Nicolae Plitea
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicolae Plitea has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Doina Pisla
CESTER, Technical University of Cluj-Napoca
20 shared publications - Calin Vaida
CESTER, Technical University of Cluj-Napoca
19 shared publications - Bogdan Gherman
CESTER, Technical University of Cluj-Napoca
12 shared publications - Giuseppe Carbone
Politecnico di Bari
6 shared publications - Paul Tucan
CESTER, Technical University of Cluj-Napoca
5 shared publications - A. Szilaghyi
Technical University of Cluj-Napoca
3 shared publications
Latest Publications
- Open Access
- 24 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 9932
A Parallel Robot with Torque Monitoring for Brachial Monoparesis Rehabilitation Tasks
Robots for rehabilitation tasks require a high degree of safety for the interaction with both the patients and for the operators. In particular, high safety is a stable and intuitive control of the moving elements of the system combined with an external system of sensors able to monitor the position of every aspect of the rehabilitation system (operator, robot, and patient) and overcome in a certain measure all the events that may occur during the robotic rehabilitation procedure. This paper presents the development of an internal torque monitoring system for ASPIRE. This is a parallel robot designed for shoulder rehabilitation, which enables the use of strategies towards developing a HRI (human–robot interaction) system for the therapy. A complete analysis regarding the components of the robotic system is carried out with the purpose of determining the dynamic behavior of the system. Next, the proposed torque monitoring system is developed with respect to the previously obtained data. Several experimental tests are performed using healthy subjects being equipped with a series of biomedical sensors with the purpose of validating the proposed torque monitoring strategy and, at the same time, to satisfy the degree of safety that is requested by the medical procedure.
- 24 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 9932
Open AccessA Parallel Robot with Torque Monitoring for Brachial Monoparesis Rehabilitation Tasks
Robots for rehabilitation tasks require a high degree of safety for the interaction with both the patients and for the operators. In particular, high safety is a stable and intuitive control of the moving elements of the system combined with an external system of sensors able to monitor the position of every aspect of the rehabilitation system (operator, robot, and patient) and overcome in a certain measure all the events that may occur during the robotic rehabilitation procedure. This paper presents the development of an internal torque monitoring system for ASPIRE. This is a parallel robot designed for shoulder rehabilitation, which enables the use of strategies towards developing a HRI (human–robot interaction) system for the therapy. A complete analysis regarding the components of the robotic system is carried out with the purpose of determining the dynamic behavior of the system. Next, the proposed torque monitoring system is developed with respect to the previously obtained data. Several experimental tests are performed using healthy subjects being equipped with a series of biomedical sensors with the purpose of validating the proposed torque monitoring strategy and, at the same time, to satisfy the degree of safety that is requested by the medical procedure.
- Open Access
- 22 March 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (6) , 3281
Optimization of the ASPIRE Spherical Parallel Rehabilitation Robot Based on Its Clinical Evaluation
The paper presents the design optimization of the ASPIRE spherical parallel robot for shoulder rehabilitation following clinical evaluation and clinicians’ feedback. After the development of the robotic structure and the implementation of the control system, ASPIRE was prepared for clinical evaluation. A set of clinical trials was performed on 24 patients with different neurological disorders to obtain the patient and clinician acceptance of the rehabilitation system. During the clinical trials, the behavior of the robotic system was closely monitored and analyzed in order to improve its reliability and overall efficiency. Along with its reliability and efficiency, special attention was given to the safety characteristics during the rehabilitation task.
- 22 March 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (6) , 3281
Open AccessOptimization of the ASPIRE Spherical Parallel Rehabilitation Robot Based on Its Clinical Evaluation
The paper presents the design optimization of the ASPIRE spherical parallel robot for shoulder rehabilitation following clinical evaluation and clinicians’ feedback. After the development of the robotic structure and the implementation of the control system, ASPIRE was prepared for clinical evaluation. A set of clinical trials was performed on 24 patients with different neurological disorders to obtain the patient and clinician acceptance of the rehabilitation system. During the clinical trials, the behavior of the robotic system was closely monitored and analyzed in order to improve its reliability and overall efficiency. Along with its reliability and efficiency, special attention was given to the safety characteristics during the rehabilitation task.
