasty. The distance between the tip of the greater trochanter and the rotation centre of the femoral head was measured for the affected hip. The average location of the tip of greater trochanter is 3.4 mm proximal to the centre of the femoral head, with a range from 20 mm proximal to 10 mm distal to the femoral head centre. There is considerable variation in the anatomy of the proximal femur; however, with adequate preoperative templating, the greater trochanter can be a helpful guide to determine the rotation centre of the femoral head of the femoral component and should be used with other conventional techniques to determine leg length intra-operatively.
- 1 August 2009
- Vol. 75 (4) , 472-6
Is the tip of the greater trochanter a reliable reference for the rotation centre of the femoral head in total hip arthroplasty?
A variety of techniques have been used to determine intra-operative leg length during total hip arthroplasty. One method often described is using the tip of greater trochanter as the reference for the rotation centre of the femoral head to align the femoral component. There is little in the literature to support this method of leg length restoration. We analysed standard anterior-posterior pelvic radiographs of 225 patients with osteoarthritis of the hip who were about to undergo total hip arthroplasty. The distance between the tip of the greater trochanter and the rotation centre of the femoral head was measured for the affected hip. The average location of the tip of greater trochanter is 3.4 mm proximal to the centre of the femoral head, with a range from 20 mm proximal to 10 mm distal to the femoral head centre. There is considerable variation in the anatomy of the proximal femur; however, with adequate preoperative templating, the greater trochanter can be a helpful guide to determine the rotation centre of the femoral head of the femoral component and should be used with other conventional techniques to determine leg length intra-operatively.
- 17 February 2009
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (10) , 1231-1233
Good result after surgical treatment of Pellegrini–Stieda syndrome
Ossification of the femoral attachment of the medial collateral ligament (MCL) of the knee with associated pain and restricted movements is rare and is characteristic of the Pellegrini–Stieda (PS) syndrome. Although in mild cases conservative treatment is often successful, patients with more significant bone formation and persistent symptoms require surgical excision. We describe a case of PS syndrome with a description of the surgical technique consisting of excision of the bony lesion and reconstruction of the MCL by using the adductor magnus tendon.
- 17 February 2009
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (10) , 1231-1233
Good result after surgical treatment of Pellegrini–Stieda syndrome
Ossification of the femoral attachment of the medial collateral ligament (MCL) of the knee with associated pain and restricted movements is rare and is characteristic of the Pellegrini–Stieda (PS) syndrome. Although in mild cases conservative treatment is often successful, patients with more significant bone formation and persistent symptoms require surgical excision. We describe a case of PS syndrome with a description of the surgical technique consisting of excision of the bony lesion and reconstruction of the MCL by using the adductor magnus tendon.
- 24 January 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 129 (12) , 1667-1671
Removal of broken solid femoral nail: a modified bent tip guide wire technique
A broken solid femoral nail can be challenging to remove. We describe a modified bent tip guide wire technique for extraction of a broken solid retrograde femoral nail from the proximal femur. The broken nail was removed successfully through the original retrograde entry point to allow for an exchange femoral nailing in a patient with a hypertrophic non-union. This novel technique avoids any additional exposure other than that required to remove and insert the nail.
- 24 January 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 129 (12) , 1667-1671
Removal of broken solid femoral nail: a modified bent tip guide wire technique
A broken solid femoral nail can be challenging to remove. We describe a modified bent tip guide wire technique for extraction of a broken solid retrograde femoral nail from the proximal femur. The broken nail was removed successfully through the original retrograde entry point to allow for an exchange femoral nailing in a patient with a hypertrophic non-union. This novel technique avoids any additional exposure other than that required to remove and insert the nail.
- 1 January 2008
- Published by SAGE Publications in Trauma
- Vol. 10 (1) , 25-33
Scapula fractures: A review
Fractures of the scapula are uncommon and are generally the result of high energy trauma with associated serious injuries. A majority can be managed conservatively but significant displacement of fracture fragments especially involving the glenoid articular surface may require operative fixation to prevent serious functional disability. This review discusses the diagnosis, classification and treatment of these injuries.
- 1 January 2008
- Published by SAGE Publications in Trauma
- Vol. 10 (1) , 25-33
Scapula fractures: A review
Fractures of the scapula are uncommon and are generally the result of high energy trauma with associated serious injuries. A majority can be managed conservatively but significant displacement of fracture fragments especially involving the glenoid articular surface may require operative fixation to prevent serious functional disability. This review discusses the diagnosis, classification and treatment of these injuries.
