Patrick W. Stroman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Patrick W. Stroman has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chase R. Figley
Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
4 shared publications - Jennifer Kornelsen
Department of Radiology, University of Manitoba, Canada
3 shared publications - Jane M. Lawrence-Dewar
Thunder Bay Regional Health Research Institute, Thunder Bay, Canada
2 shared publications - Massimo Filippi
Neurology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
2 shared publications A.S. Lee
Department of Anatomy and Cell Biology, Queen's University, Kingston, Ontario, Canada
1 shared publication- Brian C. Coe
Centre for Neuroscience Studies Queen's University Kingston Ontario Canada
1 shared publication
Latest Publications
- 24 September 2016
- Published by Springer Nature
- p. 871-892
Functional MRI of the Spinal Cord
- 1 January 2011
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 29 (1) , 9-18
Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation
- 1 January 2011
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 29 (1) , 9-18
Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation
- 29 March 2010
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 28 (8) , 1234-1243
In contrast to BOLD: signal enhancement by extravascular water protons as an alternative mechanism of endogenous fMRI signal change
- 29 March 2010
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 28 (8) , 1234-1243
In contrast to BOLD: signal enhancement by extravascular water protons as an alternative mechanism of endogenous fMRI signal change
- Open Access
- 1 July 2008
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 26 (6) , 809-814
Spatial normalization, bulk motion correction and coregistration for functional magnetic resonance imaging of the human cervical spinal cord and brainstem
- 1 July 2008
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 26 (6) , 809-814
Open AccessSpatial normalization, bulk motion correction and coregistration for functional magnetic resonance imaging of the human cervical spinal cord and brainstem
- Open Access
- 4 June 2008
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 29 (8) , 1450-1454
Attenuation of Lower-Thoracic, Lumbar, and Sacral Spinal Cord Motion: Implications for Imaging Human Spinal Cord Structure and Function
BACKGROUND AND PURPOSE: Recent literature indicates that cervical and upper-thoracic spinal cord motion adversely affect both structural and functional MR imaging (fMRI; particularly diffusion tensor imaging [DTI] and spinal fMRI), ultimately reducing the reliability of these methods for both research and clinical applications. In the present study, we investigated motion of the lower-thoracic, lumbar, and sacral cord segments to evaluate the incidence of similar motion-related confounds in these regions.
- 4 June 2008
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 29 (8) , 1450-1454
Open AccessAttenuation of Lower-Thoracic, Lumbar, and Sacral Spinal Cord Motion: Implications for Imaging Human Spinal Cord Structure and Function
BACKGROUND AND PURPOSE: Recent literature indicates that cervical and upper-thoracic spinal cord motion adversely affect both structural and functional MR imaging (fMRI; particularly diffusion tensor imaging [DTI] and spinal fMRI), ultimately reducing the reliability of these methods for both research and clinical applications. In the present study, we investigated motion of the lower-thoracic, lumbar, and sacral cord segments to evaluate the incidence of similar motion-related confounds in these regions.
- 27 March 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (4) , 700-706
Magnetic resonance imaging of neuronal and glial swelling as an indicator of function in cerebral tissue slices
Here we demonstrate a new basis of signal change in magnetic resonance imaging (MRI) related to neuronal function, independent of blood oxygenation or flow. Time series MRI data acquired from living, superfused brain slices of adult rats revealed that the signal intensity reversibly increased with depolarization evoked by briefly elevating extracellular K+. This was presumably a consequence of increased tissue water in the intracellular compartment. Reversible increases in light transmittance (LT) demonstrating a similar time course in response to K+elevation supported cellular swelling as generating the MRI signal intensity changes. This was confirmed by reversibly swelling cells in the slice under hypoosmotic challenge, which increased both MRI and LT signals with an identical time course. Conversely, shrinking cells under hyperosmotic challenge reversibly decreased the MRI and LT signals. We propose that specific MRI of neuronal function (fMRI) signals detected under identical parameters during predominantly proton‐density‐weighted fMRI of the spinal cord can now be explained by neuronal and glial swelling in activated central nervous system (CNS) regions. These observations demonstrate the biophysical basis of the fMRI contrast mechanism that has been termed “signal enhancement by extravascular water protons,” or SEEP. Magn Reson Med 59:700–706, 2008.