- 15 September 2020
- Published by Springer Nature
- p. 154-161
Experimental Study Regarding Needle Deflection in Robotic Assisted Brachytherapy of Hepatocellular Carcinoma
- 15 September 2020
- Published by Springer Nature
- p. 154-161
Experimental Study Regarding Needle Deflection in Robotic Assisted Brachytherapy of Hepatocellular Carcinoma
- Open Access
- 19 January 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (2) , 654
Fuzzy Logic-Based Risk Assessment of a Parallel Robot for Elbow and Wrist Rehabilitation
A few decades ago, robotics started to be implemented in the medical field, especially in the rehabilitation of patients with different neurological diseases that have led to neuromuscular disorders. The main concern regarding medical robots is their safety assurance in the medical environment. The goal of this paper is to assess the risk of a medical robotic system for elbow and wrist rehabilitation in terms of robot and patient safety. The approached risk assessment follows the ISO12100:2010 risk management chart in order to determine, identify, estimate, and evaluate the possible risk that can occur during the use of the robotic system. The result of the risk assessment process is further analyzed using a fuzzy logic system in order to determine the safety degree conferred during the use of the robotic system. The innovative process concerning the risk assessment allows the achievement of a reliable medical robotic system both for the patient and the clinicians as well. The clinical trials performed on a group of 18 patients validated the functionality and the safe behavior of the robotic system.
- 19 January 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (2) , 654
Open AccessFuzzy Logic-Based Risk Assessment of a Parallel Robot for Elbow and Wrist Rehabilitation
A few decades ago, robotics started to be implemented in the medical field, especially in the rehabilitation of patients with different neurological diseases that have led to neuromuscular disorders. The main concern regarding medical robots is their safety assurance in the medical environment. The goal of this paper is to assess the risk of a medical robotic system for elbow and wrist rehabilitation in terms of robot and patient safety. The approached risk assessment follows the ISO12100:2010 risk management chart in order to determine, identify, estimate, and evaluate the possible risk that can occur during the use of the robotic system. The result of the risk assessment process is further analyzed using a fuzzy logic system in order to determine the safety degree conferred during the use of the robotic system. The innovative process concerning the risk assessment allows the achievement of a reliable medical robotic system both for the patient and the clinicians as well. The clinical trials performed on a group of 18 patients validated the functionality and the safe behavior of the robotic system.
- Open Access
- 19 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 52
Risk Management for the Reliability of Robotic Assisted Treatment of Non-resectable Liver Tumors
Hepatic cancers represent an important worldwide health issue where surgery alone in most cases is not a feasible therapeutic solution since most tumors are non-resectable. Despite targeted therapies showing positive results in other areas of cancer treatment, in the case of liver tumors, no low-risk delivery methods have been identified. Based on a risk assessment approach, this paper proposes a technical solution in the form of a robotic system capable of achieving a reliable delivery method for targeted treatment, focusing on the patient safety and therapeutic efficiency. The design of the robotic system starts from the definition of the design constraints with respect to the medical protocol. An analytical hierarchy process is used to prioritize the data correlated with the technical characteristics of a new robotic system, aiming to minimize risks associated with the medical procedure. In a four-phase quality function deployment, the technical solution is evaluated with respect to the quality characteristics, functions, subsystems, and components aiming to achieve a safe and reliable system with high therapeutic efficiency. The results lead to the concept of HeRo, a parallel robotic system for the reliable targeted treatment of non-resectable liver tumors.
- 19 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 52
Open AccessRisk Management for the Reliability of Robotic Assisted Treatment of Non-resectable Liver Tumors
Hepatic cancers represent an important worldwide health issue where surgery alone in most cases is not a feasible therapeutic solution since most tumors are non-resectable. Despite targeted therapies showing positive results in other areas of cancer treatment, in the case of liver tumors, no low-risk delivery methods have been identified. Based on a risk assessment approach, this paper proposes a technical solution in the form of a robotic system capable of achieving a reliable delivery method for targeted treatment, focusing on the patient safety and therapeutic efficiency. The design of the robotic system starts from the definition of the design constraints with respect to the medical protocol. An analytical hierarchy process is used to prioritize the data correlated with the technical characteristics of a new robotic system, aiming to minimize risks associated with the medical procedure. In a four-phase quality function deployment, the technical solution is evaluated with respect to the quality characteristics, functions, subsystems, and components aiming to achieve a safe and reliable system with high therapeutic efficiency. The results lead to the concept of HeRo, a parallel robotic system for the reliable targeted treatment of non-resectable liver tumors.
