Timothy J. Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Timothy J. Johnson has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Nancy B. Valentine
Pacific Northwest National Lab. (United States)
7 shared publicationsStephen D. Williams
A. R. Smith Department of Chemistry, Appalachian State University, Boone, NC 28618, USA
4 shared publicationsYin-Fong Su
Pacific Northwest National Lab. (United States)
4 shared publicationsBruce E. Bernacki
Pacific Northwest National Lab. (United States)
2 shared publicationsJames F. Kelly
Pacific Northwest National Laboratory, P. O. Box 999, Mail Stop K8-88, Richland, WA 99352, USA
2 shared publicationsRobert L. Sams
Pacific Northwest National Laboratory
2 shared publications
Latest Publications
- 18 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8743, 87431L
Intensity offset and correction of solid spectral library samples measured behind glass
Accurate and calibrated diffuse reflectance spectra libraries of solids are becoming more important for hyperspectral and multispectral remote sensing exploitation. Many solids are in the form of powders or granules and in order to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass or quartz for the ultraviolet (UV), visible or near-infrared spectral regions to prevent their unwanted dispersal into the instrument or laboratory environment. Using both experimental and theoretical methods we have found that for the case of fused quartz this leads to an intensity offset in the reflectance values. Although expected dispersive effects were observed for the fused quartz window in the UV, the measured hemispherical reflectance values are predominantly vertically shifted by the reflectance from the air-quartz and sample-quartz interfaces with intensity dependent offsets leading to measured values up to ∼6% too high for a 2% reflectance surface, ∼3.8% too high for 10% reflecting materials, approximately correct (to within experimental error) for 40% to 60% diffuse reflecting surfaces, and ∼2% too low for 99% reflecting Spectralon surfaces. For the diffuse reflectance case, the measured values are uniformly too low due to the glass, with differences nearly 6% too high for reflectance values approaching 99%. The deviations arise from the added reflections from the quartz surfaces as verified by theory, modeling and experiment. Empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300 nm to 2300 nm range.
- 18 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8743, 87431L
Intensity offset and correction of solid spectral library samples measured behind glass
Accurate and calibrated diffuse reflectance spectra libraries of solids are becoming more important for hyperspectral and multispectral remote sensing exploitation. Many solids are in the form of powders or granules and in order to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass or quartz for the ultraviolet (UV), visible or near-infrared spectral regions to prevent their unwanted dispersal into the instrument or laboratory environment. Using both experimental and theoretical methods we have found that for the case of fused quartz this leads to an intensity offset in the reflectance values. Although expected dispersive effects were observed for the fused quartz window in the UV, the measured hemispherical reflectance values are predominantly vertically shifted by the reflectance from the air-quartz and sample-quartz interfaces with intensity dependent offsets leading to measured values up to ∼6% too high for a 2% reflectance surface, ∼3.8% too high for 10% reflecting materials, approximately correct (to within experimental error) for 40% to 60% diffuse reflecting surfaces, and ∼2% too low for 99% reflecting Spectralon surfaces. For the diffuse reflectance case, the measured values are uniformly too low due to the glass, with differences nearly 6% too high for reflectance values approaching 99%. The deviations arise from the added reflections from the quartz surfaces as verified by theory, modeling and experiment. Empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300 nm to 2300 nm range.
- Open Access
- 13 September 2012
- Published by Hindawi Limited in International Journal of Spectroscopy
- Vol. 2012 (1) , 1-15
Design Considerations for a Portable Raman Probe Spectrometer for Field Forensics
Raman spectroscopy has been shown to be a viable method for explosives detection. Currently most forensic Raman systems are either large, powerful instruments for laboratory experiments or handheld instruments for in situ point detection. We have chosen to examine the performance of certain benchtop Raman probe systems with the goal of developing an inexpensive, portable system that could be used to operate in a field forensics laboratory to examine explosives-related residues or samples. To this end, a rugged, low distortion line imaging dispersive Raman spectrograph was configured to work at 830 nm laser excitation and was used to determine whether the composition of thin films of plastic explosives or small (e.g., ≤10 μm) particles of RDX or other explosives or oxidizers can be detected, identified, and quantified in the field. With 300 mW excitation energy, concentrations of RDX and PETN can be detected and reconstructed in the case of thin Semtex smears, but further work is needed to push detection limits of areal dosages to the ~1 μg/cm2 level. We describe the performance of several probe/spectrograph combinations and show preliminary data for particle detection, calibration and detection linearity for mixed compounds, and so forth.
