Abdulrahman Alsanosi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdulrahman Alsanosi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Yassin Abdelsamad
Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
3 shared publications - Fida Almuhawas
King Abdullah Ear Specialist Center (KAESC), King Saud Medical City, King Saud University, Riyadh 11411, Saudi Arabia
2 shared publications - Afrah Alshalan
Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Jouf University, Skaka, Aljouf, Saudi Arabia
1 shared publication - Asma Alahmadi
Maternity and Children Hospital, Makkah, Saudi Arabia
1 shared publication - Atheer A. Alsufyani
Department of Otolaryngology, Head and Neck Surgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia
1 shared publication - Dalal Alrushaydan
Cochlear Arabia Regional Headquarters, Riyadh 12361, Saudi Arabia
1 shared publication
Latest Publications
- 23 April 2026
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (8) , 1-11
Trans-impedance matrix heatmap patterns in cochlear implant patients with different cochlear pathologies: meningitis, otosclerosis, and temporal bone fractures
Purpose Transimpedance matrix (TIM) imaging is an electrical field–based modality that visualizes intracochlear current spread and may detect electrode malposition and subtle cochlear pathology beyond radiological resolution. This study aimed to evaluate etiology-specific TIM heatmap patterns in adult cochlear implant recipients and to assess the utility of TIM as an adjunct to conventional imaging. Methods This observational retrospective case series included 11 adult cochlear implant recipients (15 implanted ears) with defined etiologies: head trauma/temporal bone fracture (5 ears), post-meningitis deafness (5 ears), and cochlear ossification or otosclerosis (5 ears). Preoperative CT and/or MRI confirmed pathology, and postoperative X-ray verified electrode position. TIM measurements were obtained using Cochlear® CustomSound EP software. A normal TIM pattern was defined as a continuous diagonal gradient from bottom-left to top-right. Deviations from this pattern were analyzed and correlated with etiology and radiological findings. Results Distinct etiology-related TIM deviations were identified. Trauma cases showed off-diagonal irregularities and signal dissociation suggestive of fractures or over-insertion, including one abnormal TIM with normal imaging. Post-meningitis ears commonly demonstrated off-diagonal signal loss or apical attenuation without radiological correlations. Severe ossification with under-insertion produced an Ocean Pattern of low potentials, whereas one otosclerosis case preserved a normal diagonal pattern configuration. Conclusion TIM imaging is highly sensitive to changes in tissue conductivity and electrode–tissue interface integrity, enabling detection of early fibrosis or ossification not visible on standard imaging. TIM may serve as a useful adjunct in postoperative cochlear implant evaluation. Further prospective validation is required.
- 23 April 2026
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (8) , 1-11
Trans-impedance matrix heatmap patterns in cochlear implant patients with different cochlear pathologies: meningitis, otosclerosis, and temporal bone fractures
Purpose Transimpedance matrix (TIM) imaging is an electrical field–based modality that visualizes intracochlear current spread and may detect electrode malposition and subtle cochlear pathology beyond radiological resolution. This study aimed to evaluate etiology-specific TIM heatmap patterns in adult cochlear implant recipients and to assess the utility of TIM as an adjunct to conventional imaging. Methods This observational retrospective case series included 11 adult cochlear implant recipients (15 implanted ears) with defined etiologies: head trauma/temporal bone fracture (5 ears), post-meningitis deafness (5 ears), and cochlear ossification or otosclerosis (5 ears). Preoperative CT and/or MRI confirmed pathology, and postoperative X-ray verified electrode position. TIM measurements were obtained using Cochlear® CustomSound EP software. A normal TIM pattern was defined as a continuous diagonal gradient from bottom-left to top-right. Deviations from this pattern were analyzed and correlated with etiology and radiological findings. Results Distinct etiology-related TIM deviations were identified. Trauma cases showed off-diagonal irregularities and signal dissociation suggestive of fractures or over-insertion, including one abnormal TIM with normal imaging. Post-meningitis ears commonly demonstrated off-diagonal signal loss or apical attenuation without radiological correlations. Severe ossification with under-insertion produced an Ocean Pattern of low potentials, whereas one otosclerosis case preserved a normal diagonal pattern configuration. Conclusion TIM imaging is highly sensitive to changes in tissue conductivity and electrode–tissue interface integrity, enabling detection of early fibrosis or ossification not visible on standard imaging. TIM may serve as a useful adjunct in postoperative cochlear implant evaluation. Further prospective validation is required.
