Xinzhen Du
Research Subjects
Xinzhen Du has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Dongxia Zhang
College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China
4 shared publicationsLi Li
College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China; College of Science, Gansu Agriculture University, Lanzhou 730070, PR China
3 shared publicationsRuibin Guo
College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China
3 shared publicationsXuemei Wang
College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China; Key Lab of Bioelectrochemistry & Environmental Analysis of Gansu, Lanzhou 730070, PR China
3 shared publicationsYi Li
College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China
3 shared publicationsLin-Ke Xue
2 shared publications
Latest Publications
- 1 March 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 867, 38-46
In situ growth and phenyl functionalization of titania nanoparticles coating for solid-phase microextraction of ultraviolet filters in environmental water samples followed by high performance liquid chromatography–UV detection
- 1 March 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 867, 38-46
In situ growth and phenyl functionalization of titania nanoparticles coating for solid-phase microextraction of ultraviolet filters in environmental water samples followed by high performance liquid chromatography–UV detection
- 28 November 2014
- Published by Elsevier in Applied Surface Science
- Vol. 328, 26-33
Excellent adsorption of ultraviolet filters using silylated MCM-41 mesoporous materials as adsorbent
- 28 November 2014
- Published by Elsevier in Applied Surface Science
- Vol. 328, 26-33
Excellent adsorption of ultraviolet filters using silylated MCM-41 mesoporous materials as adsorbent
- 1 October 2014
- Published by Wiley in Luminescence
- Vol. 30 (5) , 512-518
A novel system of galangin–potassium permanganate–polyphosphoric acid for the determination of tryptophan and its chemiluminescence mechanism
A novel galangin–potassium permanganate (KMnO4)–polyphosphoric acid (PPA) system was found to have an outstanding response to tryptophan (Trp). Trp determination using this KMnO4–PPA system was enhanced significantly in the presence of galangin. A highly sensitive flow‐injection chemiluminescence (CL) method to determine Trp was developed based on the CL reaction of galangin–KMnO4–Trp in PPA media. The presence of galangin, a member of the flavonol class of flavonoid complexes, greatly increased the luminous intensity of Trp in KMnO4–PPA systems. Under optimized conditions, Trp was determined in the 0.05–10 µg/mL range, with a detection limit (3σ) of 5.0 × 10−3 µg/mL. The relative standard deviation (RSD) was 1.0% for 11 replicate determinations of 1.0 µg/mL Trp. Two synthetic samples were determined selectively with recoveries of 98.4–100.1% in the presence of other amino acids. The possible mechanism is summarized as follows: excited states of Mn(II)* and Mn(III * types are the main means of generating chemical luminescent species, and Trp concentration and luminescence intensity have a linear relationship, which enables quantitative analysis. Copyright © 2014 John Wiley & Sons, Ltd.
- 1 October 2014
- Published by Wiley in Luminescence
- Vol. 30 (5) , 512-518
A novel system of galangin–potassium permanganate–polyphosphoric acid for the determination of tryptophan and its chemiluminescence mechanism
A novel galangin–potassium permanganate (KMnO4)–polyphosphoric acid (PPA) system was found to have an outstanding response to tryptophan (Trp). Trp determination using this KMnO4–PPA system was enhanced significantly in the presence of galangin. A highly sensitive flow‐injection chemiluminescence (CL) method to determine Trp was developed based on the CL reaction of galangin–KMnO4–Trp in PPA media. The presence of galangin, a member of the flavonol class of flavonoid complexes, greatly increased the luminous intensity of Trp in KMnO4–PPA systems. Under optimized conditions, Trp was determined in the 0.05–10 µg/mL range, with a detection limit (3σ) of 5.0 × 10−3 µg/mL. The relative standard deviation (RSD) was 1.0% for 11 replicate determinations of 1.0 µg/mL Trp. Two synthetic samples were determined selectively with recoveries of 98.4–100.1% in the presence of other amino acids. The possible mechanism is summarized as follows: excited states of Mn(II)* and Mn(III * types are the main means of generating chemical luminescent species, and Trp concentration and luminescence intensity have a linear relationship, which enables quantitative analysis. Copyright © 2014 John Wiley & Sons, Ltd.
