Mitchell M. Goodsitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mitchell M. Goodsitt has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Heang-Ping Chan
Univ. of Michigan (United States)
12 shared publications - Lubomir M. Hadjiiski
Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
6 shared publications - Paul L. Carson
Department of Radiology, University of Michigan-Ann Arbor, 1500 E.Medical Center Drive, C474 Med-Inn Building, Ann Arbor, Michigan, 48109-1079, UNITED STATES
5 shared publications Emmanuel G. Christodoulou
4 shared publications- Berkman Sahiner
Univ. of Michigan (United States)
3 shared publications - Caroline E. Blane
Department of Radiology, University of Michigan Health System, 1500 East Medical Drive, Ann Arbor, MI 48109-0030, USA
3 shared publications
Latest Publications
- 13 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10139, 101390
Limited angle breast ultrasound tomography with a priori information and artifact removal
In B-mode images from dual-sided ultrasound, it has been shown that by delineating structures suspected of being relatively homogeneous, one can enhance limited angle tomography to produce speed of sound images in the same view as X-ray Digital Breast Tomography (DBT). This could allow better breast cancer detection and discrimination, as well as improved registration of the ultrasound and X-ray images, because of the similarity of SOS and X-ray contrast in the breast. However, this speed of sound reconstruction method relies strongly on B-mode or other reflection mode segmentation. If that information is limited or incorrect, artifacts will appear in the reconstructed images. Therefore, the iterative speed of sound reconstruction algorithm has been modified in a manner of simultaneously utilizing the image segmentations and removing most artifacts. The first step of incorporating a priori information is solved by any nonlinearnonconvex optimization method while artifact removal is accomplished by employing the fast split Bregman method to perform total-variation (TV) regularization for image denoising. The proposed method was demonstrated in simplified simulations of our dual-sided ultrasound scanner. To speed these computations two opposed 40-element ultrasound linear arrays with 0.5 MHz center frequency were simulated for imaging objects in a uniform background. The proposed speed of sound reconstruction method worked well with both bent-ray and full-wave inversion methods. This is also the first demonstration of successful full-wave medical ultrasound tomography in the limited angle geometry. Presented results lend credibility to a possible translation of this method to clinical breast imaging. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 13 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10139, 101390
Limited angle breast ultrasound tomography with a priori information and artifact removal
In B-mode images from dual-sided ultrasound, it has been shown that by delineating structures suspected of being relatively homogeneous, one can enhance limited angle tomography to produce speed of sound images in the same view as X-ray Digital Breast Tomography (DBT). This could allow better breast cancer detection and discrimination, as well as improved registration of the ultrasound and X-ray images, because of the similarity of SOS and X-ray contrast in the breast. However, this speed of sound reconstruction method relies strongly on B-mode or other reflection mode segmentation. If that information is limited or incorrect, artifacts will appear in the reconstructed images. Therefore, the iterative speed of sound reconstruction algorithm has been modified in a manner of simultaneously utilizing the image segmentations and removing most artifacts. The first step of incorporating a priori information is solved by any nonlinearnonconvex optimization method while artifact removal is accomplished by employing the fast split Bregman method to perform total-variation (TV) regularization for image denoising. The proposed method was demonstrated in simplified simulations of our dual-sided ultrasound scanner. To speed these computations two opposed 40-element ultrasound linear arrays with 0.5 MHz center frequency were simulated for imaging objects in a uniform background. The proposed speed of sound reconstruction method worked well with both bent-ray and full-wave inversion methods. This is also the first demonstration of successful full-wave medical ultrasound tomography in the limited angle geometry. Presented results lend credibility to a possible translation of this method to clinical breast imaging. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- Open Access
- 11 September 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (19) , 5883-5902
Digital breast tomosynthesis: studies of the effects of acquisition geometry on contrast-to-noise ratio and observer preference of low-contrast objects in breast phantom images
The effect of acquisition geometry in digital breast tomosynthesis was evaluated with studies of contrast-to-noise ratios (CNRs) and observer preference. Contrast-detail (CD) test objects in 5 cm thick phantoms with breast-like backgrounds were imaged. Twelve different angular acquisitions (average glandular dose for each ~1.1 mGy) were performed ranging from narrow angle 16° with 17 projection views (16d17p) to wide angle 64d17p. Focal slices of SART-reconstructed images of the CD arrays were selected for CNR computations and the reader preference study. For the latter, pairs of images obtained with different acquisition geometries were randomized and scored by 7 trained readers. The total scores for all images and readings for each acquisition geometry were compared as were the CNRs. In general, readers preferred images acquired with wide angle as opposed to narrow angle geometries. The mean percent preferred was highly correlated with tomosynthesis angle (R = 0.91). The highest scoring geometries were 60d21p (95%), 64d17p (80%), and 48d17p (72%); the lowest scoring were 16d17p (4%), 24d9p (17%) and 24d13p (33%). The measured CNRs for the various acquisitions showed much overlap but were overall highest for wide-angle acquisitions. Finally, the mean reader scores were well correlated with the mean CNRs (R = 0.83).
