Erman Pektok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Erman Pektok has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Afksendiyos Kalangos
Department of Cardiovascular Surgery, University Hospital of Geneva, Geneva, Switzerland
2 shared publications- Cagatay Engin
Department of Cardiovascular Surgery, Faculty of Medicine, Ege University, 35100 Izmir, Turkey
2 shared publications Mustafa Cikirikcioglu
2 shared publicationsSuha Kucukaksu
2 shared publicationsA Isin Dogan Ekici
1 shared publication- Afksendiyos Kalangos
Clinic for Cardiovascular Surgery, University Hospital of Geneva, Geneva, Switzerland
1 shared publication
Latest Publications
- 1 September 2016
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 62 (5) , 533-538
Outcomes of Various Treatment Strategies for Patients with Continuous-Flow Ventricular Assist Device Thrombosis: A Retrospective Analysis
Pump thrombosis is associated with high morbidity and mortality in patients with a continuous-flow left ventricular assist device. Although it has been defined clearly, the diagnosis and treatment of this complication still remain controversial. Between 2010 and 2014, 163 consecutive patients (mean age: 50.7 ± 13 years, 84% males, median duration of support: 277 (2-1077) days) were implanted a continuous-flow left ventricular assist device. Prospectively collected data of all patients who had at least one pump thrombosis event have been analyzed, retrospectively. Twenty-one pump thrombosis events were observed in 15 patients (9.2%, 0.137 events/patient-year). Median duration of support at the time of first pump thrombosis event was 259 (8-585) days. Overall mortality was 40% (6/15), and overall procedural success was 71.4% (15/21) in our entire cohort. The cause of mortality was hemorrhagic stroke in those who had medical treatment (n = 5), and sepsis and right ventricular failure in the other who had pump exchange. Pump exchange was performed in five patients, of which four survived. Glycoprotein IIb/IIIa antagonists are not beneficial in medical treatment of pump thrombosis. Medical treatment methods including unfractionated heparin and thrombolytics may completely resolve the thrombus and save some patients from pump exchange. In patients where medical treatment does not result in complete thrombus resolution within a reasonable period, and a donor heart is not available, pump exchange is the ultimate solution. Further studies are needed for optimal dosing of thrombolytics to decrease the rate of side effects.
- 1 September 2016
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 62 (5) , 533-538
Outcomes of Various Treatment Strategies for Patients with Continuous-Flow Ventricular Assist Device Thrombosis: A Retrospective Analysis
Pump thrombosis is associated with high morbidity and mortality in patients with a continuous-flow left ventricular assist device. Although it has been defined clearly, the diagnosis and treatment of this complication still remain controversial. Between 2010 and 2014, 163 consecutive patients (mean age: 50.7 ± 13 years, 84% males, median duration of support: 277 (2-1077) days) were implanted a continuous-flow left ventricular assist device. Prospectively collected data of all patients who had at least one pump thrombosis event have been analyzed, retrospectively. Twenty-one pump thrombosis events were observed in 15 patients (9.2%, 0.137 events/patient-year). Median duration of support at the time of first pump thrombosis event was 259 (8-585) days. Overall mortality was 40% (6/15), and overall procedural success was 71.4% (15/21) in our entire cohort. The cause of mortality was hemorrhagic stroke in those who had medical treatment (n = 5), and sepsis and right ventricular failure in the other who had pump exchange. Pump exchange was performed in five patients, of which four survived. Glycoprotein IIb/IIIa antagonists are not beneficial in medical treatment of pump thrombosis. Medical treatment methods including unfractionated heparin and thrombolytics may completely resolve the thrombus and save some patients from pump exchange. In patients where medical treatment does not result in complete thrombus resolution within a reasonable period, and a donor heart is not available, pump exchange is the ultimate solution. Further studies are needed for optimal dosing of thrombolytics to decrease the rate of side effects.
- Open Access
- 21 January 2014
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 22 (1) , 145-148
Sepsis and mediastinitis after heart transplantation: donor-transmitted Klebsiella infection
Early diagnosis and treatment of infection following heart transplantation is a determinant factor for the prognosis. However, it may easily be overlooked because of vague clinical signs and non-specific laboratory findings as a result of immunosuppression in these patients. Herein, we present a case of donor-transmitted bacterial infection after heart transplantation and its consequences.
- 21 January 2014
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 22 (1) , 145-148
Open AccessSepsis and mediastinitis after heart transplantation: donor-transmitted Klebsiella infection
Early diagnosis and treatment of infection following heart transplantation is a determinant factor for the prognosis. However, it may easily be overlooked because of vague clinical signs and non-specific laboratory findings as a result of immunosuppression in these patients. Herein, we present a case of donor-transmitted bacterial infection after heart transplantation and its consequences.
- 22 August 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (9) , 820-825
Remote Monitoring of Left Ventricular Assist Device Parameters After HeartAssist‐5 Implantation
Although several left ventricular assist devices (LVADs) have been used widely, remote monitoring of LVAD parameters has been available only recently. We present our remote monitoring experience with an axial‐flow LVAD (HeartAssist‐5, MicroMed Cardiovascular, Inc., Houston, TX, USA). Five consecutive patients who were implanted a HeartAssist‐5 LVAD because of end‐stage heart failure due to ischemic (n = 4) or idiopathic (n = 1) cardiomyopathy, and discharged from hospital between December 2011 and January 2013 were analyzed. The data (pump speed, pump flow, power consumption) obtained from clinical visits and remote monitoring were studied. During a median follow‐up of 253 (range: 80–394) days, fine tuning of LVADs was performed at clinical visits. All patients are doing well and are in New York Heart Association Class‐I/II. A total of 39 alarms were received from three patients. One patient was hospitalized for suspected thrombosis and was subjected to physical examinations as well as laboratory and echocardiographic evaluations; however, no evidence of thrombus washout or pump thrombus was found. The patient was treated conservatively. Remaining alarms were due to insufficient water intake and were resolved by increased water consumption at night and summer times, and fine tuning of pump speed. No alarms were received from the remaining two patients. We believe that remote monitoring is a useful technology for early detection and treatment of serious problems occurring out of hospital thereby improving patient care. Future developments may ease troubleshooting, provide more data from the patient and the pump, and eventually increase physician and patient satisfaction. Despite all potential clinical benefits, remote monitoring should be taken as a supplement to rather than a substitute for routine clinical visits for patient follow‐up.
- 22 August 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (9) , 820-825
Remote Monitoring of Left Ventricular Assist Device Parameters After HeartAssist‐5 Implantation
Although several left ventricular assist devices (LVADs) have been used widely, remote monitoring of LVAD parameters has been available only recently. We present our remote monitoring experience with an axial‐flow LVAD (HeartAssist‐5, MicroMed Cardiovascular, Inc., Houston, TX, USA). Five consecutive patients who were implanted a HeartAssist‐5 LVAD because of end‐stage heart failure due to ischemic (n = 4) or idiopathic (n = 1) cardiomyopathy, and discharged from hospital between December 2011 and January 2013 were analyzed. The data (pump speed, pump flow, power consumption) obtained from clinical visits and remote monitoring were studied. During a median follow‐up of 253 (range: 80–394) days, fine tuning of LVADs was performed at clinical visits. All patients are doing well and are in New York Heart Association Class‐I/II. A total of 39 alarms were received from three patients. One patient was hospitalized for suspected thrombosis and was subjected to physical examinations as well as laboratory and echocardiographic evaluations; however, no evidence of thrombus washout or pump thrombus was found. The patient was treated conservatively. Remaining alarms were due to insufficient water intake and were resolved by increased water consumption at night and summer times, and fine tuning of pump speed. No alarms were received from the remaining two patients. We believe that remote monitoring is a useful technology for early detection and treatment of serious problems occurring out of hospital thereby improving patient care. Future developments may ease troubleshooting, provide more data from the patient and the pump, and eventually increase physician and patient satisfaction. Despite all potential clinical benefits, remote monitoring should be taken as a supplement to rather than a substitute for routine clinical visits for patient follow‐up.
- 1 May 2013
- Vol. 22 (3) , 445-7
Biodegradable annuloplasty ring two years after implantation: first histological demonstration in human mitral annulus.
Although biodegradable annuloplasty rings have been used in clinics for almost a decade for mitral and/or tricuspid annuloplasty, the fate of the ring at the histological level has not been demonstrated in humans to date. The mitral annulus of a 39-year-old patient who underwent heart transplantation almost two years after annuloplasty was subjected to histological evaluation to demonstrate the mitral annular structures and consequences of biodegradable ring annuloplasty. On examination, the ring was shown to have completely degraded, and a fibrous band had formed in the posterior mitral annulus. No signs of residual calcification were observed. Neighboring structures such as circumflex artery and the great cardiac vein were intact. It can be concluded that the biodegradable annuloplasty ring is completely degraded in humans after implantation, leaving a fibrous band behind to support the posterior annulus. The risk of circumflex artery and great cardiac vein injury may not be considerable if the correct implantation technique is used.
- 1 May 2013
- Vol. 22 (3) , 445-7
Biodegradable annuloplasty ring two years after implantation: first histological demonstration in human mitral annulus.
Although biodegradable annuloplasty rings have been used in clinics for almost a decade for mitral and/or tricuspid annuloplasty, the fate of the ring at the histological level has not been demonstrated in humans to date. The mitral annulus of a 39-year-old patient who underwent heart transplantation almost two years after annuloplasty was subjected to histological evaluation to demonstrate the mitral annular structures and consequences of biodegradable ring annuloplasty. On examination, the ring was shown to have completely degraded, and a fibrous band had formed in the posterior mitral annulus. No signs of residual calcification were observed. Neighboring structures such as circumflex artery and the great cardiac vein were intact. It can be concluded that the biodegradable annuloplasty ring is completely degraded in humans after implantation, leaving a fibrous band behind to support the posterior annulus. The risk of circumflex artery and great cardiac vein injury may not be considerable if the correct implantation technique is used.
- 26 September 2012
- Published by Wiley in Artificial Organs
- Vol. 36 (10) , 936
Pulsatile Paracorporeal Pump Membrane Rupture: Clinical Advantage of a Multilayer Membrane
- 26 September 2012
- Published by Wiley in Artificial Organs
- Vol. 36 (10) , 936
Pulsatile Paracorporeal Pump Membrane Rupture: Clinical Advantage of a Multilayer Membrane
- 31 December 2010
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 90 (6) , 2089-2090
Biodegradable Ring Annuloplasty for Acute Endocarditis
- 31 December 2010
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 90 (6) , 2089-2090
Biodegradable Ring Annuloplasty for Acute Endocarditis
- 30 April 2010
- Published by Elsevier in Annales de Chirurgie Vasculaire
- Vol. 24 (3) , 458-461
Modèle dynamique sur cadavre humain pour tester la faisabilité de nouvelles techniques et d’outils endovasculaires
- 30 April 2010
- Published by Elsevier in Annales de Chirurgie Vasculaire
- Vol. 24 (3) , 458-461
Modèle dynamique sur cadavre humain pour tester la faisabilité de nouvelles techniques et d’outils endovasculaires
- 1 April 2010
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 89 (4) , 1180-1185
Midterm Results of Valve Repair With a Biodegradable Annuloplasty Ring for Acute Endocarditis
- 1 April 2010
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 89 (4) , 1180-1185
Midterm Results of Valve Repair With a Biodegradable Annuloplasty Ring for Acute Endocarditis
- 1 August 2007
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 134 (2) , 442-447
Does harvesting of an internal thoracic artery with an ultrasonic scalpel have an effect on sternal perfusion?
- 1 August 2007
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 134 (2) , 442-447
Does harvesting of an internal thoracic artery with an ultrasonic scalpel have an effect on sternal perfusion?