Christoph Hehrlein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christoph Hehrlein has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Amina Arab
Department of Cardiology and Angiology, University of Freiburg, Freiburg, Germany
2 shared publicationsMarc Kollum
Department of Cardiology and Angiology, University of Freiburg, Freiburg, Germany
2 shared publicationsAndrea Geist
Department of Experimental Surgery, University of Freiburg, Freiburg, Germany
1 shared publicationAndrew Farb
Department of Cardiovascular Pathology, Armed Forced Institute of Pathology, Washington, District of Columbia
1 shared publicationHuse Kamencic
Department of Anatomy and Cell Biology, University of Heidelberg, Germany
1 shared publicationJörg Haberstroh
Department of Experimental Surgery, University of Freiburg, Freiburg, Germany
1 shared publication
Latest Publications
- 29 September 2010
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 76 (4) , 511-512
Quantitative myocardial blush grade: Prepped for a core lab standardization
- 29 September 2010
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 76 (4) , 511-512
Quantitative myocardial blush grade: Prepped for a core lab standardization
- 27 March 2007
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (5) , 739
Promises of biodegradable stents
- 27 March 2007
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (5) , 739
Promises of biodegradable stents
- 23 December 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 64 (1) , 85-90
Particle debris from a nanoporous stent coating obscures potential antiproliferative effects of tacrolimus-eluting stents in a porcine model of restenosis
Polymer stent coatings may not be suitable for drug elution because of inherent proinflammatory effects. A previous study suggested a beneficial effect of a stent eluting tacrolimus from a nanoporous ceramic aluminum oxide coating in a rabbit restenosis model. We investigated whether this stent is effective in preventing in‐stent restenosis in a porcine restenosis model. Thirty‐four juvenile swine underwent balloon overstretch injury and were subjected to implantation of either stainless steel (bare) stents, bare stents coated with nanoporous aluminum oxide alone, and coated stents eluting 50 and 180 μg of tacrolimus (FK506). In‐stent restenosis was quantified at 1 and 3 months after stent placement by histomorphometry. A significant increase of neointimal hyperplasia was noted with the stents coated with aluminum oxide alone compared with bare stents (2.92 ± 1.02 and 1.38 ± 0.51 mm2, respectively; P < 0.02). In all arteries containing coated stents, particle debris was found in the media and neointima, resulting in augmented vascular inflammation. In the group of stents coated with aluminum oxide, FK506 elution at a dose 180 μg reduced neointimal hyperplasia vs. no drug elution (1.66 ± 0.49 vs. 2.92 ± 1.02 mm2; 180 μg vs. ceramic alone; P < 0.03). At a dose of 50 μg stent‐based delivery of FK506, no reduction of neointimal hyperplasia was found (2.88 ± 1.31 and 2.92 ± 1.02 mm2, respectively; P = NS; FK506 vs. ceramic alone). In summary, particle debris shed from a drug‐eluting aluminum oxide coating of a stainless steel stent counteracts potential antiproliferative effects of stent‐based tacrolimus delivery in a porcine model of restenosis. We propose that stent coatings eluting drugs need to be routinely tested for being tightly anchored into the stent surface. Alternatively, omission of any coating used as a drug reservoir may eliminate inflammatory particle debris after placement of drug‐eluting stents. Catheter Cardiovasc Interv 2005;64:85–90.
- 23 December 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 64 (1) , 85-90
Particle debris from a nanoporous stent coating obscures potential antiproliferative effects of tacrolimus-eluting stents in a porcine model of restenosis
Polymer stent coatings may not be suitable for drug elution because of inherent proinflammatory effects. A previous study suggested a beneficial effect of a stent eluting tacrolimus from a nanoporous ceramic aluminum oxide coating in a rabbit restenosis model. We investigated whether this stent is effective in preventing in‐stent restenosis in a porcine restenosis model. Thirty‐four juvenile swine underwent balloon overstretch injury and were subjected to implantation of either stainless steel (bare) stents, bare stents coated with nanoporous aluminum oxide alone, and coated stents eluting 50 and 180 μg of tacrolimus (FK506). In‐stent restenosis was quantified at 1 and 3 months after stent placement by histomorphometry. A significant increase of neointimal hyperplasia was noted with the stents coated with aluminum oxide alone compared with bare stents (2.92 ± 1.02 and 1.38 ± 0.51 mm2, respectively; P < 0.02). In all arteries containing coated stents, particle debris was found in the media and neointima, resulting in augmented vascular inflammation. In the group of stents coated with aluminum oxide, FK506 elution at a dose 180 μg reduced neointimal hyperplasia vs. no drug elution (1.66 ± 0.49 vs. 2.92 ± 1.02 mm2; 180 μg vs. ceramic alone; P < 0.03). At a dose of 50 μg stent‐based delivery of FK506, no reduction of neointimal hyperplasia was found (2.88 ± 1.31 and 2.92 ± 1.02 mm2, respectively; P = NS; FK506 vs. ceramic alone). In summary, particle debris shed from a drug‐eluting aluminum oxide coating of a stainless steel stent counteracts potential antiproliferative effects of stent‐based tacrolimus delivery in a porcine model of restenosis. We propose that stent coatings eluting drugs need to be routinely tested for being tightly anchored into the stent surface. Alternatively, omission of any coating used as a drug reservoir may eliminate inflammatory particle debris after placement of drug‐eluting stents. Catheter Cardiovasc Interv 2005;64:85–90.
- 1 August 1999
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 12 (4) , 299-304
Increased Apoptotic Cell Death in the Neointima after Stent-Based Vascular Irradiation: Role of Radiation-Induced Apoptosis for Restenosis Reduction
- 1 August 1999
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 12 (4) , 299-304
Increased Apoptotic Cell Death in the Neointima after Stent-Based Vascular Irradiation: Role of Radiation-Induced Apoptosis for Restenosis Reduction