Jean-François Loret
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jean-François Loret has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Samuel Robert
Suez, CIRSEE, 38 rue du président Wilson, 78230 Le Pecq, France
6 shared publications F. Ribas
Agbar, Avenida Diagonal 211, 08018, Barcelona, Spain
2 shared publicationsG. Saucedo
Agbar, Avenida Diagonal 211, 08018, Barcelona, Spain
2 shared publications- Gilbert Greub
Institute of Microbiology, University Hospital Center and University of Lausanne, Lausanne, Switzerland
2 shared publications I. Baudin
Suez Environnement – Cirsee, 38 rue du Président Wilson, 78320 Le Pecq, France
2 shared publicationsL. Cossalter
Suez Environnement – Cirsee, 38 rue du Président Wilson, 78320 Le Pecq, France
2 shared publications
Latest Publications
- 1 November 2015
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 218 (8) , 675-676
The Sixth International Water and Health Seminar, Cannes 2014
- 1 November 2015
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 218 (8) , 675-676
The Sixth International Water and Health Seminar, Cannes 2014
- 1 November 2015
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 218 (8) , 723-730
Drinking water, diet, indoor air: Comparison of the contribution to environmental micropollutants exposure
- 1 November 2015
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 218 (8) , 723-730
Drinking water, diet, indoor air: Comparison of the contribution to environmental micropollutants exposure
- 1 June 2013
- Published by IWA Publishing in Water Practice & Technology
- Vol. 8 (2) , 166-179
Assessment and management of health risks related to the recycling of filter backwash water in drinking water production
Analytical campaigns were conducted on different drinking water treatment lines in order to characterize filter backwash water and assess the impact of recycling this water at the head of the plant. The pollutants identified in this water are essentially in the form of particles. Recycling this water may consequently increase the concentration of parameters such as turbidity, suspended solids, metals from coagulants and protozoa. On the other hand, no release of pesticides nor significant generation of disinfection by-products was observed during filter backwash with chlorinated water, in the conditions applied in France for chlorination. A modeling approach based on the mass balance of Cryptosporidium oocysts was applied to estimate the impact of recycling on oocysts concentration in the inlet water. A risk of infection was then assessed for each recycling scenario. A similar approach was also applied for amoebae, which have the capacity to colonize filter media, and for metal residues from coagulants. The results of this study demonstrate that two different situations have to be considered separately: • In the case of treatment lines composed of separate sedimentation and filtration steps, recycling at the head of the treatment process, even with no treatment, has no significant consequence on the microbial quality of the inlet water, and generates no additional health risk for the consumer. • In the case of treatment lines with no sedimentation step (direct filtration or UF used alone), recycling untreated water generates an excess of risk for the consumer which is not acceptable. Adding a coagulation / sedimentation step in the recycling circuit is sufficient in that case to keep the risk within acceptable limits.
- 1 June 2013
- Published by IWA Publishing in Water Practice & Technology
- Vol. 8 (2) , 166-179
Assessment and management of health risks related to the recycling of filter backwash water in drinking water production
Analytical campaigns were conducted on different drinking water treatment lines in order to characterize filter backwash water and assess the impact of recycling this water at the head of the plant. The pollutants identified in this water are essentially in the form of particles. Recycling this water may consequently increase the concentration of parameters such as turbidity, suspended solids, metals from coagulants and protozoa. On the other hand, no release of pesticides nor significant generation of disinfection by-products was observed during filter backwash with chlorinated water, in the conditions applied in France for chlorination. A modeling approach based on the mass balance of Cryptosporidium oocysts was applied to estimate the impact of recycling on oocysts concentration in the inlet water. A risk of infection was then assessed for each recycling scenario. A similar approach was also applied for amoebae, which have the capacity to colonize filter media, and for metal residues from coagulants. The results of this study demonstrate that two different situations have to be considered separately: • In the case of treatment lines composed of separate sedimentation and filtration steps, recycling at the head of the treatment process, even with no treatment, has no significant consequence on the microbial quality of the inlet water, and generates no additional health risk for the consumer. • In the case of treatment lines with no sedimentation step (direct filtration or UF used alone), recycling untreated water generates an excess of risk for the consumer which is not acceptable. Adding a coagulation / sedimentation step in the recycling circuit is sufficient in that case to keep the risk within acceptable limits.
