Peter van Thienen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peter van Thienen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- J. H. G. Vreeburg
KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, Netherlands
3 shared publications Jan Vreeburg
KWR Watercycle Research Institute, Post Box 1072, 3430 BB Nieuwegein, The Netherlands
2 shared publications- Mirjam Blokker
Delft University of Technology Stevinweg 1
2 shared publications - I. N. Vloerbergh
KWR Watercycle Research Institute, PO Box 1072, 3430 BB, Nieuwegein, The Netherlands
1 shared publication Ilse Pieterse-Quirijns
KWR Watercycle Research Institute, Post Box 1072, 3430 BB Nieuwegein, The Netherlands
1 shared publicationIna Vertommen
KWR Watercycle Research Institute, Post Box 1072, 3430 BB Nieuwegein, The Netherlands
1 shared publication
Latest Publications
- 27 November 2015
- Published by IWA Publishing in Journal of Hydroinformatics
- Vol. 18 (3) , 514-530
Automated feature recognition in CFPD analyses of DMA or supply area flow data
The recently introduced comparison of flow pattern distributions (CFPD) method for the identification, quantification and interpretation of anomalies in district metered areas (DMAs) or supply area flow time series relies, for practical applications, on visual identification and interpretation of features in CFPD block diagrams. This paper presents an algorithm for automated feature recognition in CFPD analyses of DMA or supply area flow data, called CuBOid, which is useful for objective selection and analysis of features and automated (pre-) screening of data. As such, it can contribute to rapid identification of new leakages, unregistered changes in valve status or network configuration, etc. in DMAs and supply areas. The method is tested on synthetic and real flow data. The obtained results show that the method performs well in synthetic tests and allows an objective identification of most anomalies in flow patterns in a real life data set.
- 27 November 2015
- Published by IWA Publishing in Journal of Hydroinformatics
- Vol. 18 (3) , 514-530
Automated feature recognition in CFPD analyses of DMA or supply area flow data
The recently introduced comparison of flow pattern distributions (CFPD) method for the identification, quantification and interpretation of anomalies in district metered areas (DMAs) or supply area flow time series relies, for practical applications, on visual identification and interpretation of features in CFPD block diagrams. This paper presents an algorithm for automated feature recognition in CFPD analyses of DMA or supply area flow data, called CuBOid, which is useful for objective selection and analysis of features and automated (pre-) screening of data. As such, it can contribute to rapid identification of new leakages, unregistered changes in valve status or network configuration, etc. in DMAs and supply areas. The method is tested on synthetic and real flow data. The obtained results show that the method performs well in synthetic tests and allows an objective identification of most anomalies in flow patterns in a real life data set.
- 1 August 2013
- Published by IWA Publishing in Water Supply
- Vol. 13 (4) , 906-913
Applications of discriminative flow pattern analysis using the CFPD method
Several applications of a new method for flow pattern analysis called the Comparison of Flow Pattern Distributions (CFPD) are presented. This method allows the user to compare flow patterns of a supply area and distinguish consistent from inconsistent changes in them. The so-called consistent changes are mainly caused by modifications in the characteristics of the population. The so-called inconsistent changes are generally related to new large volume customers, new types of water use and/or changes in leakage. Detailed knowledge of the supply area allows quantitative statements to be made about leakage. The method presented here is simple, not computationally intensive, independent of any model assumptions and easily implemented. The automated application of this method on long time series, called CFPD block analysis, is applied on data from three different areas. These applications illustrate, respectively, the identification and pinpointing (in time) of a small leak, the independent quantification of concurrent different types of changes with opposite signs in a supply pattern, and the difficulties of interpretation in cases in which climate has an overwhelming influence on demand patterns. In each case, discriminative quantification and visualization by the CFPD method result in features and trends in complicated time series becoming apparent at a glance.
- 1 August 2013
- Published by IWA Publishing in Water Supply
- Vol. 13 (4) , 906-913
Applications of discriminative flow pattern analysis using the CFPD method
Several applications of a new method for flow pattern analysis called the Comparison of Flow Pattern Distributions (CFPD) are presented. This method allows the user to compare flow patterns of a supply area and distinguish consistent from inconsistent changes in them. The so-called consistent changes are mainly caused by modifications in the characteristics of the population. The so-called inconsistent changes are generally related to new large volume customers, new types of water use and/or changes in leakage. Detailed knowledge of the supply area allows quantitative statements to be made about leakage. The method presented here is simple, not computationally intensive, independent of any model assumptions and easily implemented. The automated application of this method on long time series, called CFPD block analysis, is applied on data from three different areas. These applications illustrate, respectively, the identification and pinpointing (in time) of a small leak, the independent quantification of concurrent different types of changes with opposite signs in a supply pattern, and the difficulties of interpretation in cases in which climate has an overwhelming influence on demand patterns. In each case, discriminative quantification and visualization by the CFPD method result in features and trends in complicated time series becoming apparent at a glance.