- Open Access
- 14 September 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 33 (1) , 101-104
The relative safety of one-stage bilateral total knee arthroplasty
Patients with osteoarthritis of the knee often require bilateral knee replacement before fulfilling their full ambulatory potential. Despite extensive research there is considerable debate about the risks of performing simultaneous bilateral knee replacements under the same anaesthetic. Our aim was to compare the relative short-term morbidity of one-stage bilateral with unilateral total knee arthroplasty in a retrospective, consecutive cohort of patients. Seventy-two bilateral knee replacements were case-matched for age and gender with 144 unilateral knees. One-stage bilateral arthroplasty was associated with increased morbidity with respect to wound (6.0 vs 0.7%; p = 0.003) and deep prosthetic (3.5% vs 0.7 %; p = 0.02) infections, cardiac complications (3.5% vs 0.7%; p = 0.04) and chest infections (7.0% vs 1.4%; p = 0.04). No differences were observed in the mortality rates (p = 0.30) and risk of thrombo-embolism (p = 0.70). We conclude that one-stage bilateral total knee arthroplasty is associated with increased morbidity compared with unilateral knee replacement.
- 14 September 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 33 (1) , 101-104
Open AccessThe relative safety of one-stage bilateral total knee arthroplasty
Patients with osteoarthritis of the knee often require bilateral knee replacement before fulfilling their full ambulatory potential. Despite extensive research there is considerable debate about the risks of performing simultaneous bilateral knee replacements under the same anaesthetic. Our aim was to compare the relative short-term morbidity of one-stage bilateral with unilateral total knee arthroplasty in a retrospective, consecutive cohort of patients. Seventy-two bilateral knee replacements were case-matched for age and gender with 144 unilateral knees. One-stage bilateral arthroplasty was associated with increased morbidity with respect to wound (6.0 vs 0.7%; p = 0.003) and deep prosthetic (3.5% vs 0.7 %; p = 0.02) infections, cardiac complications (3.5% vs 0.7%; p = 0.04) and chest infections (7.0% vs 1.4%; p = 0.04). No differences were observed in the mortality rates (p = 0.30) and risk of thrombo-embolism (p = 0.70). We conclude that one-stage bilateral total knee arthroplasty is associated with increased morbidity compared with unilateral knee replacement.
- 1 June 2007
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 58 (6) , 625-629
Proximal Interphalangeal Joint Fractures of the Hand
The authors present a series of 11 consecutive patients who sustained an intra-articular fracture of the proximal interphalangeal (PIP) joint and 1 patient with a fracture of the interphalangeal joint of the thumb treated with a Kirschner wire external dynamic traction device. Range of motion and grip strength were measured. We used the Michigan Hand Outcome Questionnaire (MHQ) to obtain a subjective response to the treatment. Average range of motion of the PIP joint was 64° and distal interphalangeal joint was 52°. The average grip strength was 86% with a mean MHQ score of 90. Two patients had pin site infections treated successfully with antibiotics. All fractures had united at final follow up with <1-mm articular step present. Our series highlights that these are difficult injuries to treat and that anatomic reduction is not always possible. However, this technique is simple and quick to perform while allowing early joint mobilization. The subjective response to treatment is comparable with other studies using a similar device.
- 1 June 2007
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 58 (6) , 625-629
Proximal Interphalangeal Joint Fractures of the Hand
The authors present a series of 11 consecutive patients who sustained an intra-articular fracture of the proximal interphalangeal (PIP) joint and 1 patient with a fracture of the interphalangeal joint of the thumb treated with a Kirschner wire external dynamic traction device. Range of motion and grip strength were measured. We used the Michigan Hand Outcome Questionnaire (MHQ) to obtain a subjective response to the treatment. Average range of motion of the PIP joint was 64° and distal interphalangeal joint was 52°. The average grip strength was 86% with a mean MHQ score of 90. Two patients had pin site infections treated successfully with antibiotics. All fractures had united at final follow up with <1-mm articular step present. Our series highlights that these are difficult injuries to treat and that anatomic reduction is not always possible. However, this technique is simple and quick to perform while allowing early joint mobilization. The subjective response to treatment is comparable with other studies using a similar device.
- 1 January 2007
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 58 (1) , 112-115
A Novel Hook Plate Fixation Technique for the Treatment of Mallet Fractures
Bony mallet injuries are generally treated nonoperatively, but when the fragment involves a significant percentage of the articular surface, articular incongruity and instability can occur. A number of techniques have been described for the fixation of such fractures and each has its own problems. Anatomic reduction and secure fixation of small fragments can be challenging. Our objective is to describe a new surgical technique using a 1.3-mm hook plate that provides good reduction and stable fixation of a mallet fracture, with early mobilization of the distal interphalangeal joint.
- 1 January 2007
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 58 (1) , 112-115
A Novel Hook Plate Fixation Technique for the Treatment of Mallet Fractures
Bony mallet injuries are generally treated nonoperatively, but when the fragment involves a significant percentage of the articular surface, articular incongruity and instability can occur. A number of techniques have been described for the fixation of such fractures and each has its own problems. Anatomic reduction and secure fixation of small fragments can be challenging. Our objective is to describe a new surgical technique using a 1.3-mm hook plate that provides good reduction and stable fixation of a mallet fracture, with early mobilization of the distal interphalangeal joint.