- 13 September 2012
- Published by Hindawi Limited in International Journal of Spectroscopy
- Vol. 2012 (1) , 1-15
Open AccessDesign Considerations for a Portable Raman Probe Spectrometer for Field Forensics
Raman spectroscopy has been shown to be a viable method for explosives detection. Currently most forensic Raman systems are either large, powerful instruments for laboratory experiments or handheld instruments for in situ point detection. We have chosen to examine the performance of certain benchtop Raman probe systems with the goal of developing an inexpensive, portable system that could be used to operate in a field forensics laboratory to examine explosives-related residues or samples. To this end, a rugged, low distortion line imaging dispersive Raman spectrograph was configured to work at 830 nm laser excitation and was used to determine whether the composition of thin films of plastic explosives or small (e.g., ≤10 μm) particles of RDX or other explosives or oxidizers can be detected, identified, and quantified in the field. With 300 mW excitation energy, concentrations of RDX and PETN can be detected and reconstructed in the case of thin Semtex smears, but further work is needed to push detection limits of areal dosages to the ~1 μg/cm2 level. We describe the performance of several probe/spectrograph combinations and show preliminary data for particle detection, calibration and detection linearity for mixed compounds, and so forth.
- 6 October 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8189, 818908
Infrared signatures to discriminate viability of autoclaved Bacillus spores
Optical methods can offer good sensitivity for detecting small amounts of chemicals and biologicals, and as these methods mature, are some of the few techniques that can offer true standoff detection. For detection of biological species, determining the viability is clearly important: Certain species of gram-positive bacteria are capable of forming endospores, specialized structures that arise when living conditions become unfavorable or little growth medium is available. Spores are also resistant to many chemicals as well as changes in heat or pH; such spores can remain dormant from months to years until more favorable conditions arise, resulting in germination back to the vegetative state. This persistence characteristic of bacterial spores allows for contamination of a surface (e.g. food or medical equipment) even after the surface has been nominally cleaned. Bacterial spores have also been used as biological weapons, as in the case of B. anthracis. Thus, having rapid analytical methods to determine a spore's viability after attempts to clean a given environment is crucial. The increasing availability of portable spectrometers may provide a key to such rapid onsite analysis. The present study was designed to determine whether infrared spectroscopy may be used to differentiate between viable vs. dead B. subtilis and B. atrophaeus spores. Preliminary results show that the reproducible differences in the IR signatures can be used to identify the viable vs. the autoclaved (dead) spores.
- 6 October 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8189, 818908
Infrared signatures to discriminate viability of autoclaved Bacillus spores
Optical methods can offer good sensitivity for detecting small amounts of chemicals and biologicals, and as these methods mature, are some of the few techniques that can offer true standoff detection. For detection of biological species, determining the viability is clearly important: Certain species of gram-positive bacteria are capable of forming endospores, specialized structures that arise when living conditions become unfavorable or little growth medium is available. Spores are also resistant to many chemicals as well as changes in heat or pH; such spores can remain dormant from months to years until more favorable conditions arise, resulting in germination back to the vegetative state. This persistence characteristic of bacterial spores allows for contamination of a surface (e.g. food or medical equipment) even after the surface has been nominally cleaned. Bacterial spores have also been used as biological weapons, as in the case of B. anthracis. Thus, having rapid analytical methods to determine a spore's viability after attempts to clean a given environment is crucial. The increasing availability of portable spectrometers may provide a key to such rapid onsite analysis. The present study was designed to determine whether infrared spectroscopy may be used to differentiate between viable vs. dead B. subtilis and B. atrophaeus spores. Preliminary results show that the reproducible differences in the IR signatures can be used to identify the viable vs. the autoclaved (dead) spores.
