DSDi Shi

Di Shi

*This is an algorithmically generated author record based on publicly available information.

Di Shi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Blockchain-Enabled Demand Management and Control Framework Driven by Deep Reinforcement Learning

    by Rui Ma, Zhehan Yi, Yingmeng Xiang, Di Shi, Chunlei Xu, Haiwei Wu

    The rapid development of Internet-of-Things (IoT) in smart grid has enabled millions of grid-connected Distributed Controllable Resources (DCR, e.g., electric vehicles, controllable loads) to provide service to the grid, such as frequency regulation and demand response. The integration of these DCRs may become a large virtual power plant (VPP) network with various characteristics. This poses great challenges from both control and management perspectives, e.g., computation/communication burden, optimization complexity, scalability limitation, prosumer privacy, etc. This paper proposes an effective autonomous incentive-based DCR control and management framework to integrate a large amount of DCRs to provide grid services, which simultaneously provides accurate active power adjustment to the grid, optimizes DCR allocations, and maximizes the profits for all prosumers and system operators. A model-free Deep Deterministic Policy Gradient (DDPG) based method is designed to find the optimal incentives in a continuous action space to encourage prosumers to adjust their power consumption. The method is implemented in a consortium open-source blockchain platform, Hyperledger Fabric, which facilitates controls and transaction management. To demonstrate the effectiveness of the framework, extensive experimental studies are conducted using real-world data.


  • Open Access

    Transmission line parameter identification using PMU measurements

    by Di Shi, Daniel J. Tylavsky, Kristian M. Koellner, Naim Logic, David E. Wheeler

    Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMUs). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully-transposed TL when measurement noise is absent; however these methods may generate erroneous parameters when the TLs are not fully transposed or when measurement noise is present. PMU field-measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short transmission lines. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TLs that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short or long lines that are fully transposed or untransposed and have balanced or unbalance loads. Besides the positive or negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated.

  • Transmission line parameter identification using PMU measurements

    by Di Shi, Daniel J. Tylavsky, Kristian M. Koellner, Naim Logic, David E. Wheeler

    Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMUs). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully transposed TL when measurement noise is absent; however, these methods may generate erroneous parameters when the TLs are not fully transposed or when measurement noise is present. PMU field‐measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short TLs. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TLs that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short/long lines that are fully transposed or untransposed and have balanced/unbalance loads. Besides the positive/negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated. Copyright © 2010 John Wiley & Sons, Ltd.