APAlexander H. Petter-Puchner

Alexander H. Petter-Puchner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander H. Petter-Puchner has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • H. Redl

    Ludwig Boltzmann Institute for Experimental and Clinical Traumatology in the Research Center of AUVA and Austrian Cluster for Tissue Regeneration

    4 shared publications
  • Heinz Redl

    Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration and Research Center of AUVA, Vienna, Austria

    3 shared publications
  • R. H. Fortelny

    Second Department of Surgery, Wilhelminenspital, Vienna, Austria

    3 shared publications
  • W. Öhlinger

    Krankenhaus Krems

    3 shared publications
  • K. S. Glaser

    Second Department of Surgery, Wilhelminenspital, Vienna, Austria

    2 shared publications
  • Martijn van Griensven

    Department of Cell Biology-Inspired Tissue Engineering, MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Maastricht, The Netherlands

    2 shared publications

Latest Publications

  • Adverse effects of polyvinylidene fluoride-coated polypropylene mesh used for laparoscopic intraperitoneal onlay repair of incisional hernia

    by R. H. Fortelny, A. H. Petter‐Puchner, K. S. Glaser, F. Offner, T. Benesch, M. Rohr

    Background: Polyvinylidene fluoride‐coated polypropylene meshes have been developed specifically for intraperitoneal onlay mesh repair. They combine a macroporous design with biomechanical characteristics compatible with the abdominal wall and are reported to have favourable antiadhesive properties. This retrospective study reports complications related to one of these materials, DynaMesh®. Methods: Twenty‐nine patients underwent intraperitoneal onlay mesh repair with DynaMesh® at one of two hospitals. Patients characteristics, surgical procedures and postoperative analgesia were comparable at both sites. Results: Six patients developed DynaMesh®‐related complications that required surgical reintervention by laparotomy within 1 year of operation. Surgical reintervention was for adhesions in five patients and the mesh had to be explanted in three. One mesh was explanted because of early infection. Adhesions to DynaMesh® were found in two patients who had surgery for unrelated reasons. Conclusion: Laparoscopic intraperitoneal onlay DynaMesh® repair was associated with a high rate of complications. Copyright © 2010 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.


  • A Comparison of a Cyanaocrylate Glue (Glubran) vs. Fibrin Sealant (Tisseel) in Experimental Models of Partial Pulmonary Resection and Lung Incison in Rabbits

    by Alexander H. Petter-Puchner, Manuela Simunek, Heinz Redl, Katrin U. Puchner, Martijn Van Griensven

    Introduction: Bronchopleural fistulas (BPF) and air leaks (AL) present major complications after pulmonary resection. Various tissue sealants have been proposed for their prevention, e.g., fibrin sealant (FS) and cyanoacrylate glues (CA). Contrary to the safety record of FS, substantial side effects such as foreign body reaction and impaired tissue integration have been reported for CA. This study compares the sealing efficacy and biocompatibility as well as side effects of FS and CA in experimental partial pulmonary resection and lung incision in rabbits. Methods: 26 New Zealand white rabbits (3 kg) were randomized to one of the three groups: partial pulmonary resection (A, acute model; n == 7 FS/ 7CA), lung incision [[2 (B; n == 3 FS/ 3 CA)]], and 14-day observation period (C; n == 3 FS/ 3 CA). In all groups (A, B, and C), FS was considered as control and CA as treatment. Surgery was carried out in general anaesthesia and mechanical ventilation. For partial lung resection a median thoracotomy was performed and the apex of the left median lobe was resected and the parenchymal surface covered with 0.09 ml of FS and CA. The thoraic cavity was filled with ringer solution after 5 minutes. The inspiratory minute volume (IMV) was increased by 0.02 l after every 4th inspiration. In groups B and C, a left lateral thoracotomy was performed in the 4th intercostal space and the left median lobe was incisised with a scalpel. The incison was covered with 0.5 ml of FS or CA. At autopsy (B and C) the operation site was assessed macroscopically. Histology was performed in all animals. Results: In terms of sealing purposes, FS and CA yielded comparable results in all groups. CA elicited a substantial increase of tissue temperature in the acute phase immediately after application (A). After 14 days CA residues were found, whereas FS was completely degraded. Histology showed a pronounced inflammatory response to CA but not to FS. We conclude that although the effect of airtight sealing was equally satisfying, our results emphasize that FS is preferable to CA for the prevention of BPF and AL due to superior biocompatibility and degradability. Longterm effects of CA residues on pulmonary tissue require further experimental testing.


  • Manganese Enhanced Magnetic Resonance Imaging in a Contusion Model of Spinal Cord Injury in Rats: Correlation With Motor Function

    by Nadja Cand. Med. Walder, Alexander H. Petter-Puchner, Mika Brejnikow, Heinz Redl, Marco Essig, Bram Stieltjes

    Objectives: Various models of spinal cord injury in rodents have been established, and also techniques for lesion quantification. Measurement of the extent of the underlying injury is essential for monitoring the reproducibility of the experimental injury and assessment of therapeutic effects. In this study, we tested manganese-enhanced magnetic resonance imaging (MEMRI) for postmortem quantification of experimental spinal cord injury in rats. Materials and Methods: Twelve rats were subjected to contusion injuries at the 11th thoracic vertebra, followed by MnCl2 injections into the cisterna magna. After 3 days of observation, postmortem MEMRI-features were correlated with values of locomotion testing and histology. Results: MnCl2 yielded a strong contrast enhancement of the uninjured spinal cord, whereas no enhancement was observed at the injury site or caudally. Magnetic resonance imaging findings correlate closely with locomotor ratings. Conclusions: MEMRI represents a reliable method for visualization and functional assessment of spinal cord integrity in rats.


