Annelise E. Barron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Annelise E. Barron has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Brett A. Buchholz
4 shared publicationsMethal N. Albarghouthi
Department of Chemical Engineering, Northwestern University, Evanston, IL 60208, USA
4 shared publicationsErin A. S. Doherty
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
3 shared publicationsChrista N. Hestekin
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
2 shared publicationsChristopher P. Fredlake
Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
2 shared publications- Robert J. Meagher
Sandia National Laboratories
2 shared publications
Latest Publications
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3805-3815
The potential of electrophoretic mobility shift assays for clinical mutation detection
As the understanding of the links between genetic mutations and diseases continues to grow, there is an increasing need for techniques that can rapidly, inexpensively, and sensitively detect DNA sequence alterations. Typically, such analyses are performed on PCR‐amplified gene regions. Automated DNA sequencing by capillary array electrophoresis can be used, but is expensive to apply to large numbers of patient samples and/or large genes, and may not always reveal low‐abundance mutations in heterozygous samples. Many different types of genetic differences need to be detected, including single‐base substitutions and larger sequence alterations such as insertions, deletions, and inversions. Electrophoretic mobility shift assays seem well suited to this purpose and could be used for the efficient screening of patient samples for sequence alterations, effectively reducing the number of samples that must be subjected to full and careful sequencing. While there is much promise, many of the mobility shift assays presently under development have yet to be demonstrated to have the high sensitivity and specificity of mutation detection required for routine clinical application. Hence, further studies and optimization are required, in particular the application of these methods not only to particular genes but also to large numbers of patient samples in blinded studies aimed at the rigorous determination of sensitivity and specificity. This review examines the state‐of‐the‐art of the most commonly used mobility shift assays for mutation detection, including denaturing gradient gel electrophoresis, TGGE, SSCP, heteroduplex analysis, and denaturing HPLC.
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3805-3815
The potential of electrophoretic mobility shift assays for clinical mutation detection
As the understanding of the links between genetic mutations and diseases continues to grow, there is an increasing need for techniques that can rapidly, inexpensively, and sensitively detect DNA sequence alterations. Typically, such analyses are performed on PCR‐amplified gene regions. Automated DNA sequencing by capillary array electrophoresis can be used, but is expensive to apply to large numbers of patient samples and/or large genes, and may not always reveal low‐abundance mutations in heterozygous samples. Many different types of genetic differences need to be detected, including single‐base substitutions and larger sequence alterations such as insertions, deletions, and inversions. Electrophoretic mobility shift assays seem well suited to this purpose and could be used for the efficient screening of patient samples for sequence alterations, effectively reducing the number of samples that must be subjected to full and careful sequencing. While there is much promise, many of the mobility shift assays presently under development have yet to be demonstrated to have the high sensitivity and specificity of mutation detection required for routine clinical application. Hence, further studies and optimization are required, in particular the application of these methods not only to particular genes but also to large numbers of patient samples in blinded studies aimed at the rigorous determination of sensitivity and specificity. This review examines the state‐of‐the‐art of the most commonly used mobility shift assays for mutation detection, including denaturing gradient gel electrophoresis, TGGE, SSCP, heteroduplex analysis, and denaturing HPLC.
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3689-3702
What is the future of electrophoresis in large‐scale genomic sequencing?
Although a finished human genome reference sequence is now available, the ability to sequence large, complex genomes remains critically important for researchers in the biological sciences, and in particular, continued human genomic sequence determination will ultimately help to realize the promise of medical care tailored to an individual's unique genetic identity. Many new technologies are being developed to decrease the costs and to dramatically increase the data acquisition rate of such sequencing projects. These new sequencing approaches include Sanger reaction‐based technologies that have electrophoresis as the final separation step as well as those that use completely novel, nonelectrophoretic methods to generate sequence data. In this review, we discuss the various advances in sequencing technologies and evaluate the current limitations of novel methods that currently preclude their complete acceptance in large‐scale sequencing projects. Our primary goal is to analyze and predict the continuing role of electrophoresis in large‐scale DNA sequencing, both in the near and longer term.