- 26 May 2010
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 53 (1) , 28-33
The hydration number n of calcium dipicolinate trihydrate, CaDP·nH2O, and its effect on the IR spectra of sporulated Bacillus bacteria
- 26 May 2010
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 53 (1) , 28-33
The hydration number n of calcium dipicolinate trihydrate, CaDP·nH2O, and its effect on the IR spectra of sporulated Bacillus bacteria
- 1 August 2009
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 63 (8) , 908-915
The Infrared Spectra of Bacillus Bacteria Part II: Sporulated Bacillus—The Effect of Vegetative Cells and Contributions of Calcium Dipicolinate Trihydrate, CaDP-3H2O
Our previous paper showed that certain infrared (IR) peaks, e.g., the peak at 1739 cm−1, are due to varying (trace) amounts of vegetative cells amongst the Bacillus spores and that these and other vegetative bands are associated with lipid-soluble compounds, likely an ester or phospholipid. This work investigates the infrared spectra of eight different sporulated Bacillus bacteria. For the endospores it is observed that peaks at 1441, 1277, and 1015 cm−1 along with a distinct quartet of peaks at 766, 725, 701, and 659 cm−1 are clearly associated with calcium dipicolinate trihydrate, CaDP·3H2O. It is emphasized that the spore peaks, especially the quartet, arise from the calcium dipicolinate trihydrate and not from dipicolinic acid or other dipicolinate hydrate salts. The CaDP-3H2O infrared peaks and the effects of hydration are studied using quantum chemistry in the PQS software package. The quartet is associated with many modes including contributions from the Ca2+ counterion and hydration waters including Ca–O–H bends, H2O–Ca–O torsions, and O–C–O bends. The 1441 and 1015 cm−1 modes are planar pyridine modes with the 1441 cm−1 mode primarily a ring C–N stretch and the 1015 cm−1 mode primarily a ring C–C stretch.
- 1 August 2009
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 63 (8) , 908-915
The Infrared Spectra of Bacillus Bacteria Part II: Sporulated Bacillus—The Effect of Vegetative Cells and Contributions of Calcium Dipicolinate Trihydrate, CaDP-3H2O
Our previous paper showed that certain infrared (IR) peaks, e.g., the peak at 1739 cm−1, are due to varying (trace) amounts of vegetative cells amongst the Bacillus spores and that these and other vegetative bands are associated with lipid-soluble compounds, likely an ester or phospholipid. This work investigates the infrared spectra of eight different sporulated Bacillus bacteria. For the endospores it is observed that peaks at 1441, 1277, and 1015 cm−1 along with a distinct quartet of peaks at 766, 725, 701, and 659 cm−1 are clearly associated with calcium dipicolinate trihydrate, CaDP·3H2O. It is emphasized that the spore peaks, especially the quartet, arise from the calcium dipicolinate trihydrate and not from dipicolinic acid or other dipicolinate hydrate salts. The CaDP-3H2O infrared peaks and the effects of hydration are studied using quantum chemistry in the PQS software package. The quartet is associated with many modes including contributions from the Ca2+ counterion and hydration waters including Ca–O–H bends, H2O–Ca–O torsions, and O–C–O bends. The 1441 and 1015 cm−1 modes are planar pyridine modes with the 1441 cm−1 mode primarily a ring C–N stretch and the 1015 cm−1 mode primarily a ring C–C stretch.