- 1 August 2013
- Published by IWA Publishing in Water Supply
- Vol. 13 (4) , 1154-1160
Shared failure data for strategic asset management
Failure data are a valuable source of information on the condition of underground assets. Systematic registration of relevant items on cause, nature and circumstances of each occurring failure is, however, complicated in day-to-day practice. Moreover, in a network of limited size it takes a long time to obtain a statistically relevant amount of data. Dutch water companies in collaboration with the KWR Watercycle Research Institute have joined forces and developed a data standard and central database to store and analyse failure data. As of early 2012, 66,000 km of network are monitored, providing around 2,500 records on failure annually. All in all it provides solid information needed for strategic asset management that helps to support well established asset management plans.
- 1 August 2013
- Published by IWA Publishing in Water Supply
- Vol. 13 (4) , 1154-1160
Shared failure data for strategic asset management
Failure data are a valuable source of information on the condition of underground assets. Systematic registration of relevant items on cause, nature and circumstances of each occurring failure is, however, complicated in day-to-day practice. Moreover, in a network of limited size it takes a long time to obtain a statistically relevant amount of data. Dutch water companies in collaboration with the KWR Watercycle Research Institute have joined forces and developed a data standard and central database to store and analyse failure data. As of early 2012, 66,000 km of network are monitored, providing around 2,500 records on failure annually. All in all it provides solid information needed for strategic asset management that helps to support well established asset management plans.
- 9 July 2012
- Published by IWA Publishing in Journal of Hydroinformatics
- Vol. 15 (1) , 86-102
A method for quantitative discrimination in flow pattern evolution of water distribution supply areas with interpretation in terms of demand and leakage
A method, the comparison of flow pattern distributions (CFPD), is described in which the specific representation of flow measurements for two different time periods allows a direct, quantitative interpretation of changes in the pattern. Two types of changes can be distinguished. The first is changes from one period to the next in demand consistent with the existing pattern, e.g. due to changing weather or changes in the population size. The second type is inconsistent changes which may be due to increased leakage. The method is successfully applied to drinking water distribution systems of different sizes and characteristics. Being data driven, it is independent of model assumptions and therefore insensitive to uncertainties therein which may hinder some other leakage determination methods. Because it is simple to implement and apply but nevertheless powerful in distinguishing between consistent and inconsistent changes in water demand, the method provides water companies with a way to constantly monitor their networks for possible changes in customer demand and the possible occurrence of new leakages and also check archived data for similar changes. This could render additional information about customer behavior and the evolving condition of the network from data which is usually readily available at water companies.
- 9 July 2012
- Published by IWA Publishing in Journal of Hydroinformatics
- Vol. 15 (1) , 86-102
A method for quantitative discrimination in flow pattern evolution of water distribution supply areas with interpretation in terms of demand and leakage
A method, the comparison of flow pattern distributions (CFPD), is described in which the specific representation of flow measurements for two different time periods allows a direct, quantitative interpretation of changes in the pattern. Two types of changes can be distinguished. The first is changes from one period to the next in demand consistent with the existing pattern, e.g. due to changing weather or changes in the population size. The second type is inconsistent changes which may be due to increased leakage. The method is successfully applied to drinking water distribution systems of different sizes and characteristics. Being data driven, it is independent of model assumptions and therefore insensitive to uncertainties therein which may hinder some other leakage determination methods. Because it is simple to implement and apply but nevertheless powerful in distinguishing between consistent and inconsistent changes in water demand, the method provides water companies with a way to constantly monitor their networks for possible changes in customer demand and the possible occurrence of new leakages and also check archived data for similar changes. This could render additional information about customer behavior and the evolving condition of the network from data which is usually readily available at water companies.