- 1 September 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (21) , 8519-8525
Fabrication of a novel Ti–TiO2–ZrO2 fiber for solid-phase microextraction followed by high-performance liquid chromatography for sensitive determination of UV filters in environmental water samples
A novel ZrO2 nanoparticle coated TiO2-based fiber for solid-phase microextraction was fabricated for sensitive determination of ultraviolet filters in environmental water samples.
- 1 September 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (21) , 8519-8525
Fabrication of a novel Ti–TiO2–ZrO2 fiber for solid-phase microextraction followed by high-performance liquid chromatography for sensitive determination of UV filters in environmental water samples
A novel ZrO2 nanoparticle coated TiO2-based fiber for solid-phase microextraction was fabricated for sensitive determination of ultraviolet filters in environmental water samples.
- 8 August 2014
- Published by Taylor & Francis in Analytical Letters
- Vol. 47 (15) , 2508-2521
Evaluation of the Counter Ions in Doped Porous Polyaniline Coatings on Stainless Steel Wires for Solid Phase Microextraction of Chlorophenolics in Water Combined with High-Performance Liquid Chromatography
Porous polyaniline coatings doped with different counter ions were electrodeposited on the surface of stainless steel wires using controlled potentiostatic coulometry. Prior to electropolymerization, the stainless steel wires were chemically etched to improve subsequent immobilization of the polyaniline coatings on the substrate and to increase the effective surface area. Porous polyaniline coatings doped with sulfate, nitrate, and perchlorate counter ions were employed for solid-phase microextraction (SPME) of 2-chlorophenol, 2,4-dichlorophenol, triclosan, and 2,4-dichlorophenoxyacetic acid coupled to high-performance liquid chromatography. The results demonstrated that the perchlorate doped polyaniline coating exhibited the highest extraction efficiency for 2-chlorophenol, 2,4-dichlorophenol, and triclosan at pH 5.0, indicating that the extraction capability was modified by introducing different counter ions into the coatings. As a result, the perchlorate doped polyaniline coated fiber was further used for the optimization of extraction condition s . The method provided linear dynamic ranges over 2 to 4 orders of magnitude. The limits of detection were 0.006 µg · L−1, 0.005 µg · L−1, and 0.040 µg · L−1 for 2-chlorophenol, 2,4-dichlorophenol, and triclosan, respectively. The precision expressed as the relative standard deviation ranged from 2.20% to 5.04% for spiked water at 10 µg · L −1 (n = 5) and the fiber to fiber reproducibility was between 3.27% and 5.91% (n = 5). The method was successfully applied to the determination of chlorophenolics in real water samples. The recoveries of chlorophenolics in spiked water at 5.0 µg · L−1 were between 99.60% and 108.7% with relative standard deviations between 3.24% and 5.47%.
- 8 August 2014
- Published by Taylor & Francis in Analytical Letters
- Vol. 47 (15) , 2508-2521
Evaluation of the Counter Ions in Doped Porous Polyaniline Coatings on Stainless Steel Wires for Solid Phase Microextraction of Chlorophenolics in Water Combined with High-Performance Liquid Chromatography
Porous polyaniline coatings doped with different counter ions were electrodeposited on the surface of stainless steel wires using controlled potentiostatic coulometry. Prior to electropolymerization, the stainless steel wires were chemically etched to improve subsequent immobilization of the polyaniline coatings on the substrate and to increase the effective surface area. Porous polyaniline coatings doped with sulfate, nitrate, and perchlorate counter ions were employed for solid-phase microextraction (SPME) of 2-chlorophenol, 2,4-dichlorophenol, triclosan, and 2,4-dichlorophenoxyacetic acid coupled to high-performance liquid chromatography. The results demonstrated that the perchlorate doped polyaniline coating exhibited the highest extraction efficiency for 2-chlorophenol, 2,4-dichlorophenol, and triclosan at pH 5.0, indicating that the extraction capability was modified by introducing different counter ions into the coatings. As a result, the perchlorate doped polyaniline coated fiber was further used for the optimization of extraction condition s . The method provided linear dynamic ranges over 2 to 4 orders of magnitude. The limits of detection were 0.006 µg · L−1, 0.005 µg · L−1, and 0.040 µg · L−1 for 2-chlorophenol, 2,4-dichlorophenol, and triclosan, respectively. The precision expressed as the relative standard deviation ranged from 2.20% to 5.04% for spiked water at 10 µg · L −1 (n = 5) and the fiber to fiber reproducibility was between 3.27% and 5.91% (n = 5). The method was successfully applied to the determination of chlorophenolics in real water samples. The recoveries of chlorophenolics in spiked water at 5.0 µg · L−1 were between 99.60% and 108.7% with relative standard deviations between 3.24% and 5.47%.