- Open Access
- 12 August 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (16) , 4716
Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials
Objective: The electrically evoked compound action potential (ECAP) is an objective measure to indirectly assess spiral ganglion neurons. The ECAP provides inputs about the prognoses of cochlear implant (CI) recipients. Several factors such as cochlear morphology can affect ECAP measurements. This study aims to investigate the variation effect of cochlear parameters on intraoperative ECAP thresholds. Methods: This is a retrospective study on patients who underwent CI surgery with normal inner ear morphology at our center between 2017 and 2023. Cochlear anatomical parameters, including diameter (A value), width (B value), and height (H value), as well as cochlear duct length (CDL), were measured pre-operatively using OTOPLAN software (Version 3.0). Cochlear implant intraoperative objective measures were also collected. The correlation between the cochlear parameters and intraoperative objective measures was studied. Results: A total of 45 patients underwent cochlear implantation. The mean age was 2.4 ± 0.9 years. The mean CDL and cochlear coverage values were 33.2 ± 2.0 mm and 76.0 ± 5.7%, respectively. The ECAP threshold increased toward basal electrodes, with ECAP values as follows: apical 13.1 ± 3.8; middle 14.3 ± 3.7; and basal 15.6 ± 4.8. Additionally, the A, B, and H values showed a positive correlation with ECAP thresholds in different cochlear regions. The B value showed a significant moderate correlation with ECAP thresholds in the middle and basal electrodes but not in the apical electrodes. Conclusions: Cochlear anatomical parameters correlate with intraoperative ECAP thresholds. The B value showed a significant association with ECAP thresholds in the middle and basal electrodes. These findings could delineate the impact of the B value in CI and optimize electrode selection. Further research is required to study this correlation and its impact on postoperative outcomes.
- 12 August 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (16) , 4716
Open AccessInfluence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials
Objective: The electrically evoked compound action potential (ECAP) is an objective measure to indirectly assess spiral ganglion neurons. The ECAP provides inputs about the prognoses of cochlear implant (CI) recipients. Several factors such as cochlear morphology can affect ECAP measurements. This study aims to investigate the variation effect of cochlear parameters on intraoperative ECAP thresholds. Methods: This is a retrospective study on patients who underwent CI surgery with normal inner ear morphology at our center between 2017 and 2023. Cochlear anatomical parameters, including diameter (A value), width (B value), and height (H value), as well as cochlear duct length (CDL), were measured pre-operatively using OTOPLAN software (Version 3.0). Cochlear implant intraoperative objective measures were also collected. The correlation between the cochlear parameters and intraoperative objective measures was studied. Results: A total of 45 patients underwent cochlear implantation. The mean age was 2.4 ± 0.9 years. The mean CDL and cochlear coverage values were 33.2 ± 2.0 mm and 76.0 ± 5.7%, respectively. The ECAP threshold increased toward basal electrodes, with ECAP values as follows: apical 13.1 ± 3.8; middle 14.3 ± 3.7; and basal 15.6 ± 4.8. Additionally, the A, B, and H values showed a positive correlation with ECAP thresholds in different cochlear regions. The B value showed a significant moderate correlation with ECAP thresholds in the middle and basal electrodes but not in the apical electrodes. Conclusions: Cochlear anatomical parameters correlate with intraoperative ECAP thresholds. The B value showed a significant association with ECAP thresholds in the middle and basal electrodes. These findings could delineate the impact of the B value in CI and optimize electrode selection. Further research is required to study this correlation and its impact on postoperative outcomes.