- 9 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (19) , 3689-3702
What is the future of electrophoresis in large‐scale genomic sequencing?
Although a finished human genome reference sequence is now available, the ability to sequence large, complex genomes remains critically important for researchers in the biological sciences, and in particular, continued human genomic sequence determination will ultimately help to realize the promise of medical care tailored to an individual's unique genetic identity. Many new technologies are being developed to decrease the costs and to dramatically increase the data acquisition rate of such sequencing projects. These new sequencing approaches include Sanger reaction‐based technologies that have electrophoresis as the final separation step as well as those that use completely novel, nonelectrophoretic methods to generate sequence data. In this review, we discuss the various advances in sequencing technologies and evaluate the current limitations of novel methods that currently preclude their complete acceptance in large‐scale sequencing projects. Our primary goal is to analyze and predict the continuing role of electrophoresis in large‐scale DNA sequencing, both in the near and longer term.
- 19 January 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (2) , 331-350
End‐labeled free‐solution electrophoresis of DNA
DNA is a free‐draining polymer. This subtle but “unfortunate” property of highly charged polyelectrolytes makes it impossible to separate nucleic acids by free‐flow electrophoresis. This is why one must typically use a sieving matrix, such as a gel or an entangled polymer solution, in order to obtain some electrophoretic size separation. An alternative approach consists of breaking the charge to friction balance of free‐draining DNA molecules. This can be achieved by labeling the DNA with a large, uncharged molecule (essentially a hydrodynamic parachute, which we also call a drag‐tag) prior to electrophoresis; the resulting methodology is called end‐labeled free‐solution electrophoresis (ELFSE). In this article, we review the development of ELFSE over the last decade. In particular, we examine the theoretical concepts used to predict the ultimate performance of ELFSE for single‐stranded (ssDNA) sequencing, the experimental results showing that ELFSE can indeed overcome the free‐draining issue raised above, and the technological advances that are needed to speed the development of competitive ELFSE‐based sequencing and separation technologies. Finally, we also review the reverse process, called free‐solution conjugate electrophoresis (FSCE), wherein uncharged polymers of different sizes can be analyzed using a short DNA molecule as an electrophoretic engine.
- 19 January 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (2) , 331-350
End‐labeled free‐solution electrophoresis of DNA
DNA is a free‐draining polymer. This subtle but “unfortunate” property of highly charged polyelectrolytes makes it impossible to separate nucleic acids by free‐flow electrophoresis. This is why one must typically use a sieving matrix, such as a gel or an entangled polymer solution, in order to obtain some electrophoretic size separation. An alternative approach consists of breaking the charge to friction balance of free‐draining DNA molecules. This can be achieved by labeling the DNA with a large, uncharged molecule (essentially a hydrodynamic parachute, which we also call a drag‐tag) prior to electrophoresis; the resulting methodology is called end‐labeled free‐solution electrophoresis (ELFSE). In this article, we review the development of ELFSE over the last decade. In particular, we examine the theoretical concepts used to predict the ultimate performance of ELFSE for single‐stranded (ssDNA) sequencing, the experimental results showing that ELFSE can indeed overcome the free‐draining issue raised above, and the technological advances that are needed to speed the development of competitive ELFSE‐based sequencing and separation technologies. Finally, we also review the reverse process, called free‐solution conjugate electrophoresis (FSCE), wherein uncharged polymers of different sizes can be analyzed using a short DNA molecule as an electrophoretic engine.