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (20) , 6827-6832
Concentration and Determination of Ultraviolet Filters in Environmental Water Samples with Ionic Liquid-Dispersive Liquid-Liquid Microextraction Followed by High Performance Liquid Chromatography
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (20) , 6827-6832
Concentration and Determination of Ultraviolet Filters in Environmental Water Samples with Ionic Liquid-Dispersive Liquid-Liquid Microextraction Followed by High Performance Liquid Chromatography
- 5 December 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (4) , 1121-1127
Dispersive liquid–liquid microextraction followed by high performance liquid chromatography for determination of phthalic esters in environmental water samples
A new method was developed for the simultaneous determination of six phthalic acid esters (PAEs) in different environmental water samples using salt-assisted dispersive liquid–liquid microextraction with carbon tetrachloride as an extraction solvent and acetonitrile as a dispersive solvent coupled with high performance liquid chromatography with UV detection. The influence of the added NaCl on the enrichment factor (EF) in DLLME was investigated. The salting-out effect causes the hydrophobicity of organic analytes to be increased and high EFs to be more pronounced than those in salt-free water. Greater EF, wider linearity, better recovery, smaller relative standard deviation (RSD) and lower limit of detection were obtained at higher concentration of NaCl. Under optimized extraction conditions, good linearity was observed for all analytes in a range of 1.00–100 μg L−1 with the correlation coefficient (r2) ≥0.9992. The limits of detection based on the signal to noise ratio of 3 were 0.01–0.03 μg L−1. The recoveries of PAEs were 97.5–105.5% for spiked water with 20 μg L−1 of PAEs. The repeatability of the proposed method expressed as RSDs ranged from 3.13 to 5.32% (n = 3). EFs are in the range of 78 to 262 fold. The method was applied to the determination of PAEs in water samples from local river, rain and urban wastewater treatment plants with the standard addition, the recoveries of PAEs were 86.2–105.0%, 93.8–107.0% and 92.4–106.3%, and the RSDs were below 6.79%. The current procedure afforded a convenient, inexpensive and reliable sample preparation with high extraction efficiency for trace PAEs in environmental water samples.
- 5 December 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (4) , 1121-1127
Dispersive liquid–liquid microextraction followed by high performance liquid chromatography for determination of phthalic esters in environmental water samples
A new method was developed for the simultaneous determination of six phthalic acid esters (PAEs) in different environmental water samples using salt-assisted dispersive liquid–liquid microextraction with carbon tetrachloride as an extraction solvent and acetonitrile as a dispersive solvent coupled with high performance liquid chromatography with UV detection. The influence of the added NaCl on the enrichment factor (EF) in DLLME was investigated. The salting-out effect causes the hydrophobicity of organic analytes to be increased and high EFs to be more pronounced than those in salt-free water. Greater EF, wider linearity, better recovery, smaller relative standard deviation (RSD) and lower limit of detection were obtained at higher concentration of NaCl. Under optimized extraction conditions, good linearity was observed for all analytes in a range of 1.00–100 μg L−1 with the correlation coefficient (r2) ≥0.9992. The limits of detection based on the signal to noise ratio of 3 were 0.01–0.03 μg L−1. The recoveries of PAEs were 97.5–105.5% for spiked water with 20 μg L−1 of PAEs. The repeatability of the proposed method expressed as RSDs ranged from 3.13 to 5.32% (n = 3). EFs are in the range of 78 to 262 fold. The method was applied to the determination of PAEs in water samples from local river, rain and urban wastewater treatment plants with the standard addition, the recoveries of PAEs were 86.2–105.0%, 93.8–107.0% and 92.4–106.3%, and the RSDs were below 6.79%. The current procedure afforded a convenient, inexpensive and reliable sample preparation with high extraction efficiency for trace PAEs in environmental water samples.