- Open Access
- 21 May 2019
- Published by MDPI AG in Sustainability
- Vol. 11 (10) , 2893
Risk-Based Assessment Engineering of a Parallel Robot Used in Post-Stroke Upper Limb Rehabilitation
Recently, robotic-assisted stroke rehabilitation became an important research topic due to its capability to provide complex solutions to perform the customized rehabilitation motion with enhanced resources than the traditional rehabilitation. Involving robotic devices in the rehabilitation process would increase the number of possible rehabilitated patients, but placing the patient inside the workspace of the robot causes a series of risks that needs to be identified, analyzed and avoided. The goal of this work is to provide a reliable solution for an upper limb rehabilitation robotic structure designed as a result of a risk assessment process. The proposed approach implies a hazard identification process in terms of severity and probability, a failure mode and effects analysis to identify the possible malfunctions in the system and an AHP (Analytic Hierarchy Process) to prioritize the technical characteristics of the robotic structure. The results of the risk assessment process and of the AHP provide the base of the final design of the robotic structure, while another solution, in terms of minimizing the risk for the patient injury, is obtained using an external measuring system.
- 21 May 2019
- Published by MDPI AG in Sustainability
- Vol. 11 (10) , 2893
Open AccessRisk-Based Assessment Engineering of a Parallel Robot Used in Post-Stroke Upper Limb Rehabilitation
Recently, robotic-assisted stroke rehabilitation became an important research topic due to its capability to provide complex solutions to perform the customized rehabilitation motion with enhanced resources than the traditional rehabilitation. Involving robotic devices in the rehabilitation process would increase the number of possible rehabilitated patients, but placing the patient inside the workspace of the robot causes a series of risks that needs to be identified, analyzed and avoided. The goal of this work is to provide a reliable solution for an upper limb rehabilitation robotic structure designed as a result of a risk assessment process. The proposed approach implies a hazard identification process in terms of severity and probability, a failure mode and effects analysis to identify the possible malfunctions in the system and an AHP (Analytic Hierarchy Process) to prioritize the technical characteristics of the robotic structure. The results of the risk assessment process and of the AHP provide the base of the final design of the robotic structure, while another solution, in terms of minimizing the risk for the patient injury, is obtained using an external measuring system.
- 23 June 2018
- Published by Springer Nature
- p. 203-211
On the Singularities of a Parallel Robotic System Used for Elbow and Wrist Rehabilitation
- 23 June 2018
- Published by Springer Nature
- p. 203-211
On the Singularities of a Parallel Robotic System Used for Elbow and Wrist Rehabilitation
- 30 September 2017
- Published by Springer Nature in Mechanisms and Machine Science
- p. 464-473
On the Kinematics of an Innovative Spherical Parallel Robot for Shoulder Rehabilitation
- 30 September 2017
- Published by Springer Nature in Mechanisms and Machine Science
- p. 464-473
On the Kinematics of an Innovative Spherical Parallel Robot for Shoulder Rehabilitation
- 5 July 2017
- Published by Springer Nature in Mechanisms and Machine Science
- p. 135-142
Kinematic Analysis for a Prostate Biopsy Parallel Robot Using Study Parameters
- 5 July 2017
- Published by Springer Nature in Mechanisms and Machine Science
- p. 135-142
Kinematic Analysis for a Prostate Biopsy Parallel Robot Using Study Parameters
- 13 November 2015
- Published by Springer Nature
- p. 109-120
Virtual Planning of Needle Guidance for a Parallel Robot Used in Brachytherapy
- 13 November 2015
- Published by Springer Nature
- p. 109-120
Virtual Planning of Needle Guidance for a Parallel Robot Used in Brachytherapy