- 11 September 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (19) , 5883-5902
Open AccessDigital breast tomosynthesis: studies of the effects of acquisition geometry on contrast-to-noise ratio and observer preference of low-contrast objects in breast phantom images
The effect of acquisition geometry in digital breast tomosynthesis was evaluated with studies of contrast-to-noise ratios (CNRs) and observer preference. Contrast-detail (CD) test objects in 5 cm thick phantoms with breast-like backgrounds were imaged. Twelve different angular acquisitions (average glandular dose for each ~1.1 mGy) were performed ranging from narrow angle 16° with 17 projection views (16d17p) to wide angle 64d17p. Focal slices of SART-reconstructed images of the CD arrays were selected for CNR computations and the reader preference study. For the latter, pairs of images obtained with different acquisition geometries were randomized and scored by 7 trained readers. The total scores for all images and readings for each acquisition geometry were compared as were the CNRs. In general, readers preferred images acquired with wide angle as opposed to narrow angle geometries. The mean percent preferred was highly correlated with tomosynthesis angle (R = 0.91). The highest scoring geometries were 60d21p (95%), 64d17p (80%), and 48d17p (72%); the lowest scoring were 16d17p (4%), 24d9p (17%) and 24d13p (33%). The measured CNRs for the various acquisitions showed much overlap but were overall highest for wide-angle acquisitions. Finally, the mean reader scores were well correlated with the mean CNRs (R = 0.83).
- 9 April 2014
- Published by Wiley in Medical Physics
- Vol. 41 (5) , 051901
Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy
Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (similar to 17 x 17 mm) region of interest (ROI), 2 x 2, and 3 x 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2-1.3 times greater in the medium body than in the small body phantom and 1.3-1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 x 2 segmented subregions of the ROIs were 1.6-1.9 times greater than for no segmentation, and RMS errors for 3 x 3 segmented subregions were 2.3-2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 +/- 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 +/- 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 x 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa. (C) 2014 American Association of Physicists in Medicine.
- 9 April 2014
- Published by Wiley in Medical Physics
- Vol. 41 (5) , 051901
Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy
Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (similar to 17 x 17 mm) region of interest (ROI), 2 x 2, and 3 x 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2-1.3 times greater in the medium body than in the small body phantom and 1.3-1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 x 2 segmented subregions of the ROIs were 1.6-1.9 times greater than for no segmentation, and RMS errors for 3 x 3 segmented subregions were 2.3-2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 +/- 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 +/- 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 x 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa. (C) 2014 American Association of Physicists in Medicine.
