Joe H. Chow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joe H. Chow has a total of 154 co-authors. Here are the top co-authors by number of shared publications:
- Denis Osipov
New York Power Authority
23 shared publications - Felipe Wilches-Bernal
Former employee of Sandia National Laboratories
19 shared publications - Daniel J. Trudnowski
Electrical Engineering Department, Montana Technological University, Butte, MT, USA
16 shared publications Graham Rogers
Cherry Tree Scientific Software
16 shared publications- Ryan Thomas Elliott
Sandia National Laboratories
16 shared publications - Meng Wang
Rensselaer Polytechnic Institute, Troy, NY, USA
11 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4626-4640
Analytical Framework for Assessing Effective Regional Inertia
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4626-4640
Analytical Framework for Assessing Effective Regional Inertia
- Open Access
- 15 July 2026
- Published by Elsevier in SSRN Electronic Journal
Electricity Market Clearing with Renewable Resources Bidding Risk-adjusted Cost Curves
Renewable power generators typically participate as price-takers in current electricity markets, and market clearing prices are determined by cost curves of conventional generators while treating renewable generation as negative load. In this paper, we analyze a new design of electricity markets where renewable power generators bid their risk-adjusted cost curves into the market, just like the cost curves of conventional generators. We establish that on average, the total revenue of both conventional and renewable generators, as well as the total cost to consumers, under the proposed market is the same as that in current practice. However, compared to current practice, the variability in the total consumer cost is always lower in the proposed market, i.e., the risk of price variability due to uncertainty in renewable generation is not borne by the consumers. Further, under certain operating conditions, the proposed market also results in lower variability in the revenue earned by the renewable generators. We then show how these cost curves should be adjusted to incorporate the risk of shortfall into the bidding and unit commitment process through the Conditional Value-at-Risk (CVaR) metric. Using data from the Texas grid, we evaluate the bid curves for renewables and quantify the tradeoff between renewable revenue and cost-to-load. We also study how CVaR-based adjustments for shortfall risk impact allocations and payments at market clearing. While equivalent in terms of average cost and revenue measures, the new market design insulates customers from the price risk associated with the uncertainty of renewable power generation. Further, it allows renewables to be direct participants in the bidding process and bid according to their risk-return tolerance level.
- 15 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessElectricity Market Clearing with Renewable Resources Bidding Risk-adjusted Cost Curves
Renewable power generators typically participate as price-takers in current electricity markets, and market clearing prices are determined by cost curves of conventional generators while treating renewable generation as negative load. In this paper, we analyze a new design of electricity markets where renewable power generators bid their risk-adjusted cost curves into the market, just like the cost curves of conventional generators. We establish that on average, the total revenue of both conventional and renewable generators, as well as the total cost to consumers, under the proposed market is the same as that in current practice. However, compared to current practice, the variability in the total consumer cost is always lower in the proposed market, i.e., the risk of price variability due to uncertainty in renewable generation is not borne by the consumers. Further, under certain operating conditions, the proposed market also results in lower variability in the revenue earned by the renewable generators. We then show how these cost curves should be adjusted to incorporate the risk of shortfall into the bidding and unit commitment process through the Conditional Value-at-Risk (CVaR) metric. Using data from the Texas grid, we evaluate the bid curves for renewables and quantify the tradeoff between renewable revenue and cost-to-load. We also study how CVaR-based adjustments for shortfall risk impact allocations and payments at market clearing. While equivalent in terms of average cost and revenue measures, the new market design insulates customers from the price risk associated with the uncertainty of renewable power generation. Further, it allows renewables to be direct participants in the bidding process and bid according to their risk-return tolerance level.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Markets, Policy and Regulation
- Vol. 4 (1) , 93-105
Unit Commitment With Risk-Adjusted Tranching of Renewable Energy Resources
