Telli Faez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Telli Faez has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Nico de Jong
The Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands, Interuniversity Cardiology Institute Netherlands, Utrecht, The Netherlands
4 shared publications- Michel Versluis
Physics of Fluids group, TechMed Centre, University of Twente, Enschede, The Netherlands
3 shared publications - Klazina Kooiman
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
2 shared publications Marcia Emmer
The Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands, Interuniversity Cardiology Institute Netherlands, Utrecht, The Netherlands
2 shared publicationsAntonius F.W. van der Steen
The Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands, Interuniversity Cardiology Institute Netherlands, Utrecht, The Netherlands
1 shared publicationDavid Goertz
Imaging Research Sunnybrook Health Sciences Centre, Toronto, Canada
1 shared publication
Latest Publications
- 28 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 60 (1) , 7-20
20 years of ultrasound contrast agent modeling
The merits of ultrasound contrast agents (UCAs) were already known in the 1960s. It was, however, not until the 1990s that UCAs were clinically approved and marketed. In these years, it was realized that the UCAs are not just efficient ultrasound scatterers, but that their main constituent, the coated gas microbubble, acts as a nonlinear resonator and, as such, is capable of generating harmonic energy. Subharmonic, ultraharmonic, and higher harmonic frequencies of the transmitted ultrasound frequency have been reported. This opened up new prospects for their use and several detection strategies have been developed to exploit this harmonic energy to discriminate the contrast bubbles from surrounding tissue. This insight created a need for tools to study coated bubble behavior in an ultrasound field and the first models were developed. Since then, 20 years have elapsed, in which a broad range of UCAs and UCA models have been developed. Although the models have helped in understanding the responses of coated bubbles, the influence of the coating has not been fully elucidated to date and UCA models are still being improved. The aim of this review paper is to offer an overview in these developments and indicate future directions for research.
- 28 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 60 (1) , 7-20
20 years of ultrasound contrast agent modeling
The merits of ultrasound contrast agents (UCAs) were already known in the 1960s. It was, however, not until the 1990s that UCAs were clinically approved and marketed. In these years, it was realized that the UCAs are not just efficient ultrasound scatterers, but that their main constituent, the coated gas microbubble, acts as a nonlinear resonator and, as such, is capable of generating harmonic energy. Subharmonic, ultraharmonic, and higher harmonic frequencies of the transmitted ultrasound frequency have been reported. This opened up new prospects for their use and several detection strategies have been developed to exploit this harmonic energy to discriminate the contrast bubbles from surrounding tissue. This insight created a need for tools to study coated bubble behavior in an ultrasound field and the first models were developed. Since then, 20 years have elapsed, in which a broad range of UCAs and UCA models have been developed. Although the models have helped in understanding the responses of coated bubbles, the influence of the coating has not been fully elucidated to date and UCA models are still being improved. The aim of this review paper is to offer an overview in these developments and indicate future directions for research.
- 4 July 2012
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 38 (9) , 1608-1617
In Vivo Characterization of Ultrasound Contrast Agents: Microbubble Spectroscopy in a Chicken Embryo
- 4 July 2012
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 38 (9) , 1608-1617
In Vivo Characterization of Ultrasound Contrast Agents: Microbubble Spectroscopy in a Chicken Embryo
- 20 September 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (19) , 6459-6473
Dynamic manipulation of the subharmonic scattering of phospholipid-coated microbubbles
In this paper, the influence of a dynamic variation in the ambient pressure on the subharmonic response of phospholipid-coated microbubbles was investigated. The ambient pressure in water was modulated by a 2.5 kHz acoustic wave with a peak amplitude of 15 kPa. We investigated the fundamental and subharmonic emissions at two driving frequencies: 5 and 10 MHz. The modulation of the bubble radius induced by the dynamic variation in the liquid ambient pressure subsequently causes modulations of the scattered acoustic pressure at the fundamental and subharmonic frequencies (half the fundamental frequency). As a first result, we measured that the variation in the ambient pressure of 15 kPa can modulate the subharmonic amplitude up to 10 dB as compared to the static atmospheric pressure condition. As a second result, we noticed that the relative subharmonic amplitude modulation as a function of the LF acoustic pressure was symmetrical for the 5 MHz driving frequency but asymmetric for 10 MHz. In the latter case, the subharmonic amplitude was more enhanced for an ambient overpressure than reduced for an ambient depression of the same amplitude likely due to the buckling of the lipid shell. However, the fundamental amplitude was symmetrically modulated during bubble compression and expansion. Moreover, subharmonic and fundamental amplitude modulations were found to be either in phase or out of phase with the low-frequency acoustic pressure. Numerical simulations showed that this behavior can be obtained depending on the bubbles' diameter. The highest subharmonic amplitude was measured when microbubbles were insonified at 10 MHz. This fact together with the asymmetry observed in the subharmonic modulation suggests that smaller bubbles with a buckling shell are excited at 10 MHz compared to 5 MHz. These results present new potentials for in vitro characterization of contrast agent microbubbles and possibly a new imaging modality.
- 20 September 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (19) , 6459-6473
Dynamic manipulation of the subharmonic scattering of phospholipid-coated microbubbles
In this paper, the influence of a dynamic variation in the ambient pressure on the subharmonic response of phospholipid-coated microbubbles was investigated. The ambient pressure in water was modulated by a 2.5 kHz acoustic wave with a peak amplitude of 15 kPa. We investigated the fundamental and subharmonic emissions at two driving frequencies: 5 and 10 MHz. The modulation of the bubble radius induced by the dynamic variation in the liquid ambient pressure subsequently causes modulations of the scattered acoustic pressure at the fundamental and subharmonic frequencies (half the fundamental frequency). As a first result, we measured that the variation in the ambient pressure of 15 kPa can modulate the subharmonic amplitude up to 10 dB as compared to the static atmospheric pressure condition. As a second result, we noticed that the relative subharmonic amplitude modulation as a function of the LF acoustic pressure was symmetrical for the 5 MHz driving frequency but asymmetric for 10 MHz. In the latter case, the subharmonic amplitude was more enhanced for an ambient overpressure than reduced for an ambient depression of the same amplitude likely due to the buckling of the lipid shell. However, the fundamental amplitude was symmetrically modulated during bubble compression and expansion. Moreover, subharmonic and fundamental amplitude modulations were found to be either in phase or out of phase with the low-frequency acoustic pressure. Numerical simulations showed that this behavior can be obtained depending on the bubbles' diameter. The highest subharmonic amplitude was measured when microbubbles were insonified at 10 MHz. This fact together with the asymmetry observed in the subharmonic modulation suggests that smaller bubbles with a buckling shell are excited at 10 MHz compared to 5 MHz. These results present new potentials for in vitro characterization of contrast agent microbubbles and possibly a new imaging modality.
- 1 June 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (6) , 958-970
Characterizing the Subharmonic Response of Phospholipid-Coated Microbubbles for Carotid Imaging
- 1 June 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (6) , 958-970
Characterizing the Subharmonic Response of Phospholipid-Coated Microbubbles for Carotid Imaging
- 1 February 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (2) , 338-342
Characterization of Definity™ Ultrasound Contrast Agent at Frequency Range of 5–15 MHz
- 1 February 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (2) , 338-342
Characterization of Definity™ Ultrasound Contrast Agent at Frequency Range of 5–15 MHz