- 29 March 2011
- Published by Wiley in Medical Physics
- Vol. 38 (4) , 2222-2232
Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner
Purpose:: This study was performed to investigate the accuracies of the synthesized monochromatic images and effective atomic number maps obtained with the new GE Discovery CT750 HD CT scanner.Methods:: A Gammex‐RMI model 467 tissue characterization phantom and the CT number linearity section of a Phantom Laboratory Catphan 600 phantom were scanned using the dual energy (DE) feature on the GE CT750 HD scanner. Synthesized monochromatic images at various energies between 40 and 120 keV and effective atomic numbermaps were generated. Regions of interest were placed within these images/maps to measure the average monochromatic CT numbers and averageof the materials within these phantoms. The truevalues were either supplied by the phantom manufacturer or computed using Mayneord's equation. The linear attenuation coefficients for the true CT numbers were computed using the NIST XCOM program with the input of manufacturer supplied elemental compositions and densities. The effects of small variations in the assumed true densities of the materials were also investigated. Finally, the effect of body size on the accuracies of the synthesized monochromatic CT numbers was investigated using a custom lumbar section phantom with and without an external fat‐mimicking ring.Results:: Other than theof the simulated lung inserts in the tissue characterization phantom, which could not be measured by DECT, thevalues of all of the other materials in the tissue characterization and Catphan phantoms were accurate to 15%. The accuracies of the synthesized monochromatic CT numbers of the materials in both phantoms varied with energy and material. For the 40–120 keV range, RMS errors between the measured and true CT numbers in the Catphan are 8–25 HU when the true CT numbers were computed using the nominal plastic densities. These RMS errors improve to 3–12 HU for assumed true densities within the nominal densityrange. The RMS errors between the measured and true CT numbers of the tissue mimicking materials in the tissue characterization phantom over the 40–120 keV range varied from about 6 HU–248 HU and did not improve as dramatically with small changes in assumed true density.Conclusions:: Initial tests indicate that thevalues computed with DECT on this scanner are reasonably accurate; however, the synthesized monochromatic CT numbers can be very inaccurate, especially for dense tissue mimicking materials at low energies. Furthermore, the synthesized monochromatic CT numbers of materials still depend on the amount of the surrounding tissues especially at low keV, demonstrating that the numbers are not truly monochromatic. Further research is needed to develop DE methods that produce more accurate synthesized monochromatic CT numbers.
- 29 March 2011
- Published by Wiley in Medical Physics
- Vol. 38 (4) , 2222-2232
Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner
Purpose:: This study was performed to investigate the accuracies of the synthesized monochromatic images and effective atomic number maps obtained with the new GE Discovery CT750 HD CT scanner.Methods:: A Gammex‐RMI model 467 tissue characterization phantom and the CT number linearity section of a Phantom Laboratory Catphan 600 phantom were scanned using the dual energy (DE) feature on the GE CT750 HD scanner. Synthesized monochromatic images at various energies between 40 and 120 keV and effective atomic numbermaps were generated. Regions of interest were placed within these images/maps to measure the average monochromatic CT numbers and averageof the materials within these phantoms. The truevalues were either supplied by the phantom manufacturer or computed using Mayneord's equation. The linear attenuation coefficients for the true CT numbers were computed using the NIST XCOM program with the input of manufacturer supplied elemental compositions and densities. The effects of small variations in the assumed true densities of the materials were also investigated. Finally, the effect of body size on the accuracies of the synthesized monochromatic CT numbers was investigated using a custom lumbar section phantom with and without an external fat‐mimicking ring.Results:: Other than theof the simulated lung inserts in the tissue characterization phantom, which could not be measured by DECT, thevalues of all of the other materials in the tissue characterization and Catphan phantoms were accurate to 15%. The accuracies of the synthesized monochromatic CT numbers of the materials in both phantoms varied with energy and material. For the 40–120 keV range, RMS errors between the measured and true CT numbers in the Catphan are 8–25 HU when the true CT numbers were computed using the nominal plastic densities. These RMS errors improve to 3–12 HU for assumed true densities within the nominal densityrange. The RMS errors between the measured and true CT numbers of the tissue mimicking materials in the tissue characterization phantom over the 40–120 keV range varied from about 6 HU–248 HU and did not improve as dramatically with small changes in assumed true density.Conclusions:: Initial tests indicate that thevalues computed with DECT on this scanner are reasonably accurate; however, the synthesized monochromatic CT numbers can be very inaccurate, especially for dense tissue mimicking materials at low energies. Furthermore, the synthesized monochromatic CT numbers of materials still depend on the amount of the surrounding tissues especially at low keV, demonstrating that the numbers are not truly monochromatic. Further research is needed to develop DE methods that produce more accurate synthesized monochromatic CT numbers.
