Natacha Gentile
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Natacha Gentile has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Olivier Delémont
Ecole des Sciences Criminelles, Université de Lausanne, Batochime, 1015 Lausanne-Dorigny, Switzerland
4 shared publications- Rolf T. W. Siegwolf
Swiss Federal Institute for Forest Snow and Landscape Research WSL Birmensdorf 8903 Switzerland
3 shared publications Pierre Esseiva
Ecole des Sciences Criminelles, Université de Lausanne, Batochime, 1015 Lausanne-Dorigny, Switzerland
2 shared publicationsDiego Pazos
1 shared publication- Kurt Zollinger
Forensic Science Institute Zurich, 8004 Zurich, Switzerland
1 shared publication Luc Besson
1 shared publication
Latest Publications
- 1 June 2015
- Published by Elsevier in Forensic Science International
- Vol. 251, 139-158
Isotope ratio mass spectrometry as a tool for source inference in forensic science: A critical review
- 1 June 2015
- Published by Elsevier in Forensic Science International
- Vol. 251, 139-158
Isotope ratio mass spectrometry as a tool for source inference in forensic science: A critical review
- 26 October 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (1) , 159-176
δ 15N measurement of organic and inorganic substances by EA-IRMS: a speciation-dependent procedure
Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ 15N by elemental analysis (EA)–isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ 15N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH4NO3) and potassium nitrate (KNO3) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2—two ammonium sulphates [(NH4)2SO4]—and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V2O5) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ 15N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards. Control chart of the δ 15N value of IAEA-N1, IAEA-NO-3 and NH4NO3 analysed a) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 18 s/20 s), b) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 0 s/2 s and 5 s/7 s), c) without oxygen injection (analytical cycle 70 s, sample start and stop at 18 s/20 s).
- 26 October 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (1) , 159-176
δ 15N measurement of organic and inorganic substances by EA-IRMS: a speciation-dependent procedure
Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ 15N by elemental analysis (EA)–isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ 15N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH4NO3) and potassium nitrate (KNO3) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2—two ammonium sulphates [(NH4)2SO4]—and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V2O5) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ 15N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards. Control chart of the δ 15N value of IAEA-N1, IAEA-NO-3 and NH4NO3 analysed a) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 18 s/20 s), b) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 0 s/2 s and 5 s/7 s), c) without oxygen injection (analytical cycle 70 s, sample start and stop at 18 s/20 s).
- 1 October 2011
- Published by Elsevier in Forensic Science International
- Vol. 212 (1-3) , 260-271
On the use of IRMS in forensic science: Proposals for a methodological approach
- 1 October 2011
- Published by Elsevier in Forensic Science International
- Vol. 212 (1-3) , 260-271
On the use of IRMS in forensic science: Proposals for a methodological approach
- 14 July 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (16) , 2559-2567
Study of isotopic variations in black powder: reflections on the use of stable isotopes in forensic science for source inference
Isotope ratio mass spectrometry (IRMS) has recently made its appearance in the forensic community. This high‐precision technology has already been applied to a broad range of forensic fields such as illicit drugs, explosives and flammable liquids, where current, routinely used techniques have limited powers of discrimination. The conclusions drawn from the majority of these IRMS studies appear to be very promising. Used in a comparative process, as in food or drug authentication, the measurement of stable isotope ratios is a new and remarkable analytical tool for the discrimination or the identification of a substance with a definite source or origin. However, the research consists mostly of preliminary studies. The significance of this ‘new’ piece of information needs to be evaluated in light of a forensic framework to assess the actual potential and validity of IRMS, considering the characteristics of each field. Through the isotopic study of black powder, this paper aims at illustrating the potential of the method and the limitations of current knowledge in stable isotopes when facing forensic problems. Copyright © 2009 John Wiley & Sons, Ltd.
- 14 July 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (16) , 2559-2567
Study of isotopic variations in black powder: reflections on the use of stable isotopes in forensic science for source inference
Isotope ratio mass spectrometry (IRMS) has recently made its appearance in the forensic community. This high‐precision technology has already been applied to a broad range of forensic fields such as illicit drugs, explosives and flammable liquids, where current, routinely used techniques have limited powers of discrimination. The conclusions drawn from the majority of these IRMS studies appear to be very promising. Used in a comparative process, as in food or drug authentication, the measurement of stable isotope ratios is a new and remarkable analytical tool for the discrimination or the identification of a substance with a definite source or origin. However, the research consists mostly of preliminary studies. The significance of this ‘new’ piece of information needs to be evaluated in light of a forensic framework to assess the actual potential and validity of IRMS, considering the characteristics of each field. Through the isotopic study of black powder, this paper aims at illustrating the potential of the method and the limitations of current knowledge in stable isotopes when facing forensic problems. Copyright © 2009 John Wiley & Sons, Ltd.