- 27 March 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (4) , 700-706
Magnetic resonance imaging of neuronal and glial swelling as an indicator of function in cerebral tissue slices
Here we demonstrate a new basis of signal change in magnetic resonance imaging (MRI) related to neuronal function, independent of blood oxygenation or flow. Time series MRI data acquired from living, superfused brain slices of adult rats revealed that the signal intensity reversibly increased with depolarization evoked by briefly elevating extracellular K+. This was presumably a consequence of increased tissue water in the intracellular compartment. Reversible increases in light transmittance (LT) demonstrating a similar time course in response to K+elevation supported cellular swelling as generating the MRI signal intensity changes. This was confirmed by reversibly swelling cells in the slice under hypoosmotic challenge, which increased both MRI and LT signals with an identical time course. Conversely, shrinking cells under hyperosmotic challenge reversibly decreased the MRI and LT signals. We propose that specific MRI of neuronal function (fMRI) signals detected under identical parameters during predominantly proton‐density‐weighted fMRI of the spinal cord can now be explained by neuronal and glial swelling in activated central nervous system (CNS) regions. These observations demonstrate the biophysical basis of the fMRI contrast mechanism that has been termed “signal enhancement by extravascular water protons,” or SEEP. Magn Reson Med 59:700–706, 2008.
- 22 June 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (2) , 452-456
Discrimination of errors from neuronal activity in functional MRI of the human spinal cord by means of general linear model analysis
Functional MRI (fMRI) of the spinal cord has been demonstrated to provide reliable and sensitive maps of neuronal activity, particularly when combined across several experiments. Individual experiments reveal neuronal activity as well as errors. The dominant source of errors is hypothesized to be physiological motion, including cardiac and respiratory motion, flow of blood and cerebrospinal fluid (CSF), and motion of the spinal cord within the spinal canal. All of the hypothesized sources of error are therefore related to cardiac and respiratory motion, which can be recorded during an fMRI experiment. Analyses were carried out with a general linear model (GLM) with peripheral pulse and respiration recordings used as models of errors. The results demonstrate that the sensitivity of spinal fMRI is improved and errors are reduced when peripheral pulse traces are used in the GLM, but no improvement was detected with the inclusion of respiratory traces. Magn Reson Med, 2006.
- 22 June 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (2) , 452-456
Discrimination of errors from neuronal activity in functional MRI of the human spinal cord by means of general linear model analysis
Functional MRI (fMRI) of the spinal cord has been demonstrated to provide reliable and sensitive maps of neuronal activity, particularly when combined across several experiments. Individual experiments reveal neuronal activity as well as errors. The dominant source of errors is hypothesized to be physiological motion, including cardiac and respiratory motion, flow of blood and cerebrospinal fluid (CSF), and motion of the spinal cord within the spinal canal. All of the hypothesized sources of error are therefore related to cardiac and respiratory motion, which can be recorded during an fMRI experiment. Analyses were carried out with a general linear model (GLM) with peripheral pulse and respiration recordings used as models of errors. The results demonstrate that the sensitivity of spinal fMRI is improved and errors are reduced when peripheral pulse traces are used in the GLM, but no improvement was detected with the inclusion of respiratory traces. Magn Reson Med, 2006.
- 31 October 2005
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 23 (8) , 843-850
Functional magnetic resonance imaging based on SEEP contrast: response function and anatomical specificity
- 31 October 2005
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 23 (8) , 843-850
Functional magnetic resonance imaging based on SEEP contrast: response function and anatomical specificity