- 1 August 2009
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 63 (8) , 899-907
The Infrared Spectra of Bacillus Bacteria Part I: Vegetative Bacillus versus Sporulated Cells and the Contributions of Phospholipids to Vegetative Infrared Spectra
This paper highlights the distinctions between the infrared (IR) absorption spectra of vegetative versus sporulated Bacillus bacteria. It is observed that there are unique signatures clearly associated with either the sporulated or vegetative state and that vegetative cells (or cell debris) can contribute to the spore spectra. A distinct feature at ∼1739 cm −1 appears to be unique to vegetative cell spectra and can also be used as an indicator of vegetative cells or cell debris in the spore spectra. The data indicate that the band arises from a lipid-soluble species such as an ester or phospholipid carbonyl bond and are consistent with it being either phosphatidyl glycerol (PG) or phosphatidylethanolamine (PE), two major classes of phospholipids found in vegetative cells of Bacillus species. A companion work discusses bands associated with the sporulated state.
- 1 August 2009
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 63 (8) , 899-907
The Infrared Spectra of Bacillus Bacteria Part I: Vegetative Bacillus versus Sporulated Cells and the Contributions of Phospholipids to Vegetative Infrared Spectra
This paper highlights the distinctions between the infrared (IR) absorption spectra of vegetative versus sporulated Bacillus bacteria. It is observed that there are unique signatures clearly associated with either the sporulated or vegetative state and that vegetative cells (or cell debris) can contribute to the spore spectra. A distinct feature at ∼1739 cm −1 appears to be unique to vegetative cell spectra and can also be used as an indicator of vegetative cells or cell debris in the spore spectra. The data indicate that the band arises from a lipid-soluble species such as an ester or phospholipid carbonyl bond and are consistent with it being either phosphatidyl glycerol (PG) or phosphatidylethanolamine (PE), two major classes of phospholipids found in vegetative cells of Bacillus species. A companion work discusses bands associated with the sporulated state.
- 12 May 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (2) , 377-386
Absolute integrated intensities of vapor-phase hydrogen peroxide (H2O2) in the mid-infrared at atmospheric pressure
We report quantitative infrared spectra of vapor-phase hydrogen peroxide (H2O2) with all spectra pressure-broadened to atmospheric pressure. The data were generated by injecting a concentrated solution (83%) of H2O2 into a gently heated disseminator and diluting it with pure N2 carrier gas. The water vapor lines were quantitatively subtracted from the resulting spectra to yield the spectrum of pure H2O2. The results for the ν6 band strength (including hot bands) compare favorably with the results of Klee et al. (J Mol. Spectrosc. 195:154, 1999 ) as well as with the HITRAN values. The present results are 433 and 467 cm-2 atm−1 (±8 and ±3% as measured at 298 and 323 K, respectively, and reduced to 296 K) for the band strength, matching well the value reported by Klee et al. (S = 467 cm−2 atm−1 at 296 K) for the integrated band. The ν1 + ν5 near-infrared band between 6,900 and 7,200 cm−1 has an integrated intensity S = 26.3 cm−2 atm−1, larger than previously reported values. Other infrared and near-infrared bands and their potential for atmospheric monitoring are discussed.
- 12 May 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (2) , 377-386
Absolute integrated intensities of vapor-phase hydrogen peroxide (H2O2) in the mid-infrared at atmospheric pressure
We report quantitative infrared spectra of vapor-phase hydrogen peroxide (H2O2) with all spectra pressure-broadened to atmospheric pressure. The data were generated by injecting a concentrated solution (83%) of H2O2 into a gently heated disseminator and diluting it with pure N2 carrier gas. The water vapor lines were quantitatively subtracted from the resulting spectra to yield the spectrum of pure H2O2. The results for the ν6 band strength (including hot bands) compare favorably with the results of Klee et al. (J Mol. Spectrosc. 195:154, 1999 ) as well as with the HITRAN values. The present results are 433 and 467 cm-2 atm−1 (±8 and ±3% as measured at 298 and 323 K, respectively, and reduced to 296 K) for the band strength, matching well the value reported by Klee et al. (S = 467 cm−2 atm−1 at 296 K) for the integrated band. The ν1 + ν5 near-infrared band between 6,900 and 7,200 cm−1 has an integrated intensity S = 26.3 cm−2 atm−1, larger than previously reported values. Other infrared and near-infrared bands and their potential for atmospheric monitoring are discussed.