- 11 July 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (16) , 4213-4219
Ultrasound-assisted liquid–liquid microextraction based on an ionic liquid for preconcentration and determination of UV filters in environmental water samples
In the present study, a dispersive liquid–liquid microextraction with ionic liquids (ILs) as extraction solvents was developed for the preconcentration and determination of four ultraviolet (UV) filters from different environmental water samples. Ultrasound-assisted dispersion of the ILs in the water phase was employed. The UV filters were easily concentrated into the ionic liquid phase. This technique combined the process of extraction and concentration of the analytes into one step and avoided the use of more toxic halogenated solvents. Affecting factors including the type and volume of the ILs and disperser solvents, ultrasonic time, centrifugation time, ionic strength and pH of aqueous samples were optimized. The extracts were directly analyzed by high-performance liquid chromatography coupled with a diode array detector. Under the optimized conditions, the current method provided good repeatability (RSDs < 7.6%, n = 5) and high enrichment factors in the range of 492–834. The limits of detection (LOD) for the UV filters were in the range of 0.06–0.16 ng mL−1. The linearities were between 0.2 and 500 ng mL−1 for 2-hydroxy-4-methoxybenzophenone, 0.5 and 500 ng mL−1 for 2-ethylhexyl 4-(N,N-dimethylamino) benzoate, 0.4 and 500 ng mL−1 for 2-ethylhexyl-4-methoxycinnamate, and 0.5 and 500 ng mL−1 for 2-ethylhexyl salicylate, respectively. The current procedure was successfully applied to simultaneous analyses of four UV filters in environmental water samples. For all analyzed samples, the established method has allowed fast and reliable preconcentration and determination of these UV filters with simple sample pre-treatment requirements.
- 11 July 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (16) , 4213-4219
Ultrasound-assisted liquid–liquid microextraction based on an ionic liquid for preconcentration and determination of UV filters in environmental water samples
In the present study, a dispersive liquid–liquid microextraction with ionic liquids (ILs) as extraction solvents was developed for the preconcentration and determination of four ultraviolet (UV) filters from different environmental water samples. Ultrasound-assisted dispersion of the ILs in the water phase was employed. The UV filters were easily concentrated into the ionic liquid phase. This technique combined the process of extraction and concentration of the analytes into one step and avoided the use of more toxic halogenated solvents. Affecting factors including the type and volume of the ILs and disperser solvents, ultrasonic time, centrifugation time, ionic strength and pH of aqueous samples were optimized. The extracts were directly analyzed by high-performance liquid chromatography coupled with a diode array detector. Under the optimized conditions, the current method provided good repeatability (RSDs < 7.6%, n = 5) and high enrichment factors in the range of 492–834. The limits of detection (LOD) for the UV filters were in the range of 0.06–0.16 ng mL−1. The linearities were between 0.2 and 500 ng mL−1 for 2-hydroxy-4-methoxybenzophenone, 0.5 and 500 ng mL−1 for 2-ethylhexyl 4-(N,N-dimethylamino) benzoate, 0.4 and 500 ng mL−1 for 2-ethylhexyl-4-methoxycinnamate, and 0.5 and 500 ng mL−1 for 2-ethylhexyl salicylate, respectively. The current procedure was successfully applied to simultaneous analyses of four UV filters in environmental water samples. For all analyzed samples, the established method has allowed fast and reliable preconcentration and determination of these UV filters with simple sample pre-treatment requirements.