- 1 June 2010
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 213 (3) , 167-175
Free-living amoebae: Biological by-passes in water treatment
- 1 June 2010
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 213 (3) , 167-175
Free-living amoebae: Biological by-passes in water treatment
- 1 August 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 58 (3) , 571-577
Amoebae-resisting bacteria in drinking water: risk assessment and management
Free-living amoebae have been detected in a large number of man-made water systems, including drinking water distribution systems. Some of these amoebae can host amoebae-resisting bacteria, and thus act potentially as reservoirs and vehicles for a number of pathogens. The objectives of this study were to characterize the amoebae and amoebae-resisting bacteria present in different raw waters used for drinking water production, and to assess the efficiency of different treatments applied for drinking water production in removing or inactivating these amoebae. The preliminary results of this study confirm the presence of amoebae and amoebae-resisting bacteria in raw waters used for drinking water production. Due to their capacity to encyst, most of these amoebae are extremely resistant to disinfection processes. In these conditions, preventing the dissemination of these micro-organisms through drinking water will mainly require their physical removal by clarification and filtration processes. The particular hazard that amoebae-resisting bacteria represent in drinking water production should be taken into account in any risk assessment conducted in the framework of a water safety plan, and control strategies based on physical removal rather than disinfection should be adopted where necessary.
- 1 August 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 58 (3) , 571-577
Amoebae-resisting bacteria in drinking water: risk assessment and management
Free-living amoebae have been detected in a large number of man-made water systems, including drinking water distribution systems. Some of these amoebae can host amoebae-resisting bacteria, and thus act potentially as reservoirs and vehicles for a number of pathogens. The objectives of this study were to characterize the amoebae and amoebae-resisting bacteria present in different raw waters used for drinking water production, and to assess the efficiency of different treatments applied for drinking water production in removing or inactivating these amoebae. The preliminary results of this study confirm the presence of amoebae and amoebae-resisting bacteria in raw waters used for drinking water production. Due to their capacity to encyst, most of these amoebae are extremely resistant to disinfection processes. In these conditions, preventing the dissemination of these micro-organisms through drinking water will mainly require their physical removal by clarification and filtration processes. The particular hazard that amoebae-resisting bacteria represent in drinking water production should be taken into account in any risk assessment conducted in the framework of a water safety plan, and control strategies based on physical removal rather than disinfection should be adopted where necessary.
- 1 January 2008
- Published by EDP Sciences in European journal of water quality
- Vol. 39 (1) , 37-50
Élimination des amibes libres par les procédés de traitement de l’eau potable
European journal of water quality, revue de l Association Scientifique Européenne pour l Eau et la Santé (ASEES) a pour vocation de publier des articles originaux sur le thème de l hydrologie
- 1 January 2008
- Published by EDP Sciences in European journal of water quality
- Vol. 39 (1) , 37-50
Élimination des amibes libres par les procédés de traitement de l’eau potable
European journal of water quality, revue de l Association Scientifique Européenne pour l Eau et la Santé (ASEES) a pour vocation de publier des articles originaux sur le thème de l hydrologie
- Open Access
- 1 December 2005
- Published by IWA Publishing in Journal of Water and Health
- Vol. 3 (4) , 423-433
Comparison of disinfectants for biofilm, protozoa and Legionella control
The aim of this study was to compare the efficiency of different disinfectants applicable to Legionella control in domestic water systems. A domestic water supply simulation unit that allowed simulation of real-world conditions was developed for this purpose. The system, consisting of seven identical rigs, was used to compare treatment efficiency under equivalent conditions of system design, materials, hydraulics, water quality, temperature and initial contamination. During the study, each of six loops received continuous application of one of the following disinfectants: chlorine, electro-chlorination, chlorine dioxide, monochloramine, ozone, or copper/silver. The seventh loop was used as a control and remained untreated. Performance evaluation of these disinfectants was based on their ability to reduce not only Legionella, but also protozoa and biofilms, which contribute to the establishment and dissemination of these bacteria in water systems, and their resistance to treatments. Regarding these criteria, chlorine dioxide and chlorine (as bleach or obtained by electro-chlorination) were the most effective treatments in this study. However, in comparison with chlorine, chlorine dioxide showed a longer residual activity in the system, which constituted an advantage in the perspective of an application to extensive pipework systems.
- 1 December 2005
- Published by IWA Publishing in Journal of Water and Health
- Vol. 3 (4) , 423-433
Open AccessComparison of disinfectants for biofilm, protozoa and Legionella control
The aim of this study was to compare the efficiency of different disinfectants applicable to Legionella control in domestic water systems. A domestic water supply simulation unit that allowed simulation of real-world conditions was developed for this purpose. The system, consisting of seven identical rigs, was used to compare treatment efficiency under equivalent conditions of system design, materials, hydraulics, water quality, temperature and initial contamination. During the study, each of six loops received continuous application of one of the following disinfectants: chlorine, electro-chlorination, chlorine dioxide, monochloramine, ozone, or copper/silver. The seventh loop was used as a control and remained untreated. Performance evaluation of these disinfectants was based on their ability to reduce not only Legionella, but also protozoa and biofilms, which contribute to the establishment and dissemination of these bacteria in water systems, and their resistance to treatments. Regarding these criteria, chlorine dioxide and chlorine (as bleach or obtained by electro-chlorination) were the most effective treatments in this study. However, in comparison with chlorine, chlorine dioxide showed a longer residual activity in the system, which constituted an advantage in the perspective of an application to extensive pipework systems.