- 1 January 2009
- Published by Optica Publishing Group
- p. FWA6
Absolute Infrared Cross Sections of Gas-Phase H2O2 Using Fourier Transform Mid-Infrared Spectroscopy
We report quantitative spectra of pressure-broadened H2O2 vapor. An 83% solution was flowed into a disseminator and diluted with N2 gas; water lines were subtracted. The H2O2 spectrum spans the IR and compares well with HITRAN values for ν6 band.
- 1 January 2009
- Published by Optica Publishing Group
- p. FWA6
Absolute Infrared Cross Sections of Gas-Phase H2O2 Using Fourier Transform Mid-Infrared Spectroscopy
We report quantitative spectra of pressure-broadened H2O2 vapor. An 83% solution was flowed into a disseminator and diluted with N2 gas; water lines were subtracted. The H2O2 spectrum spans the IR and compares well with HITRAN values for ν6 band.
- 1 October 2007
- Published by Office of Scientific and Technical Information (OSTI)
Feasibility Study of Using Short Wave Infrared Cavity Ringdown Spectroscopy (SWIR-CRDS) for Biological Agent Detection
This project focused on determining the feasibility of using short wave infrared (SWIR) cavity ring down spectroscopy (CRDS) as a means for real-time detection of biological aerosols. The first part of the project involved identifying biological agent signatures that could be detected with SWIR CRDS. After an exhaustive search of the open literature it was determined that whole biological spores and/or cells would not be good candidates for direct SWIR CRDS probing because they have no unique SWIR signatures. It was postulated that while whole cells or spores are not good candidates for SWIR CRDS detection, their pyrolysis break-down products might be. A literature search was then conducted to find biological pyrolysis products with low molecular weights and high symmetry since these species most likely would have overtone and combination vibrational bands that can be detected in the SWIR. It was determined that pyrrole, pyridine and picolinamide were good candidates for evaluation. These molecules are formed when proteins and porphyrins, proteins and dipicolinic acid, and dipicolinic acid are pyrolyzed, respectively. The second part of the project involved measuring quantitative SWIR spectra of pyrrole, pyridine and picolinamide in PNNL’s FTIR Spectroscopy Laboratory. Spectral information about these molecules, in the vapor phasemore » is sparse – there were only a few prior studies that measured line positions and no information on absorption cross sections. Absorption cross sections are needed in order to estimate the SWIR CRDS detection sensitivity, and line position determines what type of laser will be needed for the sensor. The results of the spectroscopy studies allowed us to estimate the SWIR CRDS detection sensitivity for pyrrole to be 3 x 1012 molec cm-3 or 0.1 ppmv, and for pyridine it was 1.5 x 1015 molec cm-3 or 0.6 ppmv. These detection sensitivity limits are close what we have measured for ammonia. Given these detection limits we then estimated the amount of biological material that would have to be collected for analysis in a sensor that combined pyrolysis with SWIR CRDS. Using conservative estimates of pyrolysis yields and precursor species concentration we determined that it would be necessary to collect and pyrolyze biological aerosol samples in the 10’s of mg. This is a large amount and is far larger than required for current sensors. It is therefore concluded that while possible, the large amounts of material required preclude using SWIR CRDS for detecting biological agents at this time.« less
- 1 October 2007
- Published by Office of Scientific and Technical Information (OSTI)
Feasibility Study of Using Short Wave Infrared Cavity Ringdown Spectroscopy (SWIR-CRDS) for Biological Agent Detection