- 26 November 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (21-22) , 3564-3588
DNA sequencing and genotyping in miniaturized electrophoresis systems
Advances in microchannel electrophoretic separation systems for DNA analyses have had important impacts on biological and biomedical sciences, as exemplified by the successes of the Human Genome Project (HGP). As we enter a new era in genomic science, further technological innovations promise to provide other far‐reaching benefits, many of which will require continual increases in sequencing and genotyping efficiency and throughput, as well as major decreases in the cost per analysis. Since the high‐resolution size‐ and/or conformation‐based electrophoretic separation of DNA is the most critical step in many genetic analyses, continual advances in the development of materials and methods for microchannel electrophoretic separations will be needed to meet the massive demand for high‐quality, low‐cost genomic data. In particular, the development (and commercialization) of miniaturized genotyping platforms is needed to support and enable the future breakthroughs of biomedical science. In this review, we briefly discuss the major sequencing and genotyping techniques in which high‐throughput and high‐resolution electrophoretic separations of DNA play a significant role. We review recent advances in the development of technology for capillary electrophoresis (CE), including capillary array electrophoresis (CAE) systems. Most of these CE/CAE innovations are equally applicable to implementation on microfabricated electrophoresis chips. Major effort is devoted to discussing various key elements needed for the development of integrated and practical microfluidic sequencing and genotyping platforms, including chip substrate selection, microchannel design and fabrication, microchannel surface modification, sample preparation, analyte detection, DNA sieving matrices, and device integration. Finally, we identify some of the remaining challenges, and some of the possible routes to further advances in high‐throughput DNA sequencing and genotyping technologies.
- 26 November 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (21-22) , 3564-3588
DNA sequencing and genotyping in miniaturized electrophoresis systems
Advances in microchannel electrophoretic separation systems for DNA analyses have had important impacts on biological and biomedical sciences, as exemplified by the successes of the Human Genome Project (HGP). As we enter a new era in genomic science, further technological innovations promise to provide other far‐reaching benefits, many of which will require continual increases in sequencing and genotyping efficiency and throughput, as well as major decreases in the cost per analysis. Since the high‐resolution size‐ and/or conformation‐based electrophoretic separation of DNA is the most critical step in many genetic analyses, continual advances in the development of materials and methods for microchannel electrophoretic separations will be needed to meet the massive demand for high‐quality, low‐cost genomic data. In particular, the development (and commercialization) of miniaturized genotyping platforms is needed to support and enable the future breakthroughs of biomedical science. In this review, we briefly discuss the major sequencing and genotyping techniques in which high‐throughput and high‐resolution electrophoretic separations of DNA play a significant role. We review recent advances in the development of technology for capillary electrophoresis (CE), including capillary array electrophoresis (CAE) systems. Most of these CE/CAE innovations are equally applicable to implementation on microfabricated electrophoresis chips. Major effort is devoted to discussing various key elements needed for the development of integrated and practical microfluidic sequencing and genotyping platforms, including chip substrate selection, microchannel design and fabrication, microchannel surface modification, sample preparation, analyte detection, DNA sieving matrices, and device integration. Finally, we identify some of the remaining challenges, and some of the possible routes to further advances in high‐throughput DNA sequencing and genotyping technologies.
- 16 April 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (7-8) , 1166-1175
Poly‐N‐hydroxyethylacrylamide as a novel, adsorbed coating for protein separation by capillary electrophoresis
We present the polymer poly‐N‐hydroxyethylacrylamide (PHEA) (trade name, polyDuramide™) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3–8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly‐N,N‐dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA‐coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.
- 16 April 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (7-8) , 1166-1175
Poly‐N‐hydroxyethylacrylamide as a novel, adsorbed coating for protein separation by capillary electrophoresis
We present the polymer poly‐N‐hydroxyethylacrylamide (PHEA) (trade name, polyDuramide™) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3–8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly‐N,N‐dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA‐coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.
- 10 January 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (1-2) , 34-54
Microchannel wall coatings for protein separations by capillary and chip electrophoresis
The necessity for microchannel wall coatings in capillary and chip‐based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused‐silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes – covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.
- 10 January 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (1-2) , 34-54
Microchannel wall coatings for protein separations by capillary and chip electrophoresis
The necessity for microchannel wall coatings in capillary and chip‐based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused‐silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes – covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.
