Roman Kaliszan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roman Kaliszan has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Michal Jan Markuszewski
Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdañsk, Gdañsk, Poland
8 shared publications - Paweł Wiczling
Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdañsk, Gdañsk, Poland
6 shared publications - Tomasz Bączek
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Medical University of Gdańsk, 80-416 Gdańsk, Poland
4 shared publications Antoni Nasal
3 shared publications- Anita Kornicka
Department of Chemical Technology of Drugs, Faculty of Pharmacy, Medical University of Gdańsk, 80-416 Gdańsk, Poland
2 shared publications - Antoni Nasal
Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdansk, Gen. J. Hallera 107, 80-416 Gdansk, Poland
2 shared publications
Latest Publications
- 1 January 2016
- Published by Springer Nature
- p. 241-280
Application of Trace Analysis for Medical Diagnosis and Monitoring of Selected Drugs
- 1 January 2016
- Published by Springer Nature
- p. 241-280
Application of Trace Analysis for Medical Diagnosis and Monitoring of Selected Drugs
- 2 October 2014
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 38 (1) , 62-67
Thermodynamic and QSRR Modeling of HPLC Retention on Modern Stationary Phases
This paper investigates correlations between the standard chromatographic parameter, log kw, obtained experimentally (classical thermodynamic) and obtained through the use of quantitative structure-retention relationships (QSRR) models (extrathermodynamic approach). QSRR models were created using descriptors from calculation chemistry, selected a priori on the basis of chemical intuition. Four modern analytical columns (packed with C18), often used in pharmaceutical analysis, were selected for the study. The simple extrathermodynamic model was demonstrated to be superior in terms of retention description with relation to rather complex models based on thermodynamic hermeneutics. However, all the QSRR equations derived are of limited predictive value as regards prediction of retention on the basis of the structure of the analyte. Nonetheless, they allow the differentiation of mechanism of separation operating on individual tested stationary phases. The descriptors, which are most significant in QSRR equations, appear to characterize better the net effect of interactions of the analytes with the stationary phases and the mobile phase containing acetonitrile as compared to the HPLC systems comprising methanol. These observations suggest that retention properties of new stationary phases studied in this work differ.
- 2 October 2014
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 38 (1) , 62-67
Thermodynamic and QSRR Modeling of HPLC Retention on Modern Stationary Phases
This paper investigates correlations between the standard chromatographic parameter, log kw, obtained experimentally (classical thermodynamic) and obtained through the use of quantitative structure-retention relationships (QSRR) models (extrathermodynamic approach). QSRR models were created using descriptors from calculation chemistry, selected a priori on the basis of chemical intuition. Four modern analytical columns (packed with C18), often used in pharmaceutical analysis, were selected for the study. The simple extrathermodynamic model was demonstrated to be superior in terms of retention description with relation to rather complex models based on thermodynamic hermeneutics. However, all the QSRR equations derived are of limited predictive value as regards prediction of retention on the basis of the structure of the analyte. Nonetheless, they allow the differentiation of mechanism of separation operating on individual tested stationary phases. The descriptors, which are most significant in QSRR equations, appear to characterize better the net effect of interactions of the analytes with the stationary phases and the mobile phase containing acetonitrile as compared to the HPLC systems comprising methanol. These observations suggest that retention properties of new stationary phases studied in this work differ.
- 1 March 2010
- Published by Bentham Science Publishers Ltd. in Current Alzheimer Research
- Vol. 7 (2) , 165-172
Association Constants of Pyridine and Piperidine Alkaloids to Amyloid ß Peptide Determined by Electrochemical Impedance Spectroscopy
Amyloid β(1-40) peptide was immobilized on an Au-colloid modified gold electrode and an electrochemical impedance spectroscopy (EIS) system was elaborated for determining the association constants, Ka, between small molecular ligands and the peptide. The changes in the resistance of the modified electrode layer with deposited Aβ(1-40) peptide were measured with EIS in relation to a series of concentrations of the ligands studied. The association constants were calculated from Langmuir isotherms. The method is sensitive, reproducible and consumes only very little amounts of interacting species. The method was applied to determine the affinity of a series of pyridine and piperidine derivatives, mainly alkaloids of a known ability, to cross the blood-brain barrier. Along with nicotine and its main metabolite cotinine, the following agents were taken for the study: anabasine, arecoline, coniine, lobeline, pseudopelletierine, trigonelline, as well as pyridine and piperidine themselves. For the sake of comparison, two vitamins were also subjected to the study: ascorbic acid and pyridoxine. There was no association of these vitamins, which were tested as a negative control. For the compounds studied, a strong association with Aβ(1-40) was determined with Ka ranging from 1.7 x 107 M-1 for (±)- anabasine to 2.3 x 108 M-1 for arecoline hydrobromide. As a positive control, a well known amyloid specific binder, Congo Red, was tested, displaying Ka equal to 3.7 x 108 M-1.