  • The assessment of quality of life in a trial on lightweight mesh fixation with fibrin sealant in transabdominal preperitoneal hernia repair

    by R. H. Fortelny, R. Schwab, K. S. Glaser, K. U. Puchner, C. May, F. König, H. Redl, A. H. Petter-Puchner

    Chronic pain is a major concern in open and laparoscopic hernia repair. Study groups have adopted a variety of tools to assess postoperative (postOP) pain and quality of life (QoL). Unfortunately, modifications of existing tests and self-designed questionnaires are common, yielding unvalidated results and making comparison of data difficult. The aim of this study was to assess the QoL in transabdominal preperitoneal mesh repair (TAPP) with fibrin sealant (FS) for lightweight mesh fixation, applying the standardised Short Form 36 (SF36) questionnaire in its unmodified design. The SF36 has already been validated and implemented in a large number of studies. In this trial the physical-health-component summary measure (PHM), summarising the physical health-related scales, served as the primary outcome parameter.


  • Adverse Effects Associated with the Use of Porcine Cross-Linked Collagen Implants in an Experimental Model of Incisional Hernia Repair

    by Alexander H. Petter-Puchner, René H. Fortelny, Nadja Walder, Rainer Mittermayr, Wolfgang Öhlinger, Martijn van Griensven, Heinz Redl


  • NON-activated protein C as post-treatment after spinal cord compression injury in rats

    by A. H. Petter-Puchner, J. Sieber, R. Hopf, W. Öhlinger, M. Schuller, H. Redl

    Background. Neuroprotective effects of recombinant human activated Protein C (rhAPC) in models of Spinal Cord Injury (SCI) and ischemic stroke have been reported in rodents. To rule out immunogenicity of rhAPC and to possibly maintain the physiological PC/thrombin balance the use of zymogen PC in SCI might be preferable. Although activation of Protein C (PC) has been demonstrated in rats, the efficacy and drug safety of NON activated PC has not been previously tested in experimental SCI. Methods. Twelve rats were subjected to 40 g compression of the spinal cord at TH11 for 20 minutes and randomly allocated to either the NON activated PC (25 IU/kg) or the Placebo group (saline). Results. 25 IU treatment yielded improved recovery from SCI compared to placebo and the triple fold dose of PC (75 IU/kg) was subsequently tested to detect treatment associated complications (TAC). Treatment was administered as a single shot via the right vena jugularis forty minutes after onset of compression. The observation period was 5 weeks in 25 IU treated and 1 week in the 75 IU treated rats. Improvement of motor function recovery was measured with behaviour tests and electrophysiology. Findings. Single shot treatment with 25 IU/kg of NON activated PC led to improved recovery in terms of behaviour and electrophysiology. TACs neither occurred in the 25 IU nor in the 75 IU group within one week. Conclusion. NON activated PC is a potent and safe drug in experimental SCI and should be considered for treatment in neurotrauma.


  • Adverse effects of porcine small intestine submucosa implants in experimental ventral hernia repair

    by A. H. Petter-Puchner, R. H. Fortelny, R. Mittermayr, N. Walder, W. Öhlinger, H. Redl

    Biomeshes made of porcine small intestine submucosa (SIS) have recently been suggested for repair of ventral hernia. A fully biodegradable combination of implant and fibrin sealant fixation was assessed in a new rat model with sutures serving as control. In 10 Sprague–Dawley rats, two defects per animal were created in the abdominal wall left and right of the linea alba (1 cm in diameter), and the peritoneum was spared. The lesions were left untreated for 10 days to achieve a chronic condition and were then covered with SIS (2 × 2 cm), sealed or sutured (n = 10 per group). Randomization allowed sealant and sutures in one animal. Animals were killed on postoperative day 17, and implant sites were analyzed macroscopically, histologically, and microbiologically. Abscedation, encapsulation, and putrid seroma were observed in all samples, regardless of fixation technique. Histology revealed lytic necrosis and extensive inflammatory response of the surrounding tissue. Tissue samples obtained from three implant sites were positive for β-hemolytic Streptococcus. SIS was not detectable after 17 days. Adverse effects were observed using SIS in an experimental model of ventral hernia and were not linked to fixation method or study design. Further experimental investigations on SIS are necessary before its clinical use in hernia repair.


  • Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat

    by Alexander H. Petter-Puchner, R. Fortelny, R. Mittermayr, W. Öhlinger, H. Redl

    Incisional and inguinal hernia repair are among the most common procedures of general surgery. Mesh fixation by means of staples or sutures may lead to severe complications. The use of fibrin sealant (FS) has been suggested as alternative, but data on biocompatibility and adhesive strength of FS in combination with macroporous meshes is limited. Ventral hernia (n=8 per group) was treated in rats in onlay technique with two types of meshes, fibrin sealed or stapled. TI-Mesh (TMxl) extralight and VYPROII (VPII) were tested 17 days post op. No failure in mechanical tests (tensile and burst strength) occurred in sealed or stapled meshes. Histology revealed equally good tissue integration and neovascularization in all groups. Fibrin sealant yields excellent fixation in experimental hernia repair. This rat model is suitable for testing meshes and fixation techniques.