- 21 December 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 635-642
Turbulent Processes in Drinking Water Distribution
Different particle transport mechanisms play a role in the buildup of discoloration potential in drinking water networks. In order to enhance our understanding of and thus our ability to predict this buildup, it is essential to recognize and understand the role of these mechanisms. Gravitational settling with drag has primarily been considered in this context. However, since flow in water distribution pipes is nearly always in the turbulent regime, turbulent processes should be considered as well. The two main turbulent processes which may be relevant for suspended particles are turbulent diffusion and turbophoresis. Whereas the former process tends to even out the particle concentration, the latter increases concentration gradients by driving particles towards the wall of the pipe. It may therefore enhance sediment deposition. The balance between these processes and gravitational settling determines the actual behavior. Vreeburg and Boxall (2007) have presented some experimental results which show sediment settling in the lower half of a horizontal pipe for low flow velocities, suggesting gravitational settling as the dominant mechanism, and settling on the entire pipe wall for higher flow velocities, which they explain qualitatively by invoking turbophoresis. In this work, we present an application of the turbulent particle deposition theory of Young and Leeming (1997) to conditions relevant for drinking water distribution systems. We predict quantitatively under which conditions turbophoresis may dominate sediment transport in radial direction and compare these results to experimental observations.
- 21 December 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 635-642
Turbulent Processes in Drinking Water Distribution
Different particle transport mechanisms play a role in the buildup of discoloration potential in drinking water networks. In order to enhance our understanding of and thus our ability to predict this buildup, it is essential to recognize and understand the role of these mechanisms. Gravitational settling with drag has primarily been considered in this context. However, since flow in water distribution pipes is nearly always in the turbulent regime, turbulent processes should be considered as well. The two main turbulent processes which may be relevant for suspended particles are turbulent diffusion and turbophoresis. Whereas the former process tends to even out the particle concentration, the latter increases concentration gradients by driving particles towards the wall of the pipe. It may therefore enhance sediment deposition. The balance between these processes and gravitational settling determines the actual behavior. Vreeburg and Boxall (2007) have presented some experimental results which show sediment settling in the lower half of a horizontal pipe for low flow velocities, suggesting gravitational settling as the dominant mechanism, and settling on the entire pipe wall for higher flow velocities, which they explain qualitatively by invoking turbophoresis. In this work, we present an application of the turbulent particle deposition theory of Young and Leeming (1997) to conditions relevant for drinking water distribution systems. We predict quantitatively under which conditions turbophoresis may dominate sediment transport in radial direction and compare these results to experimental observations.
- Open Access
- 7 December 2011
- Published by Copernicus GmbH in Drinking Water Engineering and Science
- Vol. 4 (1) , 61-69
Application of optical tomography in the study of discolouration in drinking water distribution systems
Theories describing the turbulent deposition of particles from aerosols have recently been applied to drinking water distribution. In order to allow the study of these processes in a quantitative way and internally observe a cloud of suspended particles in a pipe, we have developed an optical tomography technique and measuring device using low cost electronic components specifically for this application. The mathematical methodology and the electronic device are described in this paper, and tests of both the mathematical approach and the actual device are presented. We conclude that the mathematical framework presented is suitable and that the technical implementation works in a test setting. The described methodology may provide a valuable tool for the study of processes related to drinking water discolouration in the lab.
- 7 December 2011
- Published by Copernicus GmbH in Drinking Water Engineering and Science
- Vol. 4 (1) , 61-69
Open AccessApplication of optical tomography in the study of discolouration in drinking water distribution systems
Theories describing the turbulent deposition of particles from aerosols have recently been applied to drinking water distribution. In order to allow the study of these processes in a quantitative way and internally observe a cloud of suspended particles in a pipe, we have developed an optical tomography technique and measuring device using low cost electronic components specifically for this application. The mathematical methodology and the electronic device are described in this paper, and tests of both the mathematical approach and the actual device are presented. We conclude that the mathematical framework presented is suitable and that the technical implementation works in a test setting. The described methodology may provide a valuable tool for the study of processes related to drinking water discolouration in the lab.
- 19 May 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 2439-2448
Lab Experiments on Turbulent Processes Causing Discolouration Potential
Theories describing the turbulent deposition of particles from aerosols have recently been modified for and applied to drinking water distribution. In order to study these processes in a quantitative way and internally observe a cloud of suspended particles in a pipe, we have developed an optical tomography technique, which is described in this paper.
- 19 May 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 2439-2448
Lab Experiments on Turbulent Processes Causing Discolouration Potential
Theories describing the turbulent deposition of particles from aerosols have recently been modified for and applied to drinking water distribution. In order to study these processes in a quantitative way and internally observe a cloud of suspended particles in a pipe, we have developed an optical tomography technique, which is described in this paper.
- 28 February 2011
- Published by Elsevier in Water Research
- Vol. 45 (4) , 1807-1817
Radial transport processes as a precursor to particle deposition in drinking water distribution systems
- 28 February 2011
- Published by Elsevier in Water Research
- Vol. 45 (4) , 1807-1817
Radial transport processes as a precursor to particle deposition in drinking water distribution systems