This paper presents a risk segmentation approach for scheduling generation in power systems with high penetration of renewable energy resources (RERs). This approach aims to facilitate risk-adjusted participation of RERs in the day-ahead market (DAM). It borrows from debt securitization techniques to define risk tranches and develops separate bid curves of RERs by the tranches of different grades of risk. Assigning a higher price to a tranche with greater risk can prevent a renewable asset owner from incurring losses when the asset cannot produce the day-ahead committed amount of energy and must buy energy from the real-time market (RTM). In the proposed approach, the system operator utilizes the risk-segmented bids from RERs and generation reliability constraints to solve a risk-adjusted unit commitment (UC) problem. To a system operator, this can be treated as a deterministic DAM dispatch. The stochasticity of this UC problem is embedded in the renewable bid curves. The resulting increase in DAM revenues due to additional DAM commitment benefits the renewable asset owners. The loads can also benefit from additional RER commitment in DAM as it lowers DAM energy prices. The paper will focus on using this risk-adjusted strategy for wind energy resources. The approach is illustrated on a synthetic 6,700- bus model of the 2030 Electric Reliability Council of Texas (ERCOT) system that has a significant penetration of wind resources.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Markets, Policy and Regulation
- Vol. 4 (1) , 93-105
Unit Commitment With Risk-Adjusted Tranching of Renewable Energy Resources
This paper presents a risk segmentation approach for scheduling generation in power systems with high penetration of renewable energy resources (RERs). This approach aims to facilitate risk-adjusted participation of RERs in the day-ahead market (DAM). It borrows from debt securitization techniques to define risk tranches and develops separate bid curves of RERs by the tranches of different grades of risk. Assigning a higher price to a tranche with greater risk can prevent a renewable asset owner from incurring losses when the asset cannot produce the day-ahead committed amount of energy and must buy energy from the real-time market (RTM). In the proposed approach, the system operator utilizes the risk-segmented bids from RERs and generation reliability constraints to solve a risk-adjusted unit commitment (UC) problem. To a system operator, this can be treated as a deterministic DAM dispatch. The stochasticity of this UC problem is embedded in the renewable bid curves. The resulting increase in DAM revenues due to additional DAM commitment benefits the renewable asset owners. The loads can also benefit from additional RER commitment in DAM as it lowers DAM energy prices. The paper will focus on using this risk-adjusted strategy for wind energy resources. The approach is illustrated on a synthetic 6,700- bus model of the 2030 Electric Reliability Council of Texas (ERCOT) system that has a significant penetration of wind resources.
- Open Access
Analytical Framework for Assessing Effective Regional Inertia
This paper proposes a novel formulation of effective regional inertia that explicitly accounts for both system topology and the spatial distribution of inertia. Unlike traditional approaches that model a region as an aggregated machine with an equivalent inertia, the proposed metric provides a topology-aware representation. The methodology builds on an analytical framework that extends classical slow coherency theory to address network partitioning and regional frequency stability. Based on these partitions, we develop a systematic procedure to evaluate the effective inertia of each region, enabling a more accurate interpretation of local inertial contributions, including those from virtual inertia provided by inverter-based resources (IBRs). Case studies on the IEEE 39-bus and 68-bus systems demonstrate that the integration of inertial devices does not uniformly improve system frequency response, underscoring the importance of the proposed metric for effective regional inertia assessment.
Open AccessAnalytical Framework for Assessing Effective Regional Inertia
This paper proposes a novel formulation of effective regional inertia that explicitly accounts for both system topology and the spatial distribution of inertia. Unlike traditional approaches that model a region as an aggregated machine with an equivalent inertia, the proposed metric provides a topology-aware representation. The methodology builds on an analytical framework that extends classical slow coherency theory to address network partitioning and regional frequency stability. Based on these partitions, we develop a systematic procedure to evaluate the effective inertia of each region, enabling a more accurate interpretation of local inertial contributions, including those from virtual inertia provided by inverter-based resources (IBRs). Case studies on the IEEE 39-bus and 68-bus systems demonstrate that the integration of inertial devices does not uniformly improve system frequency response, underscoring the importance of the proposed metric for effective regional inertia assessment.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 23 (9) , 787-798
Data-Driven Power System Linear Model Identification via Quadrature-Based Balanced Truncation