- 28 February 2010
- Published by Elsevier in Academic Radiology
- Vol. 17 (2) , 142-145
New Compression Paddle for Wire Localization in Mammography
- 28 February 2010
- Published by Elsevier in Academic Radiology
- Vol. 17 (2) , 142-145
New Compression Paddle for Wire Localization in Mammography
- 11 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 3107-3121
Quantitative CT of lung nodules: Dependence of calibration on patient body size, anatomic region, and calibration nodule size for single‐ and dual‐energy techniques
Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more calcium reference standards. To account for CT number nonuniformity in the reconstruction field, such calibration lines may be obtained at multiple locations within lung regions in an anthropomorphic phantom. The authors performed a study to investigate the effects of patient body size, anatomic region, and calibration nodule size on the derived calibration lines at ten lung region positions using both single energy (SE) and dual energy (DE) CT techniques. Simulated spherical lung nodules of two concentrations (50 and 100 mg/cc CaCO 3 ) were employed. Nodules of three different diameters (4.8, 9.5, and 16 mm) were scanned in a simulated thorax section representing the middle of the chest with large lung regions. The 4.8 and 9.5 mm nodules were also scanned in a section representing the upper chest with smaller lung regions. Fat rings were added to the peripheries of the phantoms to simulate larger patients. Scans were acquired on a GE-VCT scanner at 80, 120, and 140 kVp and were repeated three times for each condition. The average absolute CT number separations between the calibration lines were computed. In addition, under- or overestimates were determined when the calibration lines for one condition (e.g., small patient) were used to estimate the CaCO 3 concentrations of nodules for a different condition (e.g., large patient). The authors demonstrated that, in general, DE is a more accurate method for estimating the calcium contents of lung nodules. The DE calibration lines within the lung field were less affected by patient body size, calibration nodule size, and nodule position than the SE calibration lines. Under- or overestimates in CaCO 3 concentrations of nodules were also in general smaller in quantity with DE than with SE. However, because the slopes of the calibration lines for DE were about one-half the slopes for SE, the relative improvement in the concentration estimates for DE as compared to SE was about one-half the relative improvement in the separation between the calibration lines. Results in the middle of the chest thorax section with large lungs were nearly completely consistent with the above generalization. On the other hand, results in the upper-chest thorax section with smaller lungs and greater amounts of muscle and bone were mixed. A repeat of the entire study in the upper thorax section yielded similar mixed results. Most of the inconsistencies occurred for the 4.8 mm nodules and may be attributed to errors caused by beam hardening, volume averaging, and insufficient sampling. Targeted, higher resolution reconstructions of the smaller nodules, application of high atomic number filters to the high energy x-ray beam for improved spectral separation, and other future developments in DECT may alleviate these problems and further substantiate the superior accuracy of DECT in quantifying the calcium concentrations of lung nodules.