- 5 April 2013
- Published by Taylor & Francis in Analytical Letters
- Vol. 46 (14) , 2290-2301
A Novel Fiber with Phenyl-Functionalized MSU (Michigan State University) Coating for Solid-Phase Microextraction Combined with High Performance Liquid Chromatography for Preconcentration and Determination of Trace Polychlorinated Biphenyls in Environmental Water Samples
A novel and robust phenyl-functionalized MSU-1 (Ph-MSU) coated fiber for solid-phase microextraction (SPME) coupled to high performance liquid chromatography (HPLC) was developed for the preconcentration and the determination of 2,4,4′-trichlorobiphenyl (PCB 28), 2,4′,5-trichlorobiphenyl (PCB 31), 2,2′,5,5′-tetrachlorobiphenyl (PCB 52), 2,2′,4,5,5′-pentachlorobiphenyl (PCB 101), 2,3′,4,4′,5-pentachlorobiphenyl (PCB 118), 2,2′,3,4,4′,5′-hexachlorobiphenyl (PCB 138), 2,2′,4,4′,5,5′-hexachlorobiphenyl (PCB 153), and 2,2′,3,4,4′,5,5′-heptachlorobiphenyl (PCB 180) in environmental water samples. Experimental conditions affecting SPME were examined in detail. The Ph-MSU coating provided large porosity and short-range mesostructures necessary for high extraction capacity and rapid mass transfer of PCBs. The Ph-MSU coated fiber exhibited selectivity for PCB 28, PCB 31, PCB 118, and PCB 138 in a limited extraction time. Good linearity for all PCBs was obtained with correlation coefficients from 0.9987 to 0.9994. The recoveries were within 94.3% to 103% for the spiked water with 300 ng · L−1 per PCB. The relative standard deviations (RSDs) ranged from 3.10% to 6.23% and the limits of detection (LODs) were between 8.73 ng · L−1 and 13.8 ng · L−1. The proposed method was applied for the determination of PCBs in real river water and rainwater samples. The median recoveries ranged from 85.6% to 118% with RSDs between 4.23% and 8.78%. The experimental results demonstrated that the Ph-MSU fiber coating could be reused for over 250 times without loss of the extraction efficiency. These results clearly indicate that the Ph-MSU coated fiber was rapid, sensitive, and suitable for the preconcentration and determination of trace PCBs in environmental water samples.
- 5 April 2013
- Published by Taylor & Francis in Analytical Letters
- Vol. 46 (14) , 2290-2301
A Novel Fiber with Phenyl-Functionalized MSU (Michigan State University) Coating for Solid-Phase Microextraction Combined with High Performance Liquid Chromatography for Preconcentration and Determination of Trace Polychlorinated Biphenyls in Environmental Water Samples
A novel and robust phenyl-functionalized MSU-1 (Ph-MSU) coated fiber for solid-phase microextraction (SPME) coupled to high performance liquid chromatography (HPLC) was developed for the preconcentration and the determination of 2,4,4′-trichlorobiphenyl (PCB 28), 2,4′,5-trichlorobiphenyl (PCB 31), 2,2′,5,5′-tetrachlorobiphenyl (PCB 52), 2,2′,4,5,5′-pentachlorobiphenyl (PCB 101), 2,3′,4,4′,5-pentachlorobiphenyl (PCB 118), 2,2′,3,4,4′,5′-hexachlorobiphenyl (PCB 138), 2,2′,4,4′,5,5′-hexachlorobiphenyl (PCB 153), and 2,2′,3,4,4′,5,5′-heptachlorobiphenyl (PCB 180) in environmental water samples. Experimental conditions affecting SPME were examined in detail. The Ph-MSU coating provided large porosity and short-range mesostructures necessary for high extraction capacity and rapid mass transfer of PCBs. The Ph-MSU coated fiber exhibited selectivity for PCB 28, PCB 31, PCB 118, and PCB 138 in a limited extraction time. Good linearity for all PCBs was obtained with correlation coefficients from 0.9987 to 0.9994. The recoveries were within 94.3% to 103% for the spiked water with 300 ng · L−1 per PCB. The relative standard deviations (RSDs) ranged from 3.10% to 6.23% and the limits of detection (LODs) were between 8.73 ng · L−1 and 13.8 ng · L−1. The proposed method was applied for the determination of PCBs in real river water and rainwater samples. The median recoveries ranged from 85.6% to 118% with RSDs between 4.23% and 8.78%. The experimental results demonstrated that the Ph-MSU fiber coating could be reused for over 250 times without loss of the extraction efficiency. These results clearly indicate that the Ph-MSU coated fiber was rapid, sensitive, and suitable for the preconcentration and determination of trace PCBs in environmental water samples.
- 1 April 2008
- Published by Elsevier in Applied Surface Science
- Vol. 254 (13) , 3753-3757
Direct synthesis and characterization of phenyl-functionalized SBA-15
- 1 April 2008
- Published by Elsevier in Applied Surface Science
- Vol. 254 (13) , 3753-3757
Direct synthesis and characterization of phenyl-functionalized SBA-15