- 1 March 2010
- Published by Bentham Science Publishers Ltd. in Current Alzheimer Research
- Vol. 7 (2) , 165-172
Association Constants of Pyridine and Piperidine Alkaloids to Amyloid ß Peptide Determined by Electrochemical Impedance Spectroscopy
Amyloid β(1-40) peptide was immobilized on an Au-colloid modified gold electrode and an electrochemical impedance spectroscopy (EIS) system was elaborated for determining the association constants, Ka, between small molecular ligands and the peptide. The changes in the resistance of the modified electrode layer with deposited Aβ(1-40) peptide were measured with EIS in relation to a series of concentrations of the ligands studied. The association constants were calculated from Langmuir isotherms. The method is sensitive, reproducible and consumes only very little amounts of interacting species. The method was applied to determine the affinity of a series of pyridine and piperidine derivatives, mainly alkaloids of a known ability, to cross the blood-brain barrier. Along with nicotine and its main metabolite cotinine, the following agents were taken for the study: anabasine, arecoline, coniine, lobeline, pseudopelletierine, trigonelline, as well as pyridine and piperidine themselves. For the sake of comparison, two vitamins were also subjected to the study: ascorbic acid and pyridoxine. There was no association of these vitamins, which were tested as a negative control. For the compounds studied, a strong association with Aβ(1-40) was determined with Ka ranging from 1.7 x 107 M-1 for (±)- anabasine to 2.3 x 108 M-1 for arecoline hydrobromide. As a positive control, a well known amyloid specific binder, Congo Red, was tested, displaying Ka equal to 3.7 x 108 M-1.
- 1 November 2009
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 50 (4) , 549
Preface
- 1 November 2009
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 50 (4) , 549
Preface
- 19 December 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1214 (1-2) , 109-114
The application of gradient reversed-phase high-performance liquid chromatography to the pKa and logkw determination of polyprotic analytes
- 19 December 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1214 (1-2) , 109-114
The application of gradient reversed-phase high-performance liquid chromatography to the pKa and logkw determination of polyprotic analytes
- 14 August 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (16) , 2861-2873
Evaluation of different warping methods for the analysis of CE profiles of urinary nucleosides
Nowadays, numerous metabolite concentrations can readily be determined in a given biological sample by high‐throughput analytical methods. However, such raw analytical data comprise noninformative components due to many disturbances normally occurring in the analyses of biological material. To eliminate those unwanted original analytical data components, advanced chemometric data preprocessing methods might be of help. Here, such methods are applied to electrophoretic nucleoside profiles in urine samples of cancer patients and healthy volunteers. In this study, three warping methods: dynamic time warping (DTW), correlation optimized warping (COW), and parametric time warping (PTW) were examined on two sets of electrophoretic data by means of quality of peaks alignment, time of preprocessing, and way of customization. The application of warping methods helped to limit shifting of peaks and enabled differentiation between whole electropherograms of healthy and cancer patients objectively by a principal component analysis (PCA). The evaluation of preprocessed data and raw data by PC analysis confirms differences between the applied warping tools and proves their suitability in metabonomic data interpretation.
- 14 August 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (16) , 2861-2873
Evaluation of different warping methods for the analysis of CE profiles of urinary nucleosides
Nowadays, numerous metabolite concentrations can readily be determined in a given biological sample by high‐throughput analytical methods. However, such raw analytical data comprise noninformative components due to many disturbances normally occurring in the analyses of biological material. To eliminate those unwanted original analytical data components, advanced chemometric data preprocessing methods might be of help. Here, such methods are applied to electrophoretic nucleoside profiles in urine samples of cancer patients and healthy volunteers. In this study, three warping methods: dynamic time warping (DTW), correlation optimized warping (COW), and parametric time warping (PTW) were examined on two sets of electrophoretic data by means of quality of peaks alignment, time of preprocessing, and way of customization. The application of warping methods helped to limit shifting of peaks and enabled differentiation between whole electropherograms of healthy and cancer patients objectively by a principal component analysis (PCA). The evaluation of preprocessed data and raw data by PC analysis confirms differences between the applied warping tools and proves their suitability in metabonomic data interpretation.