- 11 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 3107-3121
Quantitative CT of lung nodules: Dependence of calibration on patient body size, anatomic region, and calibration nodule size for single‐ and dual‐energy techniques
Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more calcium reference standards. To account for CT number nonuniformity in the reconstruction field, such calibration lines may be obtained at multiple locations within lung regions in an anthropomorphic phantom. The authors performed a study to investigate the effects of patient body size, anatomic region, and calibration nodule size on the derived calibration lines at ten lung region positions using both single energy (SE) and dual energy (DE) CT techniques. Simulated spherical lung nodules of two concentrations (50 and 100 mg/cc CaCO 3 ) were employed. Nodules of three different diameters (4.8, 9.5, and 16 mm) were scanned in a simulated thorax section representing the middle of the chest with large lung regions. The 4.8 and 9.5 mm nodules were also scanned in a section representing the upper chest with smaller lung regions. Fat rings were added to the peripheries of the phantoms to simulate larger patients. Scans were acquired on a GE-VCT scanner at 80, 120, and 140 kVp and were repeated three times for each condition. The average absolute CT number separations between the calibration lines were computed. In addition, under- or overestimates were determined when the calibration lines for one condition (e.g., small patient) were used to estimate the CaCO 3 concentrations of nodules for a different condition (e.g., large patient). The authors demonstrated that, in general, DE is a more accurate method for estimating the calcium contents of lung nodules. The DE calibration lines within the lung field were less affected by patient body size, calibration nodule size, and nodule position than the SE calibration lines. Under- or overestimates in CaCO 3 concentrations of nodules were also in general smaller in quantity with DE than with SE. However, because the slopes of the calibration lines for DE were about one-half the slopes for SE, the relative improvement in the concentration estimates for DE as compared to SE was about one-half the relative improvement in the separation between the calibration lines. Results in the middle of the chest thorax section with large lungs were nearly completely consistent with the above generalization. On the other hand, results in the upper-chest thorax section with smaller lungs and greater amounts of muscle and bone were mixed. A repeat of the entire study in the upper thorax section yielded similar mixed results. Most of the inconsistencies occurred for the 4.8 mm nodules and may be attributed to errors caused by beam hardening, volume averaging, and insufficient sampling. Targeted, higher resolution reconstructions of the smaller nodules, application of high atomic number filters to the high energy x-ray beam for improved spectral separation, and other future developments in DECT may alleviate these problems and further substantiate the superior accuracy of DECT in quantifying the calcium concentrations of lung nodules.
- 1 May 2007
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 26 (5) , 645-655
Automated Ultrasound Scanning on a Dual-Modality Breast Imaging System
We are developing an automated ultrasound imaging-mammography system wherein a digital mammography unit has been augmented with a motorized ultrasound transducer carriage above a special compression paddle. Challenges of this system are acquiring complete coverage of the breast and minimizing motion. We assessed these problems and investigated methods to increase coverage and stabilize the compressed breast. Visual tracings of the breast-to-paddle contact area and breast periphery were made for 10 patients to estimate coverage area. Various motion artifacts were evaluated in 6 patients. Nine materials were tested for coupling the paddle to the breast. Fourteen substances were tested for coupling the transducer to the paddle in lateral-to-medial and medial-to-lateral views and filling the gap between the peripheral breast and paddle. In-house image registration software was used to register adjacent ultrasound sweeps. The average breast contact area was 56%. The average percentage of the peripheral air gap filled with ultrasound gel was 61%. Shallow patient breathing proved equivalent to breath holding, whereas speech and sudden breathing caused unacceptable artifacts. An adhesive spray that preserves image quality was found to be best for coupling the breast to the paddle and minimizing motion. A highly viscous ultrasound gel proved most effective for coupling the transducer to the paddle for lateral-to-medial and medial-to-lateral views and for edge fill-in. The challenges of automated ultrasound scanning in a multimodality breast imaging system have been addressed by developing methods to fill in peripheral gaps, minimize patient motion, and register and reconstruct multisweep ultrasound image volumes.
- 1 May 2007
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 26 (5) , 645-655
Automated Ultrasound Scanning on a Dual-Modality Breast Imaging System
We are developing an automated ultrasound imaging-mammography system wherein a digital mammography unit has been augmented with a motorized ultrasound transducer carriage above a special compression paddle. Challenges of this system are acquiring complete coverage of the breast and minimizing motion. We assessed these problems and investigated methods to increase coverage and stabilize the compressed breast. Visual tracings of the breast-to-paddle contact area and breast periphery were made for 10 patients to estimate coverage area. Various motion artifacts were evaluated in 6 patients. Nine materials were tested for coupling the paddle to the breast. Fourteen substances were tested for coupling the transducer to the paddle in lateral-to-medial and medial-to-lateral views and filling the gap between the peripheral breast and paddle. In-house image registration software was used to register adjacent ultrasound sweeps. The average breast contact area was 56%. The average percentage of the peripheral air gap filled with ultrasound gel was 61%. Shallow patient breathing proved equivalent to breath holding, whereas speech and sudden breathing caused unacceptable artifacts. An adhesive spray that preserves image quality was found to be best for coupling the breast to the paddle and minimizing motion. A highly viscous ultrasound gel proved most effective for coupling the transducer to the paddle for lateral-to-medial and medial-to-lateral views and for edge fill-in. The challenges of automated ultrasound scanning in a multimodality breast imaging system have been addressed by developing methods to fill in peripheral gaps, minimize patient motion, and register and reconstruct multisweep ultrasound image volumes.