- Open Access
- 19 January 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (2) , 171
Cochlear Implantation: The Volumetric Measurement of Vestibular Aqueduct and Gusher Prediction
This study aimed to validate the role of 3D segmentation in measuring the volume of the vestibular aqueduct (VAD), and the inner ear, and to study the correlation between VAD volume and VAD linear measurements at the midpoint and operculum. The correlation with other cochlear metrics was also studied. We retrospectively recruited 21 children (42 ears) diagnosed with Mondini dysplasia (MD) plus enlarged vestibular aqueduct (EVA) from 2009 to 2021 and who underwent cochlear implantation (CI). Patients’ sociodemographic data were collected, and linear cochlear metrics were measured using Otoplan. Vestibular aqueduct width and vestibular aqueduct and inner ear volumes were measured by two independent neuro-otologists using 3D segmentation software (version 4.11.20210226) and high-resolution CT. We also conducted a regression analysis to determine the association between these variables and CT VAD and inner ear volumes. Among the 33 cochlear implanted ears, 13 ears had a gusher (39.4%). Regarding CT inner ear volume, we found that gender, age, A-value, and VAD at the operculum were statistically significant (p-Value = 0.003, p-Value < 0.04). Finally, gender (OR: 0.092; 95%CI: 0.009–0.982; p-Value = 0.048) and VAD at the midpoint (OR: 0.106; 95%CI: 0.015–0.735; p-Value = 0.023) were significant predictors of gusher risk. Patients’ gusher risk was significantly differentiated by gender and VAD width at the midpoint.
- 19 January 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (2) , 171
Open AccessCochlear Implantation: The Volumetric Measurement of Vestibular Aqueduct and Gusher Prediction
This study aimed to validate the role of 3D segmentation in measuring the volume of the vestibular aqueduct (VAD), and the inner ear, and to study the correlation between VAD volume and VAD linear measurements at the midpoint and operculum. The correlation with other cochlear metrics was also studied. We retrospectively recruited 21 children (42 ears) diagnosed with Mondini dysplasia (MD) plus enlarged vestibular aqueduct (EVA) from 2009 to 2021 and who underwent cochlear implantation (CI). Patients’ sociodemographic data were collected, and linear cochlear metrics were measured using Otoplan. Vestibular aqueduct width and vestibular aqueduct and inner ear volumes were measured by two independent neuro-otologists using 3D segmentation software (version 4.11.20210226) and high-resolution CT. We also conducted a regression analysis to determine the association between these variables and CT VAD and inner ear volumes. Among the 33 cochlear implanted ears, 13 ears had a gusher (39.4%). Regarding CT inner ear volume, we found that gender, age, A-value, and VAD at the operculum were statistically significant (p-Value = 0.003, p-Value < 0.04). Finally, gender (OR: 0.092; 95%CI: 0.009–0.982; p-Value = 0.048) and VAD at the midpoint (OR: 0.106; 95%CI: 0.015–0.735; p-Value = 0.023) were significant predictors of gusher risk. Patients’ gusher risk was significantly differentiated by gender and VAD width at the midpoint.
- 7 September 2022
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 162, 111302
Brain MRI findings of prelingually deaf children and cochlear implant outcome: Preliminary results
- 7 September 2022
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 162, 111302
Brain MRI findings of prelingually deaf children and cochlear implant outcome: Preliminary results
- 1 October 2012
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 126 (12) , 1274-1275
Influenza A (H1N1): a rare cause of deafness in two children
Objective: We report deafness occurring as an extremely rare complication of influenza A caused by the H1N1 virus (‘swine flu’), in two children.Methods: Case reports and review of the literature concerning influenza A (H1N1) and acquired viral infection causing deafness.Results: Two children with normal hearing developed bilateral deafness following influenza A (H1N1). The diagnosis was confirmed using polymerase chain reaction. Both patients were treated with oseltamivir.Conclusion: Following a review of the literature, these two patients appear to be the first reported cases of bilateral deafness following influenza A (H1N1).
- 1 October 2012
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 126 (12) , 1274-1275
Influenza A (H1N1): a rare cause of deafness in two children
Objective: We report deafness occurring as an extremely rare complication of influenza A caused by the H1N1 virus (‘swine flu’), in two children.Methods: Case reports and review of the literature concerning influenza A (H1N1) and acquired viral infection causing deafness.Results: Two children with normal hearing developed bilateral deafness following influenza A (H1N1). The diagnosis was confirmed using polymerase chain reaction. Both patients were treated with oseltamivir.Conclusion: Following a review of the literature, these two patients appear to be the first reported cases of bilateral deafness following influenza A (H1N1).