This paper introduces the novel formulation of the quadrature-based balanced truncation (QBBT) method to precisely identify large-scale power system linear models. The QBBT interpolates a directional frequency dataset that is extracted from a dynamic system, following a quadrature rule to be applied from weighted data to derive a linear system model based on approximations of Gramians, and providing an alternative approach to the classic balanced truncation (BT) formulation that makes use of the system model. In this investigation, an accurate theoretical framework is presented to achieve the application of QBBT considering power systems as black-box models. The Boyd/Clenshaw-Curtis (BCC) quadrature rule is implemented by using different adjustments to accurately identify linear models of different order. The attained results and their validation with analytical power system models confirm the method's potential to retail oscillatory dynamics. The QBBT's effectiveness is compared with the Loewner-based frequency interpolation (LBFI) approach and the BT method on the Klein-Rogers-Kundur (KRK) benchmark power system and the equivalent of the New England transmission system - New York power system (NETS-NYPS), achieving a small absolute error in the magnitude of the frequency response of the models of the order of 1x10-3 dB in comparison with other state-of-the-art methods.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 23 (9) , 787-798
Data-Driven Power System Linear Model Identification via Quadrature-Based Balanced Truncation
This paper introduces the novel formulation of the quadrature-based balanced truncation (QBBT) method to precisely identify large-scale power system linear models. The QBBT interpolates a directional frequency dataset that is extracted from a dynamic system, following a quadrature rule to be applied from weighted data to derive a linear system model based on approximations of Gramians, and providing an alternative approach to the classic balanced truncation (BT) formulation that makes use of the system model. In this investigation, an accurate theoretical framework is presented to achieve the application of QBBT considering power systems as black-box models. The Boyd/Clenshaw-Curtis (BCC) quadrature rule is implemented by using different adjustments to accurately identify linear models of different order. The attained results and their validation with analytical power system models confirm the method's potential to retail oscillatory dynamics. The QBBT's effectiveness is compared with the Loewner-based frequency interpolation (LBFI) approach and the BT method on the Klein-Rogers-Kundur (KRK) benchmark power system and the equivalent of the New England transmission system - New York power system (NETS-NYPS), achieving a small absolute error in the magnitude of the frequency response of the models of the order of 1x10-3 dB in comparison with other state-of-the-art methods.
- Open Access
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Unit Commitment with Risk-adjusted Tranching of Renewable Energy Resources
This paper presents a risk segmentation approach for scheduling generation in power systems with high penetration of renewable energy resources (RERs). This approach aims to facilitate risk-adjusted participation of RERs in the day-ahead market (DAM). It borrows from debt securitization techniques to define risk tranches and develops separate bid curves of RERs by the tranches of different grades of risk. Assigning a higher price to a tranche with greater risk can prevent a renewable asset owner from incurring losses when the asset cannot produce the day-ahead committed amount of energy and must buy energy from the real-time market (RTM). In the proposed approach, the system operator utilizes the risk-segmented bids from RERs and generation reliability constraints to solve a risk-adjusted unit commitment problem. The resulting increase in DAM revenues due to additional DAM commitment benefits the renewable asset owners. The loads can also benefit from additional RER commitment in DAM as it lowers DAM energy prices. The paper will focus on using this risk-adjusted strategy for wind energy resources. The approach is illustrated on a synthetic 6,700-bus model of the 2030 Electric Reliability Council of Texas (ERCOT) system that has a significant penetration of wind resources.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessUnit Commitment with Risk-adjusted Tranching of Renewable Energy Resources
This paper presents a risk segmentation approach for scheduling generation in power systems with high penetration of renewable energy resources (RERs). This approach aims to facilitate risk-adjusted participation of RERs in the day-ahead market (DAM). It borrows from debt securitization techniques to define risk tranches and develops separate bid curves of RERs by the tranches of different grades of risk. Assigning a higher price to a tranche with greater risk can prevent a renewable asset owner from incurring losses when the asset cannot produce the day-ahead committed amount of energy and must buy energy from the real-time market (RTM). In the proposed approach, the system operator utilizes the risk-segmented bids from RERs and generation reliability constraints to solve a risk-adjusted unit commitment problem. The resulting increase in DAM revenues due to additional DAM commitment benefits the renewable asset owners. The loads can also benefit from additional RER commitment in DAM as it lowers DAM energy prices. The paper will focus on using this risk-adjusted strategy for wind energy resources. The approach is illustrated on a synthetic 6,700-bus model of the 2030 Electric Reliability Council of Texas (ERCOT) system that has a significant penetration of wind resources.
- 4 February 2025
- Published by Springer Nature
- p. 89-105
Power System Structure and Oscillations
- 4 February 2025
- Published by Springer Nature
- p. 9-28
The Nature of Power System Oscillations
- 4 February 2025
- Published by Springer Nature
- p. 331-348
Forced Oscillations
- 4 February 2025
- Published by Springer Nature
- p. 1-6
Introduction