- 27 July 2006
- Published by Wiley in Medical Physics
- Vol. 33 (8) , 3006-3017
Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners
A study was performed to determine the accuracies and reproducibilities of the CT numbers of simulated lung nodules imaged with multi‐detector CT scanners. The nodules were simulated by spherical bal...
- 27 July 2006
- Published by Wiley in Medical Physics
- Vol. 33 (8) , 3006-3017
Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners
A study was performed to determine the accuracies and reproducibilities of the CT numbers of simulated lung nodules imaged with multi‐detector CT scanners. The nodules were simulated by spherical bal...
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6142, 614249
Tomosynthesis reconstruction using the simultaneous algebraic reconstruction technique (SART) on breast phantom data
Digital tomosynthesis mammography (DTM) is a promising approach to breast cancer detection. DTM can provide 3D structural information of the breast tissue by reconstructing the imaged volume from 2D projections acquired at different angles in a limited angular range. In this work, we investigate the application of the Simultaneous Algebraic Reconstruction Technique (SART) to this limited-angle cone-beam tomographic problem. A second generation GE prototype tomosynthesis mammography system was used in this study. Projection-view images of different breast phantoms were acquired from 21 angles in 3° increments over a ±30° angular range. The digital detector is stationary during image acquisition. We used an ACR phantom and two additional phantoms to evaluate the image quality and reconstruction artifacts. The Back-Projection (BP) method was also implemented for comparison to SART. The contrast-to-noise ratio (CNR), line profile of features and an artifact spread function (ASF) were used to quantitatively evaluate the reconstruction results. Preliminary results show that both BP and SART can separate superimposed phantom structures along the Z direction, but SART is more effective in improving the conspicuity of tissue-mimicking details and suppressing interplane blurring. For the phantoms with homogeneous background, the BP method resulted in less noisy reconstruction and higher CNR values for masses than SART, but SART provided greater enhancement in the contrast of calcification clusters and the edge sharpness of masses and fibrils. It was shown that acceptable reconstruction can be achieved by SART after only one iteration.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6142, 614249
Tomosynthesis reconstruction using the simultaneous algebraic reconstruction technique (SART) on breast phantom data
Digital tomosynthesis mammography (DTM) is a promising approach to breast cancer detection. DTM can provide 3D structural information of the breast tissue by reconstructing the imaged volume from 2D projections acquired at different angles in a limited angular range. In this work, we investigate the application of the Simultaneous Algebraic Reconstruction Technique (SART) to this limited-angle cone-beam tomographic problem. A second generation GE prototype tomosynthesis mammography system was used in this study. Projection-view images of different breast phantoms were acquired from 21 angles in 3° increments over a ±30° angular range. The digital detector is stationary during image acquisition. We used an ACR phantom and two additional phantoms to evaluate the image quality and reconstruction artifacts. The Back-Projection (BP) method was also implemented for comparison to SART. The contrast-to-noise ratio (CNR), line profile of features and an artifact spread function (ASF) were used to quantitatively evaluate the reconstruction results. Preliminary results show that both BP and SART can separate superimposed phantom structures along the Z direction, but SART is more effective in improving the conspicuity of tissue-mimicking details and suppressing interplane blurring. For the phantoms with homogeneous background, the BP method resulted in less noisy reconstruction and higher CNR values for masses than SART, but SART provided greater enhancement in the contrast of calcification clusters and the edge sharpness of masses and fibrils. It was shown that acceptable reconstruction can be achieved by SART after only one iteration.