This project focused on determining the feasibility of using short wave infrared (SWIR) cavity ring down spectroscopy (CRDS) as a means for real-time detection of biological aerosols. The first part of the project involved identifying biological agent signatures that could be detected with SWIR CRDS. After an exhaustive search of the open literature it was determined that whole biological spores and/or cells would not be good candidates for direct SWIR CRDS probing because they have no unique SWIR signatures. It was postulated that while whole cells or spores are not good candidates for SWIR CRDS detection, their pyrolysis break-down products might be. A literature search was then conducted to find biological pyrolysis products with low molecular weights and high symmetry since these species most likely would have overtone and combination vibrational bands that can be detected in the SWIR. It was determined that pyrrole, pyridine and picolinamide were good candidates for evaluation. These molecules are formed when proteins and porphyrins, proteins and dipicolinic acid, and dipicolinic acid are pyrolyzed, respectively. The second part of the project involved measuring quantitative SWIR spectra of pyrrole, pyridine and picolinamide in PNNL’s FTIR Spectroscopy Laboratory. Spectral information about these molecules, in the vapor phasemore » is sparse – there were only a few prior studies that measured line positions and no information on absorption cross sections. Absorption cross sections are needed in order to estimate the SWIR CRDS detection sensitivity, and line position determines what type of laser will be needed for the sensor. The results of the spectroscopy studies allowed us to estimate the SWIR CRDS detection sensitivity for pyrrole to be 3 x 1012 molec cm-3 or 0.1 ppmv, and for pyridine it was 1.5 x 1015 molec cm-3 or 0.6 ppmv. These detection sensitivity limits are close what we have measured for ammonia. Given these detection limits we then estimated the amount of biological material that would have to be collected for analysis in a sensor that combined pyrolysis with SWIR CRDS. Using conservative estimates of pyrolysis yields and precursor species concentration we determined that it would be necessary to collect and pyrolyze biological aerosol samples in the 10’s of mg. This is a large amount and is far larger than required for current sensors. It is therefore concluded that while possible, the large amounts of material required preclude using SWIR CRDS for detecting biological agents at this time.« less
- Open Access
- 4 July 2006
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 6 (9) , 2581-2591
The quantitative infrared and NIR spectrum of CH2I2 vapor: vibrational assignments and potential for atmospheric monitoring
Diiodomethane (CH2I2) has recently become a molecule of significant atmospheric interest as it can contribute to coastal IO formation. As part of the PNNL database of gas-phase infrared spectra, the quantitative absorption spectrum of CH2I2 has been acquired at 0.1 cm-1 resolution. Two strong b2 symmetry A-type bands at 584 and 1114 cm-1 are observed, but are not resolved when broadened to 760 Torr with nitrogen and appear as B-type. In contrast, the b1 symmetry C-type bands near 5953, 4426 and 3073 cm-1 are resolved with rotational structure, including Q-branches with widths ≤1 cm-1. The quantitative infrared and near-infrared vapor-phase spectra (600–10 000 cm-1) are reported for the first time. Some bands are discussed in terms of their potential for atmospheric monitoring and theoretical detection limits on a selected basis. FT-Raman spectra and ab initio calculations are used to complete vibrational assignments in the C2v point group.
- 4 July 2006
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 6 (9) , 2581-2591
Open AccessThe quantitative infrared and NIR spectrum of CH2I2 vapor: vibrational assignments and potential for atmospheric monitoring
Diiodomethane (CH2I2) has recently become a molecule of significant atmospheric interest as it can contribute to coastal IO formation. As part of the PNNL database of gas-phase infrared spectra, the quantitative absorption spectrum of CH2I2 has been acquired at 0.1 cm-1 resolution. Two strong b2 symmetry A-type bands at 584 and 1114 cm-1 are observed, but are not resolved when broadened to 760 Torr with nitrogen and appear as B-type. In contrast, the b1 symmetry C-type bands near 5953, 4426 and 3073 cm-1 are resolved with rotational structure, including Q-branches with widths ≤1 cm-1. The quantitative infrared and near-infrared vapor-phase spectra (600–10 000 cm-1) are reported for the first time. Some bands are discussed in terms of their potential for atmospheric monitoring and theoretical detection limits on a selected basis. FT-Raman spectra and ab initio calculations are used to complete vibrational assignments in the C2v point group.