- 23 May 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (10) , 1421-1428
DNA sequencing with hydrophilic and hydrophobic polymers at elevated column temperatures
- 23 May 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (10) , 1421-1428
DNA sequencing with hydrophilic and hydrophobic polymers at elevated column temperatures
- 1 May 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (10) , 1375-1385
Technical challenges in applying capillary electrophoresis-single strand conformation polymorphism for routine genetic analysis
Recent and future advances in population genetics will have a significant impact on health care practices and the economics of health care provision only if a spectrum of patient‐tailored, effective methods of DNA screening for sequence alterations has been developed. Genetic screening by capillary electrophoresis‐single strand conformation polymorphism (CE‐SSCP), which is based upon the differences in electrophoretic mobilities of wild‐type and mutant DNA species, offers an important complement to other presently available techniques such as Sanger sequencing and DNA hybridization arrays due to its simplicity, versatility, and low cost of analysis. A two‐part review of CE‐SSCP that discusses its advantages and limitations is presented. Emphasis is placed on technological aspects of CE‐SSCP (including such rarely addressed issues as sample preparation protocols and the nature of the polymeric DNA separation matrix) as well as on the potential of CE‐SSCP for routine genetic analysis. An attempt is made to organize and present the information in sufficient detail to allow the use of SSCP for routine genetic screening even by those inexperienced in CE. Some discussion of CE‐based heteroduplex analysis (HA) is also presented.
- 1 May 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (10) , 1375-1385
Technical challenges in applying capillary electrophoresis-single strand conformation polymorphism for routine genetic analysis
Recent and future advances in population genetics will have a significant impact on health care practices and the economics of health care provision only if a spectrum of patient‐tailored, effective methods of DNA screening for sequence alterations has been developed. Genetic screening by capillary electrophoresis‐single strand conformation polymorphism (CE‐SSCP), which is based upon the differences in electrophoretic mobilities of wild‐type and mutant DNA species, offers an important complement to other presently available techniques such as Sanger sequencing and DNA hybridization arrays due to its simplicity, versatility, and low cost of analysis. A two‐part review of CE‐SSCP that discusses its advantages and limitations is presented. Emphasis is placed on technological aspects of CE‐SSCP (including such rarely addressed issues as sample preparation protocols and the nature of the polymeric DNA separation matrix) as well as on the potential of CE‐SSCP for routine genetic analysis. An attempt is made to organize and present the information in sufficient detail to allow the use of SSCP for routine genetic screening even by those inexperienced in CE. Some discussion of CE‐based heteroduplex analysis (HA) is also presented.
- 1 May 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (10) , 1398-1409
Microchannel DNA sequencing matrices with switchable viscosities
We review the variety of thermo‐responsive and shear‐responsive polymer solutions with “switchable” viscosities that have been proposed for application as DNA sequencing matrices for capillary and microfluidic chip electrophoresis. Generally, highly entangled polymer solutions of high‐molar mass polymers are necessary for the attainment of long DNA sequencing read lengths (> 500 bases) with short analysis times (< 3 h). However, these entangled polymer matrices create practical difficulties for microchannel electrophoresis with their extremely high viscosities, necessitating high‐pressure loading into capillaries or chips. Shear‐responsive (shear‐thinning) polymer matrices exhibit a rapid drop in viscosity as the applied shear force is increased, but still require a high initial pressure to initiate flow of the solution into a microchannel. Polymer matrices designed to have thermo‐responsive properties display either a lowered (thermo‐thinning) or raised (thermo‐thickening) viscosity as the temperature of the solution is elevated. These properties are generally designed into the polymers by the incorporation of moderately hydrophobic groups in some part of the polymer structure, which either phase‐separate or hydrophobically aggregate at higher temperatures. In their low‐viscosity states, these matrices that allow rapid loading of capillary or chip microchannels under low applied pressure. The primary goal of work in this area is to design polymer matrices that exhibit this responsive behavior and hence easy microchannel loading, without a reduction in DNA separation performance compared to conventional matrices. While good progress has been made, thermo‐responsive matrices have yet to offer sequencing performance as good as nonthermo‐responsive networks. The challenge remains to accomplish this goal through the innovative design of novel polymer structures.
- 1 May 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (10) , 1398-1409
Microchannel DNA sequencing matrices with switchable viscosities
We review the variety of thermo‐responsive and shear‐responsive polymer solutions with “switchable” viscosities that have been proposed for application as DNA sequencing matrices for capillary and microfluidic chip electrophoresis. Generally, highly entangled polymer solutions of high‐molar mass polymers are necessary for the attainment of long DNA sequencing read lengths (> 500 bases) with short analysis times (< 3 h). However, these entangled polymer matrices create practical difficulties for microchannel electrophoresis with their extremely high viscosities, necessitating high‐pressure loading into capillaries or chips. Shear‐responsive (shear‐thinning) polymer matrices exhibit a rapid drop in viscosity as the applied shear force is increased, but still require a high initial pressure to initiate flow of the solution into a microchannel. Polymer matrices designed to have thermo‐responsive properties display either a lowered (thermo‐thinning) or raised (thermo‐thickening) viscosity as the temperature of the solution is elevated. These properties are generally designed into the polymers by the incorporation of moderately hydrophobic groups in some part of the polymer structure, which either phase‐separate or hydrophobically aggregate at higher temperatures. In their low‐viscosity states, these matrices that allow rapid loading of capillary or chip microchannels under low applied pressure. The primary goal of work in this area is to design polymer matrices that exhibit this responsive behavior and hence easy microchannel loading, without a reduction in DNA separation performance compared to conventional matrices. While good progress has been made, thermo‐responsive matrices have yet to offer sequencing performance as good as nonthermo‐responsive networks. The challenge remains to accomplish this goal through the innovative design of novel polymer structures.
- 1 November 2001
- Published by Wiley in Electrophoresis
- Vol. 22 (19) , 4118-4128
The use of light scattering for precise characterization of polymers for DNA sequencing by capillary electrophoresis
The ability of a polymer matrix to separate DNA by capillary electrophoresis (CE) is strongly dependent upon polymer physical properties. In particular, recent results have shown that DNA sequencing performance is very sensitive to both the average molar mass and the average coil radius of the separation matrix polymers, which are affected by both polymer structure and polymer‐solvent affinity. Large polymers with high average molar mass provide the best DNA sequencing separations for CE, but are also the most challenging to characterize with accuracy. The methods most commonly used for the characterization of water‐soluble polymers with application in microchannel electrophoresis have been gel permeation chromatography (GPC) and intrinsic viscosity measurements, but the limitations and potential inaccuracies of these approaches, particularly for large or novel polymers and copolymers, press the need for a more universally accurate method of polymer molar mass profiling for advanced DNA separation matrices. Here, we show that multi‐angle laser light scattering (MALLS) measurements, carried out either alone or in tandem with prior on‐line sample fractionation by GPC, can provide accurate molar mass and coil radius information for polymer samples that are useful for DNA sequencing by CE. Wider employment of MALLS for characterization of novel polymers designed as DNA separation matrices for microchannel electrophoresis should enable more rapid optimization of matrix properties and formulation, and assist in the development of novel classes of polymer matrices.
- 1 November 2001
- Published by Wiley in Electrophoresis
- Vol. 22 (19) , 4118-4128
The use of light scattering for precise characterization of polymers for DNA sequencing by capillary electrophoresis
The ability of a polymer matrix to separate DNA by capillary electrophoresis (CE) is strongly dependent upon polymer physical properties. In particular, recent results have shown that DNA sequencing performance is very sensitive to both the average molar mass and the average coil radius of the separation matrix polymers, which are affected by both polymer structure and polymer‐solvent affinity. Large polymers with high average molar mass provide the best DNA sequencing separations for CE, but are also the most challenging to characterize with accuracy. The methods most commonly used for the characterization of water‐soluble polymers with application in microchannel electrophoresis have been gel permeation chromatography (GPC) and intrinsic viscosity measurements, but the limitations and potential inaccuracies of these approaches, particularly for large or novel polymers and copolymers, press the need for a more universally accurate method of polymer molar mass profiling for advanced DNA separation matrices. Here, we show that multi‐angle laser light scattering (MALLS) measurements, carried out either alone or in tandem with prior on‐line sample fractionation by GPC, can provide accurate molar mass and coil radius information for polymer samples that are useful for DNA sequencing by CE. Wider employment of MALLS for characterization of novel polymers designed as DNA separation matrices for microchannel electrophoresis should enable more rapid optimization of matrix properties and formulation, and assist in the development of novel classes of polymer matrices.