Garrick C. Stewart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Garrick C. Stewart has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Lynne W. Stevenson
4 shared publications- Mandeep R. Mehra
Mass General Brigham Heart and Vascular Institute and Harvard Medical School , Boston, MA
3 shared publications - Michael M. Givertz
Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
3 shared publications Janice M. Camuso
Massachusetts General Hospital, Harvard Medical School, Boston, MA
2 shared publications- Jean-Marie Connors
Hematology Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
2 shared publications - Jessica Rimsans
Department of Pharmacy Services, Brigham and Women's Hospital, Boston, Massachusetts
2 shared publications
Latest Publications
- 21 May 2018
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 46 (2) , 180-185
Four factor prothrombin complex concentrate for warfarin reversal in patients with left ventricular assist devices
Continuous flow left ventricular assist devices (CF-LVAD) require therapeutic anticoagulation which is often interrupted for procedures or bleeding. Prior to the availability of four factor prothrombin complex concentrate (4F-PCC) in the United States, warfarin was held and its effects reversed by vitamin K or fresh frozen plasma. We evaluated the use of 4F-PCC for temporary warfarin reversal in patients with CF-LVADs and assessed outcomes. This analysis is a retrospective study of CF-LVAD patients who received 4F-PCC for warfarin reversal in the setting of bleeding or need for urgent or elective procedures. Primary outcome assessments included feasibility of administration in elective versus emergent situations, safety measured as incidence of thrombotic events, and change in INR after administration. In total, 37 CF-LVAD patients received 49 4F-PCC administrations. The average 4F-PCC dose was 1842 units (range 518–4292 units), or 22 units/kg (range 5.8–58 units/kg). 4F-PCC significantly decreased the mean INR from 2.9 to 1.7 (p < 0.0001) in 47 of 49 administrations; two patients did not have post infusion INR testing. No cases of new confirmed or suspected pump thrombosis, stroke, venous thromboembolism, arterial thrombosis, or myocardial infarction were observed within 30 days of administration of 4F-PCC. 4F-PCC administration for temporary warfarin reversal was demonstrated to be feasible, effective, and, safe in CF-LVAD patients and judged to be 96% effective in patients for whom data were available. We observed no thrombotic events attributed to use of 4F-PCC.
- 21 May 2018
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 46 (2) , 180-185
Four factor prothrombin complex concentrate for warfarin reversal in patients with left ventricular assist devices
Continuous flow left ventricular assist devices (CF-LVAD) require therapeutic anticoagulation which is often interrupted for procedures or bleeding. Prior to the availability of four factor prothrombin complex concentrate (4F-PCC) in the United States, warfarin was held and its effects reversed by vitamin K or fresh frozen plasma. We evaluated the use of 4F-PCC for temporary warfarin reversal in patients with CF-LVADs and assessed outcomes. This analysis is a retrospective study of CF-LVAD patients who received 4F-PCC for warfarin reversal in the setting of bleeding or need for urgent or elective procedures. Primary outcome assessments included feasibility of administration in elective versus emergent situations, safety measured as incidence of thrombotic events, and change in INR after administration. In total, 37 CF-LVAD patients received 49 4F-PCC administrations. The average 4F-PCC dose was 1842 units (range 518–4292 units), or 22 units/kg (range 5.8–58 units/kg). 4F-PCC significantly decreased the mean INR from 2.9 to 1.7 (p < 0.0001) in 47 of 49 administrations; two patients did not have post infusion INR testing. No cases of new confirmed or suspected pump thrombosis, stroke, venous thromboembolism, arterial thrombosis, or myocardial infarction were observed within 30 days of administration of 4F-PCC. 4F-PCC administration for temporary warfarin reversal was demonstrated to be feasible, effective, and, safe in CF-LVAD patients and judged to be 96% effective in patients for whom data were available. We observed no thrombotic events attributed to use of 4F-PCC.
- 1 March 2018
- Published by Wolters Kluwer Health in Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine
- Vol. 17 (1) , 32-37
Development of an Outpatient Guideline for Optimal Anticoagulation Bridging in Patients With Durable Mechanical Circulatory Support
Patients with durable mechanical circulatory support are at increased risk of thromboembolic and bleeding complications. Current guidelines recommend that these patients receive chronic anticoagulation with warfarin to maintain a target international normalized ratio (INR) as specified by device manufacturers. Limited data exist regarding management of subtherapeutic INRs in this setting. To standardize clinical practice at our institution, we assembled a multidisciplinary task force including members from various specialties to develop a guideline for managing subtherapeutic INRs that incorporates published data and expert opinion. In this article, we present our clinical practice guideline as a decision support tool to aid clinicians in developing a consistent strategy for managing subtherapeutic INRs and for safely bridging anticoagulation in patients receiving mechanical circulatory support.
- 1 March 2018
- Published by Wolters Kluwer Health in Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine
- Vol. 17 (1) , 32-37
Development of an Outpatient Guideline for Optimal Anticoagulation Bridging in Patients With Durable Mechanical Circulatory Support
Patients with durable mechanical circulatory support are at increased risk of thromboembolic and bleeding complications. Current guidelines recommend that these patients receive chronic anticoagulation with warfarin to maintain a target international normalized ratio (INR) as specified by device manufacturers. Limited data exist regarding management of subtherapeutic INRs in this setting. To standardize clinical practice at our institution, we assembled a multidisciplinary task force including members from various specialties to develop a guideline for managing subtherapeutic INRs that incorporates published data and expert opinion. In this article, we present our clinical practice guideline as a decision support tool to aid clinicians in developing a consistent strategy for managing subtherapeutic INRs and for safely bridging anticoagulation in patients receiving mechanical circulatory support.
- 1 December 2016
- Published by Elsevier in JACC: Heart Failure
- Vol. 4 (12) , 959-961
Learning From Our Predictions
- 1 December 2016
- Published by Elsevier in JACC: Heart Failure
- Vol. 4 (12) , 959-961
Learning From Our Predictions
- 1 November 2016
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 9 (11)
INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) Profiling Identifies Ambulatory Patients at High Risk on Medical Therapy After Hospitalizations for Heart Failure
Background—: INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profiles provide important prognostic information for patients with advanced heart failure (HF) receiving mechanical support. The value of INTERMACS profiling has not been shown for patients followed on medical therapy for advanced HF at centers that also offer mechanical circulatory support. Methods and Results—: This prospective, observational study enrolled 166 patients with chronic New York Heart Association class III–IV HF, ejection fraction ≤30%, and ≥1 HF hospitalization in the previous year, excluding patients listed for transplant or receiving chronic intravenous inotropic therapy. Subjects were followed for at least 12 months or until death, mechanical support, or transplant. Baseline features, quality of life, and outcomes were compared according to INTERMACS profile. Mean age was 57 years, ejection fraction 18%, and 57% had HF >5 years, whereas 23% of subjects were INTERMACS profile 4, 32% profile 5, and 45% profile 6/7. At 1 year, only 47% of this ambulatory advanced HF cohort remained alive on medical therapy. Patients in INTERMACS profile 4 were more likely to die or require mechanical support, with only 52% of these patients alive without support after the first 6 months. Profile 6/7 patients had 1-year survival of 84%, similar to outcomes for contemporary destination left ventricular assist device recipients. Quality of life using the indexed EuroQol score was poor across profiles 4 to 7, although severe limitation was less common than for ambulatory patients enrolled in INTERMACS before ventricular assist device implantation. Conclusions—: Ambulatory patients with systolic HF, a heavy symptom burden, and at least 1 recent HF hospitalization are at high risk for death or left ventricular assist device rescue. INTERMACS profiles help identify ambulatory patients with advanced HF who may benefit from current mechanical support devices under existing indications.
- 1 November 2016
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 9 (11)
INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) Profiling Identifies Ambulatory Patients at High Risk on Medical Therapy After Hospitalizations for Heart Failure
Background—: INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profiles provide important prognostic information for patients with advanced heart failure (HF) receiving mechanical support. The value of INTERMACS profiling has not been shown for patients followed on medical therapy for advanced HF at centers that also offer mechanical circulatory support. Methods and Results—: This prospective, observational study enrolled 166 patients with chronic New York Heart Association class III–IV HF, ejection fraction ≤30%, and ≥1 HF hospitalization in the previous year, excluding patients listed for transplant or receiving chronic intravenous inotropic therapy. Subjects were followed for at least 12 months or until death, mechanical support, or transplant. Baseline features, quality of life, and outcomes were compared according to INTERMACS profile. Mean age was 57 years, ejection fraction 18%, and 57% had HF >5 years, whereas 23% of subjects were INTERMACS profile 4, 32% profile 5, and 45% profile 6/7. At 1 year, only 47% of this ambulatory advanced HF cohort remained alive on medical therapy. Patients in INTERMACS profile 4 were more likely to die or require mechanical support, with only 52% of these patients alive without support after the first 6 months. Profile 6/7 patients had 1-year survival of 84%, similar to outcomes for contemporary destination left ventricular assist device recipients. Quality of life using the indexed EuroQol score was poor across profiles 4 to 7, although severe limitation was less common than for ambulatory patients enrolled in INTERMACS before ventricular assist device implantation. Conclusions—: Ambulatory patients with systolic HF, a heavy symptom burden, and at least 1 recent HF hospitalization are at high risk for death or left ventricular assist device rescue. INTERMACS profiles help identify ambulatory patients with advanced HF who may benefit from current mechanical support devices under existing indications.
- 1 August 2016
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 9 (8)
Putting Life in the Years
- 1 August 2016
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 9 (8)
Putting Life in the Years
- 1 July 2016
- Published by Elsevier in Heart Failure Clinics
- Vol. 12 (3) , 323-333
Advanced Heart Failure
- 1 July 2016
- Published by Elsevier in Heart Failure Clinics
- Vol. 12 (3) , 323-333
Advanced Heart Failure
- 29 September 2015
- Published by Wolters Kluwer Health in Circulation
- Vol. 132 (13) , 1221-1223
Finding Traction for Mechanical Circulatory Support During Coronary Interventions
- 29 September 2015
- Published by Wolters Kluwer Health in Circulation
- Vol. 132 (13) , 1221-1223
Finding Traction for Mechanical Circulatory Support During Coronary Interventions
- 1 September 2015
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 8 (5) , 847-849
Mapping the Terrain of Competing Risk Following Primary Prevention Defibrillator Implantation
- 1 September 2015
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 8 (5) , 847-849
Mapping the Terrain of Competing Risk Following Primary Prevention Defibrillator Implantation
- 1 August 2015
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 21 (8) , S117
Grip Strength Assessment and Early Outcomes in Hospitalized Acute Decompensated Heart Failure: A Prospective Study
- 1 August 2015
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 21 (8) , S117
Grip Strength Assessment and Early Outcomes in Hospitalized Acute Decompensated